914 resultados para Field of View.
Resumo:
An Internet survey demonstrated the existence of problems related to intraoperative tracking camera set-up and alignment. It is hypothesized that these problems are a result of the limited field of view of today's optoelectronic camera systems, which is usually insufficiently large to keep the entire site of surgical action in view during an intervention. A method is proposed to augment a camera's field of view by actively controlling camera orientation, enabling it to track instruments as they are used intraoperatively. In an experimental study, an increase of almost 300% was found in the effective volume in which instruments could be tracked.
Resumo:
PURPOSE. The driving environment is becoming increasingly complex, including both visual and auditory distractions within the in- vehicle and external driving environments. This study was designed to investigate the effect of visual and auditory distractions on a performance measure that has been shown to be related to driving safety, the useful field of view. METHODS. A laboratory study recorded the useful field of view in 28 young visually normal adults (mean 22.6 +/- 2.2 years). The useful field of view was measured in the presence and absence of visual distracters (of the same angular subtense as the target) and with three levels of auditory distraction (none, listening only, listening and responding). RESULTS. Central errors increased significantly (P < 0.05) in the presence of auditory but not visual distracters, while peripheral errors increased in the presence of both visual and auditory distracters. Peripheral errors increased with eccentricity and were greatest in the inferior region in the presence of distracters. CONCLUSIONS. Visual and auditory distracters reduce the extent of the useful field of view, and these effects are exacerbated in inferior and peripheral locations. This result has significant ramifications for road safety in an increasingly complex in-vehicle and driving environment.
Resumo:
The goal of my Ph.D. thesis is to enhance the visualization of the peripheral retina using wide-field optical coherence tomography (OCT) in a clinical setting.
OCT has gain widespread adoption in clinical ophthalmology due to its ability to visualize the diseases of the macula and central retina in three-dimensions, however, clinical OCT has a limited field-of-view of 300. There has been increasing interest to obtain high-resolution images outside of this narrow field-of-view, because three-dimensional imaging of the peripheral retina may prove to be important in the early detection of neurodegenerative diseases, such as Alzheimer's and dementia, and the monitoring of known ocular diseases, such as diabetic retinopathy, retinal vein occlusions, and choroid masses.
Before attempting to build a wide-field OCT system, we need to better understand the peripheral optics of the human eye. Shack-Hartmann wavefront sensors are commonly used tools for measuring the optical imperfections of the eye, but their acquisition speed is limited by their underlying camera hardware. The first aim of my thesis research is to create a fast method of ocular wavefront sensing such that we can measure the wavefront aberrations at numerous points across a wide visual field. In order to address aim one, we will develop a sparse Zernike reconstruction technique (SPARZER) that will enable Shack-Hartmann wavefront sensors to use as little as 1/10th of the data that would normally be required for an accurate wavefront reading. If less data needs to be acquired, then we can increase the speed at which wavefronts can be recorded.
For my second aim, we will create a sophisticated optical model that reproduces the measured aberrations of the human eye. If we know how the average eye's optics distort light, then we can engineer ophthalmic imaging systems that preemptively cancel inherent ocular aberrations. This invention will help the retinal imaging community to design systems that are capable of acquiring high resolution images across a wide visual field. The proposed model eye is also of interest to the field of vision science as it aids in the study of how anatomy affects visual performance in the peripheral retina.
Using the optical model from aim two, we will design and reduce to practice a clinical OCT system that is capable of imaging a large (800) field-of-view with enhanced visualization of the peripheral retina. A key aspect of this third and final aim is to make the imaging system compatible with standard clinical practices. To this end, we will incorporate sensorless adaptive optics in order to correct the inter- and intra- patient variability in ophthalmic aberrations. Sensorless adaptive optics will improve both the brightness (signal) and clarity (resolution) of features in the peripheral retina without affecting the size of the imaging system.
The proposed work should not only be a noteworthy contribution to the ophthalmic and engineering communities, but it should strengthen our existing collaborations with the Duke Eye Center by advancing their capability to diagnose pathologies of the peripheral retinal.
Resumo:
We present a high resolution spectrometer consisting of dual solid Fabry-Perot Interferometers (FPIs). This work is intended to be an all inclusive documentation of the instrument including discussion of the design of this instrument, the methods used in data reduction, and the analysis of these data. Each FPI is made of a single piece of L-BBH2 glass which has a high index of refraction n~2.07 with a thickness on the order of 100 μm. Each is then coated with partially reflective mirrors to create a resonant cavity and thus achieve a spectral resolution of R~30,000. Running the FPIs in tandem reduces the overlapping orders and allows for a much wider free spectral range and higher contrast. We will also discuss the properties of the FPIs which we have measured. This includes the tuning of the FPIs which is achieved by adjusting the temperature and thus changing the FPI gap and the refractive index of the material. The spectrometer then moves spatially in order to get spectral information at every point in the field of view. We select spectral lines for further analysis and create maps of the line depths across the field. Using this technique we are able to measure the fluorescence of chlorophyll in plants and attempt to observe zodiacal light. In the chlorophyll analysis we are able to detect chlorophyll fluorescence using the line depth in a plant using the sky as a reference solar spectrum. This instrument has possible applications in either a cubesat or aerial observations to measure bulk plant activity over large areas.
