987 resultados para Health Sciences, Radiology|Physics, Radiation|Biophysics, Medical
Resumo:
External beam radiation therapy is used to treat nearly half of the more than 200,000 new cases of prostate cancer diagnosed in the United States each year. During a radiation therapy treatment, healthy tissues in the path of the therapeutic beam are exposed to high doses. In addition, the whole body is exposed to a low-dose bath of unwanted scatter radiation from the pelvis and leakage radiation from the treatment unit. As a result, survivors of radiation therapy for prostate cancer face an elevated risk of developing a radiogenic second cancer. Recently, proton therapy has been shown to reduce the dose delivered by the therapeutic beam to normal tissues during treatment compared to intensity modulated x-ray therapy (IMXT, the current standard of care). However, the magnitude of stray radiation doses from proton therapy, and their impact on this incidence of radiogenic second cancers, was not known. ^ The risk of a radiogenic second cancer following proton therapy for prostate cancer relative to IMXT was determined for 3 patients of large, median, and small anatomical stature. Doses delivered to healthy tissues from the therapeutic beam were obtained from treatment planning system calculations. Stray doses from IMXT were taken from the literature, while stray doses from proton therapy were simulated using a Monte Carlo model of a passive scattering treatment unit and an anthropomorphic phantom. Baseline risk models were taken from the Biological Effects of Ionizing Radiation VII report. A sensitivity analysis was conducted to characterize the uncertainty of risk calculations to uncertainties in the risk model, the relative biological effectiveness (RBE) of neutrons for carcinogenesis, and inter-patient anatomical variations. ^ The risk projections revealed that proton therapy carries a lower risk for radiogenic second cancer incidence following prostate irradiation compared to IMXT. The sensitivity analysis revealed that the results of the risk analysis depended only weakly on uncertainties in the risk model and inter-patient variations. Second cancer risks were sensitive to changes in the RBE of neutrons. However, the findings of the study were qualitatively consistent for all patient sizes and risk models considered, and for all neutron RBE values less than 100. ^
Resumo:
Accurate calculation of absorbed dose to target tumors and normal tissues in the body is an important requirement for establishing fundamental dose-response relationships for radioimmunotherapy. Two major obstacles have been the difficulty in obtaining an accurate patient-specific 3-D activity map in-vivo and calculating the resulting absorbed dose. This study investigated a methodology for 3-D internal dosimetry, which integrates the 3-D biodistribution of the radionuclide acquired from SPECT with a dose-point kernel convolution technique to provide the 3-D distribution of absorbed dose. Accurate SPECT images were reconstructed with appropriate methods for noise filtering, attenuation correction, and Compton scatter correction. The SPECT images were converted into activity maps using a calibration phantom. The activity map was convolved with an $\sp{131}$I dose-point kernel using a 3-D fast Fourier transform to yield a 3-D distribution of absorbed dose. The 3-D absorbed dose map was then processed to provide the absorbed dose distribution in regions of interest. This methodology can provide heterogeneous distributions of absorbed dose in volumes of any size and shape with nonuniform distributions of activity. Comparison of the activities quantitated by our SPECT methodology to true activities in an Alderson abdominal phantom (with spleen, liver, and spherical tumor) yielded errors of $-$16.3% to 4.4%. Volume quantitation errors ranged from $-$4.0 to 5.9% for volumes greater than 88 ml. The percentage differences of the average absorbed dose rates calculated by this methodology and the MIRD S-values were 9.1% for liver, 13.7% for spleen, and 0.9% for the tumor. Good agreement (percent differences were less than 8%) was found between the absorbed dose due to penetrating radiation calculated from this methodology and TLD measurement. More accurate estimates of the 3-D distribution of absorbed dose can be used as a guide in specifying the minimum activity to be administered to patients to deliver a prescribed absorbed dose to tumor without exceeding the toxicity limits of normal tissues. ^
Resumo:
