307 resultados para Elbow tendionitis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The loss of motor function at the elbow joint can result as a consequence of stroke. Stroke is a clinical illness resulting in long lasting neurological deficits often affecting somatosensory and motor cortices. More than half of those that recover from a stroke survive with disability in their upper arm and need rehabilitation therapy to help in regaining functions of daily living. In this paper, we demonstrated a prototype of a low-cost, ultra-light and wearable soft robotic assistive device that could aid administration of elbow motion therapies to stroke patients. In order to assist the rotation of the elbow joint, the soft modules which consist of soft wedge-like cellular units was inflated by air to produce torque at the elbow joint. Highly compliant rotation can be naturally realised by the elastic property of soft silicone and pneumatic control of air. Based on the direct visual-actuation control, a higher control loop utilised visual processing to apply positional control, the lower control loop was implemented by an electronic circuit to achieve the desired pressure of the soft modules by Pulse Width Modulation. To examine the functionality of the proposed soft modular system, we used an anatomical model of the upper limb and performed the experiments with healthy participants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose : This study measured observer variation in radiographic rating of elbow arthrosis.

Methods : Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint; grade 1, slight joint-space narrowing with minimum osteophyte formation; grade 2, moderate joint-space narrowing with moderate osteophyte formation; and grade 3, severe degenerative change with gross destruction of the joint). The kappa multirater measure (κ) was used to estimate reliability between observers, with 0 indicating no agreement above chance, and 1 indicating perfect agreement.

Results : There was fair agreement in arthrosis ratings between surgeons. Surgeons with more than 10 years of experience had greater agreement than did surgeons with less experience, and surgeons who treated more than 10 elbow fractures per year had better agreement than did those treating fewer fractures. In post hoc analyses, 2 simplified binary rating systems (eg, “none or mild” vs “moderate or severe” arthrosis) resulted in moderate agreement among observers.

