964 resultados para Graph distortion
Resumo:
The technique of frequency-resolved optical gating is used to characterize the intensity and the phase of picosecond pulses after propagation through 700 m of fiber at close to the zero-dispersion wavelength. Using the frequency-resolved optical gating technique, we directly measure the severe temporal distortion resulting from the interplay between self-phase modulation and higher-order dispersion in this regime. The measured intensity and phase of the pulses after propagation are found to be in good agreement with the predictions of numerical simulations with the nonlinear Schrodinger equation. (C) 1997 Optical Society of America.
Resumo:
A k-star is the graph K-1,K-k. We prove a general theorem about k-star factorizations of Cayley graphs. This is used to give necessary and sufficient conditions for the existence of k-star factorizations of any power (K-q)(S) of a complete graph with prime power order q, products C-r1 x C-r2 x ... x C-rk of k cycles of arbitrary lengths, and any power (C-r)(S) of a cycle of arbitrary length. (C) 2001 John Wiley & Sons, Inc.
Resumo:
Symptoms of bladder irritability are common after incontinence surgery but their cause is unknown. This study tests the hypothesis that irritative symptoms after colposuspension are due to distortion of the trigone. As part of longitudinal follow-up studies, 175 women were examined 6 months to 12 years after either an open or a laparoscopic Burch colposuspension. The main outcome measures were symptoms of bladder irritability (frequency, nocturia and urge incontinence) and ultrasound findings (bladder neck position at rest and on Valsalva, the presence of a colposuspension ridge, ridge depth and ridge distance, and trigonal angle). Two positive associations between ultrasound parameters and symptoms of bladder irritability were observed: urge incontinence was more likely in the presence of bladder neck funneling, and women with nocturia had a higher trigonal angle. Increased distortion of the trigone was associated with a reduced incidence of urge incontinence in the subgroup of patients after laparoscopic colposuspension. The data presented in this study do not support the hypothesis that symptoms of bladder irritability are due to trigonal distortion or overelevation.
Resumo:
A systematic method for constructing trigonometric R-matrices corresponding to the (multiplicity-free) tensor product of any two affinizable representations of a quantum algebra or superalgebra has been developed by the Brisbane group and its collaborators. This method has been referred to as the Tensor Product Graph Method. Here we describe applications of this method to untwisted and twisted quantum affine superalgebras.
Resumo:
Evoked otoacoustic emissions have demonstrated potential for application in the community-based hearing screening of paediatric populations. Distortion-product otoacoustic emissions (DPOAEs), as opposed to transient evoked otoacoustic emissions (TEOAEs), have not been extensively researched in this regard. The current study aimed to describe the range of DPOAE values obtained in a large cohort (1576 ears) of 6-year-old children in school settings and to examine possible ear asymmetry, gender and history of ear infection effects on the data. Results indicated a variety of significant effects, particularly in the high frequencies, for DPOAE signal-to-noise ratio. The measurement parameter, DPOAE amplitude (DP-amp), was found to display potentially less clinical applicability due to large standard deviation values. Use of descriptive normative data, as derived in the present investigation, may contribute toward future improvements in the hearing screening of 6-year-old schoolchildren
Resumo:
In this paper, we show that K-10n can be factored into alpha C-5-factors and beta 1-factors for all non-negative integers alpha and beta satisfying 2alpha + beta = 10(n) - 1.
Resumo:
When asked to compare two lateralized shapes for horizontal size, neglect patients often indicate the left stimulus to be smaller. Gainotti and Tiacci (1971) hypothesized that this phenomenon might be related to a rightward bias in the patients' gaze. This study aimed to assess the relation between this size underestimation and oculomotor asymmetries. Eye movements were recorded while three neglect patients judged the horizontal extent of two rectangles. Two experimental manipulations were performed to increase the likelihood of symmetrical scanning of the stimulus display. The first manipulation entailed a sequential, rather than simultaneous presentation of the two rectangles. The second required adaptation to rightward displacing prisms, which is known to reduce many manifestations of neglect. All patients consistently underestimated the left rectangle, but the pattern of verbal responses and eye movements suggested different underlying causes. These include a distortion of space perception without ocular asymmetry, a failure to view the full leftward extent of the left stimulus, and a high-level response bias. Sequential presentation of the rectangles and prism adaptation reduced ocular asymmetries without affecting size underestimation. Overall, the results suggest that leftward size underestimation in neglect can arise for a number of different reasons. Incomplete leftward scanning may perhaps be sufficient to induce perceptual size distortion, but it is not a necessary prerequisite.
Resumo:
In cameras with radial distortion, straight lines in space are in general mapped to curves in the image. Although epipolar geometry also gets distorted, there is a set of special epipolar lines that remain straight, namely those that go through the distortion center. By finding these straight epipolar lines in camera pairs we can obtain constraints on the distortion center(s) without any calibration object or plumbline assumptions in the scene. Although this holds for all radial distortion models we conceptually prove this idea using the division distortion model and the radial fundamental matrix which allow for a very simple closed form solution of the distortion center from two views (same distortion) or three views (different distortions). The non-iterative nature of our approach makes it immune to local minima and allows finding the distortion center also for cropped images or those where no good prior exists. Besides this, we give comprehensive relations between different undistortion models and discuss advantages and drawbacks.