121 resultados para FIBEROPTIC BRONCHOSCOPY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Lung cancer (LC) is the leading cause of cancer death in the developed world. Most cancers are associated with tobacco smoking. A primary hope for reducing lung cancer has been prevention of smoking and successful smoking cessation programs. To date, these programs have not been as successful as anticipated. Objective: The aim of the current study was to evaluate whether lung cancer screening combining low dose computed tomography with autofluorescence bronchoscopy (combined CT & AFB) is superior to CT or AFB screening alone in improving lung cancer specific survival. In addition, the extent of improvement and ideal conditions for combined CT & AFB screening were evaluated. Methods: We applied decision analysis and Monte Carlo simulation modeling using TreeAge Software to evaluate our study aims. Histology- and stage specific probabilities of lung cancer 5-year survival proportions were taken from Surveillance and Epidemiologic End Results (SEER) Registry data. Screeningassociated data was taken from the US NCI Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial (PLCO), National Lung Screening Trial (NLST), and US NCI Lung Screening Study (LSS), other relevant published data and expert opinion. Results: Decision Analysis - Combined CT and AFB was the best approach at Improving 5-year survival (Overall Expected Survival (OES) in the entire screened population was 0.9863) and in lung cancer patients only (Lung Cancer Specific Expected Survival (LOSES) was 0.3256). Combined screening was slightly better than CT screening alone (OES = 0.9859; LCSES = 0.2966), and substantially better than AFB screening alone (OES = 0.9842; LCSES = 0.2124), which was considerably better than no screening (OES = 0.9829; LCSES = 0.1445). Monte Carlo simulation modeling revealed that expected survival in the screened population and lung cancer patients is highest when screened using CT and combined CT and AFB. CT alone and combined screening was substantially better than AFB screening alone or no screening. For LCSES, combined CT and AFB screening is significantly better than CT alone (0.3126 vs. 0.2938, p< 0.0001). Conclusions: Overall, these analyses suggest that combined CT and AFB is slightly better than CT alone at improving lung cancer survival, and both approaches are substantially better than AFB screening alone or no screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The use of Er:YAG laser operating in the 3 μm range with adjustable power and pulses has become popular for dental and medical practice due to its high photoablative capacity, surgical precision and antimicrobial action. Background data: The existing fiberoptic tips irradiate lasers parallel to the long axes of the tooth limiting its efficiency in the root canal. Methods: We evaluated hollow fiberoptic tips obtained from silicate glass as a means of Er:YAG laser conduction in dental procedures. The fiber tips were molded from capillary tubes with different profiles so that their ends would have cylindric, conical or spherical shapes. The performance of the three fibers as a means of propagation of Er:YAG (λ = 2.94 μm) laser radiation was compared to that of a solid sapphire fiber at 10 Hz and 200 mJ and of 20 Hz and 500 mJ. The profiles of frontal and lateral burning were visualized on thermal paper. Results: Analysis of these profiles demonstrated that the sapphire tip and the hollow fiber of cylindric section did not differ significantly in the profiles of frontal burning, and no lateral burning was detected. The fibers of the conical and spherical sections, although presenting attenuation in the frontal output power, showed a larger burning area in the frontal profile, in addition to producing lateral burning. Conclusions: The results indicate that commercial hollow fiberoptics have advantages such as easy manufacture of the different tip shapes, great adaptability, low cost, and a low loss of transmission. © Mary Ann Liebert, Inc.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous dilatational tracheostomy (PDT) is a frequently conducted procedure in critically ill patients. Bronchoscopic guidance of PDT is generally recommended to minimize the risk of unintentional tracheal injury. We present a case of tracheal tear and tension pneumothorax, a rare but potentially life-threatening complication, during continuously bronchoscopy-guided PDT. Sealing the large tracheal air fistula with the cuff of an endotracheal tube helped bridge time to definitive surgical repair in our patient. Bronchoscopic guidance may minimize, but cannot completely eliminate, the risk of tracheal injury during PDT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calcium influx into the dendritic tufts of layer 5 neocortical pyramidal neurons modifies a number of important cellular mechanisms. It