972 resultados para Equipment contamination
Resumo:
A descriptive study was developed to monitor air fungal contamination in two elementary schools in Lisbon, Portugal. Eight air samples of 250 litres through impaction method were collected in canteen, library, classrooms and also, outside premises as reference place. Simultaneously, were also monitored environmental parameters, including temperature, and humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726 - 1998. Considering both schools, sixteen different species of fungi in air were identified, being the 2 most commonly isolated Cladosporium sp. (51,1%) and Penicillium sp. (27,5%). Besides these genera Trichoderma, Aspergillus, Alternaria, Chrysonilia, Botritys, Ulocladium, Athrium, Aureobasidium, Phoma, Scedosporium e Geotrichum were also isolated. Regarding yeasts, Candida sp., Cryptococcus sp. and Rhodotorula sp. were isolated. The youngest school, as well canteens in each school, presented the worst results concerning the air fungal contamination, maybe due to the higher number of occupants. There was no significant relationship (p>0,05) between fungal contamination and temperature and humidity.
Resumo:
A descriptive study was developed to monitor air fungal contamination in ten food units from hospitals. Fifty air samples of 250 litres were collected through impaction method. Samples were collected in food storage facilities, kitchen, food plating, canteen and also, outside premises, since this is the place regarded as reference. Simultaneously, environmental parameters were also monitored, including temperature and relative humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726.
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.
Resumo:
Organic waste is a rich substrate for microbial growth, and because of that, workers from waste industry are at higher risk of exposure to bioaerosols. This study aimed to assess fungal contamination in two plants handling solid waste management. Air samples from the two plants were collected through an impaction method. Surface samples were also collected by swabbing surfaces of the same indoor sites. All collected samples were incubated at 27◦C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. Air samples were also subjected to molecular methods by real-time polymerase chain reaction (RT PCR) using an impinger method to measure DNA of Aspergillus flavus complex and Stachybotrys chartarum. Assessment of particulate matter (PM) was also conducted with portable direct-reading equipment. Particles concentration measurement was performed at five different sizes (PM0.5; PM1; PM2.5; PM5; PM10). With respect to the waste sorting plant, three species more frequently isolated in air and surfaces were A. niger (73.9%; 66.1%), A. fumigatus (16%; 13.8%), and A. flavus (8.7%; 14.2%). In the incineration plant, the most prevalent species detected in air samples were Penicillium sp. (62.9%), A. fumigatus (18%), and A. flavus (6%), while the most frequently isolated in surface samples were Penicillium sp. (57.5%), A. fumigatus (22.3%) and A. niger (12.8%). Stachybotrys chartarum and other toxinogenic strains from A. flavus complex were not detected. The most common PM sizes obtained were the PM10 and PM5 (inhalable fraction). Since waste is the main internal fungal source in the analyzed settings, preventive and protective measures need to be maintained to avoid worker exposure to fungi and their metabolites.
Resumo:
BACKGROUND. The phenomenon of misdiagnosing tuberculosis (TB) by laboratory cross-contamination when culturing Mycobacterium tuberculosis (MTB) has been widely reported and it has an obvious clinical, therapeutic and social impact. The final confirmation of a cross-contamination event requires the molecular identification of the same MTB strain cultured from both the potential source of the contamination and from the false-positive candidate. The molecular tool usually applied in this context is IS6110-RFLP which takes a long time to provide an answer, usually longer than is acceptable for microbiologists and clinicians to make decisions. Our purpose in this study is to evaluate a novel PCR-based method, MIRU-VNTR as an alternative to assure a rapid and optimized analysis of cross-contamination alerts. RESULTS. MIRU-VNTR was prospectively compared with IS6110-RFLP for clarifying 19 alerts of false positivity from other laboratories. MIRU-VNTR highly correlated with IS6110-RFLP, reduced the response time by 27 days and clarified six alerts unresolved by RFLP. Additionally, MIRU-VNTR revealed complex situations such as contamination events involving polyclonal isolates and a false-positive case due to the simultaneous cross-contamination from two independent sources. CONCLUSION. Unlike standard RFLP-based genotyping, MIRU-VNTR i) could help reduce the impact of a false positive diagnosis of TB, ii) increased the number of events that could be solved and iii) revealed the complexity of some cross-contamination events that could not be dissected by IS6110-RFLP.
Resumo:
The microbiological quality of beef and meat products is strongly influenced by the conditions of hygiene prevailing during their production and handling. Without proper hygienic control, the environment in slaughterhouses and butcher shops can act as an important source of microbiological contamination. To identify the main points of microbiological contamination in the beef processing chain, 443 samples of equipment, installations and products were collected from 11 establishments (1 slaughterhouse and 10 butcher shops) located in the state of Paraná, Brazil. The microbiological quality of all the samples was evaluated using Petri dishes to obtain counts of mesophilic aerobes (AC), total coliforms, Escherichia coli (EC), yeasts and molds (YM). The main contamination points identified in butcher shops, in decreasing order, were stainless steel boxes, beef tenderizers, grinders, knives, mixers, sausage stuffers, plastic boxes, floors and drains. In the slaughterhouse, these points were sausage stuffers, platforms, floors and drains. The most severely contaminated products were fresh sausages and ground beef. This information about the main points of microbiological contamination in the beef processing chain is expected to aid professionals responsible for hygiene in similar establishments to set up proper hygienic procedures to prevent or reduce microbiological contamination of beef and meat products.
