973 resultados para Forced-choice method


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To investigate whether standard X-ray acquisition factors for orbital radiographs are suitable for the detection of ferromagnetic intra-ocular foreign bodies in patients undergoing MRI. Method: 35 observers, at varied levels of education in radiography, attending a European Dose Optimisation EURASMUS Summer School were asked to score 24 images of varying acquisition factors against a clinical standard (reference image) using two alternative forced choice. The observers were provided with 12 questions and a 5 point Likert scale. Statistical tests were used to validate the scale, and scale reliability was also measured. The images which scored equal to, or better than, the reference image (36) were ranked alongside their corresponding effective dose (E), the image with the lowest dose equal to or better than the reference is considered the new optimum acquisition factors. Results: Four images emerged as equal to, or better than, the reference in terms of image quality. The images were then ranked in order of E. Only one image that scored the same as the reference had a lower dose. The reference image had a mean E of 3.31μSv, the image that scored the same had an E of 1.8μSv. Conclusion: Against the current clinical standard exposure factors of 70kVp, 20mAs and the use of an anti- scatter grid, one image proved to have a lower E whilst maintaining the same level of image quality and lesion visibility. It is suggested that the new exposure factors should be 60kVp, 20mAs and still include the use of an anti-scatter grid.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. METHODS: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. RESULTS: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25-30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. CONCLUSIONS: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An assumption commonly made in the study of visual perception is that the lower the contrast threshold for a given stimulus, the more sensitive and selective will be the mechanism that processes it. On the basis of this consideration, we investigated contrast thresholds for two classes of stimuli: sine-wave gratings and radial frequency stimuli (i.e., j0 targets or stimuli modulated by spherical Bessel functions). Employing a suprathreshold summation method, we measured the selectivity of spatial and radial frequency filters using either sine-wave gratings or j0 target contrast profiles at either 1 or 4 cycles per degree of visual angle (cpd), as the test frequencies. Thus, in a forced-choice trial, observers chose between a background spatial (or radial) frequency alone and the given background stimulus plus the test frequency (1 or 4 cpd sine-wave grating or radial frequency). Contrary to our expectations, the results showed elevated thresholds (i.e., inhibition) for sine-wave gratings and decreased thresholds (i.e., summation) for radial frequencies when background and test frequencies were identical. This was true for both 1- and 4-cpd test frequencies. This finding suggests that sine-wave gratings and radial frequency stimuli are processed by different quasi-linear systems, one working at low luminance and contrast level (sine-wave gratings) and the other at high luminance and contrast levels (radial frequency stimuli). We think that this interpretation is consistent with distinct foveal only and foveal-parafoveal mechanisms involving striate and/or other higher visual areas (i.e., V2 and V4).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of the present study was to precool cauliflower using forced-air, vacuum and high and low flow hydro cooling methods. The weight of the precooled cauliflower heads (5000±5 g) was measured before they were placed in standard plastic crates. Cauliflower heads, whose initial temperature was 23.5 ± 0.5 ºC, were cooled until the temperature reached at 1 ºC. During the precooling process, time-dependent temperature and energy consumption were measured, and during vacuum precooling, the decreasing pressure values were recorded, and a curve of time-dependent pressure decrease (vacuum) was built. The most suitable cooling method to precool cauliflower in terms of cooling time and energy consumption was vacuum, followed by the high and low flow hydro and forced-air precooling methods, respectively. The highest weight loss was observed in the vacuum precooling method, followed by the forced-air method. However, there was an increase in the weight of the cauliflower heads in the high and low flow hydro precooling method. The best colour and hardness values were found in the vacuum precooling method. Among all methods tested, the most suitable method to precool cauliflower in terms of cooling and quality parameters was the vacuum precooling method.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective. Physical activity is important for the health of all human beings. Although it is important to develop good health promotion programs for children to increase participation in physical activity, to date there appear to be no programs based on what kids value beyond health and physical activity itself. This study proposed to create a scale with strong content and face validity that could uncover what any given population of children value in life regardless of their participation in physical activity and that experts feel could be related to physical activity. These findings will allow the development of targeted health promotion programs to increase children's participation in regular physical activity. Method In this study, a combination of qualitative and quantitative approaches was used. Data were gathered from seven experts in the field, sixty-seven children in grades three to five, five parents, and three teachers. From these data response groupings were created and sent to four experts to be given single word names. The resulting nine theme names were re-worked into "child-friendly" language. Four children were then asked to discuss theme names to see if they liked and understood them. The next step involved asking children and experts to rank order the nine themes, the children in general and the experts in terms of relevance to physical activity. From these results, possible versions of the scale were then created using the combined expert/children rankings. Each version was examined for content validity. Two versions of a scale resulted. These were sent to experts, parents, teachers and children in order to determine which one they liked better and to suggest any foreseeable problems. Once this information was collected, a beta (final prototype) version of the scale was created. Results. Nine common theme names were created from the response groupings. All four children agreed that they did understand and like each of the nine theme names. Experts and teachers agreed that full coverage of the content had been achieved. Children suggested a single wording change from "Being Accepted" to "Being Included". Five themes were selected for inclusion. The beta version of the scale included 12 forced choice statements, the first ten comparing all themes against one another followed by two anchor statements. Conclusion. At the outset it was recognized that it is essential to know what children think is important in their lives in order to serve as potential benefits in the development of effective physical activity promotion programs. This study developed a scale which could be used to determine what a population of children feel is important in order to focus health promotion programs for physical activity. The scale has strong face and content validity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to compare the contrast visual processing of concentric sinusoidal gratings stimuli between adolescents and adults. The study included 20 volunteers divided into two groups: 10 adolescents aged 13-19 years (M=16.5, SD=1.65) and 10 adults aged 20-26 years (M=21.8, SD=2.04). In order to measure the contrast sensitivity at spatial frequencies of 0.6, 2.5, 5 and 20 degrees of visual angle (cpd), it was used the psychophysical method of two alternative forced choice (2AFC). A One Way ANOVA performance showed a significant difference in the comparison between groups: F [(4, 237)=3.74, p<.05]. The post-hoc Tukey HSD showed a significant difference between the frequencies of 0.6 (p <.05) and 20 cpd (p<.05). Thus, the results showed that the visual perception behaves differently with regard to the sensory mechanisms that render the contrast towards adolescents and adults. These results are useful to better characterize and comprehend human vision development.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Recent studies have documented that self-determined choice does indeed enhance performance. However, the precise neural mechanisms underlying this effect are not well understood. We examined the neural correlates of the facilitative effects of self-determined choice using functional magnetic resonance imaging (fMRI). Participants played a game-like task involving a stopwatch with either a stopwatch they selected (self-determined-choice condition) or one they were assigned without choice (forced-choice condition). Our results showed that self-determined choice enhanced performance on the stopwatch task, despite the fact that the choices were clearly irrelevant to task difficulty. Neuroimaging results showed that failure feedback, compared with success feedback, elicited a drop in the vmPFC activation in the forced-choice condition, but not in the self-determined-choice condition, indicating that negative reward value associated with the failure feedback vanished in the self-determined-choice condition. Moreover, the vmPFC resilience to failure in the self-determined-choice condition was significantly correlated with the increased performance. Striatal responses to failure and success feedback were not modulated by the choice condition, indicating the dissociation between the vmPFC and striatal activation pattern. These findings suggest that the vmPFC plays a unique and critical role in the facilitative effects of self-determined choice on performance.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O objetivo deste estudo foi estimar a entropia conjunta do sistema visual humano no domínio do espaço e no domínio das freqüências espaciais através de funções psicométricas. Estas foram obtidas com testes de discriminação de estímulos com luminância ou cromaticidade moduladas por funções de Gábor. A essência do método consistiu em avaliar a entropia no domínio do espaço, testando-se a capacidade do sujeito em discriminar estímulos que diferiam apenas em extensão espacial, e avaliar a entropia no domínio das freqüências espaciais, testando-se a capacidade do sujeito em discriminar estímulos que diferiam apenas em freqüência espacial. A entropia conjunta foi calculada, então, a partir desses dois valores individuais de entropia. Três condições visuais foram estudadas: acromática, cromática sem correção fina para eqüiluminância e cromática com correção para eqüiluminância através de fotometria com flicker heterocromático. Quatro sujeitos foram testados nas três condições, dois sujeitos adicionais foram testados na condição cromática sem eqüiluminância fina e um sétimo sujeito também fez o teste acromático. Todos os sujeitos foram examinados por oftalmologista e considerados normais do ponto de vista oftálmico, não apresentando relato, sintomas ou sinais de disfunções visuais ou de moléstias potencialmente capazes de afetar o sistema visual. Eles tinham acuidade visual normal ou corrigida de no mínimo 20/30. O trabalho foi aprovado pela Comissão de Ética em Pesquisa do Núcleo de Medicina Tropical da UFPA e obedeceu às recomendações da Declaração de Helsinki. As funções de Gábor usadas para modulação de luminância ou cromaticidade compreenderam redes senoidais unidimensionais horizontais, moduladas na direção vertical, dentro de envelopes gaussianos bidimensionais cuja extensão espacial era medida pelo desvio padrão da gaussiana. Os estímulos foram gerados usando-se uma rotina escrita em Pascal num ambiente Delphi 7 Enterprise. Foi utilizado um microcomputador Dell Precision 390 Workstation e um gerador de estímulos CRS VSG ViSaGe para exibir os estímulos num CRT de 20”, 800 x 600 pixels, 120 Hz, padrão RGB, Mitsubishi Diamond Pro 2070SB. Nos experimentos acromáticos, os estímulos foram gerados pela modulação de luminância de uma cor branca correspondente à cromaticidade CIE1931 (x = 0,270; y = 0,280) ou CIE1976 (u’ = 0,186; v’= 0,433) e tinha luminância média de 44,5 cd/m2. Nos experimentos cromáticos, a luminância média foi mantida em 15 cd/m2 e foram usadas duas series de estímulos verde-vermelhos. Os estímulos de uma série foram formados por duas cromaticidades definidas no eixo M-L do Espaço de Cores DKL (CIE1976: verde, u’=0,131, v’=0,380; vermelho, u’=0,216, v’=0,371). Os estímulos da outra série foram formados por duas cromaticidades definidas ao longo de um eixo horizontal verde-vermelho definido no Espaço de Cores CIE1976 (verde, u’=0,150, v’=0,480; vermelho, u’=0,255, v’=0,480). Os estímulos de referência eram compostos por redes de três freqüências espaciais diferentes (0,4, 2 e 10 ciclos por grau) e envelope gaussiano com desvio padrão de 1 grau. Os estímulos de testes eram compostos por uma entre 19 freqüências espaciais diferentes em torno da freqüência espacial de referência e um entre 21 envelopes gaussianos diferentes com desvio padrão em torno de 1 grau. Na condição acromática, foram estudados quatro níveis de contraste de Michelson: 2%, 5%, 10% e 100%. Nas duas condições cromáticas foi usado o nível mais alto de contraste agregado de cones permitidos pelo gamut do monitor, 17%. O experimento consistiu numa escolha forçada de dois intervalos, cujo procedimento de testagem compreendeu a seguinte seqüência: i) apresentação de um estímulo de referência por 1 s; ii) substituição do estímulo de referência por um fundo eqüiluminante de mesma cromaticidade por 1 s; iii) apresentação do estímulo de teste também por 1 s, diferindo em relação ao estímulo de referência seja em freqüência espacial, seja em extensão espacial, com um estímulo sonoro sinalizando ao sujeito que era necessário responder se o estímulo de teste era igual ou diferente do estímulo de referência; iv) substituição do estímulo de teste pelo fundo. A extensão espacial ou a freqüência espacial do estímulo de teste foi mudada aleatoriamente de tentativa para tentativa usando o método dos estímulos constantes. Numa série de 300 tentativas, a freqüencia espacial foi variada, noutra série também de 300 tentativas, a extensão espacial foi variada, sendo que cada estímulo de teste em cada série foi apresentado pelo menos 10 vezes. A resposta do indivíduo em cada tentativa era guardada como correta ou errada para posterior construção das curvas psicométricas. Os pontos experimentais das funções psicométricas para espaço e freqüência espacial em cada nível de contraste, correspondentes aos percentuais de acertos, foram ajustados com funções gaussianas usando-se o método dos mínimos quadrados. Para cada nível de contraste, as entropias para espaço e freqüência espacial foram estimadas pelos desvios padrões dessas funções gaussianas e a entropia conjunta foi obtida multiplicando-se a raiz quadrada da entropia para espaço pela entropia para freqüência espacial. Os valores de entropia conjunta foram comparados com o mínimo teórico para sistemas lineares, 1/4π ou 0,0796. Para freqüências espaciais baixas e intermediárias, a entropia conjunta atingiu níveis abaixo do mínimo teórico em contrastes altos, sugerindo interações não lineares entre dois ou mais mecanismos visuais. Este fenômeno occorreu em todas as condições (acromática, cromática e cromática eqüiluminante) e foi mais acentuado para a frequência espacial de 0,4 ciclos / grau. Uma possível explicação para este fenômeno é a interação não linear entre as vias visuais retino-genículo-estriadas, tais como as vias K, M e P, na área visual primária ou em níveis mais altos de processamento neural.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Early malnutrition refers to inadequate nutrition during the critical period of nervous system development followed by nutritional recovery, resulting in a short stature according to age but normal weight according to short stature. We measured the effects of early malnutrition on contrast sensitivity (CS) to concentric circular gratings in 18 children of both sexes, aged 8 to 11 years (mean = 9.2 years, standard deviation = .99 years). Nine of the children were eutrophic (E group), and nine experienced early malnutrition (EM group) based on state healthcare records and Waterlow's anthropometric parameters. Contrast sensitivity to four spatial frequencies (.25, 1.0, 2.0, and 8.0 cycles per degree [cpd]) was measured using a temporal two-alternative forced-choice psychophysical method with mean luminance of 40.1 cd/m². Statistical analyses showed significant differences between groups and a group × frequency interaction. EM group was significantly less sensitive than the E group to the 8.0 cpd frequency and needed 1.49-times more contrast to detect the gratings. These results suggest that early malnutrition impairs CS to high-spatial-frequency concentric circular gratings in children. Therefore, early malnutrition, which is known to affect primary visual cortical areas, may also affect higher visual cortical areas such as V4 and the inferotemporal cortex.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction. Erroneous answers in studies on the misinformation effect (ME) can be reduced in different ways. In some studies, ME was reduced by SM questions, warnings, or a low credibility of the source of post-event information (PEI). Results are inconsistent, however. Of course, a participant can deliberately decide to refrain from reporting a critical item only when the difference between the original event and the PEI is distinguishable in principle. We were interested in the question to what extent the influence of erroneous information on a central aspect of the original event can be reduced by different means applied singly or in combination. Method. With a 2 (credibility; high vs. low) x 2 (warning; present vs. absent) between subjects design and an additional control group that received neither misinformation nor a warning (N = 116), we examined the above-mentioned factors’ influence on the ME. Participants viewed a short video of a robbery. The critical item suggested in the PEI was that the victim was given a kick by the perpetrator (which he was actually not). The memory test consisted of a two-forced-choice recognition test followed by a SM test. Results. To our surprise, neither a main effect of erroneous PEI nor a main effect of credibility was found. The error rates for the critical item in the control group (50%) as well as in the high (65%) and low (52%) credibility condition without warning did not significantly differ. A warning about possible misleading information in the PEI significantly reduced the influence of misinformation in both credibility conditions by 32-37%. Using a SM question significantly reduced the error rate too, but only in the high credibility no warning condition. Conclusion and Future Research. Our results show that, contrary to a warning or the use of a SM question, low source credibility did not reduce the ME. The most striking finding was, however, the absence of a main effect of erroneous PEI. Due to the high error rate in the control group, we suspect that the wrong answers might have been caused either by the response format (recognition test) or by autosuggestion possibly promoted by the high schema-consistency of the critical item. First results of a post-study in which we used open-ended questions before the recognition test support the former assumption. Results of a replication of this study using open-ended questions prior to the recognition test will be available by June.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The transmission of weak signals through the visual system is limited by internal noise. Its level can be estimated by adding external noise, which increases the variance within the detecting mechanism, causing masking. But experiments with white noise fail to meet three predictions: (a) noise has too small an influence on the slope of the psychometric function, (b) masking occurs even when the noise sample is identical in each two-alternative forced-choice (2AFC) interval, and (c) double-pass consistency is too low. We show that much of the energy of 2D white noise masks extends well beyond the pass-band of plausible detecting mechanisms and that this suppresses signal activity. These problems are avoided by restricting the external noise energy to the target mechanisms by introducing a pedestal with a mean contrast of 0% and independent contrast jitter in each 2AFC interval (termed zero-dimensional [0D] noise). We compared the jitter condition to masking from 2D white noise in double-pass masking and (novel) contrast matching experiments. Zero-dimensional noise produced the strongest masking, greatest double-pass consistency, and no suppression of perceived contrast, consistent with a noisy ideal observer. Deviations from this behavior for 2D white noise were explained by cross-channel suppression with no need to appeal to induced internal noise or uncertainty. We conclude that (a) results from previous experiments using white pixel noise should be re-evaluated and (b) 0D noise provides a cleaner method for investigating internal variability than pixel noise. Ironically then, the best external noise stimulus does not look noisy.