973 resultados para Film-coating


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns.Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05).Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05).Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The family of bismuth titanate, Bi(4)Ti(3)O(12) (BIT) layered-structured ferroelectrics materials is attractive from the viewpoint of such as their application as electronic materials dielectrics, piezoelectrics and pyroelectrics, because they are characterized by good stability of piezoelectric properties, a high Curie temperature and a good resistance vs temperature. Bismuth titanate (Bi(4)Ti(3)O(12)) powders can be prepared using different methods, depending if the creation will be film coating or ceramics. The structure and properties of bismuth titanate materials show a significance dependence on the applied synthesis method. In this review paper, we made an attempt to give an approach to analyszing the structure, synthesis methods and properties of bismuth titanate ferroelectrics materials.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work pellets containing chitosan for colonic drug delivery were developed. The influence of the polysaccharide in the pellets was evaluated by swelling, drug dissolution and intestinal permeation studies. Drug-loaded pellets containing chitosan as swellable polymer were coated with an inner layer of Kollicoat® SR 30 D and an outer layer of the enteric polymer Kollicoat® MAE 30 DP in a fluidized-bed apparatus. Metronidazole released from pellets was assessed using Bio-Dis dissolution method. Swelling, drug release and intestinal permeation were dependent on the chitosan and the coating composition. The drug release data fitted well with the Weibull equation, indicating that the drug release was controlled by diffusion, polymer relaxation and erosion occurring simultaneously. The film coating was found to be the main factor controlling the drug release and the chitosan controlling the drug intestinal permeation. Coated pellets containing chitosan show great potential as a system for drug delivery to the colon. © 2012 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Plasmon-enhanced spectroscopic techniques have expanded single-molecule detection (SMD) and are revolutionizing areas such as bio-imaging and single-cell manipulation. Surface-enhanced (resonance) Raman scattering (SERS or SERRS) combines high sensitivity with molecularfingerprint information at the single-molecule level. Spectra originating from single-molecule SERS experiments are rare events, which occur only if a single molecule is located in a hot-spot zone. In this spot, the molecule is selectively exposed to a significant enhancement associated with a high, local electromagnetic field in the plasmonic substrate. Here, we report an SMD study with an electrostatic approach in which a Langmuir film of a phospholipid with anionic polar head groups (PO 4 -) was doped with cationic methylene blue (MB), creating a homogeneous, two-dimensional distribution of dyes in the monolayer. The number of dyes in the probed area of the Langmuir-Blodgett (LB) film coating the Ag nanostructures established a regime in which single-molecule events were observed, with the identification based on direct matching of the observed spectrum at each point of the mapping with a reference spectrum for the MB molecule. In addition, advanced fitting techniques were tested with the data obtained from micro-Raman mapping, thus achieving real-time processing to extract the MB single-molecule spectra. © 2013 Society for Applied Spectroscopy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns. Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05). Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05). Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to prepare and characterize coated pellets for controlled drug delivery. The influence of chitosan (CS) in pellets was evaluated by swelling, in vitro drug release and intestinal permeation assays. Pellets were coated with an enteric polymer, Kollicoat (R) MAE 30 DP, in a fluidized-bed apparatus and the coating formulations were based on a factorial design. Metronidazole (MT) released from coated and uncoated pellets were assessed by dissolution method using Apparatus I. Intestinal permeation was evaluated by everted intestinal sac model in rats, used to study the absorption of MT from coated pellets containing CS or not through the intestinal tissue. Although the film coating avoided drug dissolution in gastric medium, the overall drug release and intestinal permeation were dependent on the presence of CS. Thus, pellets containing CS show potential as a system for controlled drug delivery. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work a generally applicable method for the preparation of mucoadhesive micropellets of 250 to 600µm diameter is presented using rotor processing without the use of electrolytes. The mucoadhesive micropellets were developed to combine the advantages of mucoadhesion and microparticles. It was possible to produce mucoadhesive micropellets based on different mucoadhesive polymers Na-CMC, Na-alginate and chitosan. These micropellets are characterized by a lower friability (6 to 17%) when compared to industrial produced cellulose pellets (Cellets®) (41.5%). They show great tapped density and can be manufactured at high yields. The most influencing variables of the process are the water content at the of the end spraying period, determined by the liquid binder amount, the spraying rate, the inlet air temperature, the airflow and the humidity of the inlet air and the addition of the liquid binder, determined by the spraying rate, the rotor speed and the type of rotor disc. In a subsequent step a fluidized bed coating process was developed. It was possible to manifest a stable process in the Hüttlin Mycrolab® in contrast to the Mini-Glatt® apparatus. To reach enteric resistance, a 70% coating for Na-CMC micropellets, an 85% for chitosan micropellets and a 140% for Na-alginate micropellets, based on the amount of the starting micropellets, was necessary. Comparative dissolution experiments of the mucoadhesive micropellets were performed using the paddle apparatus with and without a sieve inlay, the basket apparatus, the reciprocating cylinder and flow-through cell. The paddle apparatus and the modified flow-through cell method turned out to be successful methods for the dissolution of mucoadhesive micropellets. All dissolution profiles showed an initial burst release followed by a slow release due to diffusion control. Depending on the method, the dissolution profiles changed from immediate release to slow release. The dissolution rate in the paddle apparatus was mainly influenced by the agitation rate whereas the flow-through cell pattern was mainly influenced by the particle size. Also, the logP and the HLB values of different emulsifiers were correlated to transfer HLB values of excipients into logP values and logP values of API´s into HLB values. These experiments did not show promising results. Finally, it was shown that manufacture of mucoadhesive micropellets is successful resulting in product being characterized by enteric resistency combined with high yields and convincing morphology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This PhD thesis focused on nanomaterial (NM) engineering for occupational health and safety, in the frame of the EU project “Safe Nano Worker Exposure Scenarios (SANOWORK)”. Following a safety by design approach, surface engineering (surface coating, purification process, colloidal force control, wet milling, film coating deposition and granulation) were proposed as risk remediation strategies (RRS) to decrease toxicity and emission potential of NMs within real processing lines. In the first case investigated, the PlasmaChem ZrO2 manufacturing, the colloidal force control applied to the washing of synthesis rector, allowed to reduce ZrO2 contamination in wastewater, performing an efficient recycling procedure of ZrO2 recovered. Furthermore, ZrO2 NM was investigated in the ceramic process owned by CNR-ISTEC and GEA-Niro; the spray drying and freeze drying techniques were employed decreasing NM emissivity, but maintaining a reactive surface in dried NM. Considering the handling operation of nanofibers (NFs) obtained through Elmarco electrospinning procedure, the film coating deposition was applied on polyamide non-woven to avoid free fiber release. For TiO2 NF the wet milling was applied to reduce and homogenize the aspect ratio, leading to a significant mitigation of fiber toxicity. In the Colorobbia spray coating line, Ag and TiO2 nanosols, employed to transfer respectively antibacterial or depolluting properties to different substrates, were investigated. Ag was subjected to surface coating and purification, decreasing NM toxicity. TiO2 was modified by surface coating, spray drying and blending with colloidal SiO2, improving its technological performance. In the extrusion of polymeric matrix charged with carbon nanotube (CNTs) owned by Leitat, the CNTs used as filler were granulated by spray drying and freeze spray drying techniques, allowing to reduce their exposure potential. Engineered NMs tested by biologists were further investigated in relevant biological conditions, to improve the knowledge of structure/toxicity mechanisms and obtain new insights for the design of safest NMs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In der Form von Nanokapseln (AmB-HST), Nanoemulsion beziehungsweise multilamellaren Vesikeln (MLV) wurden drei Amphotericin-B-Formulierungen für die orale Applikation entwickelt, charakterisiert und verglichen. Die neuartige homogene Nanokapsel-Formulierung des hydrophoben Polyen-Antimykotikums Amphotericin B wurde in Analogie zu einem für Simvastatin und andere Arzneistoffe etablierten Prozess aus der Reinsubstanz, Lezithin und Gelatine mit Hilfe des HST-Verfahrens hergestellt. Photometrische Untersuchungen zeigten, dass das Endprodukt aus Monomeren aufgebaut ist. Mittels Mikroskopie ließen sich die Aggregate vor der Umhüllung mit Lezithin und Gelatine im Ausgangsmaterial als individuelle kugelförmige Arzneistoffpartikel darstellen. Strukturuntersuchungen mit dynamischer licht streuung (DLS) zeigten eine enge Größenverteilung der verkapselten Partikel von ca. 1 µm. Die Struktur der Hülle der HST-Partikel wurde erstmalig mit Neutronenstreuung unter Verwendung der Deuterium-basierten Lösungsmittel kontrastmethode aufgeklärt. Durch die teilweise Kontrastmaskierung des Partikelkerns bei der Neutronenstreuung konnte die Lezithin-Gelatine-Hülle als eine dünne, 5,64 ± 0.18 nm dicke Schicht aufgelöst werden, welche der biologischen Lipidmembran ähnlich, im Vergleich aber geringfügig größer ist. Dieses Resultat eröffnet Wege für die Optimierung der Formulierung von pharmazeutischen Nanopartikeln, z.B. durch Oberflächenmodifizierungen. Weitere Untersuchungen mittels Kleinwinkelneutronenstreuung unter Verwendung der D-Kontrastvariation deuten darauf hin, dass die Komponenten der Nanokapseln nicht den gleichen Masseschwerpunkt haben, sondern asymmetrisch aufgebaut sind und dass die stärker streuenden Domänen weiter außen liegen. Die Partikel sind im Vergleich zu Liposomen dichter. In-Vitro Freisetzungsstudien belegen das Solubilisierungsvermögen des HST-Systems, wonach die Freisetzung des Arzneistoffes aus der Formulierung zu allen gemessenen Zeitpunkten höher als diejenige der Reinsubstanz war. rnDie Nanoemulsion-Formulierung von Amphotericin B wurde mit einem Öl und Tensid system, jedoch mit unterschiedlichen Co-Solvenzien, erfolgreich entwickelt. Gemäß der Bestimmung der Löslichkeit in verschiedenen Hilfsstoffen erwies sich der Arzneistoff Amphotericin B als nicht-lipophil, gleichzeitig aber auch als nicht-hydrophil. Die zur Ermittlung der für die Emulsionsbildung notwendigen Hilfstoffkonzentrationen erstellten ternären Diagramme veranschaulichten, dass hohe Öl- und Tensidgehalte zu keiner Emulsionsbildung führten. Dementsprechend betrug der höchste Ölgehalt 10%. Die Tröpfchengröße wuchs mit zunehmender Tensidkonzentration, wobei die Co-Solventmenge der Propylenglykol-haltigen Nanoemulsion indirekt verringert wurde. Für die Transcutol®P-haltige Nanoemulsion hingegen wurde das Gegenteil beobachtet, nämlich eine Abnahme der Tröpfchengröße bei steigenden Tensidkonzentrationen. Durch den Einschluss des Arzneistoffes wurde nicht die Viskosität der Formulierung, sondern die Tröpfchengröße beeinflusst. Der Wirkstoffeinschluss führte zu höheren Tröpfchengrößen. Mit zunehmender Propylenglykolkonzentration wurde der Wirkstoffgehalt erhöht, mit zunehmender Transcutol®P-Konzentration dagegen vermindert. UV/VIS-spektroskopische Analysen deuten darauf hin, dass in beiden Formulierungen Amphotericin B als Monomer vorliegt. Allerdings erwiesen sich die Formulierungen Caco-2-Zellen und humanen roten Blutkörperchen gegenüber als toxisch. Da die Kontrollproben eine höhere Toxizität als die wirkstoffhaltigen Formulierungen zeigten, ist die Toxizität nicht nur auf Amphotericin, sondern auch auf die Hilfsstoffe zurückzuführen. Die solubilisierte Wirkstoffmenge ist in beiden Formulierungen nicht ausreichend im Hinblick auf die eingesetzte Menge an Hilfsstoff nach WHO-Kriterien. Gemäß diesen Untersuchungen erscheinen die Emulsions-Formulierungen für die orale Gabe nicht geeignet. Dennoch sind Tierstudien notwendig, um den Effekt bei Tieren sowie die systemisch verfügbare Wirkstoffmenge zu ermitteln. Dies wird bestandskräftige Schlussfolgerungen bezüglich der Formulierung und Aussagen über mögliche Perspektiven erlauben. Nichtsdestotrotz sind die Präkonzentrate sehr stabil und können bei Raumtemperatur gelagert werden.rnDie multilamellar-vesikulären Formulierungen von Amphotericin B mit ungesättigten und gesättigten neutralen Phospholipiden und Cholesterin wurden erfolgreich entwickelt und enthielten nicht nur Vesikel, sondern auch zusätzliche Strukturen bei zunehmender Cholesterinkonzentration. Mittels Partikelgrößenanalyse wurden bei den Formulierungen mit gesättigten Lipiden Mikropartikel detektiert, was abhängig von der Alkylkettenlänge war. Mit dem ungesättigten Lipid (DOPC) konnten hingegen Nanopartikel mit hinreichender Verkapselung und Partikelgrößenverteilung gebildet werden. Die Ergebnisse der thermischen und FTIR-spektroskopischen Analyse, welche den Einfluss des Arzneistoffes ausschließen ließen, liefern den Nachweis für die mögliche, bereits in der Literatur beschriebene Einlagerung des Wirkstoffs in lipid- und/oder cholesterinreiche Membranen. Mit Hilfe eines linearen Saccharosedichtegradienten konnte die Formulierung in Vesikel und Wirkstoff-Lipid-Komplexe nach bimodaler Verteilung aufgetrennt werden, wobei der Arzneistoff stärker mit den Komplexen als mit den Vesikeln assoziiert ist. Bei den Kleinwinkelneutronenstreu-Experimenten wurde die Methode der Kontrastvariation mit Erfolg angewendet. Dabei konnte gezeigt werden, dass Cholesterol in situ einen Komplex mit Amphotericin