940 resultados para Electrical-stimulation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use, manipulation and application of electrical currents, as a controlled interference mechanism in the human body system, is currently a strong source of motivation to researchers in areas such as clinical, sports, neuroscience, amongst others. In electrical stimulation (ES), the current applied to tissue is traditionally controlled concerning stimulation amplitude, frequency and pulse-width. The main drawbacks of the transcutaneous ES are the rapid fatigue induction and the high discomfort induced by the non-selective activation of nervous fibers. There are, however, electrophysiological parameters whose response, like the response to different stimulation waveforms, polarity or a personalized charge control, is still unknown. The study of the following questions is of great importance: What is the physiological effect of the electric pulse parametrization concerning charge, waveform and polarity? Does the effect change with the clinical condition of the subjects? The parametrization influence on muscle recruitment can retard fatigue onset? Can parametrization enable fiber selectivity, optimizing the motor fibers recruitment rather than the nervous fibers, reducing contraction discomfort? Current hardware solutions lack flexibility at the level of stimulation control and physiological response assessment. To answer these questions, a miniaturized, portable and wireless controlled device with ES functions and full integration with a generic biosignals acquisition platform has been created. Hardware was also developed to provide complete freedom for controlling the applied current with respect to the waveform, polarity, frequency, amplitude, pulse-width and duration. The impact of the methodologies developed is successfully applied and evaluated in the contexts of fundamental electrophysiology, psycho-motor rehabilitation and neuromuscular disorders diagnosis. This PhD project was carried out in the Physics Department of Faculty of Sciences and Technology (FCT-UNL), in straight collaboration with PLUX - Wireless Biosignals S.A. company and co-funded by the Foundation for Science and Technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An indoor rowing machine has been modified for functional electrical stimulation (FES) assisted rowing exercise in paraplegia. To perform the rowing manoeuvre successfully, however, the voluntarily controlled upper body movements must be co-ordinated with the movements of the electrically stimulated paralysed legs. To achieve such co-ordination, an automatic FES controller was developed that employs two levels of hierarchy. At the upper level, a finite state controller identifies the state or phase of the rowing cycle and activates the appropriate lower-level controller, in which electrical stimulation to the paralysed leg muscles is applied with reference to switching curves representing the desired seat velocity as a function of the seat position. In a pilot study, the hierarchical control of FES rowing was shown to be intuitive, reliable and easy to use. Compared with open-loop control of stimulation, all three variants of the closed-loop switching curve controllers used less muscle stimulation per rowing cycle (73% of the open-loop control on average). Further, the closed-loop controller that used switching curves derived from normal rowing kinematics used the lowest muscle stimulation (65% of the open-loop control) and was the most convenient to use for the client.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. Theoretic modeling and experimental studies suggest that functional electrical stimulation (FES) can improve trunk balance in spinal cord injured subjects. This can have a positive impact on daily life, increasing the volume of bimanual workspace, improving sitting posture, and wheelchair propulsion. A closed loop controller for the stimulation is desirable, as it can potentially decrease muscle fatigue and offer better rejection to disturbances. This paper proposes a biomechanical model of the human trunk, and a procedure for its identification, to be used for the future development of FES controllers. The advantage over previous models resides in the simplicity of the solution proposed, which makes it possible to identify the model just before a stimulation session ( taking into account the variability of the muscle response to the FES). Materials and Methods. The structure of the model is based on previous research on FES and muscle physiology. Some details could not be inferred from previous studies, and were determined from experimental data. Experiments with a paraplegic volunteer were conducted in order to measure the moments exerted by the trunk-passive tissues and artificially stimulated muscles. Data for model identification and validation also were collected. Results. Using the proposed structure and identification procedure, the model could adequately reproduce the moments exerted during the experiments. The study reveals that the stimulated trunk extensors can exert maximal moment when the trunk is in the upright position. In contrast, previous studies show that able-bodied subjects can exert maximal trunk extension when flexed forward. Conclusions. The proposed model and identification procedure are a successful first step toward the development of a model-based controller for trunk FES. The model also gives information on the trunk in unique conditions, normally not observable in able-bodied subjects (ie, subject only to extensor muscles contraction).