852 resultados para Geração Distribuída
Resumo:
This work presents a study on the design of a photovoltaic system connected to the grid.It discussed the main characteristics of the solar cell which is the basic component for the manufacture of solar modulethe main components of the photovoltaic system and the steps of the photovoltaic and electrical design of the system, ranging from the choice of the photovoltaic module to the dimensioning of the components of the electrical installation.In addition to the technical design, this work contains a complete comparative analysis of the current situation of photovoltaic generation distributed in Brazil and Portugal, through incentive programs to energy use as well as current legislation in both countries
Resumo:
This work presents a study on the design of a photovoltaic system connected to the grid.It discussed the main characteristics of the solar cell which is the basic component for the manufacture of solar modulethe main components of the photovoltaic system and the steps of the photovoltaic and electrical design of the system, ranging from the choice of the photovoltaic module to the dimensioning of the components of the electrical installation.In addition to the technical design, this work contains a complete comparative analysis of the current situation of photovoltaic generation distributed in Brazil and Portugal, through incentive programs to energy use as well as current legislation in both countries
Resumo:
Os sistemas elétricos de potência modernos apresentam inúmeros desafios em sua operação. Nos sistemas de distribuição de energia elétrica, devido à grande ramificação, presença de extensos ramais monofásicos, à dinâmica das cargas e demais particularidades inerentes, a localização de faltas representa um dos maiores desafios. Das barreiras encontradas, a influência da impedância de falta é uma das maiores, afetando significativamente a aplicação dos métodos tradicionais na localização, visto que a magnitude das correntes de falta é similar à da corrente de carga. Neste sentido, esta tese objetivou desenvolver um sistema inteligente para localização de faltas de alta impedância, o qual foi embasado na aplicação da técnica de decomposição por componentes ortogonais no pré-processamento das variáveis e inferência fuzzy para interpretar as não-linearidades do Sistemas de Distribuição com presença de Geração Distribuída. Os dados para treinamento do sistema inteligente foram obtidos a partir de simulações computacionais de um alimentador real, considerando uma modelagem não-linear da falta de alta impedância. O sistema fuzzy resultante foi capaz de estimar as distâncias de falta com um erro absoluto médio inferior a 500 m e um erro absoluto máximo da ordem de 1,5 km, em um alimentador com cerca de 18 km de extensão. Tais resultados equivalem a um grau de exatidão, para a maior parte das ocorrências, dentro do intervalo de ±10%.
Resumo:
Esta dissertação tem por propósito analisar os impactos da geração distribuída sobre as correntes de curto-circuito e sobre a proteção das redes de média tensão das concessionárias de distribuição de energia elétrica usando uma abordagem paramétrica. A principal motivação deste trabalho são os recentes incentivos regulatórios que estão fomentando a geração distribuída no Brasil. Contudo, as redes de distribuição convencionais foram projetadas para serem passivas e a introdução da geração poderá causar problemas de ordem técnica que ainda precisam ser resolvidos. Tais problemas foram pesquisados e aqueles relacionados com os impactos sobre as correntes de curto-circuito foram enfatizados. As normas técnicas das concessionárias também foram investigadas porque seus requisitos, como a ligação dos transformadores de acoplamento, influem nas correntes de curto-circuito. Para se calcular as correntes de curto-circuito, desenvolveu-se uma planilha eletrônica cujos resultados foram validados com programas comerciais de análise de redes elétricas. Esta ferramenta foi utilizada para demonstrar, através de exemplos, o impacto causado pela geração distribuída sobre as correntes de curto-circuito e, posteriormente, para realizar as análises paramétricas nas quais a influência de cada variável foi avaliada. A aplicação do método paramétrico permitiu o estudo de possíveis limites para a potência de um gerador distribuído em função dos impactos admissíveis, de seu ponto de conexão, de seus parâmetros elétricos e dos parâmetros elétricos da rede.
Resumo:
O mercado de geração distribuída de energia solar fotovoltaica apresenta-se em estágio inicial de desenvolvimento no Brasil. A recente conjuntura regulatória, entretanto, aponta para a mudança deste cenário: as últimas revisões da regulação aplicável trouxeram aumento na viabilidade econômica de projetos no setor. Isto, somado à presença abundante de recurso solar no Brasil e ao presente estágio de desenvolvimento da tecnologia fotovoltaica indicam um possível crescimento da penetração da fonte no país nos próximos anos. Nesse contexto, o presente estudo tem como objetivo analisar quais recursos e capacidades a empresa Axis Renováveis deve possuir para alcançar uma posição de vantagem competitiva, à luz do RBT. A empresa selecionada para a condução do estudo de caso único é uma start-up atuante no setor. Espera-se que, ao final do trabalho, as conclusões tenham implicação direta na estratégia da empresa e possam servir como ponto de partida para outras empresas do setor.
Resumo:
A typical electrical power system is characterized by centr alization of power gene- ration. However, with the restructuring of the electric sys tem, this topology is changing with the insertion of generators in parallel with the distri bution system (distributed gene- ration) that provides several benefits to be located near to e nergy consumers. Therefore, the integration of distributed generators, especially fro m renewable sources in the Brazi- lian system has been common every year. However, this new sys tem topology may result in new challenges in the field of the power system control, ope ration, and protection. One of the main problems related to the distributed generati on is the islanding formation, witch can result in safety risk to the people and to the power g rid. Among the several islanding protection techniques, passive techniques have low implementation cost and simplicity, requiring only voltage and current measuremen ts to detect system problems. This paper proposes a protection system based on the wavelet transform with overcur- rent and under/overvoltage functions as well as infomation of fault-induced transients in order to provide a fast detection and identification of fault s in the system. The propo- sed protection scheme was evaluated through simulation and experimental studies, with performance similar to the overcurrent and under/overvolt age conventional methods, but with the additional detection of the exact moment of the fault.
Resumo:
The increasing demand in electricity and decrease forecast, increasingly, of fossil fuel reserves, as well as increasing environmental concern in the use of these have generated a concern about the quality of electricity generation, making it well welcome new investments in generation through alternative, clean and renewable sources. Distributed generation is one of the main solutions for the independent and selfsufficient generating systems, such as the sugarcane industry. This sector has grown considerably, contributing expressively in the production of electricity to the distribution networks. Faced with this situation, one of the main objectives of this study is to propose the implementation of an algorithm to detect islanding disturbances in the electrical system, characterized by situations of under- or overvoltage. The algorithm should also commonly quantize the time that the system was operating in these conditions, to check the possible consequences that will be caused in the electric power system. In order to achieve this it used the technique of wavelet multiresolution analysis (AMR) for detecting the generated disorders. The data obtained can be processed so as to be used for a possible predictive maintenance in the protection equipment of electrical network, since they are prone to damage on prolonged operation under abnormal conditions of frequency and voltage.
Resumo:
Power generation from alternative sources is at present the subject of numerous research and development in science and industry. Wind energy stands out in this scenario as one of the most prominent alternative in the generation of electricity, by its numerous advantages. In research works, computer reproduction and experimental behavior of a wind turbine are very suitable tools for the development and study of new technologies and the use of wind potential of a given region. These tools generally are desired to include simulation of mechanical and electrical parameters that directly affect the energy conversion. This work presents the energy conversion process in wind systems for power generation, in order to develop a tool for wind turbine emulation testing experimental, using LabVIEW® software. The purpose of this tool is to emulate the torque developed in an axis wind turbine. The physical setup consists of a three phase induction motor and a permanent magnet synchronous generator, which are evaluated under different wind speed conditions. This tool has the objective to be flexible to other laboratory arrangements, and can be used in other wind power generation structures in real time. A modeling of the wind power system is presented, from the turbine to the electrical generator. A simulation tool is developed using Matlab/Simulink® with the purpose to pre-validate the experiment setup. Finally, the design is implemented in a laboratory setup.
Resumo:
Tese (doutorado)—Universidade de Brasília, Centro de Desenvolvimento Sustentável, 2015.
Resumo:
The generation of electricity in Brazil is predominantly renewable, with internal hydraulic generation being more than 70% of its energy matrix. The electricity rationing occurred in 2001 due to lack of rain, led the country to increase the participation of alternative energy sources. This need for new sources of energy makes the regional potential to be exploited, which configures the change of generation model from centralized generation to distributed generation. Among the alternative sources of energy, the solar energy is presented as very promising for Brazil, given that most of its territory is located near to the equator line, which implies days with greater number of hours of solar radiation. The state of Rio Grande do Norte (RN) has one of the highest levels of solar irradiation of the Brazilian territory, making it eligible to receive investments for the installation of photovoltaic solar plants. This thesis will present the state-of-the-art in solar photovoltaic power generation and will examine the potential for generation of solar photovoltaic power in Brazil and RN, based on solarimetrics measurements conducted by various institutions and also measurements performed in Natal, the state capital
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Due to the high value of the bill that the Brazilian has been paying, one of the most expensive in the world, is becoming increasingly attractive the option for renewable energy in form of distributed micro and minigeneration. In other words, the renewable energy sources are becoming attractive not only because of environmental concerns, but also due to economic issues. This has become even more relevant and concrete after approval of rules by National Agency of Electric Energy (ANEEL) on 4/17/2012 (Normative Resolution n ° 482/2012 of 04/17/2012) aimed at reducing barriers to installation of small distributed generation, including microgeneration, with up to 100 kW of power, and minigeneration, 100 kW to 1 MW. The Normative Resolution n ° 482/2012 creates the Energy Clearing System, which allows consumers to install small generators in its consumer unit and exchange energy with the local distributor. The rule applies to generators that use renewable sources of energy (hydro, solar, biomass, wind and cogeneration qualified). In this context, this paper presents a technical and economic analysis of installing a residential microgenerating plant composed of photovoltaic cells, solar panels and small wind turbines
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.