983 resultados para Femoral Fractures, Internal Fixation Device, Internal Fracture Fixation, LegIinjury


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To preliminarily evaluate prospectively the accuracy and reliability of a specific ad hoc reduction-compression forceps in intraoral open reduction of transverse and displaced mandibular angle fractures. STUDY DESIGN: We analyzed the clinical and radiologic data of 7 patients with 7 single transverse and displaced angle fractures. An intraoral approach was performed in all of the patients without using perioperative intermaxillary fixation. A single Arbeitsgemeinschaft Osteosynthese (AO) unilock reconstruction plate was fixed to each stable fragment with 3 locking screws (2.0 mm in 5 patients and 2.4 mm in 2 patients) at the basilar border of the mandible, according to AO/American Society of Internal Fixation (ASIF) principles. Follow-up was at 1, 3, 6, and 12 months, and we noted the status of healing and complications, if any. RESULTS: All of the patients had satisfactory fracture reduction as well as a successful treatment outcome without complications. CONCLUSION: This preliminary study demonstrated that the intraoral reduction of transverse and displaced angle fractures using a specific ad hoc reduction-forceps results in a high rate of success.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proximal femoral extracapsular fractures have shown a significantly high morbidity and mortality rate at 1 year in cases of nonoperative treatment. The standard gamma nail was originally designed to provide stable fixation and allow early mobilization and weight bearing for elderly patients. The design of the standard gamma nail, however, appears to be associated with intraoperative or postoperative femoral shaft fractures in < or = 17% of patients, compromising the outcome. The trochanteric nail was developed to overcome the problems encountered with the use of the standard gamma nail. Between July 2000 and January 2001, 88 consecutive proximal femoral extracapsular fractures were treated with a trochanteric nail, Seventy-five patients (76 fractures) were observed clinically and radiographically for 2 years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eighteen patients with acetabular fractures, with a mean age of 76 years, were treated with cable fixation and acute total hip arthroplasty. Nine were T-shaped fractures, 4 associated transverse and posterior wall, 2 transverse, 2 posterior column and posterior wall, and 1 anterior and posterior hemitransverse fractures. One patient experienced 3 episodes of hip dislocation within 10 months after surgery. All the others had a good outcome at a mean follow-up time of 36 months. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This option provides good primary fixation, stabilizes complex acetabular fractures in elderly patients, and permits early postoperative mobilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Femoral neck fracture without associated trauma following consolidation of a transtrochanteric fracture is a rare event. The authors report a case of transtrochanteric fracture that was treated with PFN and which presented fracturing of the femoral neck two weeks after removal of the device. This occurrence was treated with partial arthroplasty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The purpose of our study was to retrospectively evaluate the clinical and radiological results of subtrochanteric fractures treated with a long gamma nail (LGN). The LGN has been the implant of choice at our level-1 trauma center since 1992. MATERIALS AND METHODS: Over a period of 7 years, we have treated 90 consecutive patients with subtrochanteric fractures. In order to evaluate the clinical and radiological outcomes, we reviewed the clinical and radiographic charts of these patients followed for a mean time of 2 years (range 13-36 months). RESULTS: We found no intra- or perioperative complications nor early or late infection. Clinical and radiological union was achieved at a mean of 4.3 months in all of the patients (range 3-9 months); in 24 cases (30%) the distal locking bolts were retrieved in order to enhance callus formation and remodeling as a planned secondary surgery. Three patients (3.3%) needed unplanned secondary surgery for problems related to the nailing technique. Two mechanical failures with breakage of the nail were encountered due to proximal varus malalignment, of which one was treated with exchange nailing and grafting and the other one by removal of the broken hardware, blade-plating, and bone grafting. One fracture below a short LGN was treated by exchange nailing. CONCLUSIONS: The minimally invasive technique and simple application of the LGN lead to a low percentage of complications in these difficult fractures after a relatively short learning curve. The biomechanical properties of this implant allow early mobilization and partial weight-bearing even in patients with advanced osteoporosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osteoporosis is an increasing public health problem. The bisphophonates are the most useful treatment used through the world to prevent osteoporotic fractures. Their large prescription revealed an unpredictable side effect: the atypical fracture. These fractures appear in the subtrochanteric or diaphysal femoral proximal site, spontaneously or after a low trauma, and could be bilateral. X-rays shows a transversal or oblique fracture with a spur in the cortex and with a diffuse thickening of the cortical of the proximal femur. Expert's recommendations are current in progress to well understand and managed this problem. Here we report three cases of atypical femur fractures occurred in our Centre of bone diseases with some management and treatment propositions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

5 to 10% of all fractures present with a delayed union, whereas 1 to 5% progress to a nonunion, which can be defined as a fracture older than 6 months and lacks any potential to heal without any further intervention. Different fracture and patient related risk factors exist, and the management of a nonunion needs a thorough clinical, radiological and biological workup to classify them in one of the two main categories, the viable nonunions that need essentially more stability, usually by a more rigid fixation, and the non-viable nonunions that need essentially a biological stimulation by decortication and bone grafting. This treatment still remains the first choice with bony healing obtained in 85 to 95% of cases, but it also comes along with certain risks, and some valuable alternatives exist if chosen on the basis of rigid criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The femoral periprosthetic fracture of the knee is one of the most feared complications because of its repercussions. Incidence are more and more likely due to the increase of total implanted arthroplasty of the knee, due to the increasing lifespan among the general population. The objective of this study is to analyze some of the perioperative aspects of the treatment of these fractures, comparing the use of osteosynthesis with plates and the retrograde nailing in those patients with femoral periprosthetic knee fractures with a stable implant. MATERIAL AND METODS: The study retrospectively examines 18 cases treated consecutively in our hospital (3 men and 15 women, average age of 72.7 years) between the years of 2000 and 2009. All fractures were located in the distal femur and on a stable implant. Eight were treated through retrograde nailing (Group I) and ten with plates (Group II). The cases are analyzed through the tests of the University of Mann-Withney and the exact Fischer test, with significant values of p≤0.05, the variables of median hospital stay, necessity of transfusion indicated with values of hemoglobin less than 8 mg/ml, preoperative radiological alignment and postoperative alignment of the total knee prosthesis (TKR), measured following the anatomical tibiofemoral axis, time of consolidation and incidence of localized complications in both groups. RESULTS: We did not find any statistically significant differences between the two groups in any of the variables analyzed. Localized complications are more frequent in Group I (62.5 percent of patients) than in Group II (10 percent of patients). The need for transfusion is greater in Group II (40 percent) than in Group I (12.5 percent). CONCLUSIONS: The type of implant used in treatment of femoral periprosthetic knee fracture does not significantly influence perioperative factors. The treatment for this type of fractures should be individually chosen in relation to the type of fracture, characteristics of the patient and stability and prosthesis model of the primary knee.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe the use of cable fixation and acute total hip replacement for acetabular fracture in the elderly. 12 patients with acetabular fractures, having a mean age of 79 (65-93) years, were treated with cable fixation and acute total hip arthroplasty. 8 were T-shaped fractures and 4 associated fractures of the posterior column and posterior wall. 1 patient died 5 months after surgery and the remaining 11 were followed for 2 years. All patients had a good clinical outcome. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This surgical technique provides good primary fixation, stabilizes complex acetabular fractures in elderly patients with osteoporotic bone and permits early postoperative mobilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

