29 resultados para Flexing


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wild bearded capuchins (Cebus libidinosus, quadrupedal, medium-sized monkeys) crack nuts using large stones. We examined the kinematics and energetics of the nut-cracking action of two adult males and two adult females. From a bipedal stance, the monkeys raised a heavy hammer stone (1.46 and 1.32 kg, from 33 to 77% of their body weight) to an average height of 0.33 m, 60% of body length. Then, they rapidly lowered the stone by flexing the lower extremities and the trunk until the stone contacted the nut. A hit consisting of an upward phase and a downward phase averaged 0.74 s in duration. The upward phase lasted 69% of hit duration. All subjects added discernable energy to the stone in the downward phase. The monkeys exhibited individualized kinematic strategies, similar to those of human weight lifters. Capuchins illustrate that human-like bipedal stance and large body size are unnecessary to break tough objects from a bipedal position. The phenomenon of bipedal nut-cracking by capuchins provides a new comparative reference point for discussions of percussive tool use and bipedality in primates. Am J Phys Anthropol 138:210-220, 2009. (C) 2008 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The spinal column performs important functions in the body, including the support of the entire weight of the human body, the ability to orientate the head in space, bending, flexing and rotating the body. Diseases affecting the spine are manifold: the most frequent is scoliosis, which often affects the female population. It is often treated surgically with a very high percentage of failures. The aim of the thesis is to study the role of instrumentation in mechanical failures encountered 12 months after surgery in the treatment of scoliosis. For the purposes of the study, we analyzed specific biomechanical parameters. The pelvic angles determine the position of the pelvis, while the imbalance parameters the structure of the body. We infer other parameters by analyzing the characteristics of the implanted instrumentation. Initially, the anatomy is described of the spine and vertebrae, the equipment used and the possible failures that may occur after surgery. Subsequently, the materials and methods used for the analysis of the above-mentioned parameters for the 61 patients are reported. All data are obtained by the observation of pre and post-operative x-rays with a special program, by reading reports from operators and by medical records. In the fourth chapter, we report the results: the overall failure rate is 60.9%; the types of failures that occurred are rupture of bars and rupture of bars simultaneously to PJK. The most influential parameters on results of the progress of the surgery are the type of material used and the BMI. It is estimated a high percentage of failures in patients treated with implants of cobalt chromium alloys (90.0%). According to the results obtained, it is possible to understand the aspects that in the future should be studied, in order to find a solution to the most frequent surgical failures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For nonsurgical treatment of fractures of the proximal phalanges of the triphalangeal fingers, different dynamic casts have been described. The main principle behind these casts is advancement and tightening of the extensor hood, caused by a combination of blocking the metacarpophalangeal joints in flexion and actively flexing the proximal interphalangeal joints. In contrast to established treatment protocols using functional forearm casts, the Lucerne cast allows for free mobilization of the wrist joint. The purpose of the current multicenter study was to compare the results of conservative, functional treatment using 2 different methods, either a forearm cast or a Lucerne cast.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 57-year-old man with genetically proven facioscapulohumeral muscular dystrophy (FSHMD 1A) demonstrated Beevor sign (video on the Neurology Web site at www.neurology.org). The upward movement of the umbilicus in a supine patient flexing the neck or sitting up is named after the British neurologist Charles Edward Beevor (1854-1908). He described a "marked elevation of the umbilicus in the act of sitting up" due to a paralyzed infraumbilical part of the rectus abdominis muscle, indicating a lesion of the spinal cord between the segments T10 and T12 or its nerve roots.(1) Beevor sign may also be present, as in our patient, in myopathies affecting the abdominal muscles, particularly in FSHMD, in which predominant involvement of the lower part of the rectus abdominis muscle is typical.(2).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Air Mines The sky over the city's port was the color of a faulty screen, only partly lit up. As the silhouette of nearby buildings became darker, but more clearly visible against the fading blur-filter of a background, the realization came about how persistent a change had been taking place. Slowly, old wooden water reservoirs and rattling HVAC systems stopped being the only inhabitants of roofs. Slightly trembling, milkish jellyfish-translucent air volumes had joined the show in multiples. A few years ago artists and architects seized upon the death of buildings as their life-saving media. Equipped with constructive atlases and instruments they started disemboweling their subjects, poking about their systems, dumping out on the street the battered ugliness of their embarrassing bits and pieces, so rightly hidden by facades and height from everyday view. But, would you believe it? Even ?old ladies?, investment bankers or small children failed to get upset. Of course, old ladies are not what they used to be. It was old ladies themselves that made it happen after years of fights with the town hall, imaginative proposals and factual arguments. An industry with little financial gains but lots of