907 resultados para Electricity in dentistry


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dental ceramics are presented within a simplifying framework allowing for facile understanding of their development, composition and indications. Engineering assessments of clinical function are dealt with and literature is reviewed on the clinical behaviour of all-ceramic systems. Practical aspects are presented regarding the choice and use of dental ceramics to maximize aesthetics and durability, emphasizing what we know and how we know it.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although visualization in the field of dentistry has some of the same requirements as the medicine field, the differences in goal demand specific approaches. This paper reports on the implementation of two fundamentally different approaches to reconstruction of structures from planar cross sections and their application to dentistry data. One of the approaches was an implementation of a distance-based sampling technique, and the other is a new algorithm, based on the Delaunay triangulation. Both were tested using contour data of teeth and the results are compared here in the light of the target applications, which are teaching and training dentistry, as well as simulation of dental procedures and illnesses. Widely mentioned problems encountered in local reconstruction methods such as marching cubes for these cases are clearly illustrated in this paper, and a very satisfactory alternative is given. © 2000 SPIE and IS&T.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Titanium is a metallic element known by several attractive characteristics, such as biocompatibility, excellent corrosion resistance and high mechanical resistance. It is widely used in Dentistry, with high success rates, providing a favorable biological response when in contact with live tissues. Therefore, the objective of this study was to describe the different uses of titanium in Dentistry, reviewing its historical development and discoursing about its state of art and future perspective of its utilization. A search in the MEDLINE/PubMed database was performed using the terms 'titanium', 'dentistry' and 'implants'. The title and abstract of articles were read, and after this first screening 20 articles were selected and their full-texts were downloaded. Additional text books and manual search of reference lists within selected articles were included. Correlated literature showed that titanium is the most used metal in Implantology for manufacturing osseointegrated implants and their systems, with a totally consolidated utilization. Moreover, titanium can be also employed in prosthodontics to obtain frameworks. However, problems related to its machining, casting, welding and ceramic application for dental prosthesis are still limiting its use. In Endodontics, titanium has been used in association to nickel for manufacturing rotatory instruments, providing a higher resistance to deformation. However, although the different possibilities of using titanium in modern Dentistry, its use for prostheses frameworks still needs technological improvements in order to surpass its limitations. © 2012 Indian Prosthodontic Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Reduced surface tension of liquids results in higher surface wetting ability and diffusivity by the substrate. Objectives. The objective of this study was to evaluate the influence of the Grander Technology in reducing the surface tension of adhesive systems. Methods. Two adhesive systems (self-etch and total-etch) were modified by physical contact with the Grander system Flexible unit to revitalize water, for 48 h. Surface tension of adhesive systems and water in normal and grander-modified conditions was measured with a goniometer. Results. The results showed a reduction of surface tension for all conditions grander-modified between 3-15%. Conclusions. Grander Technology was effective in reducing the surface tension of the Single Bond and Clearfil SE Bond adhesive systems. Clinical significance. Grander technology was employed to restructure the molecular structure of water-based adhesive systems, which can increase their wetness capacity and therefore ensure a greater diffusibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper analyses the scientific collaboration network formed by the Brazilian universities that investigate in dentistry area. The constructed network is based on the published documents in the Scopus (Elsevier) database covering a period of 10 (ten) years. It is used social network analysis as the best methodological approach to visualize the capacity for collaboration, dissemination and transmission of new knowledge among universities. Cohesion and density of the collaboration network is analyzed, as well as the centrality of the universities as key-actors and the occurrence of subgroups within the network. Data were analyzed using the software UCINET and NetDraw. The number of documents published by each university was used as an indicator of its scientific production.