989 resultados para Electromechanical impedance techniques
Resumo:
An impedance-based midspan debonding identification method for RC beams strengthened with FRP strips is presented in this paper using piezoelectric ceramic (PZT) sensor?actuators. To reach this purpose, firstly, a two-dimensional electromechanical impedance model is proposed to predict the electrical admittance of the PZT transducer bonded to the FRP strips of an RC beam. Considering the impedance is measured in high frequencies, a spectral element model of the bonded-PZT?FRP strengthened beam is developed. This model, in conjunction with experimental measurements of PZT transducers, is used to present an updating methodology to quantitatively detect interfacial debonding of these kinds of structures. To improve the performance and accuracy of the detection algorithm in a challenging problem such as ours, the structural health monitoring approach is solved with an ensemble process based on particle of swarm. An adaptive mesh scheme has also been developed to increase the reliability in locating the area in which debonding initiates. Predictions carried out with experimental results have showed the effectiveness and potential of the proposed method to detect prematurely at its earliest stages a critical failure mode such as that due to midspan debonding of the FRP strip.
Resumo:
Bioelectrical impedance analysis, (BIA), is a method of body composition analysis first investigated in 1962 which has recently received much attention by a number of research groups. The reasons for this recent interest are its advantages, (viz: inexpensive, non-invasive and portable) and also the increasing interest in the diagnostic value of body composition analysis. The concept utilised by BIA to predict body water volumes is the proportional relationship for a simple cylindrical conductor, (volume oc length2/resistance), which allows the volume to be predicted from the measured resistance and length. Most of the research to date has measured the body's resistance to the passage of a 50· kHz AC current to predict total body water, (TBW). Several research groups have investigated the application of AC currents at lower frequencies, (eg 5 kHz), to predict extracellular water, (ECW). However all research to date using BIA to predict body water volumes has used the impedance measured at a discrete frequency or frequencies. This thesis investigates the variation of impedance and phase of biological systems over a range of frequencies and describes the development of a swept frequency bioimpedance meter which measures impedance and phase at 496 frequencies ranging from 4 kHz to 1 MHz. The impedance of any biological system varies with the frequency of the applied current. The graph of reactance vs resistance yields a circular arc with the resistance decreasing with increasing frequency and reactance increasing from zero to a maximum then decreasing to zero. Computer programs were written to analyse the measured impedance spectrum and determine the impedance, Zc, at the characteristic frequency, (the frequency at which the reactance is a maximum). The fitted locus of the measured data was extrapolated to determine the resistance, Ro, at zero frequency; a value that cannot be measured directly using surface electrodes. The explanation of the theoretical basis for selecting these impedance values (Zc and Ro), to predict TBW and ECW is presented. Studies were conducted on a group of normal healthy animals, (n=42), in which TBW and ECW were determined by the gold standard of isotope dilution. The prediction quotients L2/Zc and L2/Ro, (L=length), yielded standard errors of 4.2% and 3.2% respectively, and were found to be significantly better than previously reported, empirically determined prediction quotients derived from measurements at a single frequency. The prediction equations established in this group of normal healthy animals were applied to a group of animals with abnormally low fluid levels, (n=20), and also to a group with an abnormal balance of extra-cellular to intracellular fluids, (n=20). In both cases the equations using L2/Zc and L2/Ro accurately and precisely predicted TBW and ECW. This demonstrated that the technique developed using multiple frequency bioelectrical impedance analysis, (MFBIA), can accurately predict both TBW and ECW in both normal and abnormal animals, (with standard errors of the estimate of 6% and 3% for TBW and ECW respectively). Isotope dilution techniques were used to determine TBW and ECW in a group of 60 healthy human subjects, (male. and female, aged between 18 and 45). Whole body impedance measurements were recorded on each subject using the MFBIA technique and the correlations between body water volumes, (TBW and ECW), and heighe/impedance, (for all measured frequencies), were compared. The prediction quotients H2/Zc and H2/Ro, (H=height), again yielded the highest correlation with TBW and ECW respectively with corresponding standard errors of 5.2% and 10%. The values of the correlation coefficients obtained in this study were very similar to those recently reported by others. It was also observed that in healthy human subjects the impedance measured at virtually any frequency yielded correlations not significantly different from those obtained from the MFBIA quotients. This phenomenon has been reported by other research groups and emphasises the need to validate the technique by investigating its application in one or more groups with abnormalities in fluid levels. The clinical application of MFBIA was trialled and its capability of detecting lymphoedema, (an excess of extracellular fluid), was investigated. The MFBIA technique was demonstrated to be significantly more sensitive, (P<.05), in detecting lymphoedema than the current technique of circumferential measurements. MFBIA was also shown to provide valuable information describing the changes in the quantity of muscle mass of the patient during the course of the treatment. The determination of body composition, (viz TBW and ECW), by MFBIA has been shown to be a significant improvement on previous bioelectrical impedance techniques. The merit of the MFBIA technique is evidenced in its accurate, precise and valid application in animal groups with a wide variation in body fluid volumes and balances. The multiple frequency bioelectrical impedance analysis technique developed in this study provides accurate and precise estimates of body composition, (viz TBW and ECW), regardless of the individual's state of health.
Resumo:
La0.5Li0.5TiO3 perovskite was synthesized by various wet chemical methods. By adopting low temperature methods of preparation lithium loss from the material is prevented. La0.5Li0.5TiO3 (LLTO) was formed with cubic symmetry at 1473 K. LLTO was formed at relatively lower temperature by using hydrothermal preparation method. PVA gel-decomposition route yield tetragonal LLTO on annealing the dried gel at 1473 K. By using gel-carbonate route LiTi2O4 minor phase was found to remain even after heat-treatment at 1473 K. The hydroxylation of LLTO was done in deionized water as well as in dilute acetic acid medium. By hydroxylation process incorporation of hydroxyls and leaching out of Li+ was observed from the material. The Li+ concentration of these compositions was examined by AAS. The electrical conductivities of these compositions were measured by dc and ac impedance techniques at elevated temperatures. The activation energies of electrical conduction for these compositions were estimated from the experimental results. The measured activation energy of Li+ conduction is 0.34 eV. Unhydroxylated samples exhibit only Li+ conduction, whereas, the hydroxylated LLTO show proton conductivity at 298-550 K in addition to Li+ conductivity. The effect of Zr or Ce substitution in place of Ti were attempted. La0.5Li0.5ZrO3 Perovskite was not formed; instead pyrochlore phase (La2Zr2O7) along with monoclinic ZrO2 phases was observed above 1173 K; below 1173 K cubic ZrO2 is stable. (La0.5Li0.5)(2)CeO4 solid solution was formed in the case of Ce substitution at Ti sublattice on heat-treatment up to 1673 K. (c) 2005 Springer Science + Business Media, Inc.
Resumo:
The dihexyl substituted poly (3,4-propylenedioxythiophene) (PProDOT-Hx(2)) thin films uniformly deposited by cost effective spray coating technique on transparent conducting oxide coated substrates. The electro-optical properties of PProDOT-Hx(2) films were studied by UV-Vis spectroscopy that shows the color contrast about 45% with coloration efficiency of approximate to 185cm(2)/C. The electrochemical properties of PProDOT-Hx(2) films were studied by cyclic voltammetry and AC impedance techniques. The cyclic voltammogram shows that redox reaction of films are diffusion controlled and ions transportation will be faster on the polymer film at higher scan rate. Impedance spectra indicate that polymer films are showing interface charge transfer process as well as capacitive behavior between the electrode and electrolyte. The XRD of the PProDOT-Hx(2) thin films revealed that the films are in amorphous nature, which accelerates the transportation of ions during redox process.
Resumo:
Este trabalho apresenta o desenvolvimento de sistemas inteligentes aplicados ao monitoramento de estruturas aeronáuticas abordando dois modelos distintos: o primeiro é a análise e classificação de imagens de ultrassom de estruturas aeronáuticas com objetivo de apoiar decisões em reparo de estruturas aeronáuticas. Foi definido como escopo do trabalho uma seção transversal da asa da aeronave modelo Boeing 707. Após a remoção de material superficial em áreas comprometidas por corrosão, é realizada a medição da espessura ao longo da área da peça. Com base nestas medições, a Engenharia realiza a análise estrutural, observando os limites determinados pelo manual de manutenção e determina a necessidade ou não de reparo. O segundo modelo compreende o método de impedância eletromecânica. É proposto o desenvolvimento de um sistema de monitoramento de baixo custo aplicado em uma barra de alumínio aeronáutico com 10 posições de fixação de porcas e parafusos. O objetivo do sistema é avaliar, a partir das curvas de impedância extraídas do transdutor PZT fixado na barra, sua capacidade de classificar a existência ou não de um dano na estrutura e, em caso de existência do dano, indicar sua localização e seu grau de severidade. Foram utilizados os seguintes classificadores neste trabalho: máquina de vetor de suporte, redes neurais artificiais e K vizinhos mais próximos.
Resumo:
Objetivo: Recientemente, se han propuesto varios dispositivos de impedancia bioeléctrica (BIA) para la estimación rápida de la grasa corporal. Sin embargo, no han sido publicadas referencias de grasa corporal para niños y adolescentes en población Colombiana. El objetivo de este estudio fue establecer percentiles de grasa corporal por BIA en niños y adolescentes de Bogotá, Colombia de entre 9 y 17.9 años, pertenecientes al estudio FUPRECOL. Métodos: Estudio descriptivo y transversal, realizado en 2.526 niños y 3.324 adolescentes de entre 9 y 17.9 años de edad, pertenecientes a instituciones educativas oficiales de Bogotá, Colombia. El porcentaje de grasa corporal fue medido con Tanita® Analizador de Composición Corporal (Modelo BF-689), según edad y sexo. Se tomaron medidas de peso, talla, circunferencia de cintura, circunferencia de cadera y estado de maduración sexual por auto-reporte. Se calcularon los percentiles (P3, P10, P25, P50, P75, P90 y P97) y curvas centiles por el método LMS según sexo y edad y se realizó una comparación entre los valores de la CC observados con estándares internacionales. Resultados: Se presentan valores de porcentaje de grasa corporal y las curvas de percentiles. En la mayoría de los grupos etáreos la grasa corporal de las chicas fue mayor a la de los chicos. Sujetos cuyo porcentaje de grasa corporal estaba por encima del percentil 90 de la distribución estándar normal se consideró que tenían un elevado riesgo cardiovascular (chicos desde 23,4-28,3 y chicas desde 31,0-34,1). En general, nuestros porcentajes de grasa corporal fueron inferiores a los valores de Turquía, Alemania, Grecia, España y Reino Unido. Conclusiones: Se presentan percentiles del porcentaje de grasa por BIA según edad y sexo que podrán ser usados de referencia en la evaluación del estado nutricional y en la predicción del riesgo cardiovascular desde edades tempranas.
Resumo:
Estudou-se o comportamento eletroquímico do ferro em solução aquosa de acetato de sódio 1M em valores de pH próximos a neutralidade. Foram utilizadas diferentes técnicas de pertubação de potencial, quais sejam a voltametria cíclica e a impedância. Os ensaios foram realizados com eletrodos rotatórios de disco e eletrodos rotatórios de disco e anel. Observou-se o papel preponderante da concentração de acetato na dissolução do ferro que aliado ao pH da solução são os fatores determinantes da cinética deste processo. Evidenciou-se a ocorrência de reações consecutivas e paralelas neste estudo. O mecanismo catalítico presente na dissolução do ferro em meio de acetato cresce de importância a medida que os potenciais se tornam mais anódicos. E proposto que o mecanismo reacional apresenta quatro espécies adsorvidas,quais sejam: [FeOHAc]-ada, FeOHada [Fe(OH)2Ac]-ada e [Fe(OH)sAc]-2ada,sendo esta última a espécie precursora da passivação.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents a new approach for damage detection in Structural Health Monitoring (SHM) systems, which is based on the Electromechanical Impedance (EMI) principle and Autoregressive (AR) models. Typical applications of EMI in SHM are based on computing the Frequency Response Function (FRF). In this work the procedure is based on the EMI principle but the results are determined through the coefficients of AR models, which are computed from the time response of PZT transducers bonded to the monitored structure, and acting as actuator and sensors at the same time. The procedure is based on exciting the PZT transducers using a wide band chirp signal and getting its time response. The AR models are obtained in both healthy and damaged conditions and used to compute statistics indexes. Practical tests were carried out in an aluminum plate and the results have demonstrated the effectiveness of the proposed method. © 2012 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)