5 to 10% of all fractures present with a delayed union, whereas 1 to 5% progress to a nonunion, which can be defined as a fracture older than 6 months and lacks any potential to heal without any further intervention. Different fracture and patient related risk factors exist, and the management of a nonunion needs a thorough clinical, radiological and biological workup to classify them in one of the two main categories, the viable nonunions that need essentially more stability, usually by a more rigid fixation, and the non-viable nonunions that need essentially a biological stimulation by decortication and bone grafting. This treatment still remains the first choice with bony healing obtained in 85 to 95% of cases, but it also comes along with certain risks, and some valuable alternatives exist if chosen on the basis of rigid criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Between January 1996 and July 2003, 93 consecutive patients operated on with a diagnosis of olecranon fractures were identified from our trauma unit files. Fourteen transolecranon fracture-dislocations were found after a retrospective X-radiographic evaluation. Eight patients were women and six were men, with a mean age of 54 years. There were 4 noncomminuted olecranon fractures, treated with K-wires and single tension-band wiring. The remaining 10 fractures were complex fractures, treated in 3 cases with multiple K-wires and single tension-band wiring, in 2 by use of one-third tubular plates, in 1 with a 3.5-mm dynamic compression plate, and in the remaining 4 with 3.5-mm reconstruction plates. Ligament repair was not performed in any case. Three patients needed reoperation because of early failure of primary fixation. Patients were reviewed at a mean follow-up of 3.6 years. Two reported difficulties in daily activities, none with any symptoms of elbow instability. According to the Broberg and Morrey score, 4 patients had excellent results, 6 had good results, 2 had fair results, and 2 had poor results. Four patients showed signs of degenerative arthritis on the radiographs obtained at follow-up. We conclude that transolecranon fracture-dislocation is an underreported and misdiagnosed injury. Various fixation techniques can restore the anatomic relationships and contour of the trochlear notch; the imperative goal is to obtain a good stable primary fixation and allow early active mobilization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This prospective study addresses early results of the treatment of acute acetabular fractures in elderly patients by total hip arthroplasty and cerclage wiring.Fifteen patients with an average age of 81 years were treated at our institution between February 1998 and December 2000. There were two transverse fractures, eight T-shaped fractures, two transverse fractures with associated posterior wall fracture, two posterior column fractures with associated posterior wall fracture, and one fracture of both columns. Treatment consisted of cerclage wiring of the fracture and primary non-cemented total hip replacement.All of the patients were followed for a mean of 36 months. Although there was one patient with three hip dislocations during the first 10 months after the operation, we found an excellent or good result for the entire group. During this relatively short follow-up period, we have not found a radiological loss of fracture reduction of more than 1 mm or a cup migration of more than 3.2 mm. All of the fractures healed and no loosening of the implant was evident.Primary total hip arthroplasty combined with internal fixation is a valid treatment option for acetabular fractures in the elderly. Preliminary results are convincing, but a bigger patient population and a longer follow-up time are necessary before we are able to draw final conclusions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: La fractura de cadera se presenta predominantemente en población mayor; se espera que para el año 2050 se presenten alrededor de 6 millones de fracturas de cadera a nivel global. Parkkari et al (1). Dado que el sistema de salud colombiano dificulta el seguimiento adecuado de los pacientes y su manejo posoperatorio integral, desconocen las estadísticas reales de los desenlaces funcionales, mortalidad y complicaciones asociadas a la fractura de cadera. Método: Estudio observacional descriptivo de corte transversal. Mediante una encuesta telefónica cuyo objetivo fue determinar el manejo intra y extra hospitalario por los servicios de rehabilitación y ortopedia, describir la mortalidad y la recuperación funcional percibidos por los encuestados. Resultados: De 286 pacientes intervenidos, 116 aceptaron participar (24% hombres y 76% mujeres). Edades entre 65 y 99 años (media: 81.3 años). En el primer año después de la cirugía, el 29% de los pacientes presento al menos un reingreso hospitalario; la mortalidad en el grupo femenino fue de 23% frente a un 43% en el grupo masculino. El 98% de los pacientes deambulaba previo a la cirugía, frente a un 78% de los pacientes a un año del procedimiento, 83 pacientes refirieron complicaciones pos-operatorias. En el grupo entre 65 y 74 años la capacidad de deambular posterior al procedimiento fue de 84%, para las edades entre 75 a 84 años fue del 82% y en los mayores de 85 años del 75%. Conclusiones: La recuperación funcional de los pacientes intervenidos por fractura de cadera, difícilmente llegan a alcanzar el estado funcional previo a la fractura, lo cual se traduce en situaciones de dependencia, riesgo de caída y complicaciones médicas.