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Paraplegic subjects lack trunk stability due to the loss of voluntary muscle control.This leads to a restriction of the volume of bi-manual workspace available,and hence has a detrimental impact on activities of daily living. Electrical Stimulation of paralysed muscles can be used to stabilize the trunk, but has never been applied in closed loop for this purpose. This paper describes the development of two closed loop controllers(PID and LQR),and their experimental evaluation on a human subject. Advantages and disadvantages of the two are discussed,considering a potential use of this technology during daily activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: Changes in skeletal muscle morphology and metabolism are associated with limited functional capacity in heart failure, which can be attenuated by neuromuscular electrical stimulation (ES). The purpose of the present study was to analyse the effects of ES upon GLUT-4 protein content, fibre structure and vessel density of the skeletal muscle in a rat model of HF subsequent to myocardial infarction. Methods: Forty-four male Wistar rats were assigned to one of four groups: sham (S), sham submitted to ES (S+ES), heart failure (HF) and heart failure submitted to ES (HF+ES). The rats in the ES groups were submitted to ES of the left leg during 20 days (2.5 kHz, once a day, 30 min, duty cycle 50%- 15 s contraction/15 s rest). After this period, the left tibialis anterior muscle was collected from all the rats for analysis. Results: HF+ES rats showed lower values of lung congestion when compared with HF rats (P = 0.0001). Although muscle weight was lower in HF rats than in the S group, thus indicating hypotrophy, 20 days of ES led to their recovery (P < 0.0001). In both groups submitted to ES, there was an increase in muscle vessel density (P < 0.04). Additionally, heart failure determined a 49% reduction in GLUT-4 protein content (P < 0.03), which was recovered by ES (P < 0.01). Conclusion: In heart failure, ES improves morphological changes and raises GLUT-4 content in skeletal muscle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim. To verify the muscular force and resistance to the movement of the flexor and extensor muscles of the knee of patients with spasticity after treatment with neuromuscular electrical stimulation (NMES) and isotonic exercises. Patients and methods. The patients this study were divided into group I (NMES) and group 2 (isotonic exercises). Their muscular torque and resistance to the movement of the flexor and extensor knee muscles were measured by the isokinetic dynamometer and the degree of spasticity by the modified Ashworth scale before and after ten sessions. Results. Alterations in the scores of the modified Ashworth scale were not observed. An increase in the flexor torque in group 1 (p = 0.041) and in group 2 (p = 0.001) was verified. In the passive mode, group 1 presented a reduction of resistance to the flexion movement (p = 0.026), while in group 2, a reduction of resistance to both the flexion (p = 0,029) and extension movements (p = 0.019) was verified. Conclusions. The two therapeutical resources had their efficiency proven only for the increase of the force of the flexor muscles. The resistance to movement, the isotonic exercises were more effective because they promoted a reduction in the resistance of the flexor and extensor knee muscles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Acupuncture is commonly used to reduce pain during labour despite contradictory results. The aim of this study is to evaluate the effectiveness of acupuncture with manual stimulation and acupuncture with combined manual and electrical stimulation (electro-acupuncture) compared with standard care in reducing labour pain. Our hypothesis was that both acupuncture stimulation techniques were more effective than standard care, and that electro-acupuncture was most effective.  Methods: A longitudinal randomised controlled trial. The recruitment of participants took place at the admission to the labour ward between November 2008 and October 2011 at two Swedish hospitals. 303 nulliparous women with normal pregnancies were randomised to: 40 minutes of manual acupuncture (MA), electro-acupuncture (EA), or standard care without acupuncture (SC). Primary outcome: labour pain, assessed by Visual Analogue Scale (VAS). Secondary outcomes: relaxation, use of obstetric pain relief during labour and post-partum assessments of labour pain. The sample size calculation was based on the primary outcome and a difference of 15 mm on VAS was regarded as clinically relevant, this gave 101 in each group, including a total of 303 women.  Results: Mean estimated pain scores on VAS (SC: 69.0, MA: 66.4 and EA: 68.5), adjusted for: treatment, age, education, and time from baseline, with no interactions did not differ between the groups (SC vs MA: mean difference 2.6, 95% confidence interval [CI] -1.7-6.9 and SC vs EA: mean difference 0.6 [95% CI] -3.6-4.8). Fewer number of women in the EA group used epidural analgesia (46%) than women in the MA group (61%) and SC group (70%) (EA vs SC: odds ratio [OR] 0.35; [95% CI] 0.19-0.67).  