999 resultados para Halogen light
Resumo:
This study evaluated the Knoop hardness and polymerization depth of a dual-cured resin cement, light-activated at different distances through different thicknesses of composite resin. One bovine incisor was embedded in resin and its buccal surface was flattened. Dentin was covered with PVC film where a mold (0.8-mm-thick and 5 mm diameter) was filled with cement and covered with another PVC film. Light curing (40 s) was carried out through resin discs (2, 3, 4 or 5 mm) with a halogen light positioned 0, 1, 2 or 3 mm from the resin surface. After storage, specimens were sectioned for hardness measurements (top, center, and bottom). Data were subjected to split-plot ANOVA and Tukey's test (α=0.05). The increase in resin disc thickness decreased cement hardness. The increase in the distance of the light curing tip decreased hardness at the top region. Specimens showed the lowest hardness values at the bottom, and the highest at the center. Resin cement hardness was influenced by the thickness of the indirect restoration and by the distance between the light-curing unit tip and the resin cement surface.
Resumo:
The aim of this study was to evaluate the effect of tooth bleaching with 10% carbamide peroxide (CP) or 35% hydrogen peroxide (HP), with or without quartz-tungsten-halogen light or hybrid source LED/infrared laser exposition on the occurrence duration, intensity and location of tooth sensitivity Forty patients were selected and randomly divided into four groups: GI--home bleaching with CP for 4 hours a day, over the course of 3 weeks; GII--three sessions of HP with three 10-minute applications at each session and no light source; GIII--the same procedure as GII with quartz-tungsten-halogen light irradiation; GIV--the same procedure as GII with LED/laser light irradiation. The evaluation included an appointment with each patient before and after each HP bleaching session or each weekly CP bleaching and 7, 30 and 180 days after the end of treatment. The Kruskal-Wallis test revealed that the duration and intensity of post-treatment sensitivity were significantly higher for HP than for CP (p< 0.05), and symptoms were located predominantly in anterior teeth. All bleaching methods generated sensitivity, which was more frequent in anterior teeth. However, treatment with CP generated lower sensitivity than treatment with HP independently of the light sources.
Resumo:
The aim of this study was to evaluate the effects of different light-curing units and resin cement curing types on the bond durability of a feldspathic ceramic bonded to dentin. The crowns of 40 human molars were sectioned, exposing the dentin. Forty ceramic blocks of VITA VM7 were produced according to the manufacturer's recommendations. The ceramic surface was etched with 10% hydrofluoric acid/60s and silanized. The dentin was treated with37% phosphoric acid/15s, and the adhesive was applied. The ceramic blocks were divided and cemented to dentin according to resin cement/RC curing type(dual-and photocured), light-curing unit (halogen light/QTH and LED), and storage conditions (dry and storage/150 days + 12,000 cycles/thermocycling). All blocks were stored in distilled water (37°C/24h) and sectioned (n = 10): G1-QTH + RC Photo, G2-QTH + RC Dual, G3-LED + RC Photo, G4-LED + RC Dual. Groups G5, G6, G7, and G8 were obtained exactly as G1 through G4, respectively, and then stored and thermocycled. Microtensile bond strength tests were performed (EMIC), and data were statistically analyzed by ANOVA and Tukey's test (5%). The bond strength values (MPa) were: G1-12.95 (6.40)ab; G2-12.02 (4.59)ab; G3-13.09 (5.62)ab; G4-15.96 (6.32)a; G5-6.22 (5.90)c; G6-9.48 (5.99)bc; G7-12.78 (11.30)ab; and G8-8.34 (5.98)bc. The same superscript letters indicate no significant differences. Different light-curing units affected the bond strength betweenceramic cemented to dentin when the photocured cement was used, and only after aging (LED>QTH). There was no difference between the effects of dual-and photo-cured resin-luting agents on the microtensile bond strength of the cement used in this study.
