986 resultados para Human lens


Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: To fabricate ultra-small algal chitosan nanoparticles (US CS NPs) for efficient delivery of bovine lactoferrin (bLf) to ocular tissues through topical administration to prevent carbendazim-induced toxicity. MATERIALS & METHODS: Rat eye model was used to evaluate the in vivo biodistribution the US CS NPs and bovine eye model was used for evaluating ex vivo biodistribution. Human lens epithelial cell line (HLEB-3) model was used to evaluate the in vitro toxicity, uptake mechanism and in vitro efficacy of the synthesized bLf-US CS NPs over carbendazim-induced ocular toxicity. RESULTS: The in vivo and ex vivo biodistribution results suggest that the ultra-small CS NPs efficiently internalize into the ocular tissues within 1 h after administering topically. Ultra-small algal nanocarriers to encapsulate bioactive antioxidant bLf protein and evaluated its potential in inhibiting carbendazim-induced human lens cell apoptosis and oxidative stress. CONCLUSION: US CS NPs could be explored for their potential for delivering various ocular drugs through topical administration for other eye diseases including cataract, glaucoma and age-related macular degeneration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Non-invasive measurements of the age dependence of refractive index distribution in human eye lenses in vitro using a novel X-ray Talbot Interferometry method. In their paper, the authors make frequent reference to our own work in which we employed magnetic resonance imaging (MRI) to make similar non-invasive measurements of the refractive index distribution in the human eye lens [2, 3]. Prior to the current work, ours was the only method for making such measurements both non-invasively and without prior assumptions about the shape of the refractive index distribution. For this reason, the latest work is to be welcomed. However at several points in the paper, Pierscionek et al. [1] make statements about our technique which are factually incorrect...

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A pilot study was conducted to evaluate human corneal epithelial cell shedding in response to wearing a silicone hydrogel contact lens/solution combination inducing corneal staining. The nature of ex vivo collected cells staining with fluorescein was also examined. A contralateral eye study was conducted in which up to eight participants were unilaterally exposed to a multipurpose contact lens solution/silicone hydrogel lens combination previously shown to induce corneal staining (renu® fresh™ and balafilcon A; test eye), with the other eye using a combination of balafilcon A soaked in a hydrogen peroxide care system (Clear Care®; control eye). Lenses were worn for 2, 4 or 6 hours. Corneal staining was graded after lens removal. The Ocular Surface Cell Collection Apparatus was used to collect cells from the cornea and the contact lens. In the test eye, maximum solution-induced corneal staining (SICS) was observed after 2 hours of lens wear (reducing significantly by 4 hours; p < 0.001). There were significantly more cells collected from the test eye after 4 hours of lens wear when compared to the control eye and the collection from the test eye after 2 hours (for both; n = 5; p < 0.001). The total cell yield at 4 hours was 813 ± 333 and 455 ± 218 for the test and control eyes, respectively (N = 5, triplicate, p = 0.003). A number of cells were observed to have taken up the fluorescein dye from the initial fluorescein instillation. Confocal microscopy of fluorescein-stained cells revealed that fluorescein was present throughout the cell cytoplasm and was retained in the cells for many hours after recovery from the corneal surface. This pilot study indicates that increased epithelial cell shedding was associated with a lens-solution combination which induces SICS. Our data provides insight into the transient nature of the SICS reaction and the nature of fluorescein staining observed in SICS.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

If deprived of wild-type p53 function, the body loses a guardian that protects against cancer. Restoration of p53 function has, therefore, been proposed as a means of counteracting oncogenesis. This concept of therapy requires prior knowledge with regard to proper balance of p53 function in a given target tissue. We have addressed this problem by targeting expression of the wild-type human p53 gene to the lens, a tissue entirely composed of epithelial cells that differentiate into elongated fiber cells. Transgenic mice expressing wild-type human p53 develop microphthalmia as a result of a defect in fiber formation that sets in shortly after birth. We see apoptotic cells that fail to undergo proper differentiation. In an effort to directly link the observed lens phenotype to the activity of the wild-type human p53 transgene, we also generated mice expressing a mutant human p53 allele that lacks wild-type function. A normal lens phenotype is restored in double transgenic animals that carry both wild-type and mutant human p53 alleles. Our study highlights the difficulties that can arise if p53 levels are improperly balanced in a differentiating tissue.