799 resultados para Evaluation as an immunogen


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Learning computer programming requires solving programming exercises. In computer programming courses teachers need to assess and give feedback to a large number of exercises. These tasks are time consuming and error-prone since there are many aspects relating to good programming that should be considered. In this context automatic assessment tools can play an important role helping teachers in grading tasks as well to assist students with automatic feedback. In spite of its usefulness, these tools lack integration mechanisms with other eLearning systems such as Learning Management Systems, Learning Objects Repositories or Integrated Development Environments. In this paper we provide a survey on programming evaluation systems. The survey gathers information on interoperability features of these systems, categorizing and comparing them regarding content and communication standardization. This work may prove useful to instructors and computer science educators when they have to choose an assessment system to be integrated in their e-Learning environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes the standardization and evaluation of an in-house specific IgG avidity ELISA for distinguishing recent primary from long-term human cytomegalovirus (HCMV) infection. The test was standardized with the commercial kit ETI-CYTOK G Plus (Sorin Biomedica, Italy) using 8 M urea in phosphate-buffered saline to dissociate low-avidity antibodies after the antigen-antibody interaction. The performance of the in-house assay was compared to that of the commercial automated VIDAS CMV IgG avidity test (bioMérieux, France). Forty-nine sera, 24 from patients with a recent primary HCMV infection and 25 from patients with a long-term HCMV infection and a sustained persistence of specific IgM antibodies, were tested. Similar results were obtained with the two avidity methods. All 24 sera from patients with recently acquired infection had avidity indices compatible with acute HCMV infection by the VIDAS method, whereas with the in-house method, one serum sample had an equivocal result. In the 25 sera from patients with long-term infection, identical results were obtained with the two methods, with only one serum sample having an incompatible value. These findings suggest that our in-house avidity test could be a potentially useful tool for the immunodiagnosis of HCMV infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Porokeratosis ptychotropica is a rare variant of porokeratosis that is classically located on the gluteal and perianal regions, seldom extending to the genitalia. The authors report an atypical presentation of porokeratosis ptychotropica and discuss the use of dermoscopy in evaluating this dermatosis. Dermoscopic findings, although not specific to this variant of porokeratosis, are helpful in the differential diagnosis of other genital disorders. Histopathology, through the visualization of multiple cornoid lamellae, prevails as the gold standard for the definite diagnosis of porokeratosis ptychotropica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate the second-generation OptiMal test for malaria diagnosis under various storage conditions. It detected all the positive samples, except for two Plasmodium malariae samples. Further research evaluating diverse environmental conditions are important for ICT test applicability in Brazilian malaria areas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Neurocysticercosis is an infection of the human central nervous system caused by the metacestode larvae of Taenia solium. Neurocysticercosis is the most common parasitic disease in developing countries. Epilepsy is the most common clinical manifestation. Difficulties in confirming the diagnosis motivated the evaluation of the enzyme-linked immunosorbent assay on cerebral spinal fluid (CSF). METHODS: Twenty-two patients with NCC and 44 control patients were studied. CSF was analyzed using a commercial ELISA kit developed for NCC. Sensitivity and specificity were measured and a multivariate logistic regression was performed. RESULTS: Sensitivity and specificity of ELISA were 31.8% and 100%, respectively, with accuracy of 77.3%. Only the size of the lesions proved to be important for performance of the test. CONCLUSIONS: The results showed that ELISA contributes to the diagnosis of neurocysticercosis if the result is negative or if the patient has a lesion of 2 cm or more.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In 1989, we introduced a 1-stage procedure with orthotopic colonic transplants for esophageal stenosis. A pitfall of this procedure is frequent reflux and/or stasis in the transplants from the cologastric anastomosis. Since 1993, we have used a new antireflux wrap (ARW) using an anterior wrap technique similar to the Dor procedure but fixed to the right crus of the diaphragm.Purpose: The purpose of the study was to evaluate ARWs.Method: From 1993 to 2008, the records of 67 patients with an ARW were compared with 27 without ARW (either operated on before 1993 or ARW was not appropriate) after colonic transplant for caustic esophageal stenosis. Both groups otherwise underwent the same surgical procedure. Postoperative esophagograms done on postoperative day 10 were reviewed for the presence of gastrocolonic reflux and stasis in the transplant.Results: The reflux rate on the initial esophagogram was reduced from 48.1% to 7.5% using ARW. The incidence of reflux on later esophagograms was 40.0% with no ARW and 21.4% with ARW. The 25% long-term rate of stasis in the colonic transplant was not increased with ARW.Conclusions: A loose ARW in patients with colonic esophageal replacements reduces gastrocolic reflux without increasing the rate of stasis. In the long term, children adapt better to stasis than to reflux and are thus protected from occult inflammation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bovine babesiosis is endemic in Venezuela, causing significant losses in highly susceptible imported cattle. Current immunoprphylatic methods include the less desirable use of live parasites. Inactivated vaccines derived from exoantigen-containing supernatant fluids of in vitro Babesia bovis and B. bigemina cultures have been developed