Resumo:
The aim of this study was to evaluate the influence of different curing lights and chemical catalysts on the degree of conversion of resin luting cements. A total of 60 disk-shaped specimens of RelyX ARC or Panavia F of diameter 5 mm and thickness 0.5 mm were prepared and the respective chemical catalyst (Scotchbond Multi-Purpose Plus or ED Primer) was added. The specimens were light-cured using different curing units (an argon ion laser, an LED or a quartz-tungsten-halogen light) through shade A2 composite disks of diameter 10 mm and thickness 2 mm. After 24 h of dry storage at 37A degrees C, the degree of conversion of the resin luting cements was measured by Fourier-transformed infrared spectroscopy. For statistical analysis, ANOVA and the Tukey test were used, with p a parts per thousand currency signaEuro parts per thousand 0.05. Panavia F when used without catalyst and cured using the LED or the argon ion laser showed degree of conversion values significantly lower than RelyX ARC, with and without catalyst, and cured with any of the light sources. Therefore, the degree of conversion of Panavia F with ED Primer cured with the quartz-tungsten-halogen light was significantly different from that of RelyX ARC regardless of the use of the chemical catalyst and light curing source. In conclusion, RelyX ARC can be cured satisfactorily with the argon ion laser, LED or quartz-tungsten-halogen light with or without a chemical catalyst. To obtain a satisfactory degree of conversion, Panavia F luting cement should be used with ED Primer and cured with halogen light.
Resumo:
Predictive models based on near infra-red spectroscopy for the assessment of fruit internal quality attributes must exhibit a degree of robustness across the parameters of variety, district and time to be of practical use in fruit grading. At the time this thesis was initiated, while there were a number of published reports on the development of near infra-red based calibration models for the assessment of internal quality attributes of intact fruit, there were no reports of the reliability ("robustness") of such models across time, cultivars or growing regions. As existing published reports varied in instrumentation employed, a re-analysis of existing data was not possible. An instrument platform, based on partial transmittance optics, a halogen light source and (Zeiss MMS 1) detector operating in the short wavelength near infra-red region was developed for use in the assessment of intact fruit. This platform was used to assess populations of macadamia kernels, melons and mandarin fruit for total soluble solids, dry matter and oil concentration. Calibration procedures were optimised and robustness assessed across growing areas, time of harvest, season and variety. In general, global modified partial least squares regression (MPLS) calibration models based on derivatised absorbance data were better than either multiple linear regression or `local' MPLS models in the prediction of independent validation populations . Robustness was most affected by growing season, relative to the growing district or variety . Various calibration updating procedures were evaluated in terms of calibration robustness. Random selection of samples from the validation population for addition to the calibration population was equivalent to or better than other methods of sample addition (methods based on the Mahalanobis distance of samples from either the centroid of the population or neighbourhood samples). In these exercises the global Mahalanobis distance (GH) was calculated using the scores and loadings from the calibration population on the independent validation population. In practice, it is recommended that model predictive performance be monitored in terms of predicted sample GH, with model updating using as few as 10 samples from the new population undertaken when the average GH value exceeds 1 .0 .
Resumo:
Este estudo teve por objetivo avaliar, in vitro, a influência do material de confecção das matrizes, traçando um perfil da conversão monomérica de um compósito micro-híbrido, além de avaliar qual dos materiais testados mais se assemelha a uma matriz de dentina. A avaliação foi feita através da análise do grau de conversão (GC). Foram confeccionadas 3 matrizes bipartidas, sendo estas de teflon negro, tefon branco e aço inoxidável, ambas com 10mm de diâmetro e 2 mm de profundidade. Para o grupo controle foi utilizado um incisivo central bovino, o qual teve sua face vestibular aplainada em uma lixadeira sob refrigeração constante, com o auxílio de uma lixa de carbeto de silício, número 800. Após, este dente foi preparado com uma broca diamantada número 2294 (KG Sorensen) em alta rotação, própria para a preparação de cavidades padronizadas para ensaios de laboratório, apresentando um limitador de penetração. Em seguida, com um motor de baixa rotação foi realizado o acabamento das paredes, obtendo-se