985 resultados para Flexible Power Agreement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design of supplementary damping controllers to mitigate the effects of electromechanical oscillations in power systems is a highly complex and time-consuming process, which requires a significant amount of knowledge from the part of the designer. In this study, the authors propose an automatic technique that takes the burden of tuning the controller parameters away from the power engineer and places it on the computer. Unlike other approaches that do the same based on robust control theories or evolutionary computing techniques, our proposed procedure uses an optimisation algorithm that works over a formulation of the classical tuning problem in terms of bilinear matrix inequalities. Using this formulation, it is possible to apply linear matrix inequality solvers to find a solution to the tuning problem via an iterative process, with the advantage that these solvers are widely available and have well-known convergence properties. The proposed algorithm is applied to tune the parameters of supplementary controllers for thyristor controlled series capacitors placed in the New England/New York benchmark test system, aiming at the improvement of the damping factor of inter-area modes, under several different operating conditions. The results of the linear analysis are validated by non-linear simulation and demonstrate the effectiveness of the proposed procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The power required to operate large mills is typically 5-10 MW. Hence, optimisation of power consumption will have a significant impact on overall economic performance and environmental impact. Power draw modelling results using the discrete element code PFC3D have been compared with results derived from the widely used empirical Model of Morrell. This is achieved by calculating the power draw for a range of operating conditions for constant mill size and fill factor using two modelling approaches. fThe discrete element modelling results show that, apart from density, selection of the appropriate material damping ratio is critical for the accuracy of modelling of the mill power draw. The relative insensitivity of the power draw to the material stiffness allows selection of moderate stiffness values, which result in acceptable computation time. The results obtained confirm that modelling of the power draw for a vertical slice of the mill, of thickness 20% of the mill length, is a reliable substitute for modelling the full mill. The power draw predictions from PFC3D show good agreement with those obtained using the empirical model. Due to its inherent flexibility, power draw modelling using PFC3D appears to be a viable and attractive alternative to empirical models where necessary code and computer power are available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Power systems have been suffering huge changes mainly due to the substantial increase of distributed generation and to the operation in competitive environments. Virtual power players can aggregate a diversity of players, namely generators and consumers, and a diversity of energy resources, including electricity generation based on several technologies, storage and demand response. Resource management gains an increasing relevance in this competitive context, while demand side active role provides managers with increased demand elasticity. This makes demand response use more interesting and flexible, giving rise to a wide range of new opportunities.This paper proposes a methodology for managing demand response programs in the scope of virtual power players. The proposed method is based on the calculation of locational marginal prices (LMP). The evaluation of the impact of using demand response specific programs on the LMP value supports the manager decision concerning demand response use. The proposed method has been computationally implemented and its application is illustrated in this paper using a 32 bus network with intensive use of distributed generation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a complete, quadratic programming formulation of the standard thermal unit commitment problem in power generation planning, together with a novel iterative optimisation algorithm for its solution. The algorithm, based on a mixed-integer formulation of the problem, considers piecewise linear approximations of the quadratic fuel cost function that are dynamically updated in an iterative way, converging to the optimum; this avoids the requirement of resorting to quadratic programming, making the solution process much quicker. From extensive computational tests on a broad set of benchmark instances of this problem, the algorithm was found to be flexible and capable of easily incorporating different problem constraints. Indeed, it is able to tackle ramp constraints, which although very important in practice were rarely considered in previous publications. Most importantly, optimal solutions were obtained for several well-known benchmark instances, including instances of practical relevance, that are not yet known to have been solved to optimality. Computational experiments and their results showed that the method proposed is both simple and extremely effective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Demands for functionality enhancements, cost reductions and power savings clearly suggest the introduction of multiand many-core platforms in real-time embedded systems. However, when compared to uni-core platforms, the manycores experience additional problems, namely the lack of scalable coherence mechanisms and the necessity to perform migrations. These problems have to be addressed before such systems can be considered for integration into the realtime embedded domain. We have devised several agreement protocols which solve some of the aforementioned issues. The protocols allow the applications to plan and organise their future executions both temporally and spatially (i.e. when and where the next job will be executed). Decisions can be driven by several factors, e.g. load balancing, energy savings