964 resultados para INTERVENTIONAL ENDOSCOPY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bisegmentectomy 7-8 is feasible even in the absence of a large inferior right hepatic vein. To our knowledge, this operation has never been performed by laparoscopy. This study was designed to present video of pure laparoscopic bisegmentectomy 7-8 and bisegmentectomy 2-3 in one-stage operation for bilateral liver metastasis. A 67-year-old man with metachronous bilobar colorectal liver metastasis was referred for surgical treatment after neoadjuvant chemotherapy. CT scan disclosed two liver metastases: one located between segments 7 and 8 and another one in segment 2. At liver examination, another metastasis was found on segment 3. We decided to perform a bisegmentectomy 7-8 along with bisegmentectomy 2-3 in a single procedure. The operation began with mobilization of the right liver with complete dissection of retrohepatic vena cava. Inferior right hepatic vein was absent. Right hepatic vein was dissected and encircled. Upper part of right liver, containing segment 7 and 8, was marked with cautery. Selective hemi-Pringle maneuver was performed and right hepatic vein was divided with stapler. At this point, liver rotation to the left allowed direct view and access to the superior aspect of the right liver. Liver transection was accomplished with harmonic scalpel and endoscopic stapling device. Bisegmentectomy 2-3 was performed using the intrahepatic Glissonian approach. The specimens were extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 240 minutes with no need for transfusion. Recovery was uneventful. Patient was discharged on the fifth postoperative day. Patient is well with no evidence of disease 14 months after liver resection. Tumor markers are within normal range. Bisegmentectomy 7-8 may increase resectability rate in patients with bilateral lesions. This operation can be performed safely by laparoscopy. Preservation of segments 5 and 6 permitted simultaneous resection of segments 2 and 3 with adequate liver remnant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experience with advanced techniques has increased the indications for laparoscopic liver resection. This video demonstrates technical aspects of a pure laparoscopic mesohepatectomy using intrahepatic Glissonian technique. To the best of our knowledge, this is the first case of anatomic laparoscopic mesohepatectomy using the Glissonian approach published in the English literature. A 62-year-old man with colorectal liver metastasis occupying central liver segments was referred for surgical treatment. The first step is the control of segment 4 pedicle. Using the round ligament as a guide, one incision is performed on its right margin and another is made at the bottom of segment 4. A vascular clamp is introduced through those incisions to occlude segment 4 Glissonian sheath. The next step is to control the right anterior pedicle. The first incision is made in front of the hilum and another is performed on the right edge of gallbladder bed. Laparoscopic clamp is introduced through these incisions and closed producing ischemic discoloration of segments 5 and 8. Vascular clamp is replaced by an endoscopic vascular stapling device and stapler is fired. Line of liver transection is marked along the liver surface following ischemic area. Liver transection is accomplished with bipolar vessel sealing device and endoscopic stapling device as appropriate. Specimen was extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 200 min with minimum blood loss and no need for blood transfusion. Recovery was uneventful, and the patient was discharged on the fifth postoperative day. Histological examination revealed clear surgical margins. Mesohepatectomy can be safely performed laparoscopically in selected patients and by surgeons with expertise in both liver surgery and laparoscopic techniques. The use of the intrahepatic Glissonian approach may help to identify the exact limits of the mesohepatectomy to avoid ischemic injury of the remnant liver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Double-balloon enteroscopy (DBE) allows evaluation and therapy for various small bowel diseases. In this series the outcome of a 4-year experience in a tertiary hospital school in Brazil is reported. Methods: A total of 457 consecutive DBE were performed in 418 patients from August 2004 to August 2008. 