482 resultados para HRGC-FID
Resumo:
A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 ºC for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 µg mL-1. The limit of detection and the limit of quantitation were 1.0 and 3.0 µg mL-1, respectively. The recoveries of FLU derivatives were in the range of 99.25-99.80%. In inter-day and intra-day analysis, the values of relative standard deviation (%) and the relative mean error (%) were found between 0.20-0.80% and -0.20-0.75%, respectively. The developed method was succesfully applied to analyze the FLU content in tablet formulation. The results were statistically compared with those obtained by the official method, and no significant difference was found between the two methods. Therefore, it can be recommended for the quality control assay of FLU in pharmaceutical industry.
Resumo:
In this work a new method (SPME-GC/FID) was developed to analyze the activity of binary liquid mixtures. The purpose is to demonstrate that SPME is capable to be used to determinate activity coefficients at infinite dilution knowing the fiber properties, with a lower cost than the conventional methods encountered in literature such as GLC. The activity coefficients at infinite dilution in furfural for n-hexane, n-heptane and cyclohexane at 298.15 K was determined using SPME and deviations of literature data was about 7%.
Resumo:
A new method using the headspace solid phase microextraction (HS-SPME) technique was used to evaluate the infinite dilute activity coefficient (γ1∞) in an alcohol/water/salt system. The studied systems were ethanol and water with NaCl and NH4Cl at salt concentrations of 5, 10, 15, and 30% m/v and temperatures of 303.15 and 313.15 K. The method was used to investigate the salt effect on vapor/liquid equilibrium in an ethanol/water system, yielding satisfactory results. The study focused on the rich side in ethanol. The data were compared with the literature infinite dilution data determined by other methods such as differential ebulliometry (EBUL), differential static cell equilibrium (STAT), and gas-liquid chromatography with no gas phase correction (GC). In this study, NaCl showed better separation rates than NH4Cl.
Resumo:
A fast gas chromatography with a flame ionisation detector (GC-FID) method for the simultaneous analysis of methyl palmitate (C16:0), stearate (C18:0), oleate (C18:1), linoleate (C18:2) and linolenate (C18:3) in biodiesel samples was proposed. The analysis was conducted in a customised ionic-liquid stationary-phase capillary, SLB-IL 111, with a length of 14 m, an internal diameter of 0.10 mm, a film thickness of 0.08 µm and operated isothermally at 160 °C using hydrogen as the carrier gas at a rate of 50 cm s-1 in run time about 3 min. Once methyl myristate (C14:0) is present lower than 0.5% m/m in real samples it was used as an internal standard. The method was successful applied to monitoring basic and acidic catalysis transesterification reactions of vegetable oils such as soybean, canola, corn, sunflower and those used in frying process.
Resumo:
Os óleos vegetais comestíveis foram introduzidos na dieta humana em substituição as gorduras animais nas últimas décadas sendo amplamente consumidos em todo o mundo. O presente artigo descreve o desenvolvimento de uma metodologia para análise de aldrin, dieldrin, endrin e endosulfan em óleos vegetais por cromatografia gasosa de alta resolução (HRGC) utilizando-se extração em fase sólida (SPE). As médias de recuperação dos pesticidas estiveram entre 70 e 110%[1].
Resumo:
A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.
Resumo:
The styrene levels of polystyrene (PS) glasses from the most consumed brands of disposable glasses intended for water and coffee in Brazil were determined. A GC-FID method was developed and validated, showing good precision and accuracy. The method was successfully used to determine styrene in 11 PS glass brands. The styrene levels ranged from 1.68 to 43.69 mg/100 g glass, depending on the kind of polymer, thickness, and glass brand. It could be used to control the content of styrene in the polymer. The migration of styrene from the glasses into water and 20 % ethanol was not detected.
Resumo:
This paper reports the separation and identification of indole alkaloids, steroids and triterpenoids from the ethanolic extracts of Tabernaemontana hilariana (Apocynaceae). The alkaloidal fractions from the ethanolic extracts obtained (root barks, green fruits, ripe fruits and seeds) were fractionated and analysed by thin-layer chromatography, capillary gas chromatography-flame ionization detection (cGC-FID) as well as by high-resolution gas chromatography-mass spectrometry (HRGC-MS). 3-Hydroxycoronaridine, ibogamine, coronaridine pseudoindoxyl, coronaridine, catharanthine, voacangine hydroxyindolenine, voacangine pseudoindoxyl, tabernanthine, tetraphyllicine, 3-hydroxyvoacangine, voacangine, isovoacangine and 3-oxocoronaridine were identified. The insoluble fraction of ethanolic extracts obtained from the root barks and green fruits were analysed and ten aliphatic constituents were also identified by cGC-FID and HRGC-MS. (C) 1998 Elsevier B.V. B.V. All rights reserved.
Resumo:
Resumen de la comunicación presentada en el XIII Congreso Nacional de Ingeniería Química, Madrid, 18-20 noviembre 2010.
Resumo:
Some issues have title: FID publications.