Conclusions: Acupuncture does not reduce women's experience of labour pain, neither with manual stimulation nor with combined manual and electrical stimulation. However, fewer women in the EA group used epidural analgesia thus indicating that the effect of acupuncture with electrical stimulation may be underestimated. These findings were obtained in a context with free access to other forms of pain relief.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In a previous randomised controlled trial we showed that acupuncture with a combination of manual- and electrical stimulation (EA) did not affect the level of pain, as compared with acupuncture with manual stimulation (MA) and standard care (SC), but reduced the need for other forms of pain relief, including epidural analgesia. To dismiss an under-treatment of pain in the trial, we did a long-term follow up on the recollection of labour pain and the birth experience comparing acupuncture with manual stimulation, acupuncture with combined electrical and manual stimulation with standard care. Our hypothesis was that despite the lower frequency of use of other pain relief, women who had received EA would make similar retrospective assessments of labour pain and the birth experience 2 months after birth as women who received standard care (SC) or acupuncture with manual stimulation (MA). METHODS: Secondary analyses of data collected for a randomised controlled trial conducted at two delivery wards in Sweden. A total of 303 nulliparous women with normal pregnancies were randomised to: 40 min of MA or EA, or SC without acupuncture. Questionnaires were administered the day after partus and 2 months later. RESULTS: Two months postpartum, the mean recalled pain on the visual analogue scale (SC: 70.1, MA: 69.3 and EA: 68.7) did not differ between the groups (SC vs MA: adjusted mean difference 0.8, 95 % confidence interval [CI] -6.3 to 7.9 and SC vs EA: mean difference 1.3 CI 95 % -5.5 to 8.1). Positive birth experience (SC: 54.3 %, MA: 64.6 % and EA: 61.0 %) did not differ between the groups (SC vs MA: adjusted Odds Ratio [OR] 1.8, CI 95 % 0.9 to 3.7 and SC vs EA: OR 1.4 CI 95 % 0.7 to 2.6). CONCLUSIONS: Despite the lower use of other pain relief, women who received acupuncture with the combination of manual and electrical stimulation during labour made the same retrospective assessments of labour pain and birth experience 2 months postpartum as those who received acupuncture with manual stimulation or standard care. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01197950.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neuromuscular electrical stimulation (NMES) applied to the triceps surae muscle is claimed to be effective in improving gait in children with cerebral palsy. The main aim of this study was to determine the effect of NMES on the triceps surae muscle in improving the gait and function of children with cerebral palsy. Twelve children with spastic diplegia or hemiplegia were recruited and randomly assigned to the two experimental groups. The period of the study was 8 weeks (2-4-2 week design). The initial 2 weeks was the control period, in which usual treatment was given to both groups of patients with a pre- and post-treatment assessment. The middle 4 weeks was the experimental period, in which the Treadmill+NMES group received NMES plus treadmill walking training and the Treadmill group underwent treadmill walking training only. Assessment was performed at 2-week intervals. The final 2 weeks was the carryover period, in which treatment to be tested was stopped and reassessment performed again at the end of week 8. An additional treatment and post-treatment assessment were given at weeks 2, 4 and 6 to test for the immediate effect of treatment. Altogether, eight repeated measures with three-dimensional gait analysis and five clinical measurements using the gross motor function measure (GMFM) were performed. Kinetic changes in ankle moment quotient (AMQ) and ankle power quotient (APQ) were not significant either immediately or cumulatively in both groups. Improvement in trend was observed in both groups immediately but not cumulatively. Using the GMFM, functional changes were detected in standing (GMST, p < 0.001) and in walking (GMWK, p = 0.003) using a 'time' comparison. Significant interaction was also detected in GMWK using 'treatment by time' (p = 0.035). The difference between the two groups was not significant on 'treatment' comparison of both GMST and GMWK. Both groups showed improvement in GMST and GMWK cumulatively but there was no difference between the two groups. The effects in both groups could be carried over to 2 weeks after interventions stopped. Both the Treadmill+NMES and Treadmill groups showed improvement in functional outcomes. The trend in the changes of the GMFM score suggested that improvements were greater in the Treadmill+NMES group. There was also a trend showing some immediate improvement in AMQ and APQ.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, nanostructured conductive platforms synthesized from aligned multiwalled carbon nanotubes and polypyrrole are investigated as myo-regenerative scaffolds. Myotube formation follows a linear path on the platforms coinciding with extent of nanotopography. In addition, electrical stimulation enhances myo-nuclear number and differentiation. These studies demonstrate that conductive polymer platforms can be used to influence muscle cell behaviour through nanostructure and electrical stimulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To evaluate the presence of fungi on contact electrodes and ultrasound transducers from physiotherapy clinics.Design Quantitative study conducted at the Laboratory of Microbiology and Immunology, Faculty of Health Sciences and Technology of Piaui - NOVAFAPI, Teresina, Brazil.Setting Sample collection was performed in 10 clinics ( 20 ultrasound transducers and 20 contact electrodes).Main outcome measures Swabs were soaked with saline solution, inoculated in culture and incubated for filamentous fungi and yeast growth.Results Fourteen taxons were identified: Acremomium hyalinulum (Sacc.), Aspergillus terreus, Candida albicans, Cladosporium cladosporioides, Cladosporium elatum, Cladosporium oxysporum, Cladosporium sphaerospermum, Cladosphialophora bantiana, Curvularia clavata, Curvularia senegalensis, Fusarium oxysporum, Penicillium decumbens, Scopulariopsis candida and Sporothrix schenckii. Aspergillus terreus, Cladosporium oxysporum, Sporothrix shenckii and Candida albicans were found most often on contact electrodes, and Penicillium decumbens and Cladosporium cladosporioides were found most often on ultrasound transducers.Conclusion Fungi were found on all of the contact electrodes and ultrasound transducers. Physiotherapy professionals need to improve the disinfection procedures for this equipment. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of intravaginal electrical stimulation (IES) on pelvic floor muscle (PFM) strength in patients with mixed urinary incontinence (MUI). Between January 2001 and February 2002, 40 MUI women (mean age: 48 years) were studied. Urge incontinence was the predominant symptom; 92.5% also presented mild stress urinary incontinence (SUI). Selection criteria were clinical history and urodynamics. Pre-treatment urodynamic study showed no statistical differences between the groups. Ten percent of the women in each group had involuntary detrusor contractions. Patients were randomly distributed, in a double-blind study, into two groups. Group G 1 (n=20), effective IES, and group G2 (n=20), sham IES, with follow-up at 1 month. The following parameters were studied: (1) clinical questionnaire, (2) examiner's evaluation of perineal muscle strength, (3) objective evaluation of perineal muscle by perineometry, (4) vaginal weight test, and (5) urodynamic study. The IES protocol consisted of three 20-min sessions per week over a 7-week period using a Dualpex Uro 996 at 4 Hz. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence, present in all patients before treatment, was reduced to 15% in G1 and 31.5% in G2 post-treatment. The subjective evaluation of PFM strength demonstrated a significant improvement in G1. Objective evaluation of PFM force by perineometer showed a significant improvement in maximum peak contraction post-treatment in both groups. In the vaginal weight test, there was a significant increase in average number of cone retentions post-treatment in both groups. With regard to satisfaction level, after treatment, 80% of the patients in G1 and 65% of the patients in G2 were satisfied. There was no statistically significant difference between the groups. There was a significant improvement in PFM strength from both effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy in treating MUI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background the aim of this study was to compare effective and sham intravaginal electrical stimulation (IES) in treating mixed urinary incontinence. Methods. Between January 2001 and February 2002, 40 women were randomly distributed, in a double-blind study, into two groups: group G1 (n = 20), effective IES, and group G2 (n = 20), sham IES, with follow up at one month. Different parameters was studied: 1. clinical questionnaire, 2. body mass index; 3. 60-min pad test; 4. urodynamic study. The protocol of IES consisted of three 20-min sessions per week over a seven-week period. The Dualpex Uro 996 used a frequency of 4 Hz. Results. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence was reduced to 15% in G1 and 31.5% in G2; there was no significant difference between the groups. In the analog wetness and discomfort sensation evaluations were reduced significantly in both groups. The pretreatment urodynamic study showed no statistical difference in urodynamic parameters between the groups. Ten percent of the women presented involuntary detrusor contractions. In the 60-min pad test, there was a significant reduction in both groups. In regards to satisfaction level, after treatment, 80% of G1 patients and 65% of G2 patients were satisfied. There was no statistically significant difference between the groups. Conclusion. Significant improvement was provided by effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy.