868 resultados para Gas detectors
Resumo:
The emission of different harmful gases during the storage of solid fuels is a common phenomenon. The gases emitted during the heating process of those combustibles are the same as those emitted during combustion, mainly CO and CO2[1]. Nowadays, measurement of these emissions is mandatory. That is why in many industrial facilities different gas detectors are located to measure these gases. But it should be also useful if emissions could be predicted and the temperatures at the beginning of the emission process could be determined.
Resumo:
An ab initio study of the adsorption processes on NOx compounds on (1 1 0) SnO2 surface is presented with the aim of providing theoretical hints for the development of improved NOx gas sensors. From first principles calculations (DFT¿GGA approximation), the most relevant NO and NO2 adsorption processes are analyzed by means of the estimation of their adsorption energies. The resulting values and the developed model are also corroborated with experimental desorption temperatures for NO and NO2, allowing us to explain the temperature-programmed desorption experiments. The interference of the SO2 poisoning agent on the studied processes is discussed and the adsorption site blocking consequences on sensing response are analyzed.
Resumo:
The Beckman Helium Discharge Detector has been found to be sensitive to the fixed gases oxygen, nitrogen, and hydrogen at detection levels 10-100 times more sensitive than possible with a Bow-Mac Thermal Conductivity Detector. Detection levels o~ approximately 1.9 E-4 ~ v/v oxygen, 3.1 E-4 ~ v/v nitrogen, and 3.0 E-3 ~ v/v hydrogen are estimated. Response of the Helium Discharge Detector was not linear, but is useable for quantitation over limited ranges of concentration using suitably prepared working standards. Cleanliness of the detector discharge electrodes and purity of the helium carrier and discharge gas were found to be critical to the operation of the detector. Higher sensitivities of the Helium Discharge Detector may be possible by the design and installation of a sensitive, solid-state electrometer.
Resumo:
The development and study of detectors sensitive to flammable combustible and toxic gases at low cost is a crucial technology challenge to enable marketable versions to the market in general. Solid state sensors are attractive for commercial purposes by the strength and lifetime, because it isn t consumed in the reaction with the gas. In parallel, the use of synthesis techniques more viable for the applicability on an industrial scale are more attractive to produce commercial products. In this context ceramics with spinel structure were obtained by microwave-assisted combustion for application to flammable fuel gas detectors. Additionally, alternatives organic-reducers were employed to study the influence of those in the synthesis process and the differences in performance and properties of the powders obtained. The organic- reducers were characterized by Thermogravimetry (TG) and Derivative Thermogravimetry (DTG). After synthesis, the samples were heat treated and characterized by Fourier Transform Infrared Spectroscopy (FTIR), X-ray Diffraction (XRD), analysis by specific area by BET Method and Scanning Electron Microscopy (SEM). Quantification of phases and structural parameters were carried through Rietveld method. The methodology was effective to obtain Ni-Mn mixed oxides. The fuels influenced in obtaining spinel phase and morphology of the samples, however samples calcined at 950 °C there is just the spinel phase in the material regardless of the organic-reducer. Therefore, differences in performance are expected in technological applications when sample equal in phase but with different morphologies are tested
Resumo:
Il monitoraggio dei rilasci può essere indoor o outdoor; l’attenzione del presente lavoro è rivolta a sistemi di monitoraggio di gas infiammabili e/o tossici in ambienti esterni di stabilimenti onshore. L’efficacia dei sistemi di Gas Detection è profondamente influenzata dalla disposizione dei sensori nelle aree di rischio. Esistono codici e standard che forniscono informazioni molto dettagliate per la progettazione dei sistemi di Fire Detection e linee guida per la scelta, l’installazione ed il posizionamento ottimale dei sensori di incendio. La stessa affermazione non si può fare per i sistemi di Gas Detection, nonostante dall’individuazione tempestiva di un rilascio dipendano anche le successive azioni antincendio. I primi tentativi di sviluppare linee guida per il posizionamento dei sensori di gas sono stati effettuati per le applicazioni off-shore, dove l’elevato livello di congestione e il valore delle apparecchiature utilizzate richiedono un efficiente sistema di monitoraggio dei rilasci. Per quanto riguarda gli impianti on-shore, i criteri di posizionamento dei rilevatori di gas non sono ufficialmente ed univocamente definiti: il layout dei gas detectors viene in genere stabilito seguendo criteri di sicurezza interni alle compagnie affiancati da norme di “buona tecnica” e regole empiriche. Infatti, nonostante sia impossibile garantire l’individuazione di ogni rilascio, vi sono linee guida che propongono strategie di posizionamento dei gas detectors in grado di massimizzare la probabilità di successo del sistema di monitoraggio. Il presente lavoro è finalizzato alla verifica del corretto posizionamento dei gas detectors installati presso l’impianto pilota SF2 dello stabilimento Basell Poliolefine Italia di Ferrara.