Resumo:
O biodiesel produzido para ser comercializado no Brasil deve estar de acordo aos padrões de qualidade estabelecidos pela resolução de 4 de fevereiro de 2010 da Agência Nacional do Petróleo, Gás Natural e do Biocombustível (ANP, 04/2010). Neste trabalho, foi estudada a aplicação dos métodos ASTM D 6584 e EN 14105 para o biodiesel de mamona e biodiesel oriundo de rota etílica. Ambos os métodos empregam GC (Cromatografia Gasosa, do inglês Gas Chromatography) com FID (Detecção por Ionização em Chama, do inglês Flame Ionization Detection) e reação de sililação com N-metil-N-(trimetilsilil)trifluoracetamida (MSTFA). Os compostos foram identificados para quantificação pelos tempos de retenção, para os diglicerídeos e triglicerídeos foram utilizadas bandas de tempo de retenção. Os parâmetros de validação considerados foram: curva analítica, linearidade, sensibilidade, robustez, precisão e exatidão. Os métodos ASTM D 6584 e EN 14105 apresentaram sensibilidade semelhante para todos os compostos. Foram escolhidas as condições cromatográficas estabelecidas pelo método ASTM D 6584 por ser mais rápido que o EN14105 e ter sensibilidade semelhante. O método apresentou boa linearidade com todas as curvas analíticas com r maiores que 0,999. A reação de sililação com MSTFA foi otimizada para o biodiesel etílico de mamona em virtude da sua composição química. Um volume de 500 μL de MSTFA foi escolhido para realização dos ensaios de exatidão e precisão. Os valores de exatidão ficaram entre 67 e 145,9% com valores de precisão menores que 11%. Foi avaliada a ocorrência de efeito matriz para biodiesel etílico de mamona, sendo que esse efeito foi considerado baixo para glicerol, monooleína e dioleína e médio para trioleína. Mesmo havendo efeito de matriz o preparo das curvas analíticas em solvente conforme sugerido pelos métodos de referência foi mantido. O método foi robusto frente às variações da composição química da matriz. Na aplicação do método, esse se mostrou adequado para amostras de biodiesel etílico de mamona, de girassol e da mistura de sebo e soja.
Resumo:
La quantificazione del benzene ematico è un tema di grande interesse nell'ambito della tossicologia occupazionale. La determinazione dell'analita, estratto nello spazio di testa di un vial, è eseguita mediante l'utilizzo di un gascromatografo con rilevatore a ionizzazione di fiamma (GC-FID). Si è cercato di ottimizzare il processo di estrazione del benzene dal sangue allo spazio di testa ed il successivo trasferimento dell'analita nella colonna cromatografica, mediante l'applicazione di un disegno sperimentale fattoriale a tre fattori e due livelli (DoE). I fattori individuati per impostare il piano sperimentale sono stati: variazione della temperatura di incubazione (A) del vial contenente il campione di sangue, pH del campione (B), modulato mediante aggiunta di una soluzione di H2SO4 e forza ionica (C), regolata mediante una soluzione acquosa di NaCl. I livelli scelti per ciascuna variabile sono stati: per A 40 e 60 °C; per B pH naturale del campione e pH a seguito dell'aggiunta di 1 mL di H2SO4 1.8 M; per C FI naturale del campione e FI dovuta all'aggiunta di una soluzione acquosa di sodio cloruro (5 g/L). Dall'analisi dei risultati forniti dal DoE, si è osservato che A, B e C hanno effetti tra loro contrastanti, per questo motivo non sembra essere vantaggioso combinare variabili differenti. In compenso, sia l'aumento di temperatura che l'aggiunta di acido solforico portano a significativi miglioramenti nell'estrazione di benzene dal sangue. Tra i tre trattamenti risulta essere B quello più efficace, motivo per il quale si ritiene che l'aggiunta di una soluzione acquosa di H2SO4 al campione di sangue porti ad una maggiore sensibilità e risoluzione strumentale. Sicuramente la sensibilità del metodo elaborato non può essere paragonata alle tradizionali determinazioni con spettrometro di massa, ma si ritiene possa essere sufficientemente soddisfacente per valutare l'esposizione a benzene dei lavoratori a rischio e come analisi di screening rapida ed economica.
Resumo:
Bacterial strains and metagenomic clones, both obtained from petroleum reservoirs, were evaluated for petroleum degradation abilities either individually or in pools using seawater microcosms for 21 days. Gas Chromatography-Flame Ionization Detector (GC-FID) and Gas Chromatography-Mass Spectrometry (GC-MS) analyses were carried out to evaluate crude oil degradation. The results showed that metagenomic clones 1A and 2B were able to biodegrade n-alkanes (C14 to C33) and isoprenoids (phytane and pristane), with rates ranging from 31% to 47%, respectively. The bacteria Dietzia maris CBMAI 705 and Micrococcus sp. CBMAI 636 showed higher rates reaching 99% after 21 days. The metagenomic clone pool biodegraded these compounds at rates ranging from 11% to 45%. Regarding aromatic compound biodegradation, metagenomic clones 2B and 10A were able to biodegrade up to 94% of phenanthrene and methylphenanthrenes (3-MP, 2-MP, 9-MP and 1-MP) with rates ranging from 55% to 70% after 21 days, while the bacteria Dietzia maris CBMAI 705 and Micrococcus sp. CBMAI 636 were able to biodegrade 63% and up to 99% of phenanthrene, respectively, and methylphenanthrenes (3-MP, 2-MP, 9-MP and 1-MP) with rates ranging from 23% to 99% after 21 days. In this work, isolated strains as well as metagenomic clones were capable of degrading several petroleum compounds, revealing an innovative strategy and a great potential for further biotechnological and bioremediation applications.