991 resultados para Generation capacity adequacy
Resumo:
Currently, there are several power converter topologies applied to wind power generation. The converters allow the use of wind turbines operating at variable speed, enabling better use of wind forces. The high performance of the converters is being increasingly demanded, mainly because of the increase in the power generation capacity by wind turbines, which gave rise to various converter topologies, such as parallel or multilevel converters. The use of converters allow effective control of the power injected into the grid, either partially, for the case using partial converter, or total control for the case of using full converter. The back-to-back converter is one of the most used topologies in the market today, due to its simple structure, with few components, contributing to robust and reliable performance. In this work, is presented the implementation of a wind cogeneration system using a permanent magnet synchronous generator (PMSG) associated with a back-to-back power converter is proposed, in order to inject active power in an electric power system. The control strategy of the active power delivered to the grid by cogeneration is based on the philosophy of indirect control
Resumo:
Includes bibliography
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In October 2008, the Brazilian Government announced plans to invest US$212 billion in the construction of nuclear power plants, totaling a joint capacity of 60,000 MW. Apart from this program, officials had already announced the completion of the construction of the nuclear plant Angra III; the construction of large-scale hydroelectric plans in the Amazon and the implantation of natural gas, biomass and coal thermoelectric plants in other regions throughout the country. Each of these projects has its proponents and its opponents, who bring forth concerns and create heated debates in the specialized forums. In this article, some of these concerns are explained, especially under the perspective of the comparative analysis of costs involved. Under such merit figures, the nuclear option, when compared to hydro plants, combined with conventional thermal and biomass-fueled plants, and even wind, to expand Brazilian power-generation capacity, does not appear as a priority. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Electric power grids throughout the world suffer from serious inefficiencies associated with under-utilization due to demand patterns, engineering design and load following approaches in use today. These grids consume much of the world’s energy and represent a large carbon footprint. From material utilization perspectives significant hardware is manufactured and installed for this infrastructure often to be used at less than 20-40% of its operational capacity for most of its lifetime. These inefficiencies lead engineers to require additional grid support and conventional generation capacity additions when renewable technologies (such as solar and wind) and electric vehicles are to be added to the utility demand/supply mix. Using actual data from the PJM [PJM 2009] the work shows that consumer load management, real time price signals, sensors and intelligent demand/supply control offer a compelling path forward to increase the efficient utilization and carbon footprint reduction of the world’s grids. Underutilization factors from many distribution companies indicate that distribution feeders are often operated at only 70-80% of their peak capacity for a few hours per year, and on average are loaded to less than 30-40% of their capability. By creating strong societal connections between consumers and energy providers technology can radically change this situation. Intelligent deployment of smart sensors, smart electric vehicles, consumer-based load management technology very high saturations of intermittent renewable energy supplies can be effectively controlled and dispatched to increase the levels of utilization of existing utility distribution, substation, transmission, and generation equipment. The strengthening of these technology, society and consumer relationships requires rapid dissemination of knowledge (real time prices, costs & benefit sharing, demand response requirements) in order to incentivize behaviors that can increase the effective use of technological equipment that represents one of the largest capital assets modern society has created.
Resumo:
PURPOSE Advancement of the greater trochanter alters the function of the gluteus medius muscle. However, with the exception of clinical studies and biomechanical lever arm studies, no publications that analyze the consequences of advancement of the greater trochanter on the muscle function exist. The aim of the study was to analyze the mechanical changes of gluteus medius after osteotomy of the greater trochanter in a lab setting. METHODS An anatomical study of origin and insertion of the gluteus medius was carried out on four hips. Based on the dissections, a string model was developed dividing the muscle into five sectors. Changes in muscle fiber length were measured for every 10° of flexion, internal and external rotation and abduction with the trochanter in anatomic, proximalized and distalized positions. RESULTS Distalization of the trochanter leads to an imbalance of muscle action, moving the isometric sector of the muscle anteriorly with more muscle sectors being active during flexion and less during extension. Stretching of the muscle increases passive forces but decreases the force generation capacity of the muscle and at the same time increased muscle fiber excursion may require more energy consumption, which may explain earlier fatigue of the abductor musculature after distalization of the trochanter. For abduction, distalization of the muscle attachment leads to a change in contraction pattern from isometric to isotonic. Optimal balancing and excursion of the muscle is when the tip of the greater trochanter is at level with the hip rotation center. CONCLUSIONS In hips with high riding trochanter, the optimal position is at the level of the center of hip rotation. Excessive distalization should be avoided. As the conclusions and considerations are based on a lab setting, transfer to clinical practice may not necessarily apply.
