924 resultados para Hand-held
Resumo:
This study aimed to determine the accuracy (and usability) of the Retinomax, a hand-held autorefractor, compared to measurements taken from hand-held retinoscopy (HHR) in a sample of normal 1-year-old children. The study was a method comparison set at four Community Child Health Clinics. Infants (n = 2079) of approximately 1 year of age were identified from birth/immunization records and their caregivers were contacted by mail. A total of 327 infants ranging in age from 46 weeks to 81 weeks (mean 61 weeks) participated in the study. The children underwent a full ophthalmic examination. Under cycloplegia, refraction was measured in each eye by streak retinoscopy (HHR) and then re-measured using the Retinomax autorefractor. Sphere, cylinder, axis of cylinder and spherical equivalent measurements were recorded for HHR and Retinomax instruments, and compared. Across the range of refractive errors measured, there was generally close agreement between the two examination methods, although the Retinomax consistently read around 0.3 D less hyperopic than HHR. Significantly more girls (72 infants, 47.7%), struggled during examination with the Retinomax than boys (52 infants, 29.5%) (P < 0.001). Agreement deteriorated between the two instruments if the patient struggled during the examination (P < 0.001). In general, the Retinomax would appear to be a useful screening instrument in early childhood. However, patient cooperation affects the accuracy of results and is an important con-sideration in determining whether this screening instrument should be adopted for measuring refractive errors in early infancy.
Resumo:
A unique hand-held gene gun is employed for ballistically delivering biomolecules to key cells in the skin and mucosa in the treatment of the major diseases. One of these types of devices, called the Contoured Shock Tube (CST), delivers powdered micro-particles to the skin with a narrow and highly controllable velocity distribution and a nominally uniform spatial distribution. In this paper, we apply a numerical approach to gain new insights in to the behavior of the CST prototype device. The drag correlations proposed by Henderson (1976), Igra and Takayama (1993) and Kurian and Das (1997) were applied to predict the micro-particle transport in a numerically simulated gas flow. Simulated pressure histories agree well with the corresponding static and Pitot pressure measurements, validating the CFD approach. The calculated velocity distributions show a good agreement, with the best prediction from Igra & Takayama correlation (maximum discrepancy of 5%). Key features of the gas dynamics and gas-particle interaction are discussed. Statistic analyses show a tight free-jet particle velocity distribution is achieved (570 +/- 14.7 m/s) for polystyrene particles (39 +/- 1 mu m), representative of a drug payload.
Resumo:
Fluorescence-enhanced optical imaging is an emerging non-invasive and non-ionizing modality towards breast cancer diagnosis. Various optical imaging systems are currently available, although most of them are limited by bulky instrumentation, or their inability to flexibly image different tissue volumes and shapes. Hand-held based optical imaging systems are a recent development for its improved portability, but are currently limited only to surface mapping. Herein, a novel optical imager, consisting primarily of a hand-held probe and a gain-modulated intensified charge coupled device (ICCD) detector, is developed towards both surface and tomographic breast imaging. The unique features of this hand-held probe based optical imager are its ability to; (i) image large tissue areas (5×10 sq. cm) in a single scan, (ii) reduce overall imaging time using a unique measurement geometry, and (iii) perform tomographic imaging for tumor three-dimensional (3-D) localization. Frequency-domain based experimental phantom studies have been performed on slab geometries (650 ml) under different target depths (1-2.5 cm), target volumes (0.45, 0.23 and 0.10 cc), fluorescence absorption contrast ratios (1:0, 1000:1 to 5:1), and number of targets (up to 3), using Indocyanine Green (ICG) as fluorescence contrast agents. An approximate extended Kalman filter based inverse algorithm has been adapted towards 3-D tomographic reconstructions. Single fluorescence target(s) was reconstructed when located: (i) up to 2.5 cm deep (at 1:0 contrast ratio) and 1.5 cm deep (up to 10:1 contrast ratio) for 0.45 cc-target; and (ii) 1.5 cm deep for target as small as 0.10 cc at 1:0 contrast ratio. In the case of multiple targets, two targets as close as 0.7 cm were tomographically resolved when located 1.5 cm deep. It was observed that performing multi-projection (here dual) based tomographic imaging using a priori target information from surface images, improved the target depth recovery over using single projection based imaging. From a total of 98 experimental phantom studies, the sensitivity and specificity of the imager was estimated as 81-86% and 43-50%, respectively. With 3-D tomographic imaging successfully demonstrated for the first time using a hand-held based optical imager, the clinical translation of this technology is promising upon further experimental validation from in-vitro and in-vivo studies.
