911 resultados para Fabry–Perot cavities


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The maximum stress concentration factor in brittle materials with a high concentration of cavities is obtained. The interaction between the nearest cavities, in addition to the far field interactions, is taken into account to evaluate the strength distribution based on the statistical analysis of the nearest distance distribution. Through this investigation, it is found that the interaction between the nearest neighbors is much more important than the far field interactions, and one has to consider it in calculating the strength of brittle materials even if the volume fraction of cavities it contains is small. The other important conclusion is that the maximum stress concentration factor has a wide scattered distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resonant cavity modes in a torus with elliptical cross section are studied by means of a direct variational method. The nonlinear effects of toroidicity and ellipticity on the frequency of the basic mode are analyzed simply and systematically without the restriction of linear theory. It is shown that the toroidicity effect on the m = 0 transverse magnetic mode is less-than-or-equal-to 11%. The frequency of the mode shifts approximately 11-29% when the elongation of the cross section changes from 1 to 2. The effects of toroidicity and ellipticity differ for each resonant mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we first present a system of differential-integral equations for the largedisturbance to the general case that any arbitrarily shaped solid body with a cavity contain-ing viscous liquid rotates uniformly around the principal axis of inertia, and then develop aweakly non-linear stability theory by the Lyapunov direct approach. Applying this theoryto the Columbus problem, we have proved the consistency between the theory and Kelvin'sexperiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanisms of shock focusing in inner cavities of double wedge and cone are compared with that of traditional curved-surface shock focusing. The results show that there are many high temperature regions just behind shock surface which appear in two place alternately, one is near the surface of wall and the other is near the centerline. Also, changes in temperature, pressure, energy and power of the high temperature regions were analyzed and the results show that energy and power per unit volume increase, but total energy and power in the high temperature regions decrease during the process of shock moving forward the apex of double wedge or cone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated four unique methods for achieving scalable, deterministic integration of quantum emitters into ultra-high Q{V photonic crystal cavities, including selective area heteroepitaxy, engineered photoemission from silicon nanostructures, wafer bonding and dimensional reduction of III-V quantum wells, and cavity-enhanced optical trapping. In these areas, we were able to demonstrate site-selective heteroepitaxy, size-tunable photoluminescence from silicon nanostructures, Purcell modification of QW emission spectra, and limits of cavity-enhanced optical trapping designs which exceed any reports in the literature and suggest the feasibility of capturing- and detecting nanostructures with dimensions below 10 nm. In addition to process scalability and the requirement for achieving accurate spectral- and spatial overlap between the emitter and cavity, these techniques paid specific attention to the ability to separate the cavity and emitter material systems in order to allow optimal selection of these independently, and eventually enable monolithic integration with other photonic and electronic circuitry.

We also developed an analytic photonic crystal design process yielding optimized cavity tapers with minimal computational effort, and reported on a general cavity modification which exhibits improved fabrication tolerance by relying exclusively on positional- rather than dimensional tapering. We compared several experimental coupling techniques for device characterization. Significant efforts were devoted to optimizing cavity fabrication, including the use of atomic layer deposition to improve surface quality, exploration into factors affecting the design fracturing, and automated analysis of SEM images. Using optimized fabrication procedures, we experimentally demonstrated 1D photonic crystal nanobeam cavities exhibiting the highest Q/V reported on substrate. Finally, we analyzed the bistable behavior of the devices to quantify the nonlinear optical response of our cavities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermodynamical fluctuations in temperature and position exist in every physical system, and show up as a fundamental noise limit whenever we choose to measure some quantity in a laboratory environment. Thermodynamical fluctuations in the position of the atoms in the dielectric coatings on the mirrors for optical cavities at the forefront of precision metrology (e.g., LIGO, the cavities which probe atomic transitions to define the second) are a current limiting noise source for these experiments, and anything which involves locking a laser to an optical cavity. These thermodynamic noise sources scale physical geometry of experiment, material properties (such as mechanical loss in our dielectric coatings), and temperature. The temperature scaling provides a natural motivation to move to lower temperatures, with a potential huge benefit for redesigning a room temperature experiment which is limited by thermal noise for cryogenic operation.

We design, build, and characterize a pair of linear Fabry-Perot cavities to explore limitations to ultra low noise laser stabilization experiments at cryogenic temperatures. We use silicon as the primary material for the cavity and mirrors, due to a zero crossing in its linear coefficient of thermal expansion (CTE) at 123 K, and other desirable material properties. We use silica tantala coatings, which are currently the best for making high finesse low noise cavities at room temperature. The material properties of these coating materials (which set the thermal noise levels) are relatively unknown at cryogenic temperatures, which motivates us to study them at these temperatures. We were not able to measure any thermal noise source with our experiment due to excess noise. In this work we analyze the design and performance of the cavities, and recommend a design shift from mid length cavities to short cavities in order to facilitate a direct measurement of cryogenic coating noise.

In addition, we measure the cavities (frequency dependent) photo-thermal response. This can help characterize thermooptic noise in the coatings, which is poorly understood at cryogenic temperatures. We also explore the feasibility of using the cavity to do macroscopic quantum optomechanics such as ground state cooling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In many micro- and nano-scale technological applications high sensitivity displacement sensors are needed, especially in ultraprecision metrology and manufacturing. In this work a new way of sensing displacement based on radio frequency resonant cavities is presented and experimentally demonstrated using a first laboratory prototype. The principle of operation of the new transducer is summarized and tested. Furthermore, an electronic interface that can be used together with the displacement transducer is designed and proved. It has been experimentally demonstrated that very high and linear sensitivity characteristic curves, in the range of some kHz/nm; are easily obtainable using this kind of transducer when it is combined with a laboratory network analyzer. In order to replace a network analyzer and provide a more affordable, self-contained, compact solution, an electronic interface has been designed, preserving as much as possible the excellent performance of the transducer, and turning it into a true standalone positioning sensor. The results obtained using the transducer together with a first prototype of the electronic interface built with cheap discrete elements show that positioning accuracies in the micrometer range are obtainable using this cost-effective solution. Better accuracies would also be attainable but using more involved and costly electronics interfaces.