Resumo:
The development and study of detectors sensitive to flammable combustible and toxic gases at low cost is a crucial technology challenge to enable marketable versions to the market in general. Solid state sensors are attractive for commercial purposes by the strength and lifetime, because it isn t consumed in the reaction with the gas. In parallel, the use of synthesis techniques more viable for the applicability on an industrial scale are more attractive to produce commercial products. In this context ceramics with spinel structure were obtained by microwave-assisted combustion for application to flammable fuel gas detectors. Additionally, alternatives organic-reducers were employed to study the influence of those in the synthesis process and the differences in performance and properties of the powders obtained. The organic- reducers were characterized by Thermogravimetry (TG) and Derivative Thermogravimetry (DTG). After synthesis, the samples were heat treated and characterized by Fourier Transform Infrared Spectroscopy (FTIR), X-ray Diffraction (XRD), analysis by specific area by BET Method and Scanning Electron Microscopy (SEM). Quantification of phases and structural parameters were carried through Rietveld method. The methodology was effective to obtain Ni-Mn mixed oxides. The fuels influenced in obtaining spinel phase and morphology of the samples, however samples calcined at 950 °C there is just the spinel phase in the material regardless of the organic-reducer. Therefore, differences in performance are expected in technological applications when sample equal in phase but with different morphologies are tested
Resumo:
This work is directed to the study and evaluation of gas diffusion electrodes as detectors in hydrogen sensors. Electrochemical experiments were carried out with rotating disk electrodes with a thin porous coating of the catalyst as a previous step to select useful parameters for the sensor. An experimental arrangement made in the laboratory that simulates the sensor was found appropriate to detect volumetric hydrogen percentages above 0.25% in mixtures H2:N2. The system shows a linear response for volumetric percentages of hydrogen between 0.25 and 2 %.
Resumo:
The European Organization for Nuclear Research (CERN) operates the largest particle collider in the world. This particle collider is called the Large Hadron Collider (LHC) and it will undergo a maintenance break sometime in 2017 or 2018. During the break, the particle detectors, which operate around the particle collider, will be serviced and upgraded. Following the improvement in performance of the particle collider, the requirements for the detector electronics will be more demanding. In particular, the high amount of radiation during the operation of the particle collider sets requirements for the electronics that are uncommon in commercial electronics. Electronics that are built to function in the challenging environment of the collider have been designed at CERN. In order to meet the future challenges of data transmission, a GigaBit Transceiver data transmission module and an E-Link data bus have been developed. The next generation of readout electronics is designed to benefit from these technologies. However, the current readout electronics chips are not compatible with these technologies. As a result, in addition to new Gas Electron Multiplier (GEM) detectors and other technology, a new compatible chip is developed to function within the GEMs for the Compact Muon Solenoid (CMS) project. In this thesis, the objective was to study a data transmission interface that will be located on the readout chip between the E-Link bus and the control logic of the chip. The function of the module is to handle data transmission between the chip and the E-Link. In the study, a model of the interface was implemented with the Verilog hardware description language. This process was simulated by using chip design software by Cadence. State machines and operating principles with alternative possibilities for implementation are introduced in the E-Link interface design procedure. The functionality of the designed logic is demonstrated in simulation results, in which the implemented model is proven to be suitable for its task. Finally, suggestions that should be considered for improving the design have been presented.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.
