884 resultados para EYE IRRITATION TESTS


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Although free eye testing is available in the UK from a nation-wide network of optometrists, there is evidence of unrecognised, tractable vision loss amongst older people. A recent review identified this unmet need as a priority for further investigation, highlighting the need to understand public perceptions of eye services and barriers to service access and utilisation. This paper aims to identify risk factors for (1) having poor vision and (2) not having had an eyesight check among community-dwelling older people without an established ophthalmological diagnosis. METHODS Secondary analysis of self-reported data from the ProAge trial. 1792 people without a known ophthalmological diagnosis were recruited from three group practices in London. RESULTS Almost two in ten people in this population of older individuals without known ophthalmological diagnoses had self-reported vision loss, and more than a third of them had not had an eye test in the previous twelve months. In this sample, those with limited education, depressed mood, need for help with instrumental and basic activities of daily living (IADLs and BADLs), and subjective memory complaints were at increased risk of fair or poor self-reported vision. Individuals with basic education only were at increased risk for not having had an eye test in the previous 12 months (OR 1.52, 95% CI 1.17-1.98 p=0.002), as were those with no, or only one chronic condition (OR 1.850, 95% CI 1.382-2.477, p<0.001). CONCLUSIONS Self-reported poor vision in older people without ophthalmological diagnoses is associated with other functional losses, with no or only one chronic condition, and with depression. This pattern of disorders may be the basis for case finding in general practice. Low educational attainment is an independent determinant of not having had eye tests, as well as a factor associated with undiagnosed vision loss. There are other factors, not identified in this study, which determine uptake of eye testing in those with self-reported vision loss. Further exploration is needed to identify these factors and lead towards effective case finding.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Impairment of cognitive performance during and after high-altitude climbing has been described in numerous studies and has mostly been attributed to cerebral hypoxia and resulting functional and structural cerebral alterations. To investigate the hypothesis that high-altitude climbing leads to cognitive impairment, we used of neuropsychological tests and measurements of eye movement (EM) performance during different stimulus conditions. The study was conducted in 32 mountaineers participating in an expedition to Muztagh Ata (7,546 m). Neuropsychological tests comprised figural fluency, line bisection, letter and number cancellation, and a modified pegboard task. Saccadic performance was evaluated under three stimulus conditions with varying degrees of cortical involvement: visually guided pro- and anti-saccades, and visuo-visual interaction. Typical saccade parameters (latency, mean sequence, post-saccadic stability, and error rate) were computed off-line. Measurements were taken at a baseline level of 440 m and at altitudes of 4,497, 5,533, 6,265, and again at 440 m. All subjects reached 5,533 m, and 28 reached 6,265 m. The neuropsychological test results did not reveal any cognitive impairment. Complete eye movement recordings for all stimulus conditions were obtained in 24 subjects at baseline and at least two altitudes and in 10 subjects at baseline and all altitudes. Measurements of saccade performances showed no dependence on any altitude-related parameter and were well within normal limits. Our data indicates that acclimatized climbers do not seem to suffer from significant cognitive deficits during or after climbs to altitudes above 7,500 m. We demonstrated that investigation of EMs is feasible during high-altitude expeditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Approximately half of current contact lens wearers suffer from dryness and discomfort, particularly towards the end of the day. Contact lens practitioners have a number of dry eye tests available to help them to predict which of their patients may be at risk of contact lens drop out and advise them accordingly. This thesis set out to rationalize them to see if any are of more diagnostic significance than others. This doctorate has found: (1) The Keratograph, a device which permits an automated, examiner independent technique for measuring non invasive tear break up time (NITBUT) measured NITBUT consistently shorter than measurements recorded with the Tearscope. When measuring central corneal curvature the spherical equivalent power of the cornea was measured as being significantly flatter than with a validated automated keratometer. (2) Non-invasive and invasive tear break-up times significantly correlated to each other, but not the other tear metrics. Symptomology, assessed using the OSDI questionnaire, correlated more with those tests indicating possible damage to the ocular surface (including LWE, LIPCOF and conjunctival staining) than with tests of either tear volume or stability. Cluster analysis showed some statistically significant groups of patients with different sign and symptom profiles. The largest cluster demonstrated poor tear quality with both non-invasive and invasive tests, low tear volume and more symptoms. (3) Care should be taken in fitting patients new to contact lenses if they have a NITBUT less than 10s or an OSDI comfort rating greater than 4.2 as they are more likely to drop-out within the first 6 months. Cluster analysis was not found to be beneficial in predicting which patients will succeed with lenses and which will not. A combination of the OSDI questionnaire and a NITBUT measurement was most useful both in diagnosing dry eye and in predicting contact lens drop out.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Xylitol is a widely studied sugar with therapeutic properties and is effective against microorganisms. Despite a variety of toxicological data being available about this compound, dermal toxicological tests cannot be found. Here, the aim was to carry out in vivo assays to verify xylitol skin application safety. Primary dermal irritation studies were done with rabbits using 5 and 10% (w/w) xylitol, in either cream or gel form. Phototoxicity assays were also performed with guinea pigs, using only 10% (w/w) xylitol, in both forms. Primary dermal irritation studies revealed that xylitol topically used (5 and 10%) did not induce erythema or edema formation, but did show phototoxicity properties. Xylitol is an adequate alternative compound to be applied for skin disease control, since this application will be done together with sunscreen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to explore the clinical relevance of chronic exposure to ambient levels of traffic derived air pollution on the ocular surface. Methods: A panel study involving 55 volunteers was carried out in Sao Paulo, Brazil. We measured the mean individual levels of nitrogen dioxide (NO(2)) exposure for 7 days. All subjects answered the Ocular Symptom Disease Index (OSDI) and a symptoms inventory. Subsequently, subjects underwent Schirmer I test, biomicroscopy, vital staining and tear breakup time (TOUT) assessment. Subject`s mean daily exposure to NO(2) was categorized in quartiles. Statistical analysis was performed using one-way ANOVA, Tukey HSD and Chi-Square tests. Results: A dose-response pattern was detected between OSDI scores and NO(2) quartiles (p < 0.05). There was a significant association between NO(2) quartiles and reported ocular irritation (X(2) = 9.2, p < 0.05) and a significant negative association between TBUT and NO(2) exposure (p < 0.05, R = -0.316. Spearman`s correlation). There was a significant increase in the frequency of meibomitis in subjects exposed to higher levels of NO(2) (p < 0.05). Conclusions: Subjects exposed to higher levels of traffic derived air pollution reported more ocular discomfort symptoms and presented greater tear film instability, suggesting that the ocular discomfort symptoms and tear breakup time could be used as convenient bioindicators of the adverse health effects of traffic derived air pollution exposure. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aging of Portuguese population is characterized by an increase of individuals aged older than 65 years. Preventable visual loss in older persons is an important public health problem. Tests used for vision screening should have a high degree of diagnostic validity confirmed by means of clinical trials. The primary aim of a screening program is the early detection of visual diseases. Between 20% and 50% of older people in the UK have undetected reduced vision and in most cases is correctable. Elderly patients do not receive a systematic eye examination unless a problem arises with their glasses or suspicion vision loss. This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. Furthermore, it pretends to define the ability to find the subjects affected with vision loss as positive and the subjects not affected with the same disease as negative. The ideal vision screening method should have high sensitivity and specificity for early detection of risk factors. It should be also low cost and easy to implement in all geographic and socioeconomic regions. Sensitivity is the ability of an examination to identify the presence of a given disease and specificity is the ability of the examination to identify the absence of a given disease. It was not an aim of this study to detect abnormalities that affect visual acuity. The aim of this study was to find out what´s the best test for the identification of any vision loss.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de mestrado em Média Interativos

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently published guidelines��in the UK��relating to sight tests among people with dementia go some of the way to addressing the specific needs of this group. However, there is still a long way to go in terms of improving the provision of eye care services and optimising the visual health of this group.A��study, published by the Thomas Pocklington Trust,��which examines this subject - The development of professional guidelines for the eye examination of people with dementia - was presented at the first ever national “Dementia and Sight Loss conference” in London (1st December) - a forum where 100 dementia and sight loss professionals met to discuss ways to tackle the challenge of concurrent dementia and sight loss. The study, by researchers at the University of Bradford Schools of Optometry and Health Studies, reviewed procedures for sight tests and eye examinations among those with dementia. It found that policy and practice were hampered by a serious lack of basic research into concurrent dementia and sight loss and prompted recommendations which could lead to improved procedures, tools and techniques.Recommendations prompted by the study outline seven steps towards improving policy and practice:Conduct a systematic study of the availability and uptake of sight tests among people with dementia. Set up a website for people with dementia and their carers with information on how dementia affects eye health, and the importance of eye examinations. Develop education and training for optometrists and care home staff. Compile a list of optometrists experienced in providing eye care for people with dementia. Develop a template for recording the results of eye examinations in people with dementia – something which can be endorsed by professional bodies and made available to care homes. Measure the effectiveness of eye care, such as sight tests and cataract removals, on the quality of life of people with dementia. Research clinical testing methods so that guidelines can be strengthened. Measuring contrast sensitivity, for example, in someone with dementia could be vital as an inability to judge contrasts can make daily tasks impossible.To access the discussion paper please follow this link: The development of professional guidelines for the eye examination of people with dementia ��

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Studies assessing skin irritation to chemicals have traditionally used laboratory animals; however, such methods are questionable regarding their relevance for humans. New in vitro methods have been validated, such as the reconstructed human epidermis (RHE) model (Episkin®, Epiderm®). The comparison (accuracy) with in vivo results such as the 4-h human patch test (HPT) is 76% at best (Epiderm®). There is a need to develop an in vitro method that better simulates the anatomo-pathological changes encountered in vivo. To develop an in vitro method to determine skin irritation using human viable skin through histopathology, and compare the results of 4 tested substances to the main in vitro methods and in vivo animal method (Draize test). Human skin removed during surgery was dermatomed and mounted on an in vitro flow-through diffusion cell system. Ten chemicals with known non-irritant (heptylbutyrate, hexylsalicylate, butylmethacrylate, isoproturon, bentazon, DEHP and methylisothiazolinone (MI)) and irritant properties (folpet, 1-bromohexane and methylchloroisothiazolinone (MCI/MI)), a negative control (sodiumchloride) and a positive control (sodiumlaurylsulphate) were applied. The skin was exposed at least for 4h. Histopathology was performed to investigate irritation signs (spongiosis, necrosis, vacuolization). We obtained 100% accuracy with the HPT model; 75% with the RHE models and 50% with the Draize test for 4 tested substances. The coefficients of variation (CV) between our three test batches were <0.1, showing good reproducibility. Furthermore, we reported objectively histopathological irritation signs (irritation scale): strong (folpet), significant (1-bromohexane), slight (MCI/MI at 750/250ppm) and none (isoproturon, bentazon, DEHP and MI). This new in vitro test method presented effective results for the tested chemicals. It should be further validated using a greater number of substances; and tested in different laboratories in order to suitably evaluate reproducibility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. METHODS AND MATERIALS: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. RESULTS: Cross-validation revealed a dice similarity of 95% ± 2% for the sclera and cornea and 91% ± 2% for the lens. Overall, mean segmentation error was found to be 0.3 ± 0.1 mm. Average segmentation time was 14 ± 2 s on a standard personal computer. CONCLUSIONS: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The current study investigated cognitive resource allocation in discourse processing by means of pupil dilation and behavioral measures. Short question-answer dialogs were presented to listeners. Either the context question queried a new information focus in the successive answer, or else the context query was corrected in the answer sentence (correction information). The information foci contained in the answer sentences were either adequately highlighted by prosodic means or not. Participants had to judge the adequacy of the focus prosody with respect to the preceding context question. Prosodic judgment accuracy was higher in the conditions bearing adequate focus prosody than in the conditions with inadequate focus prosody. Latency to peak pupil dilation was longer when new information foci were perceived compared to correction foci. Moreover, for the peak dilation, an interaction of focus type and prosody was found. Post hoc statistical tests revealed that prosodically adequate correction focus positions were processed with smaller peak dilation in comparison to all other dialog conditions. Thus, pupil dilation and results of a principal component analysis suggest an interaction of focus type and focus prosody in discourse processing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Covert spatial attention produces biases in perceptual and neural responses in the absence of overt orienting movements. The neural mechanism that gives rise to these effects is poorly understood. Here we report the relation between fixational eye movements, namely eye vergence, and covert attention. Visual stimuli modulate the angle of eye vergence as a function of their ability to capture attention. This illustrates the relation between eye vergence and bottom-up attention. In visual and auditory cue/no-cue paradigms, the angle of vergence is greater in the cue condition than in the no-cue condition. This shows a top-down attention component. In conclusion, observations reveal a close link between covert attention and modulation in eye vergence during eye fixation. Our study suggests a basis for the use of eye vergence as a tool for measuring attention and may provide new insights into attention and perceptual disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La dermatite irritative est décrite comme une réaction réversible, non immunologique caractérisée par des lésions d'aspect très variable, allant de la simple rougeur jusqu'à la formation de bulles voire d'une nécrose, accompagnée de prurit ou d'une sensation de brûlure suite à I' application d'une substance chimique. Le teste de prédiction d'irritation cutanée est traditionnellement depuis les années 1940 le Test de Draize. Ce test consiste en l'application d'une substance chimique sur une peau rasée de lapin pendant 4h et de regarder à 24h si des signes cliniques d'irritations sont présents. Cette méthode critiquable autant d'un point de vue éthique que qualitative reste actuellement le teste le plus utilisé. Depuis le début des années 2000 de nouvelles méthodes in vitro se sont développées tel que le model d'épiderme humain recombiné (RHE). Il s agit d'une multicouche de kératinocyte bien différencié obtenu depuis une culture de don d'ovocyte. Cependant cette méthode en plus d'être très couteuse n'obtient au mieux que 76% de résultat similaire comparé au test in vivo humain. Il existe donc la nécessité de développer une nouvelle méthode in vitro qui simulerait encore mieux la réalité anatomique et physiologique retrouvée in vivo. Notre objectif a été de développer cette nouvelle méthode in vitro. Pour cela nous avons travaillé avec de la peau humaine directement prélevée après une abdominoplastie. Celle ci après préparation avec un dermatome, un couteau dont la lame est réglable pour découper l'épaisseur souhaitée de peau, est montée dans un système de diffusion cellulaire. La couche cornée est alors exposée de manière optimale à 1 ml de la substance chimique testée pendant 4h. L'échantillon de peau est alors fixé dans du formaldéhyde pour permettre la préparation de lames standards d'hématoxyline et éosine. L'irritation est alors investiguée selon des critères histopathologiques de spongioses, de nécroses et de vacuolisations cellulaires. Les résultats de ce.tte première batterie de testes sont plus que prometteurs. En effet, comparé au résultat in vivo, nous obtenons 100% de concordance pour les 4 même substances testes irritantes ou non irritantes, ce qui est supérieur au model d épiderme humain recombiné (76%). De plus le coefficient de variation entre les 3 différentes séries est inférieur à 0.1 ce qui montre une bonne reproductibilité dans un même laboratoire. Dans le futur cette méthode va devoir être testée avec un plus grand nombre de substances chimiques et sa reproductibilité évaluée dans différents laboratoires. Mais cette première evaluation, très encourageante, ouvre des pistes précieuses pour l'avenir des tests irritatifs.