Resumo:
Concentrating Solar Power (CSP) plants typically incorporate one or various auxiliary boilers operating in parallel to the solar field to facilitate start up operations, provide system stability, avoid freezing of heat transfer fluid (HTF) and increase generation capacity. The environmental performance of these plants is highly influenced by the energy input and the type of auxiliary fuel, which in most cases is natural gas (NG). Replacing the NG with biogas or biomethane (BM) in commercial CSP installations is being considered as a means to produce electricity that is fully renewable and free from fossil inputs. Despite their renewable nature, the use of these biofuels also generates environmental impacts that need to be adequately identified and quantified. This paper investigates the environmental performance of a commercial wet-cooled parabolic trough 50 MWe CSP plant in Spain operating according to two strategies: solar-only, with minimum technically viable energy non-solar contribution; and hybrid operation, where 12 % of the electricity derives from auxiliary fuels (as permitted by Spanish legislation). The analysis was based on standard Life Cycle Assessment (LCA) methodology (ISO 14040-14040). The technical viability and the environmental profile of operating the CSP plant with different auxiliary fuels was evaluated, including: NG; biogas from an adjacent plant; and BM withdrawn from the gas network. The effect of using different substrates (biowaste, sewage sludge, grass and a mix of biowaste with animal manure) for the production of the biofuels was also investigated. The results showed that NG is responsible for most of the environmental damage associated with the operation of the plant in hybrid mode. Replacing NG with biogas resulted in a significant improvement of the environmental performance of the installation, primarily due to reduced impact in the following categories: natural land transformation, depletion of fossil resources, and climate change. However, despite the renewable nature of the biofuels, other environmental categories like human toxicity, eutrophication, acidification and marine ecotoxicity scored higher when using biogas and BM.
Resumo:
Energy is a vital resource for social and economic development. In the present scenario, the search for alternative energy sources has become fundamental, especially after the oil crises between 1973 and 1979, the Chernobyl nuclear accident in 1986 and the Kyoto Protocol in 1997. The demand for the development of new alternative energy sources aims to complement existing forms allows to meet the demand for energy consumption with greater security. Brazil, with the guideline of not dirtying the energy matrix by the fossil fuels exploitation and the recent energy crisis caused by the lack of rains, directs energy policies for the development of other renewable energy sources, complementing the hydric. This country is one of the countries that stand out for power generation capacity from the winds in several areas, especially Rio Grande do Norte (RN), which is one of the states with highest installed power and great potential to be explored. In this context arises the purpose of this work to identify the incentive to develop policies of wind energy in Rio Grande do Norte. The study was conducted by a qualitative methodology of data analysis called content analysis, oriented for towards message characteristics, its informational value, the words, arguments and ideas expressed in it, constituting a thematic analysis. To collect the data interviews were conducted with managers of major organizations related to wind energy in Brazil and in the state of Rio Grande do Norte. The identification of incentive policies was achieved in three stages: the first seeking incentives policies in national terms, which are applied to all states, the second with the questionnaire application and the third to research and data collection for the development of the installed power of the RN as compared to other states. At the end, the results demonstrated hat in Rio Grande do Norte state there is no incentive policy for the development of wind power set and consolidated, specific actions in order to optimize the bureaucratic issues related to wind farms, especially on environmental issues. The absence of this policy hinders the development of wind energy RN, considering result in reduced competitiveness and performance in recent energy auctions. Among the perceived obstacles include the lack of hand labor sufficient to achieve the reporting and analysis of environmental licenses, the lack of updating the wind Atlas of the state, a shortfall of tax incentives. Added to these difficulties excel barriers in infrastructure and logistics, with the lack of a suitable port for large loads and the need for reform, maintenance and duplication of roads and highways that are still loss-making. It is suggested as future work the relationship of the technology park of energy and the development of wind power in the state, the influence of the technology park to attract businesses and industries in the wind sector to settle in RN and a comparison of incentive policies to development of wind energy in the Brazilian states observing wind development in the same states under study.
Resumo:
Wind energy installations are increasing in power systems worldwide and wind generation capacity tends to be located some distance from load centers. A conflict may arise at times of high wind generation when it becomes necessary to curtail wind energy in order to maintain conventional generators on-line for the provision of voltage control support at load centers. Using the island of Ireland as a case study and presenting commercially available reactive power support devices as possible solutions to the voltage control problems in urban areas, this paper explores the reduction in total generation costs resulting from the relaxation of the operational constraints requiring conventional generators to be kept on-line near load centers for reactive power support. The paper shows that by 2020 there will be possible savings of 87€m per annum and a reduction in wind curtailment of more than a percentage point if measures are taken to relax these constraints.
Resumo:
L’écart croissant entre les valeurs marchande et économique des exploitations agricoles québécoises complexifie le processus de transfert des fermes à la prochaine génération. La capacité de payer limitée des repreneurs et les besoins de retraite des cédants restreignent la marge de manoeuvre nécessaire afin de déterminer un prix de vente de l’entreprise adéquat. La présente étude vise à analyser les déterminants du prix de vente des fermes et montre que dans notre échantillon, le prix est significativement corrélé avec les besoins de retraite nets des cédants et de façon moins significative, avec la valeur économique des fonds propres de l’entreprise. Les considérations financières semblent éclipser les aspects humains et d’importants compromis sont réalisés des deux côtés de la transaction en vue d’assurer la continuité de l’entreprise. L’influence d’intervenants externes à l’entreprise entre également en ligne de compte dans la fixation du prix, ce qui implique que la décision ne découle pas uniquement d’une négociation entre cédants et repreneurs. De façon générale, les fermes laitières semblent confrontées aux mêmes défis que les autres types de production quant à la fixation de leur prix de vente, ce qui suggère que la problématique soit davantage une question de gestion plutôt qu’une question spécifique au secteur. À moins d’un rétrécissement de l’écart entre la valeur marchande des actifs et leurs capacités à générer des revenus, la fixation du prix de vente de plusieurs fermes du Québec risque d’être encore plus contraignante à l’avenir.
Resumo:
O contínuo crescimento da população mundial aumenta a demanda e a competição por energia, colocando grande esforço sobre as fontes de energia não renováveis existentes. Devido a isso, políticas globais para geração de energias renováveis e menos poluentes estão sendo fortalecidas, além de promoverem o desenvolvimento de novas tecnologias. Várias formas de conversão de energia foram desenvolvidas no decorrer dos anos, com destaque para os conversores de energia das correntes a base de turbinas, que demonstram alta capacidade de conversão energética e já se encontram em funcionamento. O modelo tridimensional TELEMAC3D foi utilizado para a investigação dos processos hidrodinâmicos. Este modelo foi acoplado ao módulo de conversão de energia para as análises nos locais de maior viabilidade e conversão energética na Plataforma Continental do Sul do Brasil. A região de estudo demonstrou possuir duas regiões com alto potencial para a exploração da energias das correntes marinhas, entretanto a região mais viável para a instalação de conversores de corrente é a região norte delimitada entre o Farol da Conceição e o Farol da Solidão, podendo atingir potência média de 10kW=Dia, e alcançando valores integrados de 3:5MW=Ano. Através de uma análise da sazonalidade foram observados, durante a primavera os períodos mais energéticos em ambas as regiões estudadas. As maiores intensidades de conversão de energia foram estimadas com variabilidade temporal de 16 dias, demonstrando alta correlação com eventos associados à passagem de frentes meteorológicas na região. O sítio da região norte, com a presença de barreiras que representam a forma dos conversores, se destaca mantendo boa conversão durante os eventos de ótimo potencial energético. Esta melhora se deve ao efeito de intensificação do campo de correntes associado à presença da estrutura física que otimiza a eficiência do sítio. Não foram observadas diferenças significativas no padrão de variabilidade temporal das simulações estudadas, indicando que a presença das barreiras não induz grandes alterações no padrão temporal da conversão de energia nas escalas temporais analisadas neste trabalho. Os eventos de alta geração de energia foram relacionados a incidência de fortes ventos de quadrante sul e norte, indicando que pelo formato e disposição dos conversores, ventos de sudoeste e norte podem favorecer ótimos eventos de conversão de energia. As simulações dos sítios de conversão demonstraram alta capacidade de geração energética, com quatro eventos de extrema geração de energia. Entretanto, o sítio da região norte demonstrou eficiência superior a 59,39 GWh ao ano, equivalendo a 0.22% do consumo energético do estado do Rio Grande do Sul no ano de 2010.
Resumo:
This paper presents two strategies for the upgrade of set-up generation systems for tandem cold mills. Even though these mills have been modernized mainly due to quality requests, their upgrades may be made intending to replace pre-calculated reference tables. In this case, Bryant and Osborn mill model without adaptive technique is proposed. As a more demanding modernization, Bland and Ford model including adaptation is recommended, although it requires a more complex computational hardware. Advantages and disadvantages of these two systems are compared and discussed and experimental results obtained from an industrial cold mill are shown.