and constitute a major improvement in vaccine safety, stability and ease of handling. Vaccination trials conducted under field conditions provide the final evaluation of a culture-derived B. bovis-B. bigemina vaccine. During a 5-year period, approximately 8,000 cattle were vaccinated and 16 clinical trials carried out in. 7 states of Venezuela Clinical, serologic and parasitologic data were collected monthly from 10% of the animals over a 2-year period. Data were also collected from a similar number of nonvaccinated control cattle. Analysis of results from these trials demonstrated a reduction in the incidence of clinical disease among vaccinated animals and complete protection against mortality among vaccinated and nonvaccinated cattle. Use of this inactivated vaccine offers the best combination od safety, potency and efficacy for thew immunoprophylatic control of bovine babesiosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Immunoglobulin G and M humoral response to recombinant protein B13 and glycoconjugate LPPG Trypanosoma cruzi defined antigens was evaluated by ELISA in 18 patients in the acute phase of Chagas disease, who were contaminated on the same occasion. LPPG showed 100% positivity detecting both IgM and IgG antibodies, while positivity of 55-65% was observed for B13. An epimastigote alkaline extract (EPI) also showed high sensitivity for acute IgM (100%) and IgG (90%) antibodies. However LPPG had better discriminatory reactivity since with EPI two patients showed negative IgG and several other sera presented OD values for IgG and IgM antibodies very close to the cutoff. Thus, it is suggested that detection of IgM antibodies by LPPG may be used for diagnosis of the acute phase of Chagas disease. An intense decline of IgG and IgM antibodies to the three antigens was observed in response to anti-T. cruzi chemotherapy in all acute phase patients. After treatment, six (30%) individuals maintained IgG positivity to EPI, LPPG, and B13 with lower reactivity than that measured at the acute phase. For comparison, serology of a group of 22 patients in the chronic phase of Chagas disease and also submitted to chemotherapy was determined. Positive IgM antibodies to EPI, LPPG and B13 were detected in only 5-9% cases. In all chronic-phase patients IgG antibodies highly reactive to the three antigens were present and no significant decrease resulted after benznidazole administration. These observations reinforce previous reports that treatment in the acute phase may reduce or eliminate the parasite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was undertaken to evaluate an enzyme immunoassay (EIA) for hepatitis C virus antibody detection (anti-HCV), using just one antigen. Anti-HCV EIA was designed to detect anti-HCV IgG using on the solid-phase a recombinant C22 antigen localized at the N-terminal end of the core region of HCV genome, produced by BioMérieux. The serum samples diluted in phosphate buffer saline were added to wells coated with the C22, and incubated. After washings, the wells were loaded with conjugated anti-IgG, and read in a microtiter plate reader (492 nm). Serum samples of 145 patients were divided in two groups: a control group of 39 patients with non-C hepatitis (10 acute hepatitis A, 10 acute hepatitis B, 9 chronic hepatitis B, and 10 autoimmune hepatitis) and a study group consisting of 106 patients with chronic HCV hepatitis. In the study group all patients had anti-HCV detected by a commercially available EIA (Abbott®), specific for HCV structural and nonstructural polypeptides, alanine aminotransferase elevation or positive serum HCV-RNA detected by nested-PCR. They also had a liver biopsy compatible with chronic hepatitis. The test was positive in 101 of the 106 (95%) sera from patients in the study group and negative in 38 of the 39 (97%) sera from those in the control group, showing an accuracy of 96%. According to these results, our EIA could be used to detect anti-HCV in the serum of patients infected with hepatitis C virus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With some 30,000 dependent persons, opiate addiction constitutes a major public health problem in Switzerland. The Swiss Federal Office of Public Health (FOPH) has long played a leading role in the prevention and treatment of opiate addiction and in research on effective means of containing the epidemic of opiate addiction and its consequences. Major milestones on that path have been the successive "Methadone reports" published by that Office and providing guidance on the care of opiate addiction with substitution treatment. In view of updating the recommendations for the appropriateness of substitution treatment for opiate addiction, in particular for the prescription of methadone, the FOPH commissioned a multi-component project involving the following elements. A survey of current attitudes and practices in Switzerland related to opiate substitution treatment Review of Swiss literature on methadone substitution treatment Review of international literature on methadone substitution treatment National Methadone Substitution Conference Multidisciplinary expert panel to evaluate the appropriateness of substitution treatment. The present report documents the process and summarises the results of the latter element above. The RAND appropriateness method (RAM) was used to distil from literature-based evidence and systematically formulated expert opinion, areas where consensus exist on the appropriateness (or inappropriateness) of methadone maintenance treatment (MMT) and areas where disagreement or uncertainty persist and which should be further pursued. The major areas which were addressed by this report are Initial assessment of candidates for MMT Appropriate settings for initiation of MMT (general and special cases) Appropriateness of methadone supportive therapy Co-treatments and accompanying measures Dosage schedules and pharmacokinetic testing Withdrawal from MMT Miscellaneous questions Appropriateness of other (non-methadone) substitution treatment Summary statements for each of the above categories are derived from the panel meeting and presented in the report. In the "first round", agreement was observed for 31% of the 553 theoretical scenarios evaluated. The "second round" rating, following discussion of divergent ratings, resulted in a much higher agreement among panellists, reaching 53% of the 537 scenarios. Frank disagreement was encountered for 7% of all scenarios. Overall 49% of the clinical situations (scenarios) presented were considered appropriate. The areas where at least 50% of the situations were considered appropriate were "initial assessment of candidates for MMT", the "appropriate settings for initiation of MMT", the "appropriate settings for methadone supportive treatment" and "Appropriateness of other (non-methadone) substitution treatment". The area where there was the least consensus on appropriateness concerned "appropriateness of withdrawal from MMT" (6%). The report discusses the implications and limitations of the panel results and provides recommendations for the dissemination, application, and future use of the criteria for the appropriateness of MMT. The RAND Appropriateness Method proved to be an accepted and appreciated method to assess the appropriateness of methadone maintenance treatment for opiate addicts. In the next step, the results of the expert panel process must now be combined with those of the Swiss and international literature reviews and the survey of current attitudes and practices in Switzerland, to be synthesized into formal practice guidelines. Such guidelines should be disseminated to all concerned, promoted, used and rigorously evaluated for compliance and outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluation of an Inspection Model: Homes are for Living in (1991)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Second-level school students have been identified by the Minister for health as a priority group for education on AIDS. An education programme was accordingly initiated in 1988 in Community Care Area 1 in South county Dublin. This report evaluates this education intervention by means of pre- and post- intervention questionnaires. The questionnaire examined knowledge and attitudes of students relevant to AIDS. The results showed that the level of knowledge of students living in this area was high prior to intervention. The education programme succeeded in improving some aspects of knowledge and also influenced some attitudes of the students. A study of the epidemiology of Aids in Ireland reveals that the epidemic is at a relatively early stage with a consequent rapid doubling time of 9-10 months. In comparison with most developed countries Ireland has a high proportion of AIDS cases occurring among intravenous drug abusers and directly related to this a high number of HIV infected children. Examination of the literature reveals that behaviour change has occurred most noticeably among the homosexual/bisexual risk group. There is some evidence that the comprehensive programmes can achieve change in the behaviour of intravenous drug abusers. There are very few reports linking behaviour change among adolescents and young adults to education programmes. Much of the available literature relates to changes in knowledge and attitudes. International recommendations on the nature of the ideal health education intervention on AIDS are reviewed. The importance of a comprehensive health education programme which incorporates AIDS education and which commences early in youth is noted. The role of the community physician in relation to education programmes and other aspects of monitoring and management of the AIDS epidemic is discussed.This resource was contributed by The National Documentation Centre on Drug Use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An ovitrap (BR-OVT) based on physical and chemical stimuli for attracting gravid Culex quinquefasciatus (Diptera: Culicidae) females was developed and evaluated under laboratory and field conditions. Attractants were assayed using alternative chamber bioassays prior to being used in the BR-OVT oviposition trap. A significant preference of gravid females for sites containing conspecific egg rafts was observed, as a response to the natural oviposition pheromone, as well as for sites treated with the synthetic pheromone erythro-6-acetoxy-5-hexadecanolide. Five- to 20-day old grass infusion was strongly attractive to gravid females for laying eggs. On the other hand, entomopathogenic Bacillus sphaericus (Bs) did not influence the choice of an oviposition site when used in combination with grass infusion and can therefore be used as a larvicide in ovitraps. Results from field trials showed that the BR-OVT with grass infusion and with or without Bs works as a preferred oviposition site for Cx. quinquefasciatus. The BR-OVT was more effective for egg collection when placed indoors and comparison with the number of egg rafts laid in cesspits over 40 days indicates that this very simple ovitrap may be a useful tool for monitoring populations of the most important of the vectors of bancroftian filariasis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To improve the serodiagnosis of human toxocariasis, a sensitive and specific enzyme-linked immunoelectrotransfer blot (EITB-IgG) test was developed and evaluated using Toxocara canislarvae excretory-secretory antigens for detecting anti-Toxocara IgG antibodies. The EITB-IgG profile of toxocariasis was characterized by comparing 27 sera from patients with toxocariasis, 110 sera from healthy subjects and 186 sera from patients with other helminth diseases (ascariasis, ancylostomiasis, trichuriasis, enterobiasis, strongyloidiasis, hymenolepiasis, diphyllobothriasis, taeniasis, cysticercosis, hydatidosis and fascioliasis). Antigenic bands of 24, 28, 30, 35, 56, 117, 136 and 152 kDa were predominantly recognized in sera from all patients with toxocariasis. However, only bands of 24-35 kDa were highly specific for Toxocara infection (98.3%), whereas other antigenic bands observed displayed cross-reactivity. Additionally, when the results of the EITB-IgG test were compared to those of the ELISA-IgG test, a 100% concordance was observed for positive results in human toxocariasis cases. The concordance for negative results between the two tests for healthy subjects and patients with other helminth diseases were 96.3% and 53.7%, respectively, showing that the EITB-IgG test has a higher specificity than ELISA. In conclusion, the EITB-IgG test is a very useful tool to confirm the serological diagnosis of human toxocariasis.