93 patients with several indications, whose aim was not the evaluation of suspected diseases of the small bowel mucosa, were excluded, therefore leaving 364 DBE in 325 patients for analysis. Data were retrospectively collected with regard to clinical, endoscopic findings, therapy and complications. Results: Among the 364 DBE performed in 325 patients, 143/325 were males (44%) and 182/325 females (56%) with a mean age of 48.6 +/- 15.7 years (range 17-89). Mean investigation time was 64 +/- 22 min (range 35-135). The depth of insertion beyond the ligament of Treitz was 230 +/- 85 cm (range 30-500) by the antegrade approach and 140 +/- 75 cm (range 0-320) by the retrograde approach. Total enteroscopy was achieved in 41.66% of the attempts (30 of 72 patients). Overall diagnostic yield was 54.95% (200 of 364 procedures) ranging from 0 to 100% in this series, depending on the indication. Angiodysplasia was the main diagnosis in 24.5% (49 of 200 procedures) and endoscopic treatment, including biopsies, hemostasis, tattooing and polypectomy were performed in 65.38% (238 of 364 procedures). No major complications were reported. Conclusions: DBE is a feasible, safe and well-tolerated procedure allowing endoscopic therapy. Selection of indications increases its diagnostic yield. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interventional cardiology for paediatric and congenital cardiac disease is a relatively young and rapidly evolving field. As the profession begins to establish multi-institutional databases, a universal system of nomenclature is necessary for the field of interventional cardiology for paediatric and congenital cardiac disease. The purpose of this paper is to present the results of the efforts of The International Society for Nomenclature of Paediatric and Congenital Heart Disease to establish a system of nomenclature for cardiovascular catheterisation for congenital and paediatric cardiac disease, focusing both on procedural nomenclature and the nomenclature of complications associated with interventional cardiology. This system of nomenclature for cardiovascular catheterisation for congenital and paediatric cardiac disease is a component of The International Paediatric and Congenital Cardiac Code. This manuscript is the second part of the two-part series. Part 1 covered the procedural nomenclature associated with interventional cardiology as treatment for paediatric and congenital cardiac disease. Part 2 will cover the nomenclature of complications associated with interventional cardiology as treatment for paediatric and congenital cardiac disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While fluoroscopy is still the most widely used imaging modality to guide cardiac interventions, the fusion of pre-operative Magnetic Resonance Imaging (MRI) with real-time intra-operative ultrasound (US) is rapidly gaining clinical acceptance as a viable, radiation-free alternative. In order to improve the detection of the left ventricular (LV) surface in 4D ultrasound, we propose to take advantage of the pre-operative MRI scans to extract a realistic geometrical model representing the patients cardiac anatomy. This could serve as prior information in the interventional setting, allowing to increase the accuracy of the anatomy extraction step in US data. We have made use of a real-time 3D segmentation framework used in the recent past to solve the LV segmentation problem in MR and US data independently and we take advantage of this common link to introduce the prior information as a soft penalty term in the ultrasound segmentation algorithm. We tested the proposed algorithm in a clinical dataset of 38 patients undergoing both MR and US scans. The introduction of the personalized shape prior improves the accuracy and robustness of the LV segmentation, as supported by the error reduction when compared to core lab manual segmentation of the same US sequences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. METHOD: The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. RESULTS: The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El treball presentat suposa una visió general de l'"Endoscopia amb Càpsula de Vídeo Wireless" i la inspecció de sequències de contraccions intestinals amb les últimes tecnologies de visió per computador. Després de la observació preliminar dels fonaments mèdics requerits, la aplicació de visió per computador es presenta en aquestos termes. En essència, aquest treball proveïx una exhaustiva selecció, descripció i avaluació de cert conjunt de mètodes de processament d'imatges respecte a l'anàlisi de moviment, en el entorn de seqüències d'imatges preses amb una càpsula endoscòpica. Finalment, es presenta una aplicació de software per configurar i emprar de forma ràpida i fàcil un entorn experimental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work covers two aspects. First, it generally compares and summarizes the similarities and differences of state of the art feature detector and descriptor and second it presents a novel approach of detecting intestinal content (in particular bubbles) in capsule endoscopy images. Feature detectors and descriptors providing invariance to change of perspective, scale, signal-noise-ratio and lighting conditions are important and interesting topics in current research and the number of possible applications seems to be numberless. After analysing a selection of in the literature presented approaches, this work investigates in their suitability for applications information extraction in capsule endoscopy images. Eventually, a very good performing detector of intestinal