B bildet. Diesen Sachverhalt legt unter anderem die beobachtete Differenz in der äquivalenten Streulängendichte der Wirkstoff-Lipid- und Wirkstoff-Lipid-Cholesterin-haltigen kleinen unilamellaren Vesikeln nahe. Das Vorkommen von Bragg-Peaks im Streuprofil weist auf Domänen hin und systematische Untersuchungen zeigten, dass die Anzahl der Domänen mit steigendem Cholesteringehalt zunimmt, ab einem bestimmten Grenzwert jedoch wieder abnimmt. Die Domänen treten vor allem nahe der Außenfläche der Modellmembran auf und bestätigen, dass der Wirkstoff in den Cholesterinreichen Membranen vertikal eingelagert ist. Die Formulierung war sowohl Caco-2-Zellen als auch humanen roten Blutkörperchen gegenüber nicht toxisch und erwies sich unter Berücksichtigung der Aufnahme in Caco-2-Zellen als vielversprechend für die orale Applikation. Die Formulierung zeigt sich somit aussichtsreich und könnte in Tabletten weiterverarbeitet werden. Ein Filmüberzug würde den Wirkstoff gegen die saure Umgebung im Magen schützen. Für die Bestimmung der systemischen Verfügbarkeit der Formulierung sind Tierstudien notwendig. Die entwickelten multilamellaren Formulierungen einschließlich der Wirkstoff-Cholesterin-Komplexe bieten somit gute Aussichten auf die mögliche medizinische Anwendung. rnrn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper we examine the effect of contact angle (or surface wettability) on the convective heat transfer coefficient in microchannels. Slip flow, where the fluid velocity at the wall is non-zero, is most likely to occur in microchannels due to its dependence on shear rate or wall shear stress. We show analytically that for a constant pressure drop, the presence of slip increases the Nusselt number. In a microchannel heat exchanger we modified the surface wettability from a contact angle of 20 degrees-120 degrees using thin film coating technology. Apparent slip flow is implied from pressure and flow rate measurements with a departure from classical laminar friction coefficients above a critical shear rate of approximately 10,000 s(-1). The magnitude of this departure is dependant on the contact angle with higher contact angles surfaces exhibiting larger pressure drop decreases. Similarly, the non-dimensional heat flux is found to decrease relative to laminar non-slip theory, and this decrease is also a function of the contact angle. Depending on the contact angle and the wall shear rate, variations in the heat transfer rate exceeding 10% can be expected. Thus the contact angle is an important consideration in the design of micro, and even more so, nano heat exchangers. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We demonstrate the use of tilted fiber gratings to assist with the generation of infrared surface plasmons on a metal film coating the flat of a D-shaped fiber. The wavelength of the strong (>25 dB) resonance is tunable over similar to 1000 nm by adjusting the polarization state of the light and is highly sensitive to the refractive index of any aqueous medium surrounding the fiber (sensitivity= 3365 nm).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel method for tablet coating was studied where a thin polymer film was cast (pre-formed film), dried and applied as a coating hence eliminating the need for using any solvent during the actual coating process. A pre-formed film is initially heating to a temperature where it becomes flexible, a vacuum is applied and the film is then pulled around the tablet. The proposed films (gelatine or cellulose-based) were characterised in terms of their dissolution, swelling, mechanical and thermal properties prior to using them in the novel coating process; selected films were then coated onto tablets containing paracetamol or ibuprofen and the effect of the film on the subsequent dissolution was evaluated. It was found that the pre-formed films could be designed to be fast dissolving and mechanically strong to withstand the stress from the coating process. Also metoclopramide was incorporated in a gelatine film-coating formulation which was then successfully coated on paracetamol-containing core. Gelatin-based films were found to be successful in the novel coating process therefore to be suitable as finished coatings for immediate release dosage forms. Orally disintegrating dosage forms have been identified as a favourable dosage form due to the following reasons: fast onset of drug release, easy to use, not painful and possible increase of amount absorbed to systemic circulation. Selected films formulated for coating studies were also successfully formulated to contain active ingredient suitable for orally disintegrating dosage form; cellulose-based naratriptan-films were studied as orally disintegrating dosage forms of where the effect of formulation on the film properties was studied. It was found that strength of the film can affect the dissolution of the film but it may be the inclusion of specific excipients in the formulation which affect the penetration of the drug through mucosa.