77 resultados para HFC-134a


Relevância:

60.00% 60.00%

Publicador:

Resumo:

CFC-113a (CF3CCl3), CFC-112 (CFCl2CFCl2) and HCFC-133a (CF3CH2Cl) are three newly detected molecules in the atmosphere that are almost certainly emitted as a result of human activity. It is important to characterise the possible contribution of these gases to radiative forcing of climate change and also to provide information on the CO2-equivalence of their emissions. We report new laboratory measurements of absorption cross-sections of these three compounds at a resolution of 0.01 cm−1 for two temperatures 250 K and 295 K in the spectral range of 600–1730 cm−1. These spectra are then used to calculate the radiative efficiencies and global warming potentials (GWP). The radiative efficiencies are found to be between 0.15 and 0.3 W∙m−2∙ppbv−1. The GWP for a 100 year time horizon, relative to carbon dioxide, ranges from 340 for the relatively short-lived HCFC-133a to 3840 for the longer-lived CFC-112. At current (2012) concentrations, these gases make a trivial contribution to total radiative forcing; however, the concentrations of CFC-113a and HCFC-133a are continuing to increase. The 2012 CO2-equivalent emissions, using the GWP (100), are estimated to be about 4% of the current global CO2-equivalent emissions of HFC-134a

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A procedure for calculation of refrigerant mass flow rate is implemented in the distributed numerical model to simulate the flow in finned-tube coil dry-expansion evaporators, usually found in refrigeration and air-conditioning systems. Two-phase refrigerant flow inside the tubes is assumed to be one-dimensional, unsteady, and homogeneous. In themodel the effects of refrigerant pressure drop and the moisture condensation from the air flowing over the external surface of the tubes are considered. The results obtained are the distributions of refrigerant velocity, temperature and void fraction, tube-wall temperature, air temperature, and absolute humidity. The finite volume method is used to discretize the governing equations. Additionally, given the operation conditions and the geometric parameters, the model allows the calculation of the refrigerant mass flow rate. The value of mass flow rate is computed using the process of parameter estimation with the minimization method of Levenberg-Marquardt minimization. In order to validate the developed model, the obtained results using HFC-134a as a refrigerant are compared with available data from the literature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Here we present two-phase flow nonlinear parameter estimation for HFC's flow through capillary tube-suction line heat exchangers, commonly used as expansion devices in small refrigeration systems. The simplifying assumptions adopted are: steady state, pure refrigerant, one-dimensional flow, negligible axial heat conduction in the fluid, capillary tube and suction line walls. Additionally, it is considered that the refrigerant is free from oil and both phases are assumed to be at the same pressure, that is, surface tension effects are neglected. Metastable flow effects are also disregarded, and the vapor is assumed to be saturated at the local pressure. The so-called homogeneous model, involving three, first order, ordinary differential equations is applied to analyze the two-phase flow region. Comparison is done with experimental measurements of the mass flow rate and temperature distribution along capillary tubes working with refrigerant HFC-134a in different operating conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article examines, through a molecular perspective, the 'ozone-friendly' refrigerants R-134a and R-123 vis-à-vis R-12 and R-11, which are targeted to be phased out under the Montreal Protocol on Substances that Deplete the Ozone Layer, Final Act (1987). It appears that the molecular weight, size parameter, and dipole moment, of R-134a and R-123, may induce a pronounced effect on the chemical equilibrium of ice particles in the polar stratospheric clouds and subsequently influence the photochemical reactions therein. Non-polar, high-molecular-weight perfluoropropane (R-218), could be a better substitute for R-12, while R-134, which is a non-polar HFC of the ethane family, could also be a candidate although its molecular weight is lower than that of R-12. The search for a good substitute for R-11, however, must continue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a set of linear equations describing the temperature dependence of the saturated liquid thermal conductivity covering the region of engineering importance for the new hydrofluorocarbons (HFC) 32, 125, 134a, 143a, 152a and hydrochlorofluorocarbons (HCFC) 123, 124, 141b and 142b. Available experimental data in the literature have been considered to arrive at a correlation of the form lambda = A - BT. It is observed that there exists an appreciable discrepancy between various sources of data in spite of the same purity of samples used and the same measurement technique being adopted. The correlations obtained here could be useful in engineering design applications. (C) 1998 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primeiro projeto de Constituição começa a ser discutido pelo Plenário da Assembleia Nacional Constituinte (ANC). Os constituintes poderão apresentar emendas e tudo poderá ser revisto. Bernardo Cabral (PMDB-AM) diz que já foi possível avaliar quais são os anseios da sociedade brasileira e que, com a apresentação das emendas de adequação, já se pode prever o que virá no futuro. Trabalhadores rurais realizam manifestação pela reforma agrária no Congresso Nacional. Produtores rurais também fizeram manifestação na Praça dos Três Poderes, liderados pelo presidente da UDR (União Democrática Ruralista) Ronaldo Caiado. Entrevistas com produtores rurais. Dados sobre a produção agrícola e sobre a distribuição de terras no Brasil. Representante da cidade de Mangueirinhas fala da condição precária em que vivem os trabalhadores rurais. A região do Bico do Papagaio, no sul do Maranhão, caracteriza-se pela luta entre posseiros e lavradores. O Ministro Paulo Brossard, em visita a cidade de Imperatriz do Maranhão, pede o desarmamento no campo, de tal forma que seja restaurado um clima civilizado de convívio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From what was stated in the Montreal Protocol, the researchers and refrigeration industry seek substitutes for synthetic refrigerants -chlorofluorocarbons (CFCs) and HCFCs (HCFC) - that contribute to the depletion of the ozone layer. The phase-out of these substances was started using as one of the replacement alternatives the synthetic fluids based on hydro fluorocarbons (HFCs) that have zero potential depletion of the ozone layer. However, contribute to the process of global warming. HFC refrigerants are greenhouse gases and are part of the group of gases whose emissions must be reduced as the Kyoto Protocol says. The hydrocarbons (HC's), for not contribute to the depletion of the ozone layer, because they have very low global warming potential, and are found abundantly in nature, has been presented as an alternative, and therefore, are being used in new home refrigeration equipment in several countries. In Brazil, due to incipient production of domestic refrigerators using HC's, the transition refrigerants remain on the scene for some years. This dissertation deals with an experimental evaluation of the conduct of a drinking fountain designed to work with HFC (R-134a), operating with a mixture of HC's or isobutane (R-600a) without any modification to the system or the lubricating oil. In the refrigeration laboratory of Federal University of Rio Grande do Norte were installed, in a drinking fountain, temperature and pressure sensors at strategic points in the refrigeration cycle, connected to an acquisition system of computerized data, to enable the mapping and thermodynamics analysis of the device operating with R-134a or with a mixture of HC's or with R-600a. The refrigerator-test operating with the natural fluids (mixture of HC's or R-600a) had a coefficient of performance (COP) lower than the R-134a

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: