892 resultados para Electricity Network Distribution Wastes


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Power systems are planed and operated according to the optimization of the available resources. Traditionally these tasks were mostly undertaken in a centralized way which is no longer adequate in a competitive environment. Demand response can play a very relevant role in this context but adequate tools to negotiate this kind of resources are required. This paper presents an approach to deal with these issues, by using a multi-agent simulator able to model demand side players and simulate their strategic behavior. The paper includes an illustrative case study that considers an incident situation. The distribution company is able to reduce load curtailment due to load flexibility contracts previously established with demand side players.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Power systems operation in a liberalized environment requires that market players have access to adequate decision support tool, allowing them to consider all the business opportunities and take strategic decisions. Ancillary services represent a good negotiation opportunity that must be considered by market players. For this, decision support tools must include ancillary market simulation. This paper deals with ancillary services negotiation in electricity markets. The proposed concepts and methodologies are implemented in MASCEM, a multi-agent based electricity market simulator. A test case concerning the dispatch of ancillary services using two different methods (Linear Programming and Genetic Algorithm approaches) is included in the paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electricity market players operating in a liberalized environment requires access to an adequate decision support tool, allowing them to consider all the business opportunities and take strategic decisions. Ancillary services represent a good negotiation opportunity that must be considered by market players. For this, decision support tool must include ancillary market simulation. This paper proposes two different methods (Linear Programming and Genetic Algorithm approaches) for ancillary services dispatch. The methodologies are implemented in MASCEM, a multi-agent based electricity market simulator. A test case based on California Independent System Operator (CAISO) data concerning the dispatch of Regulation Down, Regulation Up, Spinning Reserve and Non-Spinning Reserve services is included in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Almost all the electricity currently produced in the UK is generated as part of a centralised power system designed around large fossil fuel or nuclear power stations. This power system is robust and reliable but the efficiency of power generation is low, resulting in large quantities of waste heat. The principal aim of this paper is to investigate an alternative concept: the energy production by small scale generators in close proximity to the energy users, integrated into microgrids. Microgrids—de-centralised electricity generation combined with on-site production of heat—bear the promise of substantial environmental benefits, brought about by a higher energy efficiency and by facilitating the integration of renewable sources such as photovoltaic arrays or wind turbines. By virtue of good match between generation and load, microgrids have a low impact on the electricity network, despite a potentially significant level of generation by intermittent energy sources. The paper discusses the technical and economic issues associated with this novel concept, giving an overview of the generator technologies, the current regulatory framework in the UK, and the barriers that have to be overcome if microgrids are to make a major contribution to the UK energy supply. The focus of this study is a microgrid of domestic users powered by small Combined Heat and Power generators and photovoltaics. Focusing on the energy balance between the generation and load, it is found that the optimum combination of the generators in the microgrid- consisting of around 1.4 kWp PV array per household and 45% household ownership of micro-CHP generators- will maintain energy balance on a yearly basis if supplemented by energy storage of 2.7 kWh per household. We find that there is no fundamental technological reason why microgrids cannot contribute an appreciable part of the UK energy demand. Indeed, an estimate of cost indicates that the microgrids considered in this study would supply electricity at a cost comparable with the present electricity supply if the current support mechanisms for photovoltaics were maintained. Combining photovoltaics and micro-CHP and a small battery requirement gives a microgrid that is independent of the national electricity network. In the short term, this has particular benefits for remote communities but more wide-ranging possibilities open up in the medium to long term. Microgrids could meet the need to replace current generation nuclear and coal fired power stations, greatly reducing the demand on the transmission and distribution network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sanitation companies from Brazil has a great challenge for the XXI century: seek to mitigate the rate of physical waste (water, chemicals and electricity) and financial waste caused by inefficient operating systems drinking water supply, considering that currently we already face, in some cases, the scarcity of water resources. The supply systems are increasingly complex as they seek to minimize waste and at the same time better serve the growing number of users. However, this technological change is to reduce the complexity of the challenges posed by the need to include users with higher quality and efficiency in services. A major challenge for companies of water supplies is to provide a good quality service contemplating reducing expenditure on electricity. In this situation we developed a research by a method that seeks to control the pressure of the distribution systems that do not have the tank in your setup and the water comes out of the well directly to the distribution system. The method of pressure control (intelligent control) uses fuzzy logic to eliminate the waste of electricity and the leaks from the production of pumps that inject directly into the distribution system, which causes waste of energy when the consumption of households is reduced causing the saturation of the distribution system. This study was conducted at Green Club II condominium, located in the city of Parnamirim, state of Rio Grande do Norte, in order to study the pressure behavior of the output of the pump that injects water directly into the distribution system. The study was only possible because of the need we had to find a solution to some leaks in the existing distribution system and the extensions of the respective condominium residences, which sparked interest in developing a job in order to carry out the experiments contained in this research

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a heuristic constructive multi-start algorithm (HCMA) to distribution system restoration in real time considering distributed generators installed in the system. The problem is modeled as nonlinear mixed integer and considers the two main goals of the restoration of distribution networks: minimizing the number of consumers without power and the number of switching. The proposed algorithm is implemented in C++ programming language and tested using a large real-life distribution system. The results show that the proposed algorithm is able to provide a set of feasible and good quality solutions in a suitable time for the problem. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trigeneration systems have been used with advantage in the last years in distributed electricity generation systems as a function of a growth of natural gas pipeline network distribution system, tax incentives, and energy regulation policies. Typically, a trigeneration system is used to produce electrical power simultaneously with supplying heating and cooling load by recovering the combustion products thermal power content that otherwise would be driven to atmosphere. Concerning that, two small scale trigeneration plants have been tested for overall efficiency evaluation and operational comparison. The first system is based on a 30 kW (ISO) natural gas powered microturbine, and the second one uses a 26 kW natural gas powered internal combustion engine coupled to an electrical generator as a prime mover. The stack gases from both machines were directed to a 17.6 kW ammonia-water absorption refrigeration chiller for producing chilled water first and next to a water heat recovery boiler in order to produce hot water. Experimental results are presented along with relevant system operational parameters for appropriate operation including natural gas consumption, net electrical and thermal power production, i.e., hot and cold water production rates, primary energy saving index, and the energy utilization factor over total and partial electrical load operational conditions. (c) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the potential of pre-setting 11kV overhead line ratings over a time period of sufficient length to be useful to the real-time management of overhead lines. This forecast is based on short and long term freely available weather forecasts and is used to help investigate the potential for realising dynamic rating benefits on the electricity network. A comparison between the realisable benefits in ratings using this forecast data, over the period of a year has been undertaken.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lappeenrannan teknillinen yliopisto tutkii pientasajännitesähkön käyttöä. Yliopisto on rakennuttanut Järvi-Suomen Energia Oy:n ja Suur-Savon Sähkö Oy:n kanssa yhteistyössä kokeellisen pientasajännitesähköverkon, jolla pystytään tarjoamaan kenttäolosuhteet pienjännitetutkimukselle todellisilla asiakkailla ja todentaa LVDC-teknologiaa ja muita älykkään sähköverkon toimintoja kenttäolosuhteissa. Verkon tasajänniteyhteys on rakennettu 20 kV sähkönjakeluverkon ja neljän kuluttajan välille. 20 kV keskijännite suunnataan tasamuuntamolla ±750 V pientasajännitteeksi ja uudestaan 400/230 V vaihtojännitteeksi kuluttajien läheisyydessä. Tämän kandidaatintyön tarkoituksena on luoda yliopistolle tietokanta pientasajännitesähköverkosta kertyvälle tiedolle ja mittaustuloksille. Tietokanta nähtiin tarpeelliseksi luoda, jotta pienjänniteverkon mittaustuloksia pystytään myöhemmin tarkastelemaan yhdessä ja yhtenäisessä muodossa. Yhdeksi tutkimuskysymykseksi muodostui, kuinka järjestää ja visualisoida kaikki verkosta palvelimille kertyvä mittausdata. Työssä on huomioitu myös kolme tietokantaa mahdollisesti hyödyntävää käyttäjäryhmää: kotitalousasiakkaat, sähköverkkoyhtiöt ja tutkimuslaboratorio, sekä pohdittu tietokannan hyötyä ja merkitystä näille käyttäjille. Toiseksi tutkimuskysymykseksi muodostuikin, mikä kaikesta tietokantaan talletetusta datasta olisi oleellisen tärkeää ottaa talteen näiden asiakkaiden kannalta, ja kuinka nämä voisivat hakea tietoa tietokannasta. Työn tutkimusmenetelmät perustuvat jo valmiiksi olemassa olevaan mittausdataan. Työtä varten on käytetty sekä painettua että sähköisessä muodossa olevaa kirjallisuutta. Työn tuloksena on saatu luotua tietokanta MySQL Workbench -ohjelmistolla, sekä mittausdatan keräys- ja käsittelyohjelmat Python-ohjelmointikielellä. Lisäksi on luotu erillinen MATLAB-rajapinta tiedon visualisoimista varten, jolla havainnollistetaan kolmen asiakasryhmän mittausdataa. Tietokanta ja sen tiedon visualisointi antavat kuluttajalle mahdollisuuden ymmärtää paremmin omaa sähkönkäyttöään, sekä sähköverkkoyhtiöille ja tutkimuslaboratorioille muun muassa tietoa sähkön laadusta ja verkon kuormituksesta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The highly unstructured nature of coral reef environments makes them difficult for current robotic vehicles to efficiently navigate. Typical research and commercial platforms have limited autonomy within these environments and generally require tethers and significant external infrastructure. This paper outlines the development of a new robotic vehicle for underwater monitoring and surveying in highly unstructured environments and presents experimental results illustrating the vehicle’s performance. The hybrid AUV design developed by the CSIRO robotic reef monitoring team realises a compromise between endurance, manoeuvrability and functionality. The vehicle represents a new era in AUV design specifically focused at providing a truly low-cost research capability that will progress environmental monitoring through unaided navigation, cooperative robotics, sensor network distribution and data harvesting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A vast amount of research into autonomous underwater navigation has, and is, being conducted around the world. However, typical research and commercial platforms have limited autonomy and are generally unable to navigate efficiently within coral reef environments without tethers and significant external infrastructure. This paper outlines the development and presents experimental results into the performance evaluation of a new robotic vehicle for underwater monitoring and surveying in highly unstructured environments. The hybrid AUV design developed by the CSIRO robotic reef monitoring team realises a compromise between endurance, manoeuvrability and functionality. The vehicle represents a new era in AUV design specifically focused at providing a truly lowcost research capability that will progress environmental monitoring through unaided navigation, cooperative robotics, sensor network distribution and data harvesting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many researchers and industry observers claim that electric vehicles (EV) and plug-in hybrid electric vehicles (PHEV) could provide vehicle-to-grid (V2G) bulk energy and ancillary services to an electricity network. This work quantified the impact on various battery characteristics whilst providing such services. The sensitivity of the impact of V2G services on battery degradation was assessed for EV and PHEV for different battery capacities, charging regimes, and battery depth of discharge. Battery degradation was found to be most dependent on energy throughput for both the EV and PHEV powertrains, but was most sensitive to charging regime (for EVs) and battery capacity (for PHEVs). When providing ancillary services, battery degradation in both powertrains was most sensitive to individual vehicle battery depth of discharge. Degradation arising from both bulk energy and ancillary services could be minimised by reducing the battery capacity of the vehicle, restricting the number of hours connected and reducing the depth of discharge of each vehicle for ancillary services. Regardless, best case minimum impacts of providing V2G services are severe such as to require multiple battery pack replacements over the vehicle lifetime. © 2013 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the first phase of the redevelopment of the Electric Vehicle Scenario Simulator (EVeSSi) tool. A new methodology to generate traffic demand scenarios for the Simulation of Urban MObility (SUMO) tool for urban traffic simulation is described. This methodology is based on a Portugal census database to generate a synthetic population for a given area under study. A realistic case study of a Portuguese city, Vila Real, is assessed. For this area the road network was created along with a synthetic population and public transport. The traffic results were obtained and an electric buses fleet was evaluated assuming that the actual fleet would be replaced in a near future. The energy requirements to charge the electric fleet overnight were estimated in order to evaluate the impacts that it would cause in the local electricity network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Renewable energy resources, especially wind power, are expected to provide a considerable portion of the world energy requirements in the near future. Large-scale wind power penetration impacts the electricity industry in many aspects and raises a number of technical challenges for the electricity network. A day-ahead network-constrained market clearing formulation is proposed which considers demand side resources. The proposed approach can provide flexible load profile and reduce the need for ramp up/down services by the conventional generators. This method can potentially facilitate a large penetration of wind power by shifting the wind power generation from the off-peak periods to the high-peak hours. The validity of the proposed approach has been verified using the IEEE 30 bus and 57 bus test systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A produção de biogás por meio de biodigestão anaeróbia representa um avanço para equacionar o problema dos dejetos produzidos pela suinocultura e disponibilidade de energia no meio rural. Este trabalho teve como objetivo estimar a viabilidade econômica de um sistema biointegrado para geração de eletricidade a partir do aproveitamento de dejetos de suínos. Os dados para este estudo foram coletados em uma agroindústria, onde são realizadas diversas atividades agrícolas; entretanto, a suinocultura foi selecionada para o processo de análise de biodigestão anaeróbia, pelo fato de gerar uma grande quantidade de dejetos, com dificuldade de disposição no meio ambiente, configurando um estudo de caso. O biodigestor analisado é um modelo tubular contínuo, com calha de água em alvenaria e com uma manta plástica como gasômetro, onde são depositados diariamente os dejetos de 2.300 suínos em fase de terminação. O investimento inicial para implantação foi estimado em R$ 51.537,17, e os custos anuais do sistema foram de R$ 5.708,20 com manutenção, R$ 4.390,40 com depreciação e R$ 1.366,77 com juros. Concluiu-se que o sistema de produção de biogás é viável do ponto de vista econômico, se o consumo de energia elétrica for de 35 kWh por dia, em média, onde o valor presente líquido (VLP) é de R$ 9.494,90, e a taxa interna de retorno (TIR) é de 9,34% ao ano.