Resumo:
Optical imaging is an emerging technology towards non-invasive breast cancer diagnostics. In recent years, portable and patient comfortable hand-held optical imagers are developed towards two-dimensional (2D) tumor detections. However, these imagers are not capable of three-dimensional (3D) tomography because they cannot register the positional information of the hand-held probe onto the imaged tissue. A hand-held optical imager has been developed in our Optical Imaging Laboratory with 3D tomography capabilities, as demonstrated from tissue phantom studies. The overall goal of my dissertation is towards the translation of our imager to the clinical setting for 3D tomographic imaging in human breast tissues. A systematic experimental approach was designed and executed as follows: (i) fast 2D imaging, (ii) coregistered imaging, and (iii) 3D tomographic imaging studies. (i) Fast 2D imaging was initially demonstrated in tissue phantoms (1% Liposyn solution) and in vitro (minced chicken breast and 1% Liposyn). A 0.45 cm3 fluorescent target at 1:0 contrast ratio was detectable up to 2.5 cm deep. Fast 2D imaging experiments performed in vivo with healthy female subjects also detected a 0.45 cm3 fluorescent target superficially placed ∼2.5 cm under the breast tissue. (ii) Coregistered imaging was automated and validated in phantoms with ∼0.19 cm error in the probe’s positional information. Coregistration also improved the target depth detection to 3.5 cm, from multi-location imaging approach. Coregistered imaging was further validated in-vivo , although the error in probe’s positional information increased to ∼0.9 cm (subject to soft tissue deformation and movement). (iii) Three-dimensional tomography studies were successfully demonstrated in vitro using 0.45 cm3 fluorescence targets. The feasibility of 3D tomography was demonstrated for the first time in breast tissues using the hand-held optical imager, wherein a 0.45 cm3 fluorescent target (superficially placed) was recovered along with artifacts. Diffuse optical imaging studies were performed in two breast cancer patients with invasive ductal carcinoma. The images showed greater absorption at the tumor cites (as observed from x-ray mammography, ultrasound, and/or MRI). In summary, my dissertation demonstrated the potential of a hand-held optical imager towards 2D breast tumor detection and 3D breast tomography, holding a promise for extensive clinical translational efforts.
Resumo:
According to the American Podiatric Medical Association, about 15 percent of the patients with diabetes would develop a diabetic foot ulcer. Furthermore, foot ulcerations leads to 85 percent of the diabetes-related amputations. Foot ulcers are caused due to a combination of factors, such as lack of feeling in the foot, poor circulation, foot deformities and the duration of the diabetes. To date, the wounds are inspected visually to monitor the wound healing, without any objective imaging approach to look before the wound’s surface. Herein, a non-contact, portable handheld optical device was developed at the Optical Imaging Laboratory as an objective approach to monitor wound healing in foot ulcer. This near-infrared optical technology is non-radiative, safe and fast in imaging large wounds on patients. The FIU IRB-approved study will involve subjects that have been diagnosed with diabetes by a physician and who have developed foot ulcers. Currently, in-vivo imaging studies are carried out every week on diabetic patients with foot ulcers at two clinical sites in Miami. Near-infrared images of the wound are captured on subjects every week and the data is processed using customdeveloped Matlab-based image processing tools. The optical contrast of the wound to its peripheries and the wound size are analyzed and compared from the NIR and white light images during the weekly systematic imaging of wound healing.
