813 resultados para Engineering, Electronics and Electrical|Health Sciences, Radiology|Biophysics, Medical


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ce(0.8)SM(0.2)O(1.9) and CeO(2) nanomaterials were prepared by a solution technique to produce an ultrafine particulate material with high sinterability. In this work, the structural characteristics, the photoluminescent behavior and the ionic conductivity of the synthesized materials are focused. The thermally decomposed material consists of less than 10 nm in diameter nanoparticles. The Raman spectrum of pure CeO(2) consists of a single triple degenerate F(2g) model characteristic of the fluorite-like structure. The full width at half maximum of this band decreases linearly with increasing calcination temperature. The photoluminescence spectra show a broadened emission band assigned to the ligand-to-metal charge-transfer states O -> Ce(4+). The emission spectra of the Ce(0.8)Sm(0.2)O(1.9) specimens present narrow bands arising from the 4G(5/2) -> (6)H(J) transitions (J = 5/2, 7/2, 9/2 and 11/2) of Sm(3+) ion due to the efficient energy transfer from the O -> Ce(4+) transitions to the emitter 4G(5/2) level. The ionic conductivity of sintered specimens shows a significant dependence on density. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although powder metallurgical methods have been used for years to fabricate tungsten and platinum, very little scientific data have been recorded until the beginning of this century. A large percentage of all commercial production at present is based upon past practice rather than upon scientific knowledge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purposes of this study were to examine (1) the relationship between selected components of the content of prenatal care and spontaneous preterm birth; and (2) the degree of comparability between maternal and caregivers' responses regarding the number of prenatal care visits, selected components of the content of prenatal care, and gestational age, based on analyses of the 1988 National Maternal and Infant Health Survey conducted by the National Centers for Health Statistics. Spontaneous preterm birth was subcategorized into very preterm and moderately preterm births, with term birth as the controls. The study population was limited to non-Hispanic Anglo- and African-American mothers. The racial differences in terms of birth outcomes were also compared.^ This study concluded that: (1) there was not a high degree of comparability (less than 80%) between maternal and prenatal care provider's responses regarding the number of prenatal care visits and the content of prenatal care; (2) there was a low degree of comparability (less than 50%) between maternal and infant's hospital of delivery responses regarding gestational age at birth; (3) there were differences in selected components of the content of prenatal care between the cases and controls, overall and stratified by ethnicity (i.e., hemoglobin/hematocrit test, weight measurement, and breast-feeding counseling), but they were confounded with missing values and associated preterm delivery bias; (4) there were differences in selected components of the content of prenatal care between Anglo- and African-American cases (i.e., vitamin/mineral supplement advice, weight measurement, smoking cessation and drug abuse counseling), but they, too, were difficult to interpret definitively due to item nonresponse and preterm delivery biases; (5) no significant predictive association between selected components of the content of prenatal care and spontaneous preterm birth was found; and (6) inadequate/intermediate prenatal care and birth out of wedlock were found to be associated with moderately preterm birth.^ Future research is needed to examine the validity of maternal and prenatal care providers' responses and identify the sources of disagreement between their responses. In addition, further studies are needed to examine the relationship between the quality of prenatal care and preterm birth. Finally, the completeness and quality of patient and provider data on the utilization and content of prenatal care needs to be strengthened in subsequent studies. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A cohort study study design was used to study the relationship of maternal low birthweight and infant low birthweight among African American women delivering full term infants. The cohort consisted of 3,157 mother-infant pairs drawn from the 1988 National Maternal and Infant Health Survey conducted by the National Center for Health Statistics. The objectives of the study were (1) to determine if low birthweight, African American mothers delivering term infants experienced higher rates of infant low birthweight and (2) to examine the role of selected contributory variables in the relationship of maternal low birthweight and infant low birthweight. Contributory risk factors examined included maternal marital status, maternal age, maternal education, maternal height, maternal prepregnant weight, birth order, history of a prior low birthweight delivery, timing of prenatal care, number of prenatal visits, gestational length, infant gender, and behavioral factors of smoking, alcohol, and illicit drug use during pregnancy.^ Using logistic regression analysis, risk of infant low birthweight among maternal low birthweight mothers increased after controlling for less than a high school education, less than 20 years of age, prepregnant weight less than 100 lbs, history of a prior low birthweight delivery, birth order, smoking during pregnancy, and use of alcohol and illicit drugs during pregnancy, but was not statistically significant. Loss of statistical significance was attributed to a large reduction in cases available for analysis after including illicit drug use in the model.^ This study demonstrated a consistent pattern of increased rates of infant low birthweight among low birthweight mothers. The force of history remains, hence women with this trait should be carefully monitored and advised during pregnancy to decrease risk of a low birthweight infant, in order to decrease the chain of events leading to future generations of low birthweight mothers. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Environmental tobacco smoke (ETS) is a well established health hazard, being causally associated to lung cancer and cardiovascular disease. ETS regulations have been developed worldwide to reduce or eliminate exposure in most public places. Restaurants and bars constitute an exception. Restaurants and bar workers experience the highest ETS exposure levels across several occupations, with correspondingly increased health risks. In Mexico, previous exposure assessment in restaurants and bars showed concentrations in bars and restaurants to be the highest across different public and workplaces. Recently, Mexico developed at the federal level the General Law for Tobacco Control restricting indoors smoking to separated areas. AT the local level Mexico City developed the Law for the Protection of Non-smokers Health, completely banning smoking in restaurants and bars. Studies to assess ETS exposure in restaurants and bars, along with potential health effects were required to evaluate the impact of these legislative changes and to set a baseline measurement for future evaluations.^ A large cross-sectional study conducted in restaurants and bars from four Mexican cities was conducted from July to October 2008, to evaluate the following aims: Aim 1) Explore the potential impact of the Mexico City ban on ETS concentrations through comparison of Mexico City with other cities. Aim 2). Explore the association between ETS exposure, respiratory function indicators and respiratory symptoms. Aim 3). Explore the association between ETS exposure and blood pressure and heart rate.^ Three cities with no smoking ban were selected: Colima (11.5% smoking prevalence), Cuernavaca (21.5% smoking prevalence) and Toluca (27.8% smoking prevalence). Mexico City (27.9% smoking prevalence), the only city with a ban at the time of the study, was also selected. Restaurants and bars were randomly selected from municipal records. A goal of 26 restaurants and 26 bars per city was set, 50% of them under 100 m2. Each establishment was visited during the highest occupancy shift, and managers and workers answered to a questionnaire. Vapor-phase nicotine was measured using passive monitors, that were activated at the beginning and deactivated at the end of the shift. Also, workers participated at the beginning and end of the shift in a short physical evaluation, comprising the measurement of Forced Expiratory Volume in the first second (FEV1) and Peak Expiratory Flow (PEF), as well as blood pressure and heart rate.^ A total of 371 establishments were invited, 219 agreed to participate for a 60.1% participation rate. In them, 828 workers were invited, 633 agreed to participate for a 76% participation rate. Mexico City had at least 4 times less nicotine compared to any of the other cities. Differences between Mexico City and other cities were not explained by establishment characteristics, such as ventilation or air extraction. However, differences between cities disappeared when ban mechanisms, such as policy towards costumer's smoking, were considered in the models. An association between ETS exposure and respiratory symptoms (cough OR=1.27, 95%CI=1.04, 1.55) and respiratory illness (asthma OR=1.97, 95%CI=1.20, 3.24; respiratory illness OR=1.79, 95%CI=1.10, 2.94) was observed. No association between ETS and phlegm, wheezing or respiratory infections was observed. No association between ETS and any of the spirometric indicators was observed. An association between ETS exposure and increased systolic and diastolic blood pressure at the end of the shift was observed among non-smokers (systolic blood pressure beta=1.51, 95%CI=0.44, 2.58; diastolic blood pressure beta=1.50, 95%CI=0.72, 2.28). The opposite effect was observed in heavy smokers, were increased ETS exposure was associated with lower blood pressure at the end of the shift (systolic blood pressure beta=1.90, 95%CI=-3.57, -0.23; diastolic blood pressure beta=-1.46, 95%CI=-2.72, -0.02). No association in light smokers was observed. No association for heart rate was observed. ^ Results from this dissertation suggest Mexico City's smoking ban has had a larger impact on ETS exposure. Ventilation or air extraction, mechanisms of ETS control suggested frequently by tobacco companies to avoid smoking bans were not associated with ETS exposure. This dissertation suggests ETS exposure could be linked to changes in blood pressure and to increased respiratory symptoms. Evidence derived from this dissertation points to the potential negative health effects of ETS exposure in restaurants and bars, and provides support for the development of total smoking bans in this economic sector. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study aim was to determine whether using automated side loader (ASL) trucks in higher proportions compared to other types of trucks for residential waste collection results in lower injury rates (from all causes). The primary hypothesis was that the risk of injury to workers was lower for those who work with ASL trucks than for workers who work with other types of trucks used in residential waste collection. To test this hypothesis, data were collected from one of the nation’s largest companies in the solid waste management industry. Different local operating units (i.e. facilities) in the company used different types of trucks to varying degrees, which created a special opportunity to examine refuse collection injuries and illnesses and the risk reduction potential of ASL trucks.^ The study design was ecological and analyzed end-of-year data provided by the company for calendar year 2007. During 2007, there were a total of 345 facilities which provided residential services. Each facility represented one observation.^ The dependent variable – injury and illness rate, was defined as a facility’s total case incidence rate (TCIR) recorded in accordance with federal OSHA requirements for the year 2007. The TCIR is the rate of total recordable injury and illness cases per 100 full-time workers. The independent variable, percent of ASL trucks, was calculated by dividing the number of ASL trucks by the total number of residential trucks at each facility.^ Multiple linear regression models were estimated for the impact of the percent of ASL trucks on TCIR per facility. Adjusted analyses included three covariates: median number of hours worked per week for residential workers; median number of months of work experience for residential workers; and median age of residential workers. All analyses were performed with the statistical software, Stata IC (version 11.0).^ The analyses included three approaches to classifying exposure, percent of ASL trucks. The first approach included two levels of exposure: (1) 0% and (2) >0 - <100%. The second approach included three levels of exposure: (1) 0%, (2) ≥ 1 - < 100%, and (3) 100%. The third approach included six levels of exposure to improve detection of a dose-response relationship: (1) 0%, (2) 1 to <25%, (3) 25 to <50%, (4) 50 to <75%, (5) 75 to <100%, and (6) 100%. None of the relationships between injury and illness rate and percent ASL trucks exposure levels was statistically significant (i.e., p<0.05), even after adjustment for all three covariates.^ In summary, the present study shows that there is some risk reduction impact of ASL trucks but not statistically significant. The covariates demonstrated a varied yet more modest impact on the injury and illness rate but again, none of the relationships between injury and illness rate and the covariates were statistically significant (i.e., p<0.05). However, as an ecological study, the present study also has the limitations inherent in such designs and warrants replication in an individual level cohort design. Any stronger conclusions are not suggested.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three approaches were used to examine the role of Ca$\sp{2+}$- and/or calmodulin (CaM)-regulated processes in the mammalian heat stress response. The focus of the first approach was on the major Ca$\sp{2+}$-binding protein, CaM, and involved the use of CaM antagonists that perturbed CaM-regulated processes during heat stress. The second approach involved the use of a cell line and its BPV-1 transformants that express increased basal levels of CaM, or parvalbumin--a Ca$\sp{2+}$-binding protein not normally found in these cells. The last approach used Ca$\sp{2+}$ chelators to buffer Ca$\sp{2+}$-transients.^ The principle conclusions resulting from these three experimental approaches are: (1) CaM antagonists cause a temperature-dependent potentiation of heat killing, but do not inhibit the triggering and development of thermotolerance suggesting some targets for heat killing are different from those that lead to thermotolerance; (2) Members of major HSP families (especially HSP70) can bind to CaM in a Ca$\sp{2+}$-dependent manner in vitro, and HSP have been associated with events leading to thermotolerance. But, because thermotolerance is not affected by CaM antagonists, and antagonists should interfere with HSP binding to CaM, the events leading to triggering or developing thermotolerance were not strongly dependent on HSP binding to CaM; (3) CaM antagonists can also bind to HSP70 (and possibly other HSP) suggesting an alternative mechanism for the action of these agents in heat killing may involve direct binding to other proteins, like HSP70, whose function is important for survival following heating and inhibiting their activity; and (4) The signal governing the rate of synthesis of another major HSP group, the HSP26 family, can be largely abrogated by elevated Ca$\sp{2+}$-binding proteins or Ca$\sp{2+}$ chelators without significantly reducing survival or thermotolerance suggesting if the HSP26 family is involved in either end point, it may function in (Ca$\sp{2+}$) $\sb{\rm i}$ homeostasis. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three new technologies have been brought together to develop a miniaturized radiation monitoring system. The research involved (1) Investigation a new HgI$\sb2$ detector. (2) VHDL modeling. (3) FPGA implementation. (4) In-circuit Verification. The packages used included an EG&G's crystal(HgI$\sb2$) manufactured at zero gravity, the Viewlogic's VHDL and Synthesis, Xilinx's technology library, its FPGA implementation tool, and a high density device (XC4003A). The results show: (1) Reduced cycle-time between Design and Hardware implementation; (2) Unlimited Re-design and implementation using the static RAM technology; (3) Customer based design, verification, and system construction; (4) Well suited for intelligent systems. These advantages excelled conventional chip design technologies and methods in easiness, short cycle time, and price in medium sized VLSI applications. It is also expected that the density of these devices will improve radically in the near future. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In 1972 the ionized cluster beam (ICB) deposition technique was introduced as a new method for thin film deposition. At that time the use of clusters was postulated to be able to enhance film nucleation and adatom surface mobility, resulting in high quality films. Although a few researchers reported singly ionized clusters containing 10$\sp2$-10$\sp3$ atoms, others were unable to repeat their work. The consensus now is that film effects in the early investigations were due to self-ion bombardment rather than clusters. Subsequently in recent work (early 1992) synthesis of large clusters of zinc without the use of a carrier gas was demonstrated by Gspann and repeated in our laboratory. Clusters resulted from very significant changes in two source parameters. Crucible pressure was increased from the earlier 2 Torr to several thousand Torr and a converging-diverging nozzle 18 mm long and 0.4 mm in diameter at the throat was used in place of the 1 mm x 1 mm nozzle used in the early work. While this is practical for zinc and other high vapor pressure materials it remains impractical for many materials of industrial interest such as gold, silver, and aluminum. The work presented here describes results using gold and silver at pressures of around 1 and 50 Torr in order to study the effect of the pressure and nozzle shape. Significant numbers of large clusters were not detected. Deposited films were studied by atomic force microscopy (AFM) for roughness analysis, and X-ray diffraction.^ Nanometer size islands of zinc deposited on flat silicon substrates by ICB were also studied by atomic force microscopy and the number of atoms/cm$\sp2$ was calculated and compared to data from Rutherford backscattering spectrometry (RBS). To improve the agreement between data from AFM and RBS, convolution and deconvolution algorithms were implemented to study and simulate the interaction between tip and sample in atomic force microscopy. The deconvolution algorithm takes into account the physical volume occupied by the tip resulting in an image that is a more accurate representation of the surface.^ One method increasingly used to study the deposited films both during the growth process and following, is ellipsometry. Ellipsometry is a surface analytical technique used to determine the optical properties and thickness of thin films. In situ measurements can be made through the windows of a deposition chamber. A method for determining the optical properties of a film, that is sensitive only to the growing film and accommodates underlying interfacial layers, multiple unknown underlayers, and other unknown substrates was developed. This method is carried out by making an initial ellipsometry measurement well past the real interface and by defining a virtual interface in the vicinity of this measurement. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of this research are to analyze and develop a modified Principal Component Analysis (PCA) and to develop a two-dimensional PCA with applications in image processing. PCA is a classical multivariate technique where its mathematical treatment is purely based on the eigensystem of positive-definite symmetric matrices. Its main function is to statistically transform a set of correlated variables to a new set of uncorrelated variables over $\IR\sp{n}$ by retaining most of the variations present in the original variables.^ The variances of the Principal Components (PCs) obtained from the modified PCA form a correlation matrix of the original variables. The decomposition of this correlation matrix into a diagonal matrix produces a set of orthonormal basis that can be used to linearly transform the given PCs. It is this linear transformation that reproduces the original variables. The two-dimensional PCA can be devised as a two successive of one-dimensional PCA. It can be shown that, for an $m\times n$ matrix, the PCs obtained from the two-dimensional PCA are the singular values of that matrix.^ In this research, several applications for image analysis based on PCA are developed, i.e., edge detection, feature extraction, and multi-resolution PCA decomposition and reconstruction. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clusters are aggregations of atoms or molecules, generally intermediate in size between individual atoms and aggregates that are large enough to be called bulk matter. Clusters can also be called nanoparticles, because their size is on the order of nanometers or tens of nanometers. A new field has begun to take shape called nanostructured materials which takes advantage of these atom clusters. The ultra-small size of building blocks leads to dramatically different properties and it is anticipated that such atomically engineered materials will be able to be tailored to perform as no previous material could.^ The idea of ionized cluster beam (ICB) thin film deposition technique was first proposed by Takagi in 1972. It was based upon using a supersonic jet source to produce, ionize and accelerate beams of atomic clusters onto substrates in a vacuum environment. Conditions for formation of cluster beams suitable for thin film deposition have only recently been established following twenty years of effort. Zinc clusters over 1,000 atoms in average size have been synthesized both in our lab and that of Gspann. More recently, other methods of synthesizing clusters and nanoparticles, using different types of cluster sources, have come under development.^ In this work, we studied different aspects of nanoparticle beams. The work includes refinement of a model of the cluster formation mechanism, development of a new real-time, in situ cluster size measurement method, and study of the use of ICB in the fabrication of semiconductor devices.^ The formation process of the vaporized-metal cluster beam was simulated and investigated using classical nucleation theory and one dimensional gas flow equations. Zinc cluster sizes predicted at the nozzle exit are in good quantitative agreement with experimental results in our laboratory.^ A novel in situ real-time mass, energy and velocity measurement apparatus has been designed, built and tested. This small size time-of-flight mass spectrometer is suitable to be used in our cluster deposition systems and does not suffer from problems related to other methods of cluster size measurement like: requirement for specialized ionizing lasers, inductive electrical or electromagnetic coupling, dependency on the assumption of homogeneous nucleation, limits on the size measurement and non real-time capability. Measured ion energies using the electrostatic energy analyzer are in good accordance with values obtained from computer simulation. The velocity (v) is measured by pulsing the cluster beam and measuring the time of delay between the pulse and analyzer output current. The mass of a particle is calculated from m = (2E/v$\sp2).$ The error in the measured value of background gas mass is on the order of 28% of the mass of one N$\sb2$ molecule which is negligible for the measurement of large size clusters. This resolution in cluster size measurement is very acceptable for our purposes.^ Selective area deposition onto conducting patterns overlying insulating substrates was demonstrated using intense, fully-ionized cluster beams. Parameters influencing the selectivity are ion energy, repelling voltage, the ratio of the conductor to insulator dimension, and substrate thickness. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent advances in telecommunications technologies have transformed the modes of learning and teaching. One potentially vital component in the equation will be Remote Education or Remote Learning, the ability to compress time and space between teachers and students through the judicious application of technology. The purpose of this thesis is to develop a Remote Learning and Laboratory Center over the Internet and ISDN, which provide education and access to resources to those living in remote areas, children in hospitals and traveling families, with audio, video and data.^ Remote Learning and Laboratory Center (RLLC) is not restricted to merely traditional education processes such as universities or colleges, it can be very useful for companies to train their engineers, via networks. This capability will facilitate the best use of scarce, high quality educational resources and will bring equity of services to students as well as will be helpful to the Industries to train their engineers. The RLLC over the Internet and ISDN has been described in details and implemented successfully. For the Remote Laboratory, the experiment procedure has been demonstrated on reprogrammable CPLD design using ISR Kit. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Small errors proved catastrophic. Our purpose to remark that a very small cause which escapes our notice determined a considerable effect that we cannot fail to see, and then we say that the effect is due to chance. Small differences in the initial conditions produce very great ones in the final phenomena. A small error in the former will produce an enormous error in the latter. When dealing with any kind of electrical device specification, it is important to note that there exists a pair of test conditions that define a test: the forcing function and the limit. Forcing functions define the external operating constraints placed upon the device tested. The actual test defines how well the device responds to these constraints. Forcing inputs to threshold for example, represents the most difficult testing because this put those inputs as close as possible to the actual switching critical points and guarantees that the device will meet the Input-Output specifications. ^ Prediction becomes impossible by classical analytical analysis bounded by Newton and Euclides. We have found that non linear dynamics characteristics is the natural state of being in all circuits and devices. Opportunities exist for effective error detection in a nonlinear dynamics and chaos environment. ^ Nowadays there are a set of linear limits established around every aspect of a digital or analog circuits out of which devices are consider bad after failing the test. Deterministic chaos circuit is a fact not a possibility as it has been revived by our Ph.D. research. In practice for linear standard informational methodologies, this chaotic data product is usually undesirable and we are educated to be interested in obtaining a more regular stream of output data. ^ This Ph.D. research explored the possibilities of taking the foundation of a very well known simulation and modeling methodology, introducing nonlinear dynamics and chaos precepts, to produce a new error detector instrument able to put together streams of data scattered in space and time. Therefore, mastering deterministic chaos and changing the bad reputation of chaotic data as a potential risk for practical system status determination. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation is about the research carried on developing an MPS (Multipurpose Portable System) which consists of an instrument and many accessories. The instrument is portable, hand-held, and rechargeable battery operated, and it measures temperature, absorbance, and concentration of samples by using optical principles. The system also performs auxiliary functions like incubation and mixing. This system can be used in environmental, industrial, and medical applications. ^ Research emphasis is on system modularity, easy configuration, accuracy of measurements, power management schemes, reliability, low cost, computer interface, and networking. The instrument can send the data to a computer for data analysis and presentation, or to a printer. ^ This dissertation includes the presentation of a full working system. This involved integration of hardware and firmware for the micro-controller in assembly language, software in C and other application modules. ^ The instrument contains the Optics, Transimpedance Amplifiers, Voltage-to-Frequency Converters, LCD display, Lamp Driver, Battery Charger, Battery Manager, Timer, Interface Port, and Micro-controller. ^ The accessories are a Printer, Data Acquisition Adapter (to transfer the measurements to a computer via the Printer Port and expand the Analog/Digital conversion capability), Car Plug Adapter, and AC Transformer. This system has been fully evaluated for fault tolerance and the schemes will also be presented. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel and new thermal management technology for advanced ceramic microelectronic packages has been developed incorporating miniature heat pipes embedded in the ceramic substrate. The heat pipes use an axially grooved wick structure and water as the working fluid. Prototype substrate/heat pipe systems were fabricated using high temperature co-fired ceramic (alumina). The heat pipes were nominally 81 mm in length, 10 mm in width, and 4 mm in height, and were charged with approximately 50–80 μL of water. Platinum thick film heaters were fabricated on the surface of the substrate to simulate heat dissipating electronic components. Several thermocouples were affixed to the substrate to monitor temperature. One end of the substrate was affixed to a heat sink maintained at constant temperature. The prototypes were tested and shown to successful and reliably operate with thermal loads over 20 Watts, with thermal input from single and multiple sources along the surface of the substrate. Temperature distributions are discussed for the various configurations and the effective thermal resistance of the substrate/heat pipe system is calculated. Finite element analysis was used to support the experimental findings and better understand the sources of the system's thermal resistance. ^