924 resultados para HPLC-UV-PAD
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Química - IQ
Resumo:
This paper reports on the development and validation of a simple and sensitive method that uses solid phase extraction (SPE) and liquid chromatography with ultraviolet detection to analyze fluoxetine (FLX) and norfluoxetine (NFLX) in human plasma samples. A lab-made C18 SPE phase was synthesized by using a sol–gel process employing a low-cost silica precursor. This sorbent was fully characterized by nuclear magnetic resonance (NMR), Fourier-transform infrared spectroscopy (FT-IR), and scanning electron microscopy (SEM) to check the particles' shape, size and C18 functionalization. The lab-made C18 silica was used in the sample preparation step of human plasma by the SPE-HPLC-UV method. The method was validated in the 15 to 500 ng mL 1 range for both FLX and NFLX using a matrix matched curve. Detection limits of 4.3 and 4.2 ng mL 1 were obtained for FLX and NFLX, respectively. The repeatability and intermediary precision achieved varied from 7.6 to 15.0% and the accuracy ranged from 14.9 to 9.1%. The synthesized C18 sorbent was compared to commercial C18 sorbents. The average recoveries were similar (85–105%), however the lab-made C18 silica showed fewer interfering peaks in the chromatogram. After development and validation, the method using the lab-made C18 SPE was applied to plasma samples of patients under FLX treatment (n ¼ 6). The concentrations of FLX and NFLX found in the samples varied from 46.8–215.5 and 48.0–189.9 ng mL 1 , respectively.
Resumo:
An accurate, sensitive, precise and rapid reversed-phase high-performance liquid chromatographic method was successfully developed and validated for the determination of caffeic acid (CA) in emulsions. The best separation was achieved on a 250 × 4.6 mm, 5.0 µm particle size RP18 XDB Waters column using ethanol and purified water (40:60 v/v) adjusted to pH 2.5 with acetic acid as the mobile phase at a flow rate of 0.7 mL/min. Ultraviolet detection was performed at 325 nm at ambient column temperature (25°C). The method was linear over the concentration range of 10-60 µg/mL (r(2) = 0.9999) with limits of detection and quantification of 1.44 and 4.38 µg/mL, respectively. CA was subjected to oxidation, acid, base and neutral degradation, as well as photolysis and heat as stress conditions. There were no interfering peaks at or near the retention time of CA. The method was applied to the determination of CA in standard and pharmaceutical products with excellent recoveries. The method is applicable in the quality control of CA.
Resumo:
Diclofenac sodium (DS) is a non-steroidal anti-inflammatory drug that is widely prescribed for the treatment of rheumatoid arthritis and post-surgery analgesia. The active pharmaceutical ingredient is the anhydrous form; however, it can also exist in hydrate form. In this context, knowing the properties of the solid state is important and relevant in the pharmaceutical area because they have a significant impact on the solubility, bioavailability, and chemical stability of the drugs. In the present study, data from XRPD, FTIR spectroscopy, and thermal analysis were used for the identification and characterization of DS forms (anhydrous and hydrate). An HPLC method was optimized to evaluate the plasma concentration of DS in rabbits. The optimized method exhibited good linearity over the range 0.1-60 mu g/mL with correlation coefficients of >0.9991. The mean recovery was 100%. Precision and accuracy were determined within acceptable limits. Finally, to compare the pharmacological properties of anhydrous and hydrate DS forms, we investigated their effects in the febrile response induced by lipopolysaccharide from E. coli in rabbits. The results show that the antipyretic effect of anhydrous and hydrate DS forms are similar.