2D PIV measurements in the near field of grid turbulence using stitched fields from multiple cameras
Resumo:
We present measurements of grid turbulence using 2D particle image velocimetry taken immediately downstream from the grid at a Reynolds number of Re M = 16500 where M is the rod spacing. A long field of view of 14M x 4M in the down- and cross-stream directions was achieved by stitching multiple cameras together. Two uniform biplanar grids were selected to have the same M and pressure drop but different rod diameter D and crosssection. A large data set (10 4 vector fields) was obtained to ensure good convergence of second-order statistics. Estimations of the dissipation rate ε of turbulent kinetic energy (TKE) were found to be sensitive to the number of meansquared velocity gradient terms included and not whether the turbulence was assumed to adhere to isotropy or axisymmetry. The resolution dependency of different turbulence statistics was assessed with a procedure that does not rely on the dissipation scale η. The streamwise evolution of the TKE components and ε was found to collapse across grids when the rod diameter was included in the normalisation. We argue that this should be the case between all regular grids when the other relevant dimensionless quantities are matched and the flow has become homogeneous across the stream. Two-point space correlation functions at x/M = 1 show evidence of complex wake interactions which exhibit a strong Reynolds number dependence. However, these changes in initial conditions disappear indicating rapid cross-stream homogenisation. On the other hand, isotropy was, as expected, not found to be established by x/M = 12 for any case studied. © Springer-Verlag 2012.
Resumo:
The introduction of the Australian curriculum, the use of standardised testing (e.g. NAPLAN) and the My School website are couched in a context of accountability. This circumstance has stimulated and in some cases renewed a range of boundaries in Australian Education. The consequences that arise from standardised testing have accentuated the boundaries produced by social reproduction in education which has led to an increase in the numbers of students disengaging from mainstream education and applying for enrolment at the Edmund Rice Education Australia Flexible Learning Centre Network (EREAFLCN). Boundaries are created for many young people who are denied access to credentials and certification as a result of being excluded from or in some way disengaging from standardised education and testing. Young people who participate at the EREAFLCN arrive with a variety of forms of cultural capital that are not valued in current education and employment fields. This is not to say that these young people’s different forms of cultural capital have no value, but rather that such funds of knowledge, repertoires and cultural capital are not valued by the majority of powerful agents in educational and employment fields. How then can the qualitative value of traditionally unorthodox - yet often intricate, ingenious, and astute - versions of cultural capital evident in the habitus of many young people be made to count, be recognised, be valuated? Can a process of educational assessment be a field of capital exchange and a space which breaches boundaries through a valuating process? This paper reports on the development of an innovative approach to assessment in an alternative education institution designed for the re-engagement of ‘at risk’ youth who have left formal schooling. A case study approach has been used to document the engagement of six young people, with an educational approach described as assessment for learning as a field of exchange across two sites in the EREAFLCN. In order to capture the broad range of students’ cultural and social capital, an electronic portfolio system (EPS) is under trial. The model draws on categories from sociological models of capital and reconceptualises the eportfolio as a sociocultural zone of learning and development. Results from the trial show a general tendency towards engagement with the EPS and potential for the attainment of socially valued cultural capital in the form of school credentials. In this way restrictive boundaries can be breached and a more equitable outcome achieved for many young Australians.
Resumo:
This work studies the major sports overload injuries of the lower extremities from the biomechanical point of view. At the same time, the main paradigms of podiatric biomechanics and the application of new biomechanical theories in the study of these lesions are reviewed. With current legislation, clinical gait biomechanical studies should be carried out in health centres and the only health professionals who can perform them are podiatrists and doctors (because they both can diagnose). Graduates in physical education can carry out studies in the field or in the sports court for the sole purpose of improving athletic performance, but never intended to treat a pathology overload.
Resumo:
Based on the analysis model favored by the study of the conditions in which the seventeenth century Querelle des Anciens et des Modernes took place, we examine the case of confrontation between realism and abstraction, which occurred in the context of Spanish art in the nineties of the twentieth century. Connections are established with other aesthetic conflicts which are considered part of a genealogy whose most explicit antecedent could be placed in the before mentioned complaint, such as the confrontation between realism and abstraction in the American art scene, which occurred in the fifties of the last century, and the more recent controversy on pluralism and the end of art.
Resumo:
In this article, we present position indication functionality as obtained by using a retrodirective array, thereby allowing location information extraction of the position of the remote transmitter with which the retrodirective array is cooperating. This is carried out using straightforward circuitry with no requirement for complex angle of arrival algorithms, thereby giving a result in real time enabling tracking of fast moving transmitters. We show using a 10 x element retrodirective array, operating at 2.4 GHz that accuracies of far-field angle of arrival of within +/- 1 degrees over the arrays +/- 30 degrees azimuth field of view are possible. While in the near-field for angles of arrival of +/- 10 degrees it is possible to extract the position of a dipole source down to a resolution of 032 lambda. (C) 2010 Wiley Periodicals, Inc. Microwave Opt Technol Lett 52: 1031-1034, 2010; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.25097
Resumo:
The physiotherapist professional activities, in the beginning were focused only in the clinical field, nowadays it has many different action fields including Physical Activity. Physical activity can be viewed from two dimensions: one biological, which is defined as any activity which requires energy expenditure involving the combined action of multiple systems; on the other side social, understood as a human activity concerning subjectivity conditions influenced by the environment where the individual and the community are developed. Given these dimensions as well as national and international benchmarks this paper’s objective is to present a series of reflections that the authors have done regarding the physiotherapist professional performance in the field of physical activity and the large possibilities derived from their practice in this field.