959 resultados para Drop
Resumo:
The first larval instar has been identified as a critical stage for population mortality in Lepidoptera, yet due to the body size of these larvae, the factors that contribute to mortality under field conditions are still not clear. Dispersal behaviour has been suggested as a significant, but ignored factor contributing to mortality in first-instar lepidopteran larvae. The impact that leaving the host plant has on the mortality rate of Helicoverpa armigera neonates was examined in field crops and laboratory trials. In this study the following are examined: (1) the effects of soil surface temperature, and the level of shade within the crop, on the mortality of neonates on the soil after dropping off from the host plant; (2) the percentage of neonates that dropped off from a host plant and landed on the soil; and (3) the effects of exposure to different soil surface temperatures on the development and mortality of neonates. The findings of this study showed that: (1) on the soil, surface temperatures above 43°C were lethal for neonates, and exposure to these temperatures contributed greatly to the overall mortality rate observed; however, the fate of neonates on the soil varied significantly depending on canopy closure within the crop; (2) at least 15% of neonates dropped off from the host plant and landed on the soil, meaning that the proportion of neonates exposed to these condition is not trivial; and (3) 30 min exposure to soil surface temperatures approaching the lethal level (>43°C) has no significant negative effects on the development and mortality of larvae through to the second instar. Overall leaving the plant through drop-off contributes to first-instar mortality in crops with open canopies; however, survival of neonates that have lost contact with a host plant is possible, and becomes more likely later in the crop growing season.
Resumo:
The phenomenon of drop formation at conical tips under near zero flow conditions has been investigated using a theoretical approach. The analysis permits the prediction of drop profile and drop volume, until the onset of instability. A semiempirical approach based on the similarity of drop shapes has been adopted to predict the detaching drop volumes at conical tips. The effects of base diameter of the cone, cone angle, interfacial tension, and the densities of the drop and the surrounding fluid on the maximum and detached drop volumes are predicted.
Resumo:
Fruit drop in lychee can cause major yield losses in Australia, the severity varying with cultivar and season. Research in China, South Africa and Israel has demonstrated the potential for synthetic auxins used as foliar sprays to reduce fruit drop in lychee. Trials were initiated in Australia to test the efficacy of the synthetic auxin, 3-5-6 Trichloro-2-phridyl-oxyacetic acid (3-5-6 TPA) at 50 ppm on the cultivars Tai So, Fay Zee Sui and Kwai Mai Pink. Results indicate that in most cases the TPA reduced natural fruit drop however the size of the fruit at the time of application affects the response and the ideal application time varies with cultivar; approximately 13 mm fruit length in 'Kwai Mai Pink', 20 mm in 'Fay Zee Sui' and 27 mm in 'Tai So'. If applied too early in 'Tai So', it caused an increase in fruit drop. The TPA was most effective when natural fruit drop was high, reducing fruit drop from 74.7 to 34.9% in 'Kwai Mai Pink' and least effective when natural fruit drop was low. An increase in the percentage of fruit with poorly developed (chicken tongue) seed and slightly larger fruit size was also observed in treated trees.
Resumo:
Using benzene as a candidate air toxicant and A549 cells as an in vitro cell model, we have developed and validated a hanging drop (HD) air exposure system that mimics an air liquid interface exposure to the lung for periods of 1 h to over 20 days. Dose response curves were highly reproducible for 2D cultures but more variable for 3D cultures. By comparing the HD exposure method with other classically used air exposure systems, we found that the HD exposure method is more sensitive, more reliable and cheaper to run than medium diffusion methods and the CULTEX (R) system. The concentration causing 50% of reduction of cell viability (EC50) for benzene, toluene, p-xylene, m-xylene and o-xylene to A549 cells for 1 h exposure in the HD system were similar to previous in vitro static air exposure. Not only cell viability could be assessed but also sub lethal biological endpoints such as DNA damage and interleukin expressions. An advantage of the HD exposure system is that bioavailability and cell concentrations can be derived from published physicochemical properties using a four compartment mass balance model. The modelled cellular effect concentrations EC50(cell) for 1 h exposure were very similar for benzene, toluene and three xylenes and ranged from 5 to 15 mmol/kg(dry weight) which corresponds to the intracellular concentration of narcotic chemicals in many aquatic species, confirming the high sensitivity of this exposure method. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
A recently developed hanging drop air exposure system for toxicity studies of volatile chemicals was applied to evaluate the cell viability of lung carcinoma A549 cells after 1 h and 24 h of exposure to benzene, toluene, ethylbenzene and xylenes (BTEX) as individual compounds and mixtures of 4 or 6 components. The cellular chemical concentrations causing 50% reduction of cell viability (EC50) were calculated use a mass balance model and came to 17, 12, 11, 9, 4 and 4 mmol/kg cell dry weight for benzene, toluene, ethylbenzene, m-xylene, o-xylene and p-xylene respectively after 1 h of exposure. The EC50 decreased by a factor of four after 24 h of exposure. All mixture effects were best described by the mixture toxicity model of concentration addition, which is valid for chemicals with the same mode of action. Good agreement with the model predictions were found for benzene, toluene, ethylbenzene and m-xylene at four different representative fixed concentration ratios after 1 h of exposure but lower agreement to mixture prediction was obtained after 24 h of exposure. A recreated car exhaust mixture, which involved the contribution of the more toxic p-xylene and o-xylene, yielded an acceptable but lower quality prediction as well.
Resumo:
Fruit drop can cause major yield losses in Australian lychee orchards, the severity varying with cultivar and season. Research in China, South Africa and Israel has demonstrated the potential for synthetic auxins used