Resumo:
This study focuses on the presence of radon (Rn-222) and volatile organic compounds (VOCs) in soil gases at a gas station located in the city of Rio Claro, Sao Paulo, Brazil, where a fossil fuel leak occurred. The spatial distribution results show a correlation between Rn-222 and VOCs, consistent with the fact that radon gas has a greater chemical affinity with organic phases than with water. This finding demonstrates that the presence of a residual hydrocarbon phase in an aquifer can retain radon, leading to a reduced radon content in the soil gas. The data in this study confirm the results of previous investigations, in which the method used in this study provided a preliminary fingerprint of a contaminated area. Furthermore, the data analysis time is brief, and only simple equipment is required. (C) 2014 Published by Elsevier Ltd.
Resumo:
A descriptive study was developed to monitor air fungal contamination in ten food units from hospitals. Fifty air samples of 250 litres were collected through impaction method. Samples were collected in food storage facilities, kitchen, food plating, canteen and also, outside premises, since this is the place regarded as reference. Simultaneously, environmental parameters were also monitored, including temperature and relative humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726.
Resumo:
The application of sand filters in localized irrigation systems is recommended in the presence of organic and algae contamination. The proper design and maintenance of these equipments are essential to assure an effective water quality control, in order to reduce the emitters clogging, to keep its water application uniformity, and to prevent increasing in the system operation costs. Despite the existence of some references about design, operation and maintenance of these filters, they are dispersed, with not enough details to guarantee the optimization of its hydraulics structure design and the proper selection of porous media to be used. Therefore, the objective of this work was to report a current literature review, relating practical information with scientific knowledge. The content of this review would help to induce and intensify the research on this subject and to contribute so the operational functions for the equipment are reached. It is also expected to assist the improvement of the filtration and flushing processes in the agricultural irrigation and the development of original design procedures and the rational use of these devices.
Resumo:
PURPOSE: The aim of this study was to assess the contamination status of endodontic absorbent paper points from sterilized or not sterilized commercial packs, as well as paper points exposed to the dental office environment. METHODS: Twenty absorbent paper points were evaluated for contamination status packed under different conditions: commercial/sterilized pack, commercial/non-sterilized pack, exposed to the clinical environment, and intentionally contaminated (positive control). Contamination was determined qualitatively and quantitatively by aerobiosis, capnophilic growth, and pour plate. The Petri dishes were analyzed with a colony counter, and the results were expressed as colony-forming units. The data were analyzed by Kruskal-Wallis test (α=0.05). RESULTS: No difference in colony-forming units was found among the groups of endodontic absorbent paper points. All groups were contaminated by fungi and bacteria. CONCLUSION: It can be concluded that the sterilization of absorbent endodontic paper points before clinical use should be recommended regardless of commercial presentation
Resumo:
The Piracicaba River basin is considered the most disturbed river basin in the state of So Paulo. Considerable amounts of agricultural residues are seasonally drained into the river, and the region is also highly urbanized and industrialized with an incipient sewage treatment system. The presence of heavy metals has been previously reported for the water and riverbed in Piracicaba river basin. In this study we evaluated 13 heavy metals in the blood of 37 Geoffroy`s side-necked turtles, Phrynops geoffroanus, from Piracicaba River and Piracicamirim Creek, one of its tributaries. Blood levels of As, Co, Cr, Se and Pb varied among sites, whereas Sn varied between males and females. However, no obvious pathology was detected. Serum level of Cu (2,194 ng g(-1)) and Pb (1,150 ng g(-1)) found in this study are the highest ever described for any reptile; however, no clinical symptoms have been detected in the present study. There is no information about the time scale of such contamination, which could be currently subclinical and yet lead to a breakdown in the population reproductive success in a few years. Based on the present study, legal enforcement is urged in order to locate and extirpate heavy metal sources in the Piracicaba River basin. In addition, monitoring should include humans and commercial fish consumed in local markets.
Resumo:
Resuspended soil and other airborne particles adhered to the leaf surface affect the chemical composition of the plant. A well-defined cleaning procedure is necessary to avoid this problem, providing a correct assessment of the inherent chemical composition of bromeliads. To evaluate the influence of a washing procedure, INAA was applied for determining chemical elements in the leaves of bromeliads from Vriesea carinata species, both non-washed and washed with Alconox, EDTA and bi-distilled water. Br, Ce, Hg, La, Sc, Se, Sm and Th showed higher mass fractions in non-washed leaves. The washing procedure removed the exogenous material without leaching chemical elements from inside the tissues.
Resumo:
Objective: To evaluate the potential risk of surgical contamination by the venting port of ordinary electric drills (ED) employed in orthopaedic surgeries. Materials and Methods: an experimental laboratory, randomized study was developed to analyze EDs in surgical practice and new cleaned and sterilized equipment, which were contaminated with Bacillus atrophaeus spores at a concentration of 84 X 10(6) UFC. The air generated by the engine of each drill was collected and cultivated on sterile agar plates. Results: Positive culture was identified in two ED in surgical practice, as well as a positive culture to Bacillus atrophaeus with 1 CFU growth (1, 19 X 10(-8)). Conclusion: In the conditions of the experiment, the air generated by the venting port of the ED`s engine does not consist of a source of contamination for the surgical site.