and thermal issues. All presented protocols are analytically described, with the particular emphasis on their respective real-time behaviours and worst-case performance. The underlying assumptions are based on the multi-kernel model and the message-passing paradigm, which constitutes the communication between the interacting instances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cloud SLAs compensate customers with credits when average availability drops below certain levels. This is too inflexible because consumers lose non-measurable amounts of performance being only compensated later, in next charging cycles. We propose to schedule virtual machines (VMs), driven by range-based non-linear reductions of utility, different for classes of users and across different ranges of resource allocations: partial utility. This customer-defined metric, allows providers transferring resources between VMs in meaningful and economically efficient ways. We define a comprehensive cost model incorporating partial utility given by clients to a certain level of degradation, when VMs are allocated in overcommitted environments (Public, Private, Community Clouds). CloudSim was extended to support our scheduling model. Several simulation scenarios with synthetic and real workloads are presented, using datacenters with different dimensions regarding the number of servers and computational capacity. We show the partial utility-driven driven scheduling allows more VMs to be allocated. It brings benefits to providers, regarding revenue and resource utilization, allowing for more revenue per resource allocated and scaling well with the size of datacenters when comparing with an utility-oblivious redistribution of resources. Regarding clients, their workloads’ execution time is also improved, by incorporating an SLA-based redistribution of their VM’s computational power.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação para a Ciência e a Tecnologia (FCT) - (PTDC/EBB-EBI/102266/2008 and SFRH/BD/43830/2008, respectively) and by European Community’s FP7/2007-2013 (grant agreement nº 270089)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de Doutoramento Programa Doutoral em Engenharia Electrónica e Computadores.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The demand for computational power has been leading the improvement of the High Performance Computing (HPC) area, generally represented by the use of distributed systems like clusters of computers running parallel applications. In this area, fault tolerance plays an important role in order to provide high availability isolating the application from the faults effects. Performance and availability form an undissociable binomial for some kind of applications. Therefore, the fault tolerant solutions must take into consideration these two constraints when it has been designed. In this dissertation, we present a few side-effects that some fault tolerant solutions may presents when recovering a failed process. These effects may causes degradation of the system, affecting mainly the overall performance and availability. We introduce RADIC-II, a fault tolerant architecture for message passing based on RADIC (Redundant Array of Distributed Independent Fault Tolerance Controllers) architecture. RADIC-II keeps as maximum as possible the RADIC features of transparency, decentralization, flexibility and scalability, incorporating a flexible dynamic redundancy feature, allowing to mitigate or to avoid some recovery side-effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We analyze the statistics of rain-event sizes, rain-event durations, and dry-spell durations in a network of 20 rain gauges scattered in an area situated close to the NW Mediterranean coast. Power-law distributions emerge clearly for the dryspell durations, with an exponent around 1.50 ± 0.05, although for event sizes and durations the power-law ranges are rather limited, in some cases. Deviations from power-law behavior are attributed to finite-size effects. A scaling analysis helps to elucidate the situation, providing support for the existence of scale invariance in these distributions. It is remarkable that rain data of not very high resolution yield findings in agreement with self-organized critical phenomena.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Some historians have argued that 1996 marked a ‘second transition’ for Spain because of the return to power of the political right in Madrid and that the relationship and eventual pact between the Partido Popular (PP) and Convergència i Unió (CiU) meant that the state could finally escape the ghosts of its Francoist past. For this research, face-to-face interviews were conducted with Catalan Members of Parliament who served under either José María Aznar or Jordi Pujol in Madrid or Barcelona. Drawing upon both interviews and other evidence, including the analysis of election results and the 1996 Hotel Majestic Agreement, the research seeks to provide a better understanding of the previous relationships between the PP and CiU and their leaders in order to understand what lessons might be learnt that would contribute to anticipating and explaining possible future negotiations between the two parties. This is attempted by first examining the potential costs and benefits of political pacts between centre (Madrid) and periphery (Barcelona). Secondly, due to many interviewees making reference to Salvador Espriu’s work La Pell de Brau, the three routes of Espriu’s Catalan nationalism are put into the context of the political pacts. Finally, the likelihood of future agreements between PP and CiU are hypothesized, not only how those agreements may (or may not) come about, but also, what might the result of those negotiations be. Ultimately, it is concluded that the benefits of the Hotel Majestic Agreement outweighed the costs, thus leaving the door open for future negotiations, even if some of those interviewed disagreed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a novel approach to N-person bargaining, based on the idea thatthe agreement reached in a negotiation is determined by how the directconflict