Resumo:
Cefadroxil is a semi-synthetic first-generation oral cephalosporin used in the treatment of mild to moderate infections of the respiratory and urinary tracts, skin and soft tissue infections. In this work a simple, rapid, economic and sensitive HPLC-UV method is described for the quantitative determination of cefadroxil in human plasma samples using lamivudine as internal standard. Sample pre-treatment was accomplished through protein precipitation with acetonitrile and chromatographic separation was performed with a mobile phase consisting of a mixture of sodium dihydrogen phosphate monohydrate solution, methanol and acetonitrile in the ratio of 90:8:2 (v/v/v) at a flow rate of 1.0mL/min. The proposed method is linear between 0.4 to 40.0 mu g/mL and its average recovery is 102.21% for cefadroxil and 97.94% for lamivudine. The method is simple, sensitive, reproducible, less time consuming for determination of cefadroxil in human plasma. The method can therefore be recommended for pharmacokinetics studies, including bioavailability and bioequivalence studies.
Resumo:
The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA (R) SRL assay has the potential to improve this situation. The present communication has compared the CEDIA (R) SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA (R) method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 mu g/L and 20 mu g/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 mu g/L and 20 mu g/L, respectively, The lower limit of quantification was found to be 3.0 mu g/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA (R) method showed a Deming regression line of CEDIA = 1.20 X HPLC-MS/MS - 0.07 (r = 0.934, SEE = 1.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA (R) method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA (R) method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.
Resumo:
O aumento de consumo de cogumelos tem-se verificado em todo o mundo, não só pelo seu valor nutricional, sabor apurado e textura, mas também pelas suas propriedades medicinais. Existem vários estudos científicos que descrevem os benefícios do consumo de cogumelos, que advêm da sua riqueza em compostos bioativos, tais como micosteróis, em particular, ergosterol. Agaricus bisporus L. é o cogumelo mais consumido em todo o mundo, sendo a sua fração de esteróis constituída essencialmente por ergosterol (90%) [1], tornando a sua extração um tópico de elevado interesse já que esta molécula apresenta elevado valor comercial e inúmeras aplicações nas indústrias alimentar, farmacêutica e cosmética. Segundo a literatura, o teor de ergosterol pode variar entre 3 e 9 mg por g de cogumelo seco. Atualmente, os métodos tradicionais tais como a maceração e a extração em Soxhlet estão a ser substituídos por metodologias emergentes, nomeadamente a extração assistida por microondas, visando diminuir a quantidade de solvente utilizado e o tempo de extração e, naturalmente, aumentar o rendimento da mesma. No presente trabalho, utilizou-se A. bisporus como fonte de ergosterol, tendo-se otimizado as seguintes variáveis relevantes para a sua extração pela tecnologia de microondas (MAE): tempo (0-20 min), temperatura (60-210 ºC) e razão sólido-líquido (1-20 g/L). O solvente utilizado foi o etanol tendo-se aplicado a técnica estatística de superfície de resposta por forma a gerar modelos matemáticos que permitissem maximizar a resposta e otimizar as variáveis que afetam a extração de ergosterol. O conteúdo em ergosterol foi monitorizado por HPLC-UV. Os resultados demonstraram que a técnica MAE é promissora para a extração de ergosterol, tendo-se obtido, para as condições ótimas (20,4 min, 121,5ºC e 1,6 g/L), 569,4 mg ergosterol/100 g de massa seca, valor similar ao obtido com extração convencional por Soxhlet (671,5±0,5 mg/100 g de massa seca). Em síntese, a extração assistida por microondas demonstrou ser uma tecnologia eficiente para maximizar o rendimento de extração em ergosterol.