Resumo:
OBJECTIVES: To test the validity of a simple, rapid, field-adapted, portable hand-held impedancemeter (HHI) for the estimation of lean body mass (LBM) and percentage body fat (%BF) in African women, and to develop specific predictive equations. DESIGN: Cross-sectional observational study. SETTINGS: Dakar, the capital city of Senegal, West Africa. SUBJECTS: A total sample of 146 women volunteered. Their mean age was of 31.0 y (s.d. 9.1), weight 60.9 kg (s.d. 13.1) and BMI 22.6 kg/m(2) (s.d. 4.5). METHODS: Body composition values estimated by HHI were compared to those measured by whole body densitometry performed by air displacement plethysmography (ADP). The specific density of LBM in black subjects was taken into account for the calculation of %BF from body density. RESULTS: : Estimations from HHI showed a large bias (mean difference) of 5.6 kg LBM (P<10(-4)) and -8.8 %BF (P<10(-4)) and errors (s.d. of the bias) of 2.6 kg LBM and 3.7 %BF. In order to correct for the bias, specific predictive equations were developed. With the HHI result as a single predictor, error values were of 1.9 kg LBM and 3.7 %BF in the prediction group (n=100), and of 2.2 kg LBM and 3.6 %BF in the cross-validation group (n=46). Addition of anthropometrical predictors was not necessary. CONCLUSIONS: The HHI analyser significantly overestimated LBM and underestimated %BF in African women. After correction for the bias, the body compartments could easily be estimated in African women by using the HHI result in an appropriate prediction equation with a good precision. It remains to be seen whether a combination of arm and leg impedancemetry in order to take into account lower limbs would further improve the prediction of body composition in Africans.
Resumo:
Abstract: Students who are actively involved in the learning process tend to develop deeper knowledge than those in traditional lecture classrooms (Beatty, 2007; Crouch & Mazur, 2001; Hake, 1998; Richardson, 2003). An instructional strategy that promotes active involvement is Peer Instruction. This strategy encourages student engagement by asking them to respond to conceptual multiple-choice questions intermittently throughout the lecture. These questions can be responded to by using an electronic hand-held device commonly known as a clicker that enables students’ responses to be displayed on a screen. When clickers are not available, a show of hands or other means can be used. The literature suggests that the impact on student learning is the same, whether the teacher uses clickers or simply asks students to raise their hand or use flashcards when responding to the questions (Lasry, 2007). This critical analysis argues that using clickers to respond to these in-class conceptual multiple-choice questions as opposed to using a show of hands leads to deeper conceptual understanding, better performance on tests, and greater overall enjoyment during class.||Résumé: Les étudiants qui sont activement impliqués dans le processus d'apprentissage ont tendance à développer des connaissances plus approfondies que lors de cours traditionnels (Beatty, 2007; Crouch & Mazur, 2001; Hake, 1998; Richardson, 2003). Une stratégie d'enseignement qui favorise la participation active est l’apprentissage par les pairs. Cette stratégie d’enseignement encourage l'engagement des élèves en leur demandant de répondre à des questions à choix multiples conceptuelles à plusieurs reprises durant le déroulement du cours. Ces questions peuvent être répondues à l'aide d'un appareil portatif électronique (un « clicker ») qui permet d’afficher de façon anonyme les réponses des élèves sur un écran. Si les clickers ne sont pas disponibles, les étudiants peuvent aussi répondre aux questions en levant la main. La littérature suggère que la méthode utilisée n’a pas d’impact sur l'apprentissage des élèves, que l'enseignant utilise des clickers, des flashcards ou qu’il demande simplement aux élèves de lever la main pour répondre aux questions (Lasry, 2007). Cette analyse critique fait valoir que l'utilisation de clickers pour répondre à ces questions à choix multiples conceptuelles en classe, plutôt que de faire lever la main aux étudiants, résulte en une compréhension conceptuelle plus approfondie, une meilleure performance aux examens et plus de plaisir pendant les cours.