The proportional distribution of independent malignant tumors in the contralateral breast following treatment for breast cancer was investigated to assess the influence of scattered radiation as a cause of these tumors. In a population of 172 patients the proportion of contralateral tumors in each quadrant and the center (the nipple-areolar complex) was compared with the expected, or natural, distribution found in the general population, in the absence of radiation. The observed/expected ratio for contralateral tumors was 1.43 for the upper-inner quadrant; 0.97, lower-inner quadrant; 1.51, center; 0.76, upper-outer quadrant; and 0.64, lower-outer quadrant. In each quadrant, except the lower-inner, the observed/expected ratio differed from 1.00 with statistical significance at the 5% level (one-tail). The same analysis, stratified by age and menopausal status, showed a similar shift of tumors, with more than expected in the inner quadrants and center and less than expected in the outer quadrants, although the results did not show statistical significance at the 5% level for all strata. For each patient the mean absorbed radiation dose for each quadrant and center of the breast was estimated, based on measurements in a tissue-equivalent phantom. Among patients the doses ranged from 0.5 to 8 Gy; within individuals, doses to the inner quadrants typically were a factor of three times higher than doses to the outer quadrants. The results suggest that radiation may be a risk factor for contralateral breast tumors and warrants further investigation. ^
Resumo:
Mode of access: Internet.
Resumo:
The object of this work was to study the possibility that microtubule assembly might be involved in radiation sensitivity effect. The proliferating hair follicle was used to study the effects of cooling c-AMP, colcemid, and vincristine on the survival of the hair after irradiation. It was found that after 2 hours of cooling at the rewarming stage of the hair follicles, the sensitivity to irradiation increased and colcemid reversed this effect. c-AMP decreased radiosensitivity and together with colcemid, sensitivity decreased considerably. It is proposed that the assembly of microtubules is sensitive to irradiation.^ Total tubulin in L-P59 tumor measured immediately after irradiation was found to decrease in a dose specific manner after single doses ranging from 500 to 2000 rad. It is proposed that the change in Ca('2+) concentration after irradiation might cause this effect. Irradiation inhibited the increase in specific viscosity of 3x and 1x tubulin irradiated at the time of assembly. A small reduction in specific viscosity was found when polymerized microtubules were irradiated.^ From these experiments it is proposed that the assembly of microtubules is affected by irradiation. It may be the result of an increase in CA('2+) concentration in the tissue after irradiation or an inactivation of the initiation centers. The effects of irradiation on unassembled tubulin or assembled microtubules is negligible. ^
Resumo:
The study is a three-armed randomized controlled trial comparing values for heart rate variability (HRV), a measure of cardiovascular health, throughout a yoga intervention of breast cancer patients undergoing radiotherapy. Patients attended either a yoga (n=45), stretch, (n=46), or control (n=42) condition 3 times per week for 6 weeks of radiation. Electrocardiograms (ECGs) were conducted on each participant to provide the values necessary for HRV analysis. Analyses focused on examining scores for those participants with HRV baseline values considered to be below the cutoff point for healthy HRV levels, defined by the authors as below the cutpoint of 68 ms. From the entire sample of 133 with available baselines, 26 yogis, 26 stretchers, and 23 controls were determined to be “pathologic” in terms of HRV, and selected for follow-up analysis at 3 weeks and then again at 6 weeks. Though no statistically significant differences were found between either group means at each timepoint or group change score means, the yoga group had consistently higher mean score and mean change scores. These findings are suggestive and indicate the need to refine the use of ECGs and HRV analysis programs to more accurately and comprehensively assess the effects of yoga on cardiovascular health in cancer patients.^
Resumo:
Additive and multiplicative models of relative risk were used to measure the effect of cancer misclassification and DS86 random errors on lifetime risk projections in the Life Span Study (LSS) of Hiroshima and Nagasaki atomic bomb survivors. The true number of cancer deaths in each stratum of the cancer mortality cross-classification was estimated using sufficient statistics from the EM algorithm. Average survivor doses in the strata were corrected for DS86 random error ($\sigma$ = 0.45) by use of reduction factors. Poisson regression was used to model the corrected and uncorrected mortality rates with covariates for age at-time-of-bombing, age at-time-of-death and gender. Excess risks were in good agreement with risks in RERF Report 11 (Part 2) and the BEIR-V report. Bias due to DS86 random error typically ranged from $-$15% to $-$30% for both sexes, and all sites and models. The total bias, including diagnostic misclassification, of excess risk of nonleukemia for exposure to 1 Sv from age 18 to 65 under the non-constant relative projection model was $-$37.1% for males and $-$23.3% for females. Total excess risks of leukemia under the relative projection model were biased $-$27.1% for males and $-$43.4% for females. Thus, nonleukemia risks for 1 Sv from ages 18 to 85 (DRREF = 2) increased from 1.91%/Sv to 2.68%/Sv among males and from 3.23%/Sv to 4.02%/Sv among females. Leukemia excess risks increased from 0.87%/Sv to 1.10%/Sv among males and from 0.73%/Sv to 1.04%/Sv among females. Bias was dependent on the gender, site, correction method, exposure profile and projection model considered. Future studies that use LSS data for U.S. nuclear workers may be downwardly biased if lifetime risk projections are not adjusted for random and systematic errors. (Supported by U.S. NRC Grant NRC-04-091-02.) ^
Resumo:
A nested case-control study design was used to investigate the relationship between radiation exposure and brain cancer risk in the United States Air Force (USAF). The cohort consisted of approximately 880,000 men with at least 1 year of service between 1970 and 1989. Two hundred and thirty cases were identified from hospital discharge records with a diagnosis of primary malignant brain tumor (International Classification of Diseases, 9th revision, code 191). Four controls were exactly matched with each case on year of age and race using incidence density sampling. Potential career summary extremely low frequency (ELF) and microwave-radiofrequency (MWRF) radiation exposures were based upon the duration in each occupation and an intensity score assigned by an expert panel. Ionizing radiation (IR) exposures were obtained from personal dosimetry records.^ Relative to the unexposed, the overall age-race adjusted odds ratio (OR) for ELF exposure was 1.39, 95 percent confidence interval (CI) 1.03-1.88. A dose-response was not evident. The same was true for MWRF, although the OR = 1.59, with 95 percent CI 1.18-2.16. Excess risk was not found for IR exposure (OR = 0.66, 45 percent CI 0.26-1.72).^ Increasing socioeconomic status (SES), as identified by military pay grade, was associated with elevated brain tumor risk (officer vs. enlisted personnel age-race adjusted OR = 2.11, 95 percent CI 1.98-3.01, and senior officers vs. all others age-race adjusted OR = 3.30, 95 percent CI 2.0-5.46). SES proved to be an important confounder of the brain tumor risk associated with ELF and MWRF exposure. For ELF, the age-race-SES adjusted OR = 1.28, 95 percent CI 0.94-1.74, and for MWRF, the age-race-SES adjusted OR = 1.39, 95 percent CI 1.01-1.90.^ These results indicate that employment in Air Force occupations with potential electromagnetic field exposures is weakly, though not significantly, associated with increased risk for brain tumors. SES appeared to be the most consistent brain tumor risk factor in the USAF cohort. Other investigators have suggested that an association between brain tumor risk and SES may arise from differential access to medical care. However, in the USAF cohort health care is universally available. This study suggests that some factor other than access to medical care must underlie the association between SES and brain tumor risk. ^
Resumo:
The effect of vitamin A (retinyl acetate) and three hypoxic cell sensitizers (metronidazole, misonidazole and desmethylmisonidazole) on lung tumor development in strain A mice exposed to radiation was assessed.^ In experiments involving vitamin A, two groups of mice were fed a low vitamin A diet (< 100 IU/100g diet) while the two other groups were fed a high vitamin A diet (800 IU/100g diet). After two weeks one group maintained on the high vitamin A diet and one group maintained on the low vitamin A diet were given an acute dose of 500 rad of gamma radiation to the thoracic region. The circulating level of plasma vitamin A in all four groups of mice was monitored. A difference in circulating vitamin A in the mice maintained on high and low vitamin A diet became evident by 20 weeks and continued for the duration of the experiment. Mice were killed 18, 26, and 40 weeks post irradiation, their lungs were removed and the number of surface adenomas were counted. There was a significant increase in the number of mice bearing lung tumors and the mean number of lung tumors per mouse in the irradiated group maintained on the high vitamin A diet at 40 weeks post irradiation as compared to the irradiated group maintained on a low vitamin A diet (p < 0.05). Under the conditions of this experiment the development of pulmonary adenomas in irradiated strain A mice appears to relate directly to circulating levels of vitamin A.^ In the other experiment two dose levels of the hypoxic cell sensitizers, 0.2mg/g and 0.6mg/g, were used either alone or in combination with 900 rad of gamma radiation in a fractionated dose schedule of twice a week for three weeks. In the groups of mice which received hypoxic cell sensitizers only, the prevalence and the mean number of lung tumors per mouse were somewhat increased (p < 0.10) in the higher dose group (0.6mg/g) of misonidazole but was not significantly different from the control animals in the other two sensitizer groups. The combination of hypoxic cell sensitizer and radiation did not show any significant enhancement of lung tumor response when compared with the group which received radiation only. The dose of radiation used in this study significantly enhanced lung tumor formation in mice when compared with the control group. Thus, under the experimental exposure conditions used in this investigation, which were very similar to the exposure conditions occurring in clinical treatment, all three hypoxic cell sensitizers did not sensitize the mouse to the carcinogenic effects of gamma radiation.^
Resumo:
Background: The Medical Education Partnership Initiative, has helped to mitigate the digital divide in Africa. The aim of the study was to assess the level of access, attitude, and training concerning meaningful use of electronic resources and EBM among medical students at an African medical school. Methods: The study involved medical students at the University of Zimbabwe College of Health Sciences, Harare. The needs assessment tool consisted of a 21-question, paper-based, voluntary and anonymous survey. Results: A total of 61/67 (91%), responded to the survey. 60% of the medical students were ‘third-year medical students’. Among medical students, 85% of responders had access to digital medical resources, but 54% still preferred printed medical textbooks. Although 25% of responders had received training in EBM, but only 7% found it adequate. 98% of the participants did not receive formal training in journal club presentation or analytical reading of medical literature, but 77 % of them showed interest in learning these skills. Conclusion: Lack of training in EBM, journal club presentation and analytical reading skills have limited the impact of upgraded technology in enhancing the level of knowledge. This impact can be boosted by developing a curriculum with skills necessary in using EBM.
Resumo:
Introduction A novel realistic 3D virtual reality (VR) application has been developed to allow medical imaging students at Queensland University of Technology to practice radiographic techniques independently outside the usual radiography laboratory. Methods A flexible agile development methodology was used to create the software rapidly and effectively. A 3D gaming environment and realistic models were used to engender presence in the software while tutor-determined gold standards enabled students to compare their performance and learn in a problem-based learning pedagogy. Results Students reported high levels of satisfaction and perceived value and the software enabled up to 40 concurrent users to prepare for clinical practice. Student feedback also indicated that they found 3D to be of limited value in the desktop version compared to the usual 2D approach. A randomised comparison between groups receiving software-based and traditional practice measured performance in a formative role play with real equipment. The results of this work indicated superior performance with the equipment for the VR trained students (P = 0.0366) and confirmed the value of VR for enhancing 3D equipment-based problem-solving skills. Conclusions Students practising projection techniques virtually performed better at role play assessments than students practising in a traditional radiography laboratory only. The application particularly helped with 3D equipment configuration, suggesting that teaching 3D problem solving is an ideal use of such medical equipment simulators. Ongoing development work aims to establish the role of VR software in preparing students for clinical practice with a range of medical imaging equipment.