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Increased interest in the cholesterol-lowering effect of plant sterols has led to development of plant sterol-enriched foods. When products are enriched, the safety of the added components must be evaluated. In the case of plant sterols, oxidation is the reaction of main concern. In vitro studies have indicated that cholesterol oxides may have harmful effects. Due their structural similarity, plant sterol oxidation products may have similar health implications. This study concentrated on developing high-performance liquid chromatography (HPLC) methods that enable the investigation of formation of both primary and secondary oxidation products and thus can be used for oxidation mechanism studies of plant sterols. The applicability of the methods for following the oxidation reactions of plant sterols was evaluated by using oxidized stigmasterol and sterol mixture as model samples. An HPLC method with ultraviolet and fluorescence detection (HPLC-UV-FL) was developed. It allowed the specific detection of hydroperoxides with FL detection after post-column reagent addition. The formation of primary and secondary oxidation products and amount of unoxidized sterol could be followed by using UV detection. With the HPLC-UV-FL method, separation between oxides was essential and oxides of only one plant sterol could be quantified in one run. Quantification with UV can lead to inaccuracy of the results since the number of double bonds had effect on the UV absorbance. In the case of liquid chromatography-mass spectrometry (LC-MS), separation of oxides with different functionalities was important because some oxides of the same sterol have similar molecular weight and moreover epimers have similar fragmentation behaviour. On the other hand, coelution of different plant sterol oxides with the same functional group was acceptable since they differ in molecular weights. Results revealed that all studied plant sterols and cholesterol seem to have similar fragmentation behaviour, with only relative ion abundances being slightly different. The major advantage of MS detection coupled with LC separation is the capability to analyse totally or partly coeluting analytes if these have different molecular weights. The HPLC-UV-FL and LC-MS methods were demonstrated to be suitable for studying the photo-oxidation and thermo-oxidation reactions of plant sterols. The HPLC-UV-FL method was able to show different formation rates of hydroperoxides during photo-oxidation. The method also confirmed that plant sterols have similar photo-oxidation behaviour to cholesterol. When thermo-oxidation of plant sterols was investigated by HPLC-UV-FL and LC-MS, the results revealed that the formation and decomposition of individual hydroperoxides and secondary oxidation products could be studied. The methods used revealed that all of the plant sterols had similar thermo-oxidation behaviour when compared with each other, and the predominant reactions and oxidation rates were temperature dependent. Overall, these findings showed that with these LC methods the oxidation mechanisms of plant sterols can be examined in detail, including the formation and degradation of individual hydroperoxides and secondary oxidation products, with less sample pretreatment and without derivatization.
Resumo:
手性是自然界的一种普遍现象,生命现象离不开手性。手性物质在有机化学、药物化学、生物化学以及功能材料等领域显示出诱人的应用前景。外消旋体的拆分是手性研究的重要基础工作。高效液相色谱手性固定相法(HPLC-CSP)在对映体化合物的分离分析和制备方面表现出独特的优势。本论文以旋光性联萘类聚合物和纤维素类衍生物涂敷的手性固定相进行分析级和半制备级色谱拆分,研究和探讨了它们对外消旋化合物的手性识别能力。1. 纤维素类聚合物的合成 将微晶纤维素与相应的酰氯或异氰酸酯反应获得四种纤维系类衍生物,纤维素三苯甲酸酯(CTB)、纤维素三苯基氨基甲酸酯(CTPC)、纤维素三(3,5-二甲基苯基氨基甲酸酯)(CDMPC)、纤维素三联萘甲酸酯(CTBPT)。红外、核磁、元素分析证明原料纤维素已酯化完全。2. 旋光性聚合物手性固定相及HPLC手性柱的制备采用聚合物涂敷硅胶方法制备了四种纤维素类、三种联萘聚酰胺手性固定相和二种半制备级纤维素手性固定相,匀浆法装柱。研究了不同的涂敷液对色谱柱效的影响。3. 旋光性联萘聚酰胺手性柱拆分能力的探讨 在三种由(S)-联萘聚酰胺涂敷的色谱柱上,以多种流动相体系对多种外消旋化合物进行手性折分试验。4. 纤维素类手性分析柱拆分能力的研究 对手性柱进行塔板数和稳定性测试及拆分能力研究。对一些外消旋化合物实现了手性拆分。由实验结果可以看出,以CDMPC涂敷的手性柱对多种外消旋化合(包括药物)具有手性拆分能力,具分离度较高。5. 半制备级拆分 对三种外消旋药物在纤维素半制备色谱柱上进行了半制备级拆分。我们在分析型色谱柱进行了流动相条件的选择,将优化后的分析条件直接放大到半制备色谱中,不仅节省了模索条件的时间,而且可以节省大量的流动相,预计一天内所能达到的对外消旋体最大拆分量可达克级以上。6. 进行了HPLC-UV-旋光仪的联用检测研究,实现了在线流动过程中旋光曲线的绘制。
Resumo:
Galactooligosaccharides (GOS) are well-known prebiotic ingredients which can form the basis of new functional dairy products. In this work, the production and characterization of glycated beta-lactoglobulin beta-LG) with prebiotic GOS through the Maillard reaction under controlled conditions (a(w) = 0.44, 40 degrees C for 23 days) have been studied. The extent of glycation of beta-LG was evaluated by formation of furosine which progressively increased with storage for up to 16 days, suggesting that the formation of Amadori compounds prevailed over their degradation. RP-HPLC-UV, SIDS-PAGE, and IEF profiles of beta-LG were modified as a consequence of its glycation. MALDI-ToF mass spectra of glycated beta-LG showed an increase of up to similar to 21% in its average molecular mass after storage for 23 days. Moreover, a decrease in unconjugated GOS (one tri-, two tetra-, and one pentasaccharide) was observed by HPAEC-PAD upon glycation. These results were confirmed by ESI MS. The stability of the glycated beta-LG to in vitro simulated gastrointestinal digestion was also described and compared with that of the unglycated protein. The yield of digestion products of glycated beta-LG was lower than that observed for the unglycated protein. The conjugation of prebiotic carbohydrates to stable proteins and peptides could open new routes of research in the study of functional ingredients.
Resumo:
Comparative HPLC-UV and LC-MS/MS studies of impurity profiles of a reference sample (Xenical (R), F. Hoffmann La Roche Ltd., Switzerland) vs. generic (Lipiblock (R), EMS Sigma Pharma, a generic drug) were carried out with ethanol extracts of commercial samples. The generic formulation contained higher levels of common impurities as well as a considerable number of impurities not found in the reference product. The detected impurity profile of Lipiblock (R) revealed that it most likely is based on fermentation. Since the effect of the impurities is unknown, at this point fully synthetic Xenical (R) appears to offer a better safety margin than Lipiblock (R) which, however, compares quite well to other generic formulations.
Resumo:
A S(+) cetamina é um fármaco amplamente utilizado na medicina para induzir anestesia e a associação com midazolam é empregada para minimizar seus efeitos adversos. Associações medicamentosas podem resultar em interações farmacocinéticas e a disponibilidade de métodos bioanalíticos para a determinação da cetamina em plasma constitui ferramenta útil para a avaliação do perfil cinético do fármaco administrado isoladamente ou em associação. O presente estudo teve como objetivo o desenvolvimento e validação de um método analítico para determinação da cetamina em plasma por cromatografia líquida de alta eficiência (HPLC) e a investigação do perfil farmacocinético da cetamina em quatro cães hígidos da raça Beagle. A S(+) cetamina (10mg/kg) foi administrada pela veia cefálica em dose única isoladamente (protocolo I) ou associada ao midazolam (0.2mg/kg) (protocolo II) em estudo cruzado com intervalo de uma semana para washout. Amostras seriadas de sangue foram coletadas no intervalo de oito horas e analisadas por HPLC para a avaliação do perfil farmacocinético utilizando modelo bicompartimental. O método bioanalítico apresentou limites de confiança aceitáveis para sua aplicação em estudos de farmacocinética e os parâmetros área sob a curva (ASC0-8), volume de distribuição (Vd), clearance total (Clt), meia vida de eliminação (t/12 ß), constante de eliminação (ß), meia vida de distribuição (t1/2α) e constante de distribuição (α) não mostraram diferenças estatísticas significativas entre os grupos (p < 0.05, Wilcoxon). Os resultados obtidos sugerem que a redução dos efeitos colaterais da cetamina decorrente do uso da associação cetamina-midazolam não está relacionada a alterações no perfil farmacocinético da cetamina.