990 resultados para Fire testing.
Resumo:
Mode of access: Internet.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
The objective for this thesis is to outline a Performance-Based Engineering (PBE) framework to address the multiple hazards of Earthquake (EQ) and subsequent Fire Following Earthquake (FFE). Currently, fire codes for the United States are largely empirical and prescriptive in nature. The reliance on prescriptive requirements makes quantifying sustained damage due to fire difficult. Additionally, the empirical standards have resulted from individual member or individual assembly furnace testing, which have been shown to differ greatly from full structural system behavior. The very nature of fire behavior (ignition, growth, suppression, and spread) is fundamentally difficult to quantify due to the inherent randomness present in each stage of fire development. The study of interactions between earthquake damage and fire behavior is also in its infancy with essentially no available empirical testing results. This thesis will present a literature review, a discussion, and critique of the state-of-the-art, and a summary of software currently being used to estimate loss due to EQ and FFE. A generalized PBE framework for EQ and subsequent FFE is presented along with a combined hazard probability to performance objective matrix and a table of variables necessary to fully implement the proposed framework. Future research requirements and summary are also provided with discussions of the difficulties inherent in adequately describing the multiple hazards of EQ and FFE.
Resumo:
Objectives: The purpose of this study was to evaluate the effectiveness of the Danger Rangers Fire Safety Curriculum in increasing the fire safety knowledge of low-income, minority children in pre-kindergarten to third grade in Austin, TX during a summer day camp in 2007.^ Methods: Data was collected from child participants via teacher and researcher administered tests at pretest, posttest (immediately after the completion of the fire safety module), and at a 3 week follow-up to asses retention. In addition, a self-administered questionnaire was collected from parents pre- and post-intervention to assess home-related fire/burn risk factors. Paired t-tests were conducted using STATA 12.0 to evaluate pretest, posttest, and retention test mean scores as well as mean fire safety rules listed by grade group. McNemar's test was used to determine if there was a difference in fire-related risk factors as reported by the parents of the participants before and after the intervention. Only those who had paired data for the tests/surveys being compared were included in the analysis.^ Results: The first/second grade group and the third grade group scored significantly higher on fire safety knowledge on the posttest compared to the pretest (p<0.0001 for both groups). However, there was no significant change in knowledge scores for the pre-kindergarten to kindergarten group (p=0.14). Among the first/second grade group, knowledge levels did not significantly decline between the posttest and retention test (p=0.25). However, the third grade group had significantly lower fire safety knowledge scores on the retention test compared to the posttest (p<0.001). A similar increase was seen in the amount of fire safety rules listed after the intervention (p<0.0001 between pre and posttest for both the first/second grade and third grade groups), with no decline from the posttest to the retention test (p=0.50) for the first/second grade group, but a significant decline in the third grade group (p=0.001). McNemar's chi-square test showed a significant increase in the percentage of participants' parents reporting smoke detector testing on a regular basis and having a fire escape plan for their family after the intervention (p=0.01 and p<0.0001, respectively). However, there was no significant change in the frequency of reports of the child playing in the kitchen while the parent cooks or the house/apartment having a working smoke detector.^ Conclusion: We found that general fire safety knowledge improved and the number of specific fire safety rules increased among the first to third grade children who participated in the Danger Rangers fire safety program. However, it did not significantly increase general fire safety knowledge among the pre-k/k group. This study also showed that a program targeted towards children has the potential to influence familial risk factors by proxy. The Danger Rangers Fire Safety Curriculum should be further evaluated by conducting a randomized controlled trial, using valid measures that assess fire safety attitudes, beliefs, behaviors, as well as fire/burn related outcomes.^
Resumo:
National Highway Traffic Safety Administration, Office of Vehicle Safety Compliance, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Office of Vehicle Safety Compliance, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
The aim of this project was to carry out a fundamental study to assess the potential of colour image analysis for use in investigations of fire damaged concrete. This involved:(a) Quantification (rather than purely visual assessment) of colour change as an indicator of the thermal history of concrete.(b) Quantification of the nature and intensity of crack development as an indication of the thermal history of concrete, supporting and in addition to, colour change observations.(c) Further understanding of changes in the physical and chemical properties of aggregate and mortar matrix after heating.(d) An indication of the relationship between cracking and non-destructive methods of testing e.g. UPV or Schmidt hammer. Results showed that colour image analysis could be used to quantify the colour changes found when concrete is heated. Development of red colour coincided with significant reduction in compressive strength. Such measurements may be used to determine the thermal history of concrete by providing information regarding the temperature distribution that existed at the height of a fire. The actual colours observed depended on the types of cement and aggregate that were used to make the concrete. With some aggregates it may be more appropriate to only analyse the mortar matrix. Petrographic techniques may also be used to determine the nature and density of cracks developing at elevated temperatures and values of crack density correlate well with measurements of residual compressive strength. Small differences in crack density were observed with different cements and aggregates, although good correlations were always found with the residual compressive strength. Taken together these two techniques can provide further useful information for the evaluation of fire damaged concrete. This is especially so since petrographic analysis can also provide information on the quality of the original concrete such as cement content and water / cement ratio. Concretes made with blended cements tended to produce small differences in physical and chemical properties compared to those made with unblended cements. There is some evidence to suggest that a coarsening of pore structure in blended cements may lead to onset of cracking at lower temperatures. The use of DTA/TGA was of little use in assessing the thermal history of concrete made with blended cements. Corner spalling and sloughing off, as observed in columns, was effectively reproduced in tests on small scale specimens and the crack distributions measured. Relationships between compressive strength/cracking and non-destructive methods of testing are discussed and an outline procedure for site investigations of fire damaged concrete is described.
Resumo:
Increased device density, switching speeds of integrated circuits and decrease in package size is placing new demands for high power thermal-management. The convectional method of forced air cooling with passive heat sink can handle heat fluxes up-to 3-5W/cm2; however current microprocessors are operating at levels of 100W/cm2, This demands the usage of novel thermal-management systems. In this work, water-cooling systems with active heat sink are embedded in the substrate. The research involved fabricating LTCC substrates of various configurations - an open-duct substrate, the second with thermal vias and the third with thermal vias and free-standing metal columns and metal foil. Thermal testing was performed experimentally and these results are compared with CFD results. An overall thermal resistance for the base substrate is demonstrated to be 3.4oC/W-cm2. Addition of thermal vias reduces the effective resistance of the system by 7times and further addition of free standing columns reduced it by 20times.
Resumo:
I explore and analyze a problem of finding the socially optimal capital requirements for financial institutions considering two distinct channels of contagion: direct exposures among the institutions, as represented by a network and fire sales externalities, which reflect the negative price impact of massive liquidation of assets.These two channels amplify shocks from individual financial institutions to the financial system as a whole and thus increase the risk of joint defaults amongst the interconnected financial institutions; this is often referred to as systemic risk. In the model, there is a trade-off between reducing systemic risk and raising the capital requirements of the financial institutions. The policymaker considers this trade-off and determines the optimal capital requirements for individual financial institutions. I provide a method for finding and analyzing the optimal capital requirements that can be applied to arbitrary network structures and arbitrary distributions of investment returns.
In particular, I first consider a network model consisting only of direct exposures and show that the optimal capital requirements can be found by solving a stochastic linear programming problem. I then extend the analysis to financial networks with default costs and show the optimal capital requirements can be found by solving a stochastic mixed integer programming problem. The computational complexity of this problem poses a challenge, and I develop an iterative algorithm that can be efficiently executed. I show that the iterative algorithm leads to solutions that are nearly optimal by comparing it with lower bounds based on a dual approach. I also show that the iterative algorithm converges to the optimal solution.
Finally, I incorporate fire sales externalities into the model. In particular, I am able to extend the analysis of systemic risk and the optimal capital requirements with a single illiquid asset to a model with multiple illiquid assets. The model with multiple illiquid assets incorporates liquidation rules used by the banks. I provide an optimization formulation whose solution provides the equilibrium payments for a given liquidation rule.
I further show that the socially optimal capital problem using the ``socially optimal liquidation" and prioritized liquidation rules can be formulated as a convex and convex mixed integer problem, respectively. Finally, I illustrate the results of the methodology on numerical examples and
discuss some implications for capital regulation policy and stress testing.
Resumo:
The literature on the determination of flammability limits was reviewed and experts on the ASTM E681 standard were interviewed to identify new means of improving the reproducibility of the ASTM E681 test. Venting was identified as a variable of flammability limits not yet addressed. Limitations of the current system for sealing and venting (a rubber stopper) were identified and addressed by the development of a custom burst disc. The burst disc was evaluated for its ability to hold and maintain a vacuum, its ability to vent at pressures of interest, and for its venting phenomena. The burst disc was deemed to be a satisfactory alternative to the rubber stopper and is recommended to be included in the ASTM E681 standard.
Resumo:
Fire management is a common practice in several reserves in the Cerrado, but its influences on bird reproduction remain unknown. In addition, the nesting biology of the Burrowing Owl (Athene cunicularia) has been studied in numerous environments, but not in tropical grasslands managed by fire. This study examined the effects of fire management on the nesting biology of A. cunicularia in Emas National Park, State of Goias, central Brazilian Cerrado. We compared the number of breeding pairs and their burrows in October and November 2009 at 15 study sites in grasslands managed by fire (firebreaks) and unmanaged grasslands adjacent to and distant from firebreaks. We visited active burrows two-four times and described the burrow entrances and sentinel sites and counted and observed adults and young. A total of 19 burrows were found at firebreaks. One and two burrows were found in grasslands adjacent to and distant from firebreaks, respectively. For all burrows found, one to three young reached the adult size, being able to fly and/or run in early November. The 22 burrows found were in the ground, associated or not with termite and ant nests. Most (86.4%) burrows had only one entrance. Only three burrows had two or three entrances. Structures used as sentinel perches by adults were mounds in front of the burrow entrances, termite nests, shrubs and trees. Most of these sentinel sites were shorter than 2 m high and located less than 10 m from the burrow entrance. At Emas National Park, firebreaks appear to provide more attractive conditions to the nesting of A. cunicularia than unmanaged grasslands, likely because of the short herbaceous stratum due to frequent burning of firebreaks. This study suggests that fire management provides suitable conditions for the successful reproduction of A. cunicularia in firebreaks at Emas National Park.
Resumo:
In about 50% of first trimester spontaneous abortion the cause remains undetermined after standard cytogenetic investigation. We evaluated the usefulness of array-CGH in diagnosing chromosome abnormalities in products of conception from first trimester spontaneous abortions. Cell culture was carried out in short- and long-term cultures of 54 specimens and cytogenetic analysis was successful in 49 of them. Cytogenetic abnormalities (numerical and structural) were detected in 22 (44.89%) specimens. Subsequent, array-CGH based on large insert clones spaced at ~1 Mb intervals over the whole genome was used in 17 cases with normal G-banding karyotype. This revealed chromosome aneuplodies in three additional cases, giving a final total of 51% cases in which an abnormal karyotype was detected. In keeping with other recently published works, this study shows that array-CGH detects abnormalities in a further ~10% of spontaneous abortion specimens considered to be normal using standard cytogenetic methods. As such, array-CGH technique may present a suitable complementary test to cytogenetic analysis in cases with a normal karyotype.