Resumo:
The Large Hadron Collider (LHC) in The European Organization for Nuclear Research (CERN) will have a Long Shutdown sometime during 2017 or 2018. During this time there will be maintenance and a possibility to install new detectors. After the shutdown the LHC will have a higher luminosity. A promising new type of detector for this high luminosity phase is a Triple-GEM detector. During the shutdown these detectors will be installed at the Compact Muon Solenoid (CMS) experiment. The Triple-GEM detectors are now being developed at CERN and alongside also a readout ASIC chip for the detector. In this thesis a simulation model was developed for the ASICs analog front end. The model will help to carry out more extensive simulations and also simulate the whole chip before the whole design is finished. The proper functioning of the model was tested with simulations, which are also presented in the thesis.
Resumo:
A rapid and simple gas chromatographic method for determinating cyprodinil, fludioxonil, pyrimethanil, and tebuconazole in grapes, must, and wine is described. An on-line microextraction method was used with a one-step extraction-partition procedure. Nitrogen-phosphorus and mass spectrometric detectors were used, because of their low sensitivity and high selectivity. Because of high selectivity of detector, no cleanup was necessary and the extract was concentrated 5 times. Recoveries from fortified grapes, must, and wine ranged from 93 to 110%. Limits of determination were 0.05 mg/kg for cyprodinil and pyrimethanil and 0.10 mg/kg for fludioxonil and tebuconazole.
Resumo:
In this paper is reported the use of the chromatographic profiles of volatiles to determine disease markers in plants - in this case, leaves of Eucalyptus globulus contaminated by the necrotroph fungus Teratosphaeria nubilosa. The volatile fraction was isolated by headspace solid phase microextraction (HS-SPME) and analyzed by comprehensive two-dimensional gas chromatography-fast quadrupole mass spectrometry (GC. ×. GC-qMS). For the correlation between the metabolic profile described by the chromatograms and the presence of the infection, unfolded-partial least squares discriminant analysis (U-PLS-DA) with orthogonal signal correction (OSC) were employed. The proposed method was checked to be independent of factors such as the age of the harvested plants. The manipulation of the mathematical model obtained also resulted in graphic representations similar to real chromatograms, which allowed the tentative identification of more than 40 compounds potentially useful as disease biomarkers for this plant/pathogen pair. The proposed methodology can be considered as highly reliable, since the diagnosis is based on the whole chromatographic profile rather than in the detection of a single analyte. © 2013 Elsevier B.V..
Resumo:
Comprehensive two-dimensional gas chromatography (GC x GC) is a powerful technique that provides excellent separation and identification of analytes in highly complex samples with considerable increase in GC peak capacities. However, since second dimension analyses are very fast, detectors with a rapid acquisition rate are required. Over the last years, quite a number of studies have discussed the potential and limitations of the combination GC x GC with a variety of quadrupole mass spectrometers. The present research focuses on the evaluation of qMS effectiveness at a 10,000-amu/s scan speed and 20-Hz scan frequency for the identification (full scan mode acquisition-TIC) and quantification (extracted ion chromatogram) of target pesticide residues in tomato samples. The following MS parameters have been evaluated: number of data points per peak, mass spectrum quality, peak skewing, and sensitivity. The validated proposed GC x GC/qMS method presented satisfactory results in terms of repeatability (coefficient of variation lower than 15%), accuracy (84-117%), and linearity (ranging from 25 to 500 ng/g), while significant enhancement in sensitivity was observed (a factor of around 10) under scan conditions. (C) 2012 Elsevier B.V. All rights reserved.