can trigger local synaptic plasticity and switch the firing properties from regular to burst firing. Due to methodological limitations, our knowledge about Ca2+ spikes in the dendritic tuft stems mostly from in vitro experiments. However, it has been speculated that regenerative Ca2+ events in the distal dendrites correlate with distinct behavioral states. Therefore it would be most desirable to be able to record these Ca2+ events in vivo, preferably in the behaving animal. Here, we present a novel approach for recording Ca2+ signals in the dendrites of populations of layer 5 pyramidal neurons in vivo, which ensures that all recorded fluorescence changes are due to intracellular Ca2+ signals in the apical dendrites. The method has two main features: 1) bolus loading of layer 5 with a membrane-permeant Ca2+ dye resulting in specific loading of pyramidal cell dendrites in the upper layers and 2) a fiberoptic cable attached to a gradient index lens and a prism reflecting light horizontally at 90 degrees to the angle of the apical dendrites. We demonstrate that the in vivo signal-to-noise ratio recorded with this relatively inexpensive and easy-to-implement fiberoptic-based device is comparable to conventional camera-based imaging systems used in vitro. In addition, the device is flexible and lightweight and can be used for recording Ca2+ signals in the distal dendritic tuft of freely behaving animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the development of an open-source system for virtual bronchoscopy used in combination with electromagnetic instrument tracking. The end application is virtual navigation of the lung for biopsy of early stage cancer nodules. The open-source platform 3D Slicer was used for creating freely available algorithms for virtual bronchscopy. Firstly, the development of an open-source semi-automatic algorithm for prediction of solitary pulmonary nodule malignancy is presented. This approach may help the physician decide whether to proceed with biopsy of the nodule. The user-selected nodule is segmented in order to extract radiological characteristics (i.e., size, location, edge smoothness, calcification presence, cavity wall thickness) which are combined with patient information to calculate likelihood of malignancy. The overall accuracy of the algorithm is shown to be high compared to independent experts' assessment of malignancy. The algorithm is also compared with two different predictors, and our approach is shown to provide the best overall prediction accuracy. The development of an airway segmentation algorithm which extracts the airway tree from surrounding structures on chest Computed Tomography (CT) images is then described. This represents the first fundamental step toward the creation of a virtual bronchoscopy system. Clinical and ex-vivo images are used to evaluate performance of the algorithm. Different CT scan parameters are investigated and parameters for successful airway segmentation are optimized. Slice thickness is the most affecting parameter, while variation of reconstruction kernel and radiation dose is shown to be less critical. Airway segmentation is used to create a 3D rendered model of the airway tree for virtual navigation. Finally, the first open-source virtual bronchoscopy system was combined with electromagnetic tracking of the bronchoscope for the development of a GPS-like system for navigating within the lungs. Tools for pre-procedural planning and for helping with navigation are provided. Registration between the lungs of the patient and the virtually reconstructed airway tree is achieved using a landmark-based approach. In an attempt to reduce difficulties with registration errors, we also implemented a landmark-free registration method based on a balanced airway survey. In-vitro and in-vivo testing showed good accuracy for this registration approach. The centreline of the 3D airway model is extracted and used to compensate for possible registration errors. Tools are provided to select a target for biopsy on the patient CT image, and pathways from the trachea towards the selected targets are automatically created. The pathways guide the physician during navigation, while distance to target information is updated in real-time and presented to the user. During navigation, video from the bronchoscope is streamed and presented to the physician next to the 3D rendered image. The electromagnetic tracking is implemented with 5 DOF sensing that does not provide roll rotation information. An intensity-based image registration approach is implemented to rotate the virtual image according to the bronchoscope's rotations. The virtual bronchoscopy system is shown to be easy to use and accurate in replicating the clinical setting, as demonstrated in the pre-clinical environment of a breathing lung method. Animal studies were performed to evaluate the overall system performance.