uma cavidade de 2,0 mm de profundidade por 9,0 mm de diâmetro. Pela palatina desse dente, com uma broca carbide cilíndrica de numeração 2056 (KG Sorensen), fez-se uma penetração até se obter uma parede de dentina extremamente fina, porém sem que esta fosse rompida. Assim, com uma agulha, fez-se uma pequena perfuração no centro dessa dentina para que este instrumental servisse como um pino para remoção do corpo de prova de dentro da matriz de dente. Os corpos de prova (CP) foram obtidos a partir da inserção do compósito no interior da perfuração das matrizes em um único incremento e cobertos na superfície externa com uma matriz de poliéster mais uma lamínula de vidro. Os CP foram fotopolimerizados por 40 s pela fonte de luz halógena Optilux 501 (Demetron), com 500 mW/cm. Imediatamente após a polimerização, os corpos de prova eram submetidos no topo e na base para a análise de espectrometria no infravermelho para a determinação da profundidade de polimerização, pela técnica do filme vazado para o compósito não polimerizado e pela técnica da pastilha de brometo de potássio (KBr) para o compósito polimerizado. Foram confeccionados 5 CP de cada grupo. Em cada grupo, o compósito da base e do topo das amostras foi moído até se obter de 1,5 a 2,0 mg de pó e misturado com 70 mg de KBr, para obtenção da pastilha de KBr. Foi feita a análise de espectrofotometria no infravermelho por Transformada de Fourier (FTIR). As absorções selecionadas para o cálculo foram 1610 cm-1 e 1637 cm-1, os picos dos espectros das ligações dos carbonos aromáticos e alifáticos, respectivamente. Os dados obtidos foram tratados estatisticamente. Os grupos Gr1B, Gr2B, Gr3B e Gr4B representam, respectivamente, as bases dos CP confeccionados pelas matrizes de DB, TN, TB e AI. Já os Gr1T, Gr2T, Gr3T e Gr4T representam os topos. Médias (%) e DP: Gr1T (46,461,99), Gr2T (39,864,51), Gr3T (44,053,44) e Gr4T (38,045,08). Gr1B (40,441,49), Gr2B (36,153,81), Gr3B (40,093,18) e Gr4B (35,593,35). Em posse dos resultados, pôde-se concluir que os grupos do teflon negro, teflon branco e aço inoxidável não apresentaram diferenças entre o grau de conversão do topo e da base, enquanto que o grupo da dentina apresentou maior conversão do topo. Comparando as matrizes entre elas, pôde-se perceber que no topo, o GC do dente bovino é maior que o GC do aço inoxidável e do que o de teflon negro, o GC do teflon branco é maior que o GC do aço inoxidável e do que o de teflon negro. Já o topo dos grupos de dente bovino e teflon banco foram semelhantes. Nas bases dos CPs, não houve diferença significativa entre os grupos testados. De acordo com os resultados obtidos no experimento, pôde-se concluir que nos grupos do teflon negro, teflon branco e aço inoxidável não houve diferença entre 0 e 2 mm, ou seja, topo e base, o que mostra que o material de confecção da matriz não influênciou o grau de conversão do compósito. Já para o grupo da matriz de dentina, o topo apresentou valor de conversão monomérica maior, mostrando que, neste caso, o material da matriz interferiu no grau de conversão. Pode-se perceber também que existe uma tendência da matriz de teflon branco se assemelhar mais a matriz de dentina, pois foi o único grupo que apresentou semelhança nos valores de conversão monomérica no topo das amostras. Porém analisando a base das amostras, percebe-se que todos os grupos se comportaram de forma semelhante, obtendo valores do grau de conversão sem diferença significante.
Resumo:
Photodynamic therapy (PDT) has been proposed as an alternative method for the treatment of biofilm-dependent oral diseases like dental caries. This therapy consists of simultaneous action of a visible light (L) and a photosensitizer (FS) in the presence of oxygen, which leads to production of different reactive oxygen species that can interact with the bacterial cell components, and promote cell death. This study aims to evaluate the antimicrobial action of PDT on oral bacteria in suspension, as well as the formation of mono and multi-species biofilms, in vitro, from a standard strain of Streptococcus mutans (ATCC 25175) and saliva samples, respectively. The dye methylene blue (MB) and toluidine blue (TB) were used at a concentration of 100 mg/ L and activated by halogen light (600 to 750 nm) from a modified hand held photopolymerizer (Ultralux ®, Dabi Atlante, Ribeirão Preto , São Paulo, Brazil.). Planktonic cultures were prepared and submitted to different experimental conditions: 1. PDT using TB 2. PDT using MB, 3. L+ FS- , 4. TB + L - ; 5. MB+ L-; 6. L- FS- (negative control) and 7. administration of 0.12% chlorhexidine digluconate (positive control) (Periogard ®, Colgate-Palmolive Company, New York, USA). The immediate and mediated action of PDT on bacterial suspensions, as well as its effect on biofilm formation were observed from the number of colony-forming units per milliliter (CFU/mL) and measures optical density (OD). The data were statistically analyzed using the Kruskal-Wallis and Mann-Whitney test for the significance level of 5%. According to the results, the PDT showed no antibacterial action on suspensions of S. mutans, regardless of the dye used. PDT with MB activated by halogen light was able to reduce 86.6% CFU/mL multi-species planktonic cultures, however, this reduction was not significant (p > 0.05). PDT showed antibacterial effect, mediate on multi-species planktonic cultures with TB (p < 0.001) and MB (p < 0.001), activated by halogen light. PDT was able to prevent the formation of multispecies biofilm, through the activation of TB by halogen light (p = 0.01). We conclude that activation of the dye toluidine blue and methylene blue, by halogen light (PDT) showed antimicrobial activity, compared to multi-species planktonic cultures prepared from saliva samples
Resumo:
The aims of this in vivo study were to compare the effectiveness and color stability of at-home and in-office bleaching techniques and to evaluate whether the use of light sources can alter bleaching results. According to preestablished criteria, 40 patients were selected and randomly divided into four groups according to bleaching treatment: (1) at-home bleaching with 10% carbamide peroxide, (2) in-office bleaching with 35% hydrogen peroxide (HP) without a light source, (3) in-office bleaching with 35% HP with quartz-tungsten-halogen light, and (4) in-office bleaching with 35% HP with a light-emitting diode/laser. Tooth shade was evaluated using the VITA Classical Shade Guide before bleaching as well as after the first and third weeks of bleaching. Tooth shade was evaluated again using the same guide 1 and 6 months after the completion of treatment. The shade guide was arranged to yield scores that were used for statistical comparison. Statistical analysis using the Kruskal-Wallis test showed no significant differences among the groups for any time point (P > .01). There was no color rebound in any of the groups. The bleaching techniques tested were equally effective. Light sources are unnecessary to bleach teeth. (Int J Periodontics Restorative Dent 2012;32:303-309.)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. This study evaluated transenamel and transdentinal cytotoxic effects of a bleaching gel on the MDPC-23 cell line.Study design. Discs obtained from bovine incisors were placed in a metallic device to simulate an in vivo pulp chamber. Groups were formed according to the enamel surface treatment: G1: 35% H(2)O(2) bleaching gel; G2: 35% H2O2 bleaching gel + halogen light; G3: halogen light; and G4: control. Cell metabolism was evaluated by the methyltetrazolium assay and cell morphology by scanning electron microscopy.Results. Cell metabolism decreased by 31.7%, 41.6%, and 11.5% in G1, G2, and G3, respectively. Cytotoxic effects observed in G2 were significantly more severe compared with G3 and G4. In G1 and G2, a smaller number of viable cells with major morphologic alterations remained adhered to dentin.Conclusion. The bleaching gel associated with light presented transenamel and transdentinal cytotoxic effects characterised by direct damage to odontoblasts and decrease of their metabolic activity. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 458-464)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
To evaluate the trans-enamel and trans-dentinal cytotoxic effects of a 35% H2O2 bleaching gel on an odontoblast-like cell lines (MDPC-23) after consecutive applications.Fifteen enamel/dentine discs were obtained from bovine central incisor teeth and placed individually in artificial pulp chambers. Three groups (n = 5 discs) were formed according to the following enamel treatments: G1: 35% H2O2 bleaching gel (15 min); G2: 35% H2O2 bleaching gel (15 min) + halogen light (20 s); G3: control (no treatment). After repeating the treatments three consecutive times, the extracts (culture medium + gel components that had diffused through enamel/dentine discs) in contact with the dentine were collected and applied to previously cultured MDPC-23 cells (50 000 cells cm(-2)) for 24 h. Cell metabolism was evaluated by the MTT assay and data were analysed statistically (alpha = 5%; Kruskal-Wallis and Mann-Whitney U-test). Cell morphology was analysed by scanning electron microscopy.Cell metabolism decreased by 92.03% and 82.47% in G1 and G2 respectively. G1 and G2 differed significantly (P < 0.05) from G3. Regardless of halogen light activation, the application of the bleaching gel on the cultured odontoblast-like cells caused significantly more severe cytotoxic effects than those observed in the nontreated control group. In addition, significant morphological cell alterations were observed in G1 and G2.After three consecutive applications of a 35% H2O2 bleaching agent, the diffusion of the gel components through enamel and dentine caused severe toxic effects to cultured pulp cells.