content in capsule endoscopy images is presented. A accurate detection of intestinal content is crucial for all kinds of machine learning approaches and other analysis on capsule endoscopy studies because they occlude the field of view of the capsule camera and therefore those frames need to be excluded from analysis. As a so called “byproduct” of this investigation a graphical user interface supported Feature Analysis Tool is presented to execute and compare the discussed feature detectors and descriptor on arbitrary images, with configurable parameters and visualized their output. As well the presented bubble classifier is part of this tool and if a ground truth is available (or can also be generated using this tool) a detailed visualization of the validation result will be performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alveolar echinococcosis is characterized by a long asymptomatic period but, without treatment, up to 80% of patients may die within ten years of diagnosis. Owing to a lack of fast-acting and fully effective chemotherapy, partial radical hepatic resection is the only chance of cure. One-third of patients are now treated in this way, and complex vascular and biliary reconstruction procedures are sometimes necessary. Liver transplantation may also be indicated for highly selected patients (about 5%) with life-threatening complications after failure of other treatments. Interventional radiology and endoscopy can be used to drain liver abscesses and/or infected and obstructed bile ducts, either as palliative procedures or as a bridge to radical resection. Parasitostatic benzimidazole therapy, especially based on continuous albendazole administration, is mandatory for at least two years after radical resection, and for life in inoperable patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Increasing the appropriateness of use of upper gastrointestinal (GI) endoscopy is important to improve quality of care while at the same time containing costs. This study explored whether detailed explicit appropriateness criteria significantly improve the diagnostic yield of upper GI endoscopy. METHODS: Consecutive patients referred for upper GI endoscopy at 6 centers (1 university hospital, 2 district hospitals, 3 gastroenterology practices) were prospectively included over a 6-month period. After controlling for disease presentation and patient characteristics, the relationship between the appropriateness of upper GI endoscopy, as assessed by explicit Swiss criteria developed by the RAND/UCLA panel method, and the presence of relevant endoscopic lesions was analyzed. RESULTS: A total of 2088 patients (60% outpatients, 57% men) were included. Analysis was restricted to the 1681 patients referred for diagnostic upper GI endoscopy. Forty-six percent of upper GI endoscopies were judged to be appropriate, 15% uncertain, and 39% inappropriate by the explicit criteria. No cancer was found in upper GI endoscopies judged to be inappropriate. Upper GI endoscopies judged appropriate or uncertain yielded significantly more relevant lesions (60%) than did those judged to be inappropriate (37%; odds ratio 2.6: 95% CI [2.2, 3.2]). In multivariate analyses, the diagnostic yield of upper GI endoscopy was significantly influenced by appropriateness, patient gender and age, treatment setting, and symptoms. CONCLUSIONS: Upper GI endoscopies performed for appropriate indications resulted in detecting significantly more clinically relevant lesions than did those performed for inappropriate indications. In addition, no upper GI endoscopy that resulted in a diagnosis of cancer was judged to be inappropriate. The use of such criteria improves patient selection for upper GI endoscopy and can thus contribute to efforts aimed at enhancing the quality and efficiency of care. (Gastrointest Endosc 2000;52:333-41).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wide variation in patient exposure has been observed in interventional radiology and cardiology. The purpose of this study was to investigate the patient dose from fluoroscopy-guided procedures performed in non-academic centres when compared with academic centres. Four procedures (coronary angiography, percutaneous coronary intervention, angiography of the lower limbs and percutaneous transluminal angioplasty of the lower limbs) were evaluated. Data on the dose-area product, fluoroscopy time and number of images for 1000 procedures were obtained from 23 non-academic centres and compared with data from 5 academic centres. No differences were found for cardiology procedures performed in non-academic centres versus academic ones. However, significantly lower doses were delivered to patients for procedures of the lower limbs when they were performed in non-academic centres. This may be due to more complex procedures performed in the academic centres. Comparison between the centres showed a great variation in the patient dose for these lower limb procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.