Resumo:
A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.
Resumo:
Traditional field sampling approaches for ecological studies of restored habitat can only cover small areas in detail, con be time consuming, and are often invasive and destructive. Spatially extensive and non-invasive remotely sensed data can make field sampling more focused and efficient. The objective of this work was to investigate the feasibility and accuracy of hand-held and airborne remotely sensed data to estimate vegetation structural parameters for an indicator plant species in a restored wetland. High spatial resolution, digital, multispectral camera images were captured from an aircraft over Sweetwater Marsh (San Diego County, California) during each growing season between 1992-1996. Field data were collected concurrently, which included plant heights, proportional ground cover and canopy architecture type, and spectral radiometer measurements. Spartina foliosa (Pacific cordgrass) is the indicator species for the restoration monitoring. A conceptual model summarizing the controls on the spectral reflectance properties of Pacific cordgrass was established. Empirical models were developed relating the stem length, density, and canopy architecture of cordgrass to normalized-difference-vegetation-index values. The most promising results were obtained from empirical estimates of total ground cover using image data that had been stratified into high, middle, and low marsh zones. As part of on-going restoration monitoring activities, this model is being used to provide maps of estimated vegetation cover.
Resumo:
In the present study, we used the electronic version of the von Frey test to investigate the role of cytokines (TNF-alpha and IL-1 beta) and chemokines (KC/CXCL-1) in the genesis of mechanical hypernociception during antigen-induced inflammation in mice. The nociceptive test consisted of evoking a hindpaw flexion reflex with a hand-held force transducer (electronic anesthesiometer) adapted with a 0.5 mm(2) polypropylene tip. The intraplantar administration of methylated bovine serum albumin (mBSA) in previously immunized (IM), but not in sham-immunized (SI) mice, induced mechanical hypernociception in a dose-dependant manner. Hypernociception induced by antigen was reduced in animals pretreated with IL-lra and reparixin (a non-competitive allosteric inhibitor of CXCR2), and in TNF receptor type 1 deficient (TNFR1-/-) mice. Consistently, antigen challenge induced a time-dependent release of TNF-alpha, IL-1 beta and KC/CXCL-1 in IM, but not in SI, mice. Consistently, antigen challenge induced a time-dependent release of TNF-alpha, IL-1 beta and KC/CXCL-1 in IM, but not in SI, mice. The increase in TNF-alpha levels preceded the increase in IL-1 beta and KC/CXCL1. Antigen-induced release of IL-1 beta and KC/CXCL1 was reduced in TNFR1-/- mice, and TNF-alpha induced hypernociception was inhibited by IL-lra and reparixin. Hypernociception induced by IL-1 beta in immunized mice was inhibited by indomethacin, whereas KC/CXCL1-induced hypernociception was inhibited by indomethacin and guanethidine, Antigen-induced hypernociception was reduced by indomethacin and guanethidine and abolished by the two drugs combined. Together, these results suggest that inflammation associated with an adaptive immune response induces hypernociception that is mediated by an initial release of TNF-alpha, which triggers that subsequent release of IL-1 beta and KC/CXCL1. The latter cytokines in turn stimulate the release of the direct-acting final mediator, prostanoids and sympathetic amines. (C) 2008 European Federation of Chapters of the International Association for the Study of Pain. Published by Elsevier Ltd. All rights reserved.
Resumo:
Birth has been observed in a number of marsupial species and, in the studies to date, the newborn have crawled up to or across to the pouch. The method of birth in the quoll, a dasyurid, differs greatly from that observed in other marsupials. Births were recorded at normal speed using hand-held digital video cameras. Birth was heralded by a release of about 1 mL of watery fluid from the urogenital sinus followed by gelatinous material contained in either one or two tubes emanating from the sinus. The newborn, still encased in their placental membranes, were in the gelatinous material within a column. To exit this column, they had to grasp a hair and wriggle about 1 cm across to the pouch. In the pouch the newborn young had to compete for a teat. Although the quolls possessed 8 teats, the number of young in the pouch immediately after birth was 17, 16, 6, 16, 13 and 11 for each of the 6 quolls filmed. While birth has been described previously in another two dasyurids, the observers did not describe birth as reported here for the quoll. Nevertheless the movement of the newborn from the sinus to the pouch is so quick that this could have previously been missed. Filming birth from beneath and from the side allowed for a greater understanding of the birth process. Further studies are required to determine whether this use of a gelatinous material is part of the birth process in all dasyurids.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
Introdução: A aplicação das técnicas de Contrair-Relaxar com Contracção do Antagonista (CRCA) e de Músculo Energia (TME) promovem um aumento da flexibilidade muscular, contudo poucos estudos comparam a eficácia de ambas. Apresentam aspectos comuns como a contracção prévia do músculo a alongar sendo esta máxima na CRCA e uma percentagem da máxima na TME. Contudo, alguma evidência sugere que não existe correspondência entre a força produzida e a desejada pelo que este aspecto da TME carece de explicação. Objectivos: Confirmar se a técnica CRCA e a TME são efectivas no alongamento muscular dos isquiotibiais a curto prazo, caso sejam determinar qual a mais efectiva. Pretende-se ainda avaliar se a percepção ao esforço durante a aplicação da TME corresponde à força efectivamente realizada. Métodos: Efectuou-se um estudo experimental com 45 voluntários distribuídos aleatoriamente pelos grupos CRCA, TME e Controlo. Avaliou-se a amplitude articular passiva de extensão do joelho antes e depois de aplicar as técnicas, utilizando um goniómetro. Nos participantes submetidos à TME avaliou-se a percepção ao esforço, solicitando uma contracção submáxima isométrica de 40% medida através do dinamómetro de mão. Resultados: Verificou-se um efeito das técnicas entre as avaliações (Teste ANOVA medidas repetidas factor tempo: p<0,001) e entre os grupos (tempo*grupo: p<0,001). Comparando os grupos dois a dois, verificaram-se diferenças entre o grupo CRCA e o grupo Controlo (Teste Post Hoc Games-Howell: p=0,001) e entre o grupo TME e o grupo Controlo (p=0,009), não existindo diferenças entre os grupos CRCA e TME (p=0,376). Os grupos CRCA e TME obtiveram um ganho de 10,7º e de 11,4º respectivamente, não havendo diferenças significativas entre os ganhos (Teste T-Student Independente: p=0,599). Existiram diferenças significativas entre os 40% CMVI produzida e desejada (Teste Wilcoxon: p=0,018). Conclusão: Ambas foram efectivas no aumento da flexibilidade muscular dos isquiotibiais a curto prazo. Os efeitos foram comparáveis, mas dada a menor complexidade e menor solicitação a TME foi considerada mais eficiente. A percepção ao esforço durante a aplicação da TME não correspondeu ao esforço desejado, existindo uma tendência para a produção de intensidades de contracções maiores.
Resumo:
This paper describes how to extend the access to remote experiments from mobile devices, aiming to better engage digital native students who expect a more interactive and ubiquitous access mode. The extension is based on features of HTML5 and the jQuery Mobile framework, which allow accessing the experiments from different operating systems via the browser or native applications. As a result, users have a richer interaction mode with the experiments, which includes access from simple hand-held devices such as smartphones and PDAs. Extending the access to remote experiments, from simple devices, enables its use in other educational stages, such as high schools, where teachers struggle to engage students in STEM learning. By enabling students to use their everyday "technological companions", e.g. cellular phones, to access remote experiments, we seek to increase the educational value of this technology-enhanced learning resource.