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We describe a non-invasive phakometric method for determining corneal axis rotation relative to the visual axis (β) together with crystalline lens axis tilt (α) and decentration (d) relative to the corneal axis. This does not require corneal contact A-scan ultrasonography for the measurement of intraocular surface separations. Theoretical inherent errors of the method, evaluated by ray tracing through schematic eyes incorporating the full range of human ocular component variations, were found to be larger than the measurement errors (β < 0.67°, α < 0.72° and d < 0.08 mm) observed in nine human eyes with known ocular component dimensions. Intersubject variations (mean ± S.D.: β = 6.2 ± 3.4° temporal, α = 0.2 ± 1.8° temporal and d = 0.1 ± 0.1 mm temporal) and repeatability (1.96 × S.D. of difference between repeat readings: β ± 2.0°, α ± 1.8° and d ± 0.2 mm) were studied by measuring the left eyes of 45 subjects (aged 18-42 years, 29 females and 16 males, 15 Caucasians, 29 Indian Asians, one African, refractive error range -7.25 to +1.25 D mean spherical equivalent) on two occasions. © 2005 The College of Optometrists.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Finite element analysis is a useful tool in understanding how the accommodation system of the eye works. Further to simpler FEA models that have been used hitherto, this paper describes a sensitivity study which aims to understand which parameters of the crystalline lens are key to developing an accurate model of the accommodation system. A number of lens models were created, allowing the mechanical properties, internal structure and outer geometry to be varied. These models were then spun about their axes, and the deformations determined. The results showed the mechanical properties are the critical parameters, with the internal structure secondary. Further research is needed to fully understand how the internal structure and properties interact to affect lens deformation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The challenge that continues to face HRD is how to integrate real concerns for diversity into programs, practices, and research. Critical race theory was used as a lens to examine work on diversity published in Human Resource Development Quarterly (HRDQ). Eight publications were selected and analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Designers and artists have integrated recent advances in interactive, tangible and ubiquitous computing technologies to create new forms of interactive environments in the domains of work, recreation, culture and leisure. Many designs of technology systems begin with the workplace in mind, and with function, ease of use, and efficiency high on the list of priorities. [1] These priorities do not fit well with works designed for an interactive art environment, where the aims are many, and where the focus on utility and functionality is to support a playful, ambiguous or even experimental experience for the participants. To evaluate such works requires an integration of art-criticism techniques with more recent Human Computer Interaction (HCI) methods, and an understanding of the different nature of engagement in these environments. This paper begins a process of mapping a set of priorities for amplifying engagement in interactive art installations. I first define the concept of ludic engagement and its usefulness as a lens for both design and evaluation in these settings. I then detail two fieldwork evaluations I conducted within two exhibitions of interactive artworks, and discuss their outcomes and the future directions of this research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Archaeology provides a framework of analysis and interpretation that is useful for disentangling the textual layers of a contemporary lived-in urban space. The producers and readers of texts may include those who planned and developed the site and those who now live, visit and work there. Some of the social encounters and content sharing between these people may be artificially produced or manufactured in the hope that certain social situations will occur. Others may be serendipitous. With archaeology’s original focus on places that are no longer inhabited it is often only the remaining artefacts and features of the built environment that form the basis for interpreting the social relationships of past people. Our analysis however, is framed within a contemporary notion of archaeological artefacts in an urban setting. Unlike an excavation, where the past is revealed through digging into the landscape, the application of landscape archaeology within a present day urban context is necessarily more experiential, visual and based on recording and analysing the physical traces of social encounters and relationships between residents and visitors. These physical traces are present within the creative content, and the built and natural elements of the environment. This chapter explores notions of social encounters and content sharing in an urban village by analysing three different types of texts: the design of the built environment; content produced by residents through a geospatial web application; and, print and online media produced in digital storytelling workshops.