747 resultados para Espectrometria de fluorescencia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the new discoveries of oil and gas, the exploration of fields in various geological basins, imports of other oils and the development of alternative fuels, more and more research labs have evaluated and characterized new types of petroleum and derivatives. Therefore the investment in new techniques and equipment in the samples analysis to determine their physical and chemical properties, their composition, possible contaminants, especification of products, among others, have multiplied in last years, so development of techniques for rapid and efficient characterization is extremely important for a better economic recovery of oil. Based on this context, this work has two main objectives. The first one is to characterize the oil by thermogravimetry coupled with mass spectrometry (TG-MS), and correlate these results with from other types of characterizations data previously informed. The second is to use the technique to develop a methodology to obtain the curve of evaluation of hydrogen sulfide gas in oil. Thus, four samples were analyzed by TG-MS, and X-ray fluorescence spectrometry (XRF). TG results can be used to indicate the nature of oil, its tendency in coke formation, temperatures of distillation and cracking, and other features. It was observed in MS evaluations the behavior of oil main compounds with temperature, the points where the volatilized certain fractions and the evaluation gas analysis of sulfide hydrogen that is compared with the evaluation curve obtained by Petrobras with another methodology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many applications require that the plasma discharge is produced apart from the surface to be processed, thus preventing damage caused by bombardment and/or plasma radiation. In the post-discharge regime in various applications thermally sensitive materials can be used. In this work, active species produced by discharge and post-discharge hollow cathode were diagnosed by optical emission spectroscopy and mass spectrometry. The discharge was produced with the gases Ar and Ar - N2 gas flow ranging from 1 to 6 cm3/min and electric current between 150 to 600 mA. It was estimated that the ion density inside the hollow cathode, with 2 mm diameter ranged between 7.71 and 14.1 x 1015 cm-3. It was observed that the gas flow and the electric current changes the emission intensity of Ar and N2 species. The major ionic species detected by quadrupole mass spectrometry were Ar+ and N2+. The ratio of optical emission intensities of N2(1 +)/Ar(811 nm) was related to the partial pressure of N2 after the hollow cathode discharge at low pressure

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proposal of this work is to evaluate the influence of the organic matter on the results of the analyses of the metals (Zn, Pb, Al, Cu, Cr, Fe, Cd e Ni) for Atomic Absorption Spectrometry (AAS), so much in the extraction stage as in the reading using for that the chemometrics. They were used for this study sample of bottom sediment collected in river Jundiaí in the vicinity of the city of Macaíba-RN, commercial humus and water of the station of treatment of sewer of UFRN. Through the analyses accomplished by EAA it was verified that the interference of the organic matter happens in the extraction stage and not in the reading. With relationship to the technique of X Ray Fluorescence Spectrometry (XRFS), the present work has as intended to evaluate the viability of this technique for quantitative analysis of trace metals (Cr, Ni, Cu, Zn, Rb, Sr and Pb) in having leached obtained starting from the extraction with acqua regia for an aqueous solution. The used samples constitute the fine fraction (<0.063 mm) of sediments of swamp of the river Jundiaí. The preparation of tablets pressed starting from the dry residue of those leached it allowed your analysis in the solid form. This preliminary study shows that, in the case of the digestion chemistry partially of the fine fractions of bottom sediments used for environmental studies, the technique of applied EFRX to the analysis of dry residues starting from having leached with acqua regia, compared her it analyzes of the leached with ICP-OES, it presents relative mistakes for Cu, Pb, Sr and Zn below 10%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work examined the possibility of using mussel Mytella falcata as bioindicator sample to detect metal ions in several estuaries potiguares, since species substances that accumulate in their tissues due to its characteristics filter feeders have been used for environmental monitoring. The chemometrics by principal components analysis was used to reduce the size of the original data in order to establish a pattern of distribution of metal ion. Samples were collected at three different points in the estuaries Curimataú, Guaraíra-Papeba, Potengi, Galinhos-Guamaré and Piranhas-Assu having been marked with the location using GPS (Global Positioning System). The determination of humidity content and digestion of the samples were performed using methods described in the Compendium of analytical standards of the Institute Adofo Lutz (2005) and the determination of metal ions of the elements Al, Ba, Cd, Cr, Cu, Mn, Ni, Pb, Sn and Zn were performed by optical emission spectrometry with inductively coupled plasma as described by USEPA method 6010C. The results show that it is possible to use this molluscum Mytella falcata in the estuaries of Rio Grande do Norte for the determination of metal ions. The data were subjected to principal components analysis (PCA) which enabled us to verify the distribution pattern of the metal ions studied in several estuaries potiguares and group them according to the metal ions in common with and relate them to the activities in each region