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction and Objective: Photoelasticity consists of an experimental technique of stress analysis. This technique is very used in most different areas including Dentistry. This literature review presents the several applications of photoelastic technique in Dentistry the several applications of photoelastic technique in Dentistry as well as its advantages and disadvantages. Literature review: Based on this method of analysis, it is possible the verification of the stress distribution and deformation in structures with complex geometry as maxilla and mandible. It can be used to evaluate the distribution of stress on several types of prosthesis as removable partial denture systems with different retention systems, conventional implant prosthesis, overdentures and Brånemark protocols. Moreover, photoelasticity can be used to assess the stress generated by various by various orthodontic movements, different orthodontic systems and different materials (orthodontic wires). In addition, it is used to analyze different defects of maxillectomy, splint types on traumatized tooth and post-core restoration methods. This technique can also be used to assess dental instruments such as evaluation of different designs of periodontal probe. Conclusion: The photoelastic analysis has been a technique of great importance in health area studies, more specifically in Dentistry. Based on this method of analysis, it is possible to measure the stress distribution and deformation in structures with complex geometry as maxilla and mandible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The finite element method (FEM) involves a series of computational procedures to calculate the stress in each element, which performs a model solution. Such a structural analysis allows the determination of stress resulting from external force, pressure, thermal change, and other factors. This method is extremely useful for indicating mechanical aspects of biomaterials and human tissues that can hardly be measured in vivo. The results obtained can then be studied using visualization software within the FEM environment to view a variety of parameters, and to fully identify implications of the analysis. Objective: An overview to show application of FEM in dentistry was undertaken. Literature review: This paper shows the basic concept, advances, advantages, limitations and applications of finite element method (FEM) in dentistry. Conclusion: It is extremely important to verify what the purpose of the study is in order to correctly apply FEM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The finite element method (FEM) involves a series of computational procedures to calculate the stress in each element, which performs a model solution. Such a structural analysis allows the determination of stress resulting from external force, pressure, thermal change, and other factors. This method is extremely useful for indicating mechanical aspects of biomaterials and human tissues that can hardly be measured in vivo. The results obtained can then be studied using visualization software within the FEM environment to view a variety of parameters, and to fully identify implications of the analysis. Objective: An overview to show application of FEM in dentistry was undertaken. Literature review: This paper shows the basic concept, advances, advantages, limitations and applications of finite element method (FEM) in dentistry. Conclusion: It is extremely important to verify what the purpose of the study is in order to correctly apply FEM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to estimate the alcoholic beverage consumption among undergraduate students of a Dentistry Course and compare the effectiveness of screening methods for the detection of binge drinking. A total of 284 undergraduate students participated in the research. We used the full AUDIT and their reduced forms (AUDIT-3 and AUDIT-C). In addition, a ROC curve was created and its area was calculated. Of the students, 91.0% and 90.6% of the male and female genders, respectively, reported alcohol beverage consumption. Bing-drinking behavior occurred in 69.2% of the men and in 52.4% of the women. The 3 methods showed good discriminatory ability. For the women, there was a significant difference between the AUDIT-3 and AUDIT-C. Both the complete version of AUDIT and its reduced forms presented good discriminatory ability

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In laboratory tests, just following the manufacturer’s instructions of materials or equipments may not be enough to obtain reliable data. Thus, intra and inter-examiners studies may be required. The aim of this study was to illustrate the application of the Intraclass Correlation Coefficient (r) in a study related to the color changing and hardness of composite resin conducted by two examiners. The color and hardness of 10 specimens of composite resin were evaluated by a colorimetric spectrophotometer and hardness tester, respectively, at two different times. Two trained examiners performed two measurements with an interval of one week. Specimens were stored in artificial saliva at 37±1ºC for 7 days. The Intraclass Correlation was used for analysis of intra and inter-examiner reproducibility. The intra-examiner reproducibility was 0.79, 0.44 and 0.76 for L, a and b color coordinates for the examiner 1 and 0.84, 0.23, 0.21 for examiner 2. For hardness, r-values were 0.00 and 0.23 for the examiner 1 and 2, respectively, showing unsatisfactory agreement on color and hardness evaluation for both examiners. It was noted that only the observation of protocol for use of equipment and examiners training were not sufficient to collect reliable information. Thus, adjustments in the experimental protocol were made and devices were produced to standardize the measurements. The reproducibility study was performed again. For examiner 1, values as 0.90, 0.59 and 0.79 were verified for L, a and b coordinates and, for examiner 2 were obtained values of 0.90, 0.75, 0.95. In relation to hardness, r-values of 0.75 and 0.71 were obtained for examiners 1 and 2, respectively. The inter-examiner reproducibility was 0.86, 0.87, 0.91 for L, a and b coordinates and 0.79 for hardness. It was concluded that intra and inter-examiner calibration is essential for obtaining quality measurements in laboratory tests.