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article provides an overview of the concept of vulnerability through the lens of the U.S. federal regulations for the protection of human subjects of research. General issues that emerge for nurse researchers working with regulated vulnerable populations are identified. Points of current controversy in the application of the regulations and current discourse about vulnerable groups are highlighted. Suggestions for negotiating the tension between federally regulated human subject requirements and the realities of research with vulnerable subjects are given. The limitations of the designation of vulnerable as a protection for human subjects will also be discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the capabilities of laser scanning confocal microscopy (LSCM) for undertaking qualitative and quantitative investigations of the response of the bulbar conjunctiva to contact lens wear. Methods: LSCM was used to observe and measure morphological characteristics of the bulbar conjunctiva of 11 asymptomatic soft contact lens wearers and 11 healthy volunteer subjects (controls). Results: The appearance of the bulbar conjunctiva is consistent with known histology of this tissue based on light and electron microscopy. The thickness of the bulbar conjunctival epithelium of lens wearers (30.9 ± 1.1 μm) was less than that of controls (32.9 ± 1.1 μm) (P < 0.0001). Superficial and basal bulbar conjunctival epithelial cell densities in contact lens wearers were 91% and 79% higher, respectively, than that in controls (P < 0.0001). No difference was observed in goblet and Langerhans cell density between lens wearers and controls. Conjunctival microcysts were observed in greater numbers, and were larger in size, in lens wearers compared with controls. Conclusions: The effects of contact lens wear on the human bulbar conjunctiva can be investigated effectively at a cellular level using LSCM. The observations in this study suggest that contact lens wear can induce changes in the bulbar conjunctiva such as epithelial thinning and accelerated formation and enlargement of microcysts, increased epithelial cell density, but has no impact on goblet or Langerhans cell density.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim/hypothesis Immune mechanisms have been proposed to play a role in the development of diabetic neuropathy. We employed in vivo corneal confocal microscopy (CCM) to quantify the presence and density of Langerhans cells (LCs) in relation to the extent of corneal nerve damage in Bowman's layer of the cornea in diabetic patients. Methods 128 diabetic patients aged 58±1 yrs with a differing severity of neuropathy based on Neuropathy Deficit Score (NDS—4.7±0.28) and 26 control subjects aged 53±3 yrs were examined. Subjects underwent a full neurological evaluation, evaluation of corneal sensation with non-contact corneal aesthesiometry (NCCA) and corneal nerve morphology using corneal confocal microscopy (CCM). Results The proportion of individuals with LCs was significantly increased in diabetic patients (73.8%) compared to control subjects (46.1%), P=0.001. Furthermore, LC density (no/mm2) was significantly increased in diabetic patients (17.73±1.45) compared to control subjects (6.94±1.58), P=0.001 and there was a significant correlation with age (r=0.162, P=0.047) and severity of neuropathy (r=−0.202, P=0.02). There was a progressive decrease in corneal sensation with increasing severity of neuropathy assessed using NDS in the diabetic patients (r=0.414, P=0.000). Corneal nerve fibre density (P<0.001), branch density (P<0.001) and length (P<0.001) were significantly decreased whilst tortuosity (P<0.01) was increased in diabetic patients with increasing severity of diabetic neuropathy. Conclusion Utilising in vivo corneal confocal microscopy we have demonstrated increased LCs in diabetic patients particularly in the earlier phases of corneal nerve damage suggestive of an immune mediated contribution to corneal nerve damage in diabetes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The depth of focus (DOF) can be defined as the variation in image distance of a lens or an optical system which can be tolerated without incurring an objectionable lack of sharpness of focus. The DOF of the human eye serves a mechanism of blur tolerance. As long as the target image remains within the depth of focus in the image space, the eye will still perceive the image as being clear. A large DOF is especially important for presbyopic patients with partial or complete loss of accommodation (presbyopia), since this helps them to obtain an acceptable retinal image when viewing a target moving through a range of near to intermediate distances. The aim of this research was to investigate the DOF of the human eye and its association with the natural wavefront aberrations, and how higher order aberrations (HOAs) can be used to expand the DOF, in particular by inducing spherical aberrations ( 0 4 Z and 0 6 Z ). The depth of focus of the human eye can be measured using a variety of subjective and objective methods. Subjective measurements based on a Badal optical system have been widely adopted, through which the retinal image size can be kept constant. In such measurements, the subject.s tested eye is normally cyclopleged. Objective methods without the need of cycloplegia are also used, where the eye.s accommodative response is continuously monitored. Generally, the DOF measured by subjective methods are slightly larger than those measured objectively. In recent years, methods have also been developed to estimate DOF from retinal image quality metrics (IQMs) derived from the ocular wavefront aberrations. In such methods, the DOF is defined as the range of defocus error that degrades the retinal image quality calculated from the IQMs to a certain level of the possible maximum value. In this study, the effect of different amounts of HOAs on the DOF was theoretically evaluated by modelling and comparing the DOF of subjects from four different clinical groups, including young emmetropes (20 subjects), young myopes (19 subjects), presbyopes (32 subjects) and keratoconics (35 subjects). A novel IQM-based through-focus algorithm was developed to theoretically predict the DOF of subjects with their natural HOAs. Additional primary spherical aberration ( 0 4 Z ) was also induced in the wavefronts of myopes and presbyopes to simulate the effect of myopic refractive correction (e.g. LASIK) and presbyopic correction (e.g. progressive power IOL) on the subject.s DOF. Larger amounts of HOAs were found to lead to greater values of predicted DOF. The introduction of primary spherical aberration was found to provide moderate increase of DOF while slightly deteriorating the image quality at the same time. The predicted DOF was also affected by the IQMs and the threshold level adopted. We then investigated the influence of the chosen threshold level of the IQMs on the predicted DOF, and how it relates to the subjectively measured DOF. The subjective DOF was measured in a group of 17 normal subjects, and we used through-focus visual Strehl ratio based on optical transfer function (VSOTF) derived from their wavefront aberrations as the IQM to estimate the DOF. The results allowed comparison of the subjective DOF with the estimated DOF and determination of a threshold level for DOF estimation. Significant correlation was found between the subject.s estimated threshold level for the estimated DOF and HOA RMS (Pearson.s r=0.88, p<0.001). The linear correlation can be used to estimate the threshold level for each individual subject, subsequently leading to a method for estimating individual.s DOF from a single measurement of their wavefront aberrations. A subsequent study was conducted to investigate the DOF of keratoconic subjects. Significant increases of the level of HOAs, including spherical aberration, coma and trefoil, can be observed in keratoconic eyes. This population of subjects provides an opportunity to study the influence of these HOAs on DOF. It was also expected that the asymmetric aberrations (coma and trefoil) in the keratoconic eye could interact with defocus to cause regional blur of the target. A dual-Badal-channel optical system with a star-pattern target was used to measure the subjective DOF in 10 keratoconic eyes and compared to those from a group of 10 normal subjects. The DOF measured in keratoconic eyes was significantly larger than that in normal eyes. However there was not a strong correlation between the large amount of HOA RMS and DOF in keratoconic eyes. Among all HOA terms, spherical aberration was found to be the only HOA that helped to significantly increase the DOF in the studied keratoconic subjects. Through the first three studies, a comprehensive understanding of DOF and its association to the HOAs in the human eye had been achieved. An adaptive optics system was then designed and constructed. The system was capable of measuring and altering the wavefront aberrations in the subject.s eye and measuring the resulting DOF under the influence of different combination of HOAs. Using the AO system, we investigated the concept of extending the DOF through optimized combinations of 0 4 Z and 0 6 Z . Systematic introduction of a targeted amount of both 0 4 Z and 0 6 Z was found to significantly improve the DOF of healthy subjects. The use of wavefront combinations of 0 4 Z and 0 6 Z with opposite signs can further expand the DOF, rather than using 0 4 Z or 0 6 Z alone. The optimal wavefront combinations to expand the DOF were estimated using the ratio of increase in DOF and loss of retinal image quality defined by VSOTF. In the experiment, the optimal combinations of 0 4 Z and 0 6 Z were found to provide a better balance of DOF expansion and relatively smaller decreases in VA. Therefore, the optimal combinations of 0 4 Z and 0 6 Z provides a more efficient method to expand the DOF rather than 0 4 Z or 0 6 Z alone. This PhD research has shown that there is a positive correlation between the DOF and the eye.s wavefront aberrations. More aberrated eyes generally have a larger DOF. The association of DOF and the natural HOAs in normal subjects can be quantified, which allows the estimation of DOF directly from the ocular wavefront aberration. Among the Zernike HOA terms, spherical aberrations ( 0 4 Z and 0 6 Z ) were found to improve the DOF. Certain combinations of 0 4 Z and 0 6 Z provide a more effective method to expand DOF than using 0 4 Z or 0 6 Z alone, and this could be useful in the optimal design of presbyopic optical corrections such as multifocal contact lenses, intraocular lenses and laser corneal surgeries.