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil contamination by pesticides is an environmental problem that needs to be monitored and avoided. However, the lack of fast, accurate and low cost analytical methods for discovering residual pesticide in complex matrices, such as soil, is a problem still unresolved. This problem needs to be solved before we are able to assess the quality of environmental samples. The intensive use of pesticides has increased since the 60s, because the dependence of their use, causing biological imbalances and promoting resistance and recurrence of high populations of pests and pathogens (upwelling). This has contributed to the appearance of new pests that were previously under natural control. To develop analytical methods that are able to quantify residues pesticide in complex environment. It is still a challenge for many laboratories. The integration of two analytical methods one ecotoxicological and another chemical demonstrates the potential for environmental analysis of methamidophos. The aim of this study was to evaluate an ecotoxicological method as "screening" analytical methamidophos in the soil and perform analytical confirmation in the samples of the concentration of the analyte by chemical method LC-MS/MS In this work we tested two soils: a clayey and sandy, both in contact with the kinetic methamidophos model followed pseudo-second order. The clay soil showed higher absorption of methamidophos and followed the Freundlich model, while the sandy, the Langmuir model. The chemical method was validated LC-MS/MS satisfactory, showing all parameters of linearity, range, precision, accuracy, and sensitivity adequate. In chronic ecotoxicological tests with C. dubia, the NOEC was 4.93 and 3.24 for ng L-1 of methamidophos to elutriate assays of sandy and clay soils, respectively. The method for ecotoxicological levels was more sensitive than LC-MS/MS detection of methamidophos, loamy and sandy soils. However, decreasing the concentration of the standard for analytical methamidophos and adjusting for the validation conditions chemical acquires a limit of quantification (LOQ) in ng L-1, consistent with the provisions of ecotoxicological test. The methods described should be used as an analytical tool for methamidophos in soil, and the ecotoxicological analysis can be used as a "screening" and LC-MS/MS as confirmatory analysis of the analyte molecule, confirming the objectives of this work

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chemical recycling of polyolefins has been the focus of increasing attention owing potential application as a fuel and as source chemicals. The use of plastic waste contributes to the solution of pollution problems.The use of catalysts can enhance the thermal degradation of synthetic polymers, which may be avaliated by Themogravimetry (TG) and mass spectrometry (MS) combined techniques. This work aims to propose alternatives to the chemistry recycling of low-density polyethylene (LDPE) on mesoporous silica type SBA-15 and AlSBA-15.The mesoporous materials type SBA-15 and AlSBA-15 were synthesized through the hydrothermal method starting from TEOS, pseudobohemite, cloridric acid HCl and water. As structure template was used Pluronic P123. The syntheses were accomplished during the period of three days. The best calcination conditions for removal of the organic template (P123) were optimized by thermal analysis (TG/DTG) and through analyses of Xray diffraction (XRD), infrared spectroscopy (FT-IR), nitrogen adsorption and scanning electron microscopy (SEM) was verified that as much the hydrothermal synthesis method as the calcination by TG were promising for the production of mesoporous materials with high degree of hexagonal ordination. The general analysis of the method of Analog Scan was performed at 10oC/min to 500 oC to avoid deterioration of capillary with very high temperatures. Thus, with the results, we observed signs mass/charge more evident and, using the MID method, was obtained curve of evolution of these signals. The addition of catalysis produced a decrease in temperature of polymer degradation proportional to the acidity of the catalyst. The results showed that the mesoporous materials contributed to the formation of compounds of lower molecular weight and higher value in the process of catalytic degradation of LDPE, representing an alternative to chemical recycling of solid waste

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces the basics of peptide mass spectra interpretation applied to proteomics and is directed to chemists, biochemists and biologists. The manuscript presents a well detailed protocol aiming to serve as a first choice guide for understanding peptide sequencing. The tutorial was elaborated based on both a thorough bibliographic revision and the author's experience. In order to prove the applicability of the proposed guide, spectra obtained on different instruments have been successfully interpreted by applying the presented rational.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)