welcome externalities was not, in fact, the ground for investment bankers. But they too had to admit that having otherwise stately buildings make fine particulate pencils with their facades was not the worse that could happen. Yes, making soot pencils had been found an interesting and visible end product of the endeavor, a sort of mining the air for vintage writing tools one can actually touch. The new view from the street did not seem as solid or dignified as that of old, and they hated that the market for Fine Particulates Extraction (FPE, read efpee) had to be applied on a matrix of blocks and streets that prevented undue concentration of the best or worse solutions. It had to be an evenly distributed city policy in order for the city to apply for cleaning casino money. Once the first prototypes had been deployed in buildings siding Garden Avenue or Bulwark Street even fast movers appreciated the sidekick of flower and plant smell dripping down the Urban Space Stations (USS, read use; USSs, read uses) as air and walls cooled off for a few hours after sunset. Enough. It was all nice to remember, but it was now time to go up and start the lightweight afternoon maintenance of their USS. Coop discussions had taken place all through the planning and continued through the construction phase as to how maintenance was going to be organized. Fasters had voted for a pro, pay a small amount and let them use it for rent and produce. In the end some neighbors decided they were slow enough to take care and it was now the turn. Regret came periodically, sometimes a week before, and lasted until work actually started. But lately it had been replaced by anxiety when it needed to be passed over to the next caretaker. It did not look their shift was good enough and couldn?t wait to fix it. Today small preparations needed to be made for a class visit next day from a nearby cook school. They were frequenters. It had not been easy, but it shouldn?t have been that hard. In the end, even the easiest things are hard if they involve a city, buildings and neighbors. On the face of the data, the technicalities and the way final designs had been worked out for adaptation to the different settings, the decision of where to go was self evident, but organization issues and the ever-growing politics of taste in a city of already-gentrified-rodents almost put the project in the frozen orbit of timeless beautiful future possibilities. This is how it was. A series of designs by XClinic and OSS had made it possible to adapt to different building structures, leave in most cases the roof untouched and adapted a new technology of flexing fiberglass tubes that dissipated wind pressure in smooth bending.......

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Asia watchers have been kept exceptionally busy by recent political developments in the region. An unprecedented landslide victory in India’s general elections, pro-democracy protests in Hong Kong, close elections in Indonesia, a coup in Thailand – the list goes on. As unrelated as these events appear, analysts may find a missing link among a social group that is currently exploding in numbers: Asia’s middle classes. Often discussed simply in terms of its economic potential, Asia’s middle-income population is also flexing its political muscle. A closer look at its influence throughout the region in recent months seems to confirm for the field of politics what economists have known for some time: The rise of the Asian middle classes constitutes one of the most fundamental transformations of our time. The consequences remain to be seen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The correction of presbyopia and restoration of true accommodative function to the ageing eye is the focus of much ongoing research and clinical work. A range of accommodating intraocular lenses (AIOLs) implanted during cataract surgery has been developed and they are designed to change either their position or shape in response to ciliary muscle contraction to generate an increase in dioptric power. Two main design concepts exist. First, axial shift concepts rely on anterior axial movement of one or two optics creating accommodative ability. Second, curvature change designs are designed to provide significant amplitudes of accommodation with little physical displacement. Single-optic devices have been used most widely, although the true accommodative ability provided by forward shift of the optic appears limited and recent findings indicate that alternative factors such as flexing of the optic to alter ocular aberrations may be responsible for the enhanced near vision reported in published studies. Techniques for analysing the performance of AIOLs have not been standardised and clinical studies have reported findings using a wide range of both subjective and objective methods, making it difficult to gauge the success of these implants. There is a need for longitudinal studies using objective methods to assess long-term performance of AIOLs and to determine if true accommodation is restored by the designs available. While dual-optic and curvature change IOLs are designed to provide greater amplitudes of accommodation than is possible with single-optic devices, several of these implants are in the early stages of development and require significant further work before human use is possible. A number of challenges remain and must be addressed before the ultimate goal of restoring youthful levels of accommodation to the presbyopic eye can be achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes a surgical robotic device that is able to discriminate tissue interfaces and other controlling parameters ahead of the drill tip. The advantage in such a surgery is that the tissues at the interfaces can be preserved. A smart tool detects ahead of the tool point and is able to control the interaction with respect to the flexing tissue, to avoid penetration or to control the extent of protrusion with respect to the position of the tissue. For surgical procedures, where precision is required, the tool offers significant benefit. To interpret the drilling conditions and the conditions leading up to breakthrough at a tissue interface, a sensing scheme is used that discriminates between the variety of conditions posed in the drilling environment. The result is a fully autonomous system, which is able to respond to the tissue type, behaviour, and deflection in real-time. The system is also robust in terms of disturbances encountered in the operating theatre. The device is pragmatic. It is intuitive to use, efficient to set up, and uses standard drill bits. The micro-drill, which has been used to prepare cochleostomies in the theatre, was used to remove the bone tissue leaving the endosteal membrane intact. This has enabled the preservation of sterility and the drilling debris to be removed prior to the insertion of the electrode. It is expected that this technique will promote the preservation of hearing and reduce the possibility of complications. The article describes the device (including simulated drill progress and hardware set-up) and the stages leading up to its use in the theatre. © 2010 Authors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper a surgical robotic device for cochlear implantation surgery is described that is able to discriminate tissue interfaces and other controlling parameters ahead of a drill tip. The advantage in surgery is that tissues at interfaces can be preserved. The smart tool is able to control interaction with respect to the flexing tissue to avoid penetration control the extent of protrusion with respect to the real-time position of the tissue. To interpret drilling conditions, and conditions leading up to breakthrough at a tissue interface, the sensing scheme used enables discrimination between the variety of conditions posed in the drilling environment. The result is a robust fully autonomous system able to respond to tissue type, behaviour and deflection in real-time. The paper describes the robotic tool that has been designed to be used in the surgical environment where it has been used in the operating room.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The engineering of liquid behavior on surfaces is important for infrastructure, transportation, manufacturing, and sensing. Surfaces can be rendered superhydrophobic by microstructuring, and superhydrophobic devices could lead to practical corrosion inhibition, self-cleaning, fluid flow control, and surface drag reduction. To more fully understand how liquid interacts with microstructured surfaces, this dissertation introduces a direct method for determining droplet solid-liquid-vapor interfacial geometry on microstructured surfaces. The technique performs metrology on molten metal droplets deposited onto microstructured surfaces and then frozen. Unlike other techniques, this visualization technique can be used on large areas of curved and opaque microstructured surfaces to determine contact line. This dissertation also presents measurements and models for how curvature and flexing of microstructured polymers affects hydrophobicity. Increasing curvature of microstructured surfaces leads to decreased slide angle for liquid droplets suspended on the surface asperities. For a surface with regularly spaced asperities, as curvature becomes more positive, droplets suspended on the tops of asperities are suspended on fewer asperities. Curvature affects superhydrophobicity because microscopic curvature changes solid-liquid interaction, pitch is altered, and curvature changes the shape of the three phase contact line. This dissertation presents a model of droplet interactions with curved microstructured surfaces that can be used to design microstructure geometries that maintain the suspension of a droplet when curved surfaces are covered with microstructured polymers. Controlling droplet dynamics could improve microfluidic devices and the shedding of liquids from expensive equipment, preventing corrosion and detrimental performance. This dissertation demonstrates redirection of dynamic droplet spray with anisotropic microstructures. Superhydrophobic microstructured surfaces can be economically fabricated using metal embossing masters, so this dissertation describes casting-based microfabrication of metal microstructures and nanostructures. Low melting temperature metal was cast into flexible silicone molds which were themselves cast from microfabricated silicon templates. The flexibility of the silicone mold permits casting of curved surfaces, which this dissertation demonstrates by fabricating a cylindrical metal roller with microstructures. The metal microstructures can be in turn used as a reusable molding tool. This dissertation also describes an industrial investment casting process to produce aluminum molds having integrated microstructures. Unlike conventional micromolding tools, the aluminum mold was large and had complex curved surfaces. The aluminum was cast into curved microstructured ceramic molds which were themselves cast from curved microstructured rubber. Many structures were successfully cast into the aluminum with excellent replication fidelity, including circular, square, and triangular holes. This dissertation demonstrates molding of large, curved surfaces having surface microstructures using the aluminum mold. This work contributes a more full understanding of the phenomenon of superhydrophobicity and techniques for the economic fabrication of superhydrophobic microstructures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ligaments of the wrist are highly variable and poorly described, which is more obvious on the ulnar side of the wrist. Previous studies highlighted the potential differences within the ligaments of the wrist but no consensus has been reached. Poor tissue description and inconsistent use of terminology hindered the reproducibility of the results. Improved understanding of the morphological variations between carpal bones may facilitate improved understanding of the ligamentous structure within the wrist. This study aims to identify the potential variations between carpal bones that could be used to separate palmar ligamentous patterns around the triquetrum-hamate joint into subgroups within the sample population. Investigations were performed following a detailed nomenclature and a clear definition of ligamentous structures to facilitate detailed description and reproducible results. Quantitative analyses were conducted using 3D modelling technique. Histological sections were then analysed to identify the structure of each ligamentous attachment. Variable patterns of ligamentous attachments were identified. Differences were not only obvious between samples but also between the right and left hands of the same person. These identifications suggested that the palmar ligamentous patterns around the triquetrum-hamate joint are best described as a spectrum with a higher affinity of the triquetrum-hamate-capitate ligament and the lunate-triquetrum ligament to be associated with type I lunate wrists on one extreme and type II lunate wrists with the palmar triquetrum-hamate ligament, triquetrum-hamate-capitate ligament and palmar radius-lunate-triquetrum ligament attachments at the other extreme. Histological analyses confirmed pervious established work regarding the mechanical role of ligaments in wrist joint biomechanics. Also, there were no significant differences between the quantitative data obtained from the Genelyn-embalmed and unembalmed specimens (p>0.05). The current study demonstrated variable ligamentous patterns that suggest different bone restraints and two different patterns of motion. These findings support previous suggestions regarding separating the midcarpal joint into two distinct functional types. Type I wrists were identified with ligamentous attachments that are suggestive of rotating/translating hamate whilst type II wrists identified with ligamentous attachments that are suggestive of flexing/extending hamate motion based upon the patterns of the ligamentous attachments in relation to the morphological features of the underlying lunate type of the wrist. This opens the horizon for particular consideration and/or modification of surgical procedures, which may enhance the clinical management of wrist dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flavobacterium columnare é o agente etiológico da columnariose em peixes de água doce, ocasionando enfermidade na pele e nas brânquias, provocando freqüentemente um grande número de mortalidade. O objetivo deste estudo foi o isolamento e a caracterização de Flavobacterium columnare em peixes tropicais no Brasil. Piracanjuba (Brycon orbignyanus), pacu (Piaractus mesopotamicus), tambaqui (Colossoma macropomum) e cascudo (Hypostomus plecostomus) foram examinados externamente com relação a sinais característicos de columnariose, como manchas acinzentadas na cabeça, região dorsal e pedúnculo caudal dos peixes. A amostragem compreendeu a coleta de 50 exemplares de peixes, representando as quatro diferentes espécies escolhidas para este estudo. Amostras para o isolamento foram obtidas através de raspado com swab estéril das lesões e do rim dos peixes clinicamente diagnosticados como acometidos por columnarios e imediatamente semeados em meios de culturas artificiais (líquido e sólido) próprios para o estudo de Flavobacterium segundo Carlson e Pacha (1968). No meio líquido, houve o desenvolvimento de microrganismos que observados em gota pendente apresentaram a forma de bacilos finos, longos, móveis por deslizamento. Através da coloração de Gram, apresentaram morfologia de bacilos finos, Gram negativos, agrupados em colunas. em meio sólido, as colônias eram pequenas, cinza-amareladas, com borda em forma de raiz. No total, foram obtidos quatro isolamentos: 01 cepa de Brycon orbignyanus; 01 cepa de Piaractus mesopotamicus; 01 cepa de Colossoma macropomum; e 01 cepa de Hypostomus plecostomus. A caracterização bioquímica das amostras, como absorção do vermelho Congo, produção de flexirrubina, produção de H2S e redução do nitrato, sugere que os isolamentos poderiam ser classificados como Flavobacterium columnare.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based biodegradable and water soluble adhesive, that will help to retract the PET insertion tool after implantation. As a proof-of-concept of sub-system one, a microfabrication process for patterning PLA stiffeners embedded in parylene has been developed. Conventional hotembossing, mechanical micromachining, and standard cleanroom processes were integrated for patterning fully released and discrete stiffeners coated with parylene. The released embedded stiffeners were thermoformed to demonstrate that imparting perimodiolar shapes to stiffener-embedded arrays will be possible. The developed process when integrated with the array fabrication process will allow fabrication of stiffener-embedded arrays in a single process. As a proof-of-concept of sub-system two, the feasibility of the attaching and detaching mechanism was demonstrated by adhering 1x and 1.5x scale PET tube-based insertion tools and PLA stiffeners embedded in parylene using the copolymer adhesive. The attached devices survived qualitative adhesion tests, thermoforming, and flexing. The viability of the detaching mechanism was tested by aging the assemblies in-vitro in phosphate buffer solution. The average detachment times, 2.6 minutes and 10 minutes for 1x and 1.5x scale devices respectively, were found to be clinically relevant with respect to the reported array insertion times during surgical implantation. Eventually, the stiffener-embedded arrays would not need to be permanently attached to current insertion tools which are left behind after implantation and congest the cochlear scala tympani chamber. Finally, a simulation-based approach for accelerated failure analysis of PLA stiffeners and characterization of PVP-b-PDLLA copolymer adhesive has been explored. The residual functional life of embedded PLA stiffeners exposed to body-fluid and thereby subjected to degradation and erosion has been estimated by simulating PLA stiffeners with different parylene coating failure types and different PLA types for a given parylene coating failure type. For characterizing the PVP-b-PDLLA copolymer adhesive, several formulations of the copolymer adhesive were simulated and compared based on the insertion tool detachment times that were predicted from the dissolution, degradation, and erosion behavior of the simulated adhesive formulations. Results indicate that the simulation-based approaches could be used to reduce the total number of time consuming and expensive in-vitro tests that must be conducted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current approach to data analysis for the Laser Interferometry Space Antenna (LISA) depends on the time delay interferometry observables (TDI) which have to be generated before any weak signal detection can be performed. These are linear combinations of the raw data with appropriate time shifts that lead to the cancellation of the laser frequency noises. This is possible because of the multiple occurrences of the same noises in the different raw data. Originally, these observables were manually generated starting with LISA as a simple stationary array and then adjusted to incorporate the antenna's motions. However, none of the observables survived the flexing of the arms in that they did not lead to cancellation with the same structure. The principal component approach is another way of handling these noises that was presented by Romano and Woan which simplified the data analysis by removing the need to create them before the analysis. This method also depends on the multiple occurrences of the same noises but, instead of using them for cancellation, it takes advantage of the correlations that they produce between the different readings. These correlations can be expressed in a noise (data) covariance matrix which occurs in the Bayesian likelihood function when the noises are assumed be Gaussian. Romano and Woan showed that performing an eigendecomposition of this matrix produced two distinct sets of eigenvalues that can be distinguished by the absence of laser frequency noise from one set. The transformation of the raw data using the corresponding eigenvectors also produced data that was free from the laser frequency noises. This result led to the idea that the principal components may actually be time delay interferometry observables since they produced the same outcome, that is, data that are free from laser frequency noise. The aims here were (i) to investigate the connection between the principal components and these observables, (ii) to prove that the data analysis using them is equivalent to that using the traditional observables and (ii) to determine how this method adapts to real LISA especially the flexing of the antenna. For testing the connection between the principal components and the TDI observables a 10x 10 covariance matrix containing integer values was used in order to obtain an algebraic solution for the eigendecomposition. The matrix was generated using fixed unequal arm lengths and stationary noises with equal variances for each noise type. Results confirm that all four Sagnac observables can be generated from the eigenvectors of the principal components. The observables obtained from this method however, are tied to the length of the data and are not general expressions like the traditional observables, for example, the Sagnac observables for two different time stamps were generated from different sets of eigenvectors. It was also possible to generate the frequency domain optimal AET observables from the principal components obtained from the power spectral density matrix. These results indicate that this method is another way of producing the observables therefore analysis using principal components should give the same results as that using the traditional observables. This was proven by fact that the same relative likelihoods (within 0.3%) were obtained from the Bayesian estimates of the signal amplitude of a simple sinusoidal gravitational wave using the principal components and the optimal AET observables. This method fails if the eigenvalues that are free from laser frequency noises are not generated. These are obtained from the covariance matrix and the properties of LISA that are required for its computation are the phase-locking, arm lengths and noise variances. Preliminary results of the effects of these properties on the principal components indicate that only the absence of phase-locking prevented their production. The flexing of the antenna results in time varying arm lengths which will appear in the covariance matrix and, from our toy model investigations, this did not prevent the occurrence of the principal components. The difficulty with flexing, and also non-stationary noises, is that the Toeplitz structure of the matrix will be destroyed which will affect any computation methods that take advantage of this structure. In terms of separating the two sets of data for the analysis, this was not necessary because the laser frequency noises are very large compared to the photodetector noises which resulted in a significant reduction in the data containing them after the matrix inversion. In the frequency domain the power spectral density matrices were block diagonals which simplified the computation of the eigenvalues by allowing them to be done separately for each block. The results in general showed a lack of principal components in the absence of phase-locking except for the zero bin. The major difference with the power spectral density matrix is that the time varying arm lengths and non-stationarity do not show up because of the summation in the Fourier transform.