resulting from disagreement would be resolved. Our basic buildingblock is the disagreement function, which maps each set of feasible outcomesinto a disagreement point. Using this function and a weak axiom basedon individual rationality we reach a unique solution: the agreement inthe shadow of conflict, ASC. This agreement may be construed as the limitof a sequence of partial agreements, each of which is reached as a functionof the parties relative power. We examine the connection between ASC andasymmetric Nash solutions. We show the connection between the power ofthe parties embodied in the ASC solution and the bias in the SWF thatwould select ASC as an asymmetric Nash solution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a novel multifactor dimensionality reduction method for epistasis detection in small or extended pedigrees, FAM-MDR. It combines features of the Genome-wide Rapid Association using Mixed Model And Regression approach (GRAMMAR) with Model-Based MDR (MB-MDR). We focus on continuous traits, although the method is general and can be used for outcomes of any type, including binary and censored traits. When comparing FAM-MDR with Pedigree-based Generalized MDR (PGMDR), which is a generalization of Multifactor Dimensionality Reduction (MDR) to continuous traits and related individuals, FAM-MDR was found to outperform PGMDR in terms of power, in most of the considered simulated scenarios. Additional simulations revealed that PGMDR does not appropriately deal with multiple testing and consequently gives rise to overly optimistic results. FAM-MDR adequately deals with multiple testing in epistasis screens and is in contrast rather conservative, by construction. Furthermore, simulations show that correcting for lower order (main) effects is of utmost importance when claiming epistasis. As Type 2 Diabetes Mellitus (T2DM) is a complex phenotype likely influenced by gene-gene interactions, we applied FAM-MDR to examine data on glucose area-under-the-curve (GAUC), an endophenotype of T2DM for which multiple independent genetic associations have been observed, in the Amish Family Diabetes Study (AFDS). This application reveals that FAM-MDR makes more efficient use of the available data than PGMDR and can deal with multi-generational pedigrees more easily. In conclusion, we have validated FAM-MDR and compared it to PGMDR, the current state-of-the-art MDR method for family data, using both simulations and a practical dataset. FAM-MDR is found to outperform PGMDR in that it handles the multiple testing issue more correctly, has increased power, and efficiently uses all available information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A mathematical model of the voltage drop which arises in on-chip power distribution networks is used to compare the maximum voltage drop in the case of different geometric arrangements of the pads supplying power to the chip. These include the square or Manhattan power pad arrangement, which currently predominates, as well as equilateral triangular and hexagonal arrangements. In agreement with the findings in the literature and with physical and SPICE models, the equilateral triangular power pad arrangement is found to minimize the maximum voltage drop. This headline finding is a consequence of relatively simple formulas for the voltage drop, with explicit error bounds, which are established using complex analysis techniques, and elliptic functions in particular.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’Escola Politècnica Superior de la Universitat de Vic disposa d’una cèl·lula de fabricació flexible del fabricant Festo, que simula un procés d’emmagatzematge automàtic, aquesta cèl·lula esta composta per quatre estacions de muntatge diferenciades i independents, l’estació palets, l’estació plaques, l’estació magatzem intermedi i l’estació transport. Cada una d’aquestes estacions està formada per sensors i actuadors elèctrics i pneumàtics del fabricant Festo que van connectats a un PLC SIEMENS S7-300.Els quatre PLC’s (un per cada estació) estan connectats entre ells mitjançant el bus de comunicacions industrials Profibus. L’objectiu d’aquest treball consisteix en l’adaptació de la programació dels PLC’s i la realització d’un SCADA per tal de controlar el funcionament del conjunt de la cèl·lula de fabricació a través del software Vijeo Citect, d’aquesta manera es coneixerà el funcionament de la cèl·lula i permetrà treure’n rendiment per la docència. Aquest projecte ha estat realitzat en quatre fases principals. 1. Estudi i coneixement de les estacions, en aquesta fase s’han estudiat els manuals de funcionament de les estacions i s’han interpretat els codis de programació dels seus PLCs, amb l’objectiu de conèixer bé el programa per tal de interaccionar-hi més endavant amb el sistema SCADA 2. Disseny i programació del sistema SCADA, en aquesta fase s’ha realitzat tot el disseny gràfic de les pantalles de la interfície SCADA així com la programació dels objectes, la connexió amb els PLCs i la base de dades. 3. Posada en marxa del sistema complert, quan es coneixia abastament el funcionament de les estacions i el sistema SCADA estava completat s’ha fet la posada en marxa del conjunt i s’ha comprovat el correcte funcionament i interacció dels sistemes. 4. Realització de la memòria del projecte, en aquesta ultima fase s’ha realitzat la memòria del projecte on s’expliquen les característiques i funcionament de totes les estacions i del sistema SCADA. La conclusió més rellevant obtinguda en aquest treball, és la clara visualització de la potència i simplicitat que han aportat els sistemes SCADA al món de l’automatització, anys enrere per la supervisió de l’estat d’un sistema automatitzat era necessari disposar d’un gran espai amb grans panells de control formats per una gran quantitat de pilots lluminosos, potenciòmetres, interruptors, polsadors, displays i sobretot un voluminós i complexa cablejat, gràcies als sistemes SCADA avui en dia tot això pot quedar reduït a un PC o terminal tàctil, amb pantalles gràfiques clares i una gran quantitat d’opcions de supervisió control i configuració del sistema automatitzat.