Conclusions : The 4 grades of the Broberg and Morrey classification system have only fair interobserver reliability that is influenced by subspecialty and experience. Binary rating systems might be more reliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram estudados o arranjo e o diâmetro médio das fibrilas colágenas do ligamento colateral medial da articulação do cotovelo do cão, isolado ou associado ao ligamento oblíquo e tracionado até a ruptura. Dezoito articulações foram divididas em três grupos. O primeiro grupo teve o ligamento colateral medial coletado, mas não tracionado; o segundo grupo teve o ligamento colateral medial tracionado isoladamente; o terceiro grupo teve os ligamentos colateral medial e oblíquo tracionados associadamente. O ligamento colateral medial não submetido ao ensaio de tração apresentou um padrão ondulado das fibras colágenas, o qual não foi totalmente destruído quando foi tracionado, associado ao ligamento oblíquo, e perdeu totalmente o padrão reticular das fibras colágenas quando testado isoladamente. Quando o ligamento colateral medial foi submetido à tensão isoladamente, o diâmetro médio das fibrilas colágenas aumentou em relação ao grupo não submetido à tensão. Associado ao ligamento oblíquo, o diâmetro médio das fibrilas colágenas foi o maior na região de inserção e o menor na região média, em relação aos outros grupos. Concluiu-se que o ligamento oblíquo pode favorecer a integridade da região de inserção do ligamento colateral medial, aumentando a eficácia de sua reconstrução após a lesão.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the clinical and radiographic outcome in 8 dogs of surgical reduction of congenital humeroulnar luxation by using the transarticular pin. Five cases were bilateral and 3 were unilateral, for a total of 13 elbows. The treatment was performed in animals between 45 and 150 days of age. Articular stabilization was achieved by using a transarticular pin driven from the caudal aspect of the olecranon into the body of the humerus or into the distal condyle and distal metaphysis of the humerus. The follow-up period was between 1 and 19 months. There were 5 postsurgical reluxations, 3 related to the insertion of the pin into the humeral condyle and 3 related to the insertion into the humeral body. These animals needed further surgery. Six animals showed near normal return to limb function and 2 had lameness. We conclude that the use of the transarticular pin is an effective and simple method for the treatment of humeroulnar congenital elbow luxation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the oblique ligament mechanical contribution to the medial collateral ligament of the canine elbow joint. Fifteen dogs were used for the study of the failure load, displacement, and energy absorption of the medial collateral and oblique ligaments of the canine elbow joint, associate and separately in the joint. Medial collateral ligament failure load and energy absorption were significantly higher in relation to the isolated oblique ligament. When the ligaments were associated in the joint, they presented an increment in failure load, displacement and energy absorption in relation to the ligaments analyzed separately. It was concluded, therefore, that the oblique ligament could have an important paper in the stability of the canine elbow joint, as it favors the medial collateral ligament resistance to the tensile load, one of the main stabilizer of the elbow joint.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To verify the effects of resistance training at the electromyographic fatigue threshold (EMGFT) based on one-repetition maximum strength (1RM), heart rate (HR), rate of perceived exertion (PE) and endurance time (EndT). Methods. Nineteen subjects (training group [TG]: n = 10; control group [CG]: n = 9), performed 1-min bicep curl exercises sets at 25%, 30%, 35% and 40% 1RM. Electromyography (biceps brachii and brachiorradialis), HR and PE were registered. Biceps brachii EMGFT was used to create a load index for an eight-week resistance training programme (three sets until exhaustion/session, two sessions/week) for the TG. The CG only attended one session in the first week and another session in the last week of the eight-week training period for EndT measurement. EndT was determined from the number of repetitions of each of the three sets performed in the first and last training sessions. After training, 1RM, EMGFT, EndT, HR and PE at the different bicep curl load intensities were again measured for both groups. Results. Increases in 1RM (5.9%, p < 0.05) and EndT (> 60%, p < 0.001) after training were found. In addition, PE was reduced at all load intensities (p < 0.05), while no changes were found for HR and EMGFT after training. Conclusions. Strength-endurance training based on the EMGFT improved muscular endurance and also, to a lesser extent, muscular strength. Moreover, the reduced levels of physical exertion after training at the same intensity suggest that endurance training exercises may improve comfort while performing strength exercises.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The joint torque is an important variable related to children with cerebral palsy. The present study analyzed kinetic parameters during elbow flexion and extension movements in healthy and cerebral palsy children. Ten healthy and 10 cerebral palsy children participated of the study. An isokinetic dynamometer was used to measure the elbow mean peak torque, mean angle peak torque, coefficient of variation and acceleration during flexion and extension movements at different angular speeds. The mean peak torque on extension movement in healthy children group was significant higher compared to the cerebral palsy group. The coefficient of variation on both flexion and extension movements was significantly higher in cerebral palsy group. However there were significantly difference on both groups compared the lowest and highest velocities. Although the results showed no difference in flexor peak torque, the acceleration is significantly lower in lowest and highest angular velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To carry out an anatomical study of the medial collateral ligament, an important elbow stabilizer in different degrees of elbow flexion-extension. Methods: Forty elbows were dissected in order to analyze the functional behavior of the anterior, posterior and transverse ligament bands during valgus stress maneuvers of the elbow in different degrees of flexion and extension. Two groups were determined; in the group GPA the posterior band of the ligament was sectioned initially, then the articular capsule and finally the anterior band; in group GAP this order was reversed. Results: Instability was observed in GPA only in the third stage, when there was a greater mean elbow's opening during the flexion (between 50 degrees and 70 degrees); in GAP the instability was present since the first stage; the degrees of flexion with greater instability were the same as in group GPA. Conclusion: The anterior band of the medial collateral ligament of the elbow is the most important stabilizer of the elbow valgus instability, and its principal action occurs between 50 degrees and 70 degrees of elbow flexion. Level of Evidence III, Diagnostic Studies Investigating a diagnostic test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background Recent reviews have indicated that low level level laser therapy (LLLT) is ineffective in lateral elbow tendinopathy (LET) without assessing validity of treatment procedures and doses or the influence of prior steroid injections. Methods Systematic review with meta-analysis, with primary outcome measures of pain relief and/or global improvement and subgroup analyses of methodological quality, wavelengths and treatment procedures. Results 18 randomised placebo-controlled trials (RCTs) were identified with 13 RCTs (730 patients) meeting the criteria for meta-analysis. 12 RCTs satisfied half or more of the methodological criteria. Publication bias was detected by Egger's graphical test, which showed a negative direction of bias. Ten of the trials included patients with poor prognosis caused by failed steroid injections or other treatment failures, or long symptom duration or severe baseline pain. The weighted mean difference (WMD) for pain relief was 10.2 mm [95% CI: 3.0 to 17.5] and the RR for global improvement was 1.36 [1.16 to 1.60]. Trials which targeted acupuncture points reported negative results, as did trials with wavelengths 820, 830 and 1064 nm. In a subgroup of five trials with 904 nm lasers and one trial with 632 nm wavelength where the lateral elbow tendon insertions were directly irradiated, WMD for pain relief was 17.2 mm [95% CI: 8.5 to 25.9] and 14.0 mm [95% CI: 7.4 to 20.6] respectively, while RR for global pain improvement was only reported for 904 nm at 1.53 [95% CI: 1.28 to 1.83]. LLLT doses in this subgroup ranged between 0.5 and 7.2 Joules. Secondary outcome measures of painfree grip strength, pain pressure threshold, sick leave and follow-up data from 3 to 8 weeks after the end of treatment, showed consistently significant results in favour of the same LLLT subgroup (p < 0.02). No serious side-effects were reported. Conclusion LLLT administered with optimal doses of 904 nm and possibly 632 nm wavelengths directly to the lateral elbow tendon insertions, seem to offer short-term pain relief and less disability in LET, both alone and in conjunction with an exercise regimen. This finding contradicts the conclusions of previous reviews which failed to assess treatment procedures, wavelengths and optimal doses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate topographic and age-dependent adaptation of subchondral bone density in the elbow joints of healthy dogs by means of computed tomographic osteoabsorptiometry (CTOAM). Animals-42 elbow joints of 29 clinically normal dogs of various breeds and ages. PROCEDURES: Subchondral bone densities of the humeral, radial, and ulnar joint surfaces of the elbow relative to a water-hydroxyapatite phantom were assessed by means of CTOAM. Distribution patterns in juvenile, adult, and geriatric dogs (age, < 1 year, 1 to 8 years, and > 8 years, respectively) were determined and compared within and among groups. RESULTS: An area of increased subchondral bone density was detected in the humerus distomedially and cranially on the trochlea and in the olecranon fossa. The ulna had maximum bone densities on the anconeal and medial coronoid processes. Increased bone density was detected in the craniomedial region of the joint surface of the radius. A significant age-dependent increase in subchondral bone density was revealed in elbow joint surfaces of the radius, ulna, and humerus. Mean subchondral bone density of the radius was significantly less than that of the ulna in paired comparisons for all dogs combined and in adult and geriatric, but not juvenile, dog groups. CONCLUSIONS AND CLINICAL RELEVANCE: An age-dependent increase in subchondral bone density at the elbow joint was revealed. Maximal relative subchondral bone densities were detected consistently at the medial coronoid process and central aspect of the humeral trochlea, regions that are commonly affected in dogs with elbow dysplasia.