Resumo:
OBJETIVO: avaliar a resistência de braquetes metálicos colados em dentes humanos com resina polimerizada com luz halógena por meio de ensaios mecânicos de cisalhamento. METODOLOGIA: para este estudo foram realizados ensaios in vivo com dinamômetro portátil digital e in vitro com máquina de ensaios mecânicos universal com e sem termociclagem, complementado pelo Índice de Adesivo Remanescente (IAR). Braquetes Edgewise Standard (Abzil) foram colados utilizando adesivo Transbond Plus Self Etching Primer (SEP) e Resina Transbond XT. Foram formados 3 grupos com 10 dentes em cada um deles. No GI os braquetes foram colados nos segundos pré-molares dos pacientes. Nos GII e GIII utilizaram-se primeiros pré-molares extraídos por motivos ortodônticos. Os ensaios mecânicos do GI foram realizados 24 horas após a polimerização diretamente na boca dos pacientes com dinamômetro portátil digital. No GII os corpos-de-prova foram armazenados em água destilada e levados à estufa a 37ºC durante 24 horas e, posteriormente, submetidos à termociclagem, com 1000 ciclos a 5 e 55ºC. No GIII os corpos-de-prova foram armazenados em água destilada em temperatura ambiente por 24 horas e posteriormente submetidos aos ensaios mecânicos. RESULTADOS: os valores médios da resistência ao cisalhamento em Megapascal foram de: GI = 4,39; GII = 7,11 e GIII = 7,35. Após a descolagem foram realizadas fotografias das áreas de colagem, tanto dos dentes submetidos a testes in vivo quanto in vitro e ampliadas 5x para facilitar a visualização. As imagens obtidas foram analisadas, classificadas de acordo com o IAR e, por meio de gráficos de dispersão, foi verificada a relação entre a resistência ao cisalhamento e este índice. CONCLUSÃO: a média dos ensaios mecânicos realizados in vivo foi estatisticamente menor em relação aos ensaios in vitro. Não houve diferenças na resistência ao cisalhamento in vitro entre o grupo termociclado e o não-termociclado. Não houve relação entre tensão de ruptura e tipo de falha.
Resumo:
This in vitro study evaluated the marginal gap at the composite tooth/resin interface in class V cavities under the influence of two insertion techniques and a curing system by means of atomic force microscopy (AFM). Forty enamel and dentin cavities were prepared on the buccal surface in bovine teeth with quadratic forms measuring 2 mm X 2 mm and depth of 1.5 mm. The teeth were then divided into four groups: group A, 10 cavities were restored in one increment, light cured by halogen light; group B, 10 cavities filled with bulk filling, light cured by the light emitting diodes (LED); group C, 10 cavities were restored by the incremental technique, light cured by halogen light; group D, 10 cavities were restored by the incremental technique, light cured by the LED. The teeth underwent the polishing procedure and were analyzed by AFM for tooth/restoration interface evaluation. The data were compared between groups using the nonparametric Kruskall-Wallis and Mann-Whitney tests (p < 0.05). The results showed a statistically significant difference between groups A and B and groups A and C. It was concluded that no insertion and polymerization technique was able to completely seal the cavity.
Resumo:
Objective: Our goal was to investigate the surface temperature variations in the cervical region via infrared thermography, as well as the temperature within the pulp chamber via thermocouples, of mandibular incisors when subjected to dental bleaching using two different 35% hydrogen peroxide gels, red (HP) and green (HPM), when activated by halogen light (HL) and LED light.Background Data: Temperatures increases of more than 5.5 degrees C are considered to be potentially threatening to pulp vitality, while those higher than 10 degrees C can result in periodontal injury.Materials and Methods: Tooth samples were randomly divided into four groups (n = 10 each), according to the bleaching agent and catalyst light source used.Results: Mean values and standard deviations of the temperature increases inside the pulp chamber in the HL groups were 4.4 degrees +/- 2.1 degrees C with HP, and 4.5 degrees +/- 1.2 degrees C with HPM; whereas in the groups using LED light, they were 1.4 degrees +/- 0.3 degrees C for HP, and 1.5 degrees +/- 0.2 degrees C for HPM. For the root surfaces, the maximum temperature increases in the groups irradiated with HL were 6.5 degrees +/- 1.5 degrees C for HP, and 7.5 degrees +/- 1.1 degrees C with HPM; whereas in the groups irradiated with LED light, they were 2.8 degrees +/- 0.7 degrees C with HP, and 3 degrees +/- 0.8 degrees C with HPM. There were no statistically significant differences in pulp and surface temperature increases between the groups using different gels, although the mean temperature increases were significantly higher for the groups irradiated with HL when compared with those irradiated with the LED light (p < 0.05 with Tukey's test).Conclusion: LED light may be safe for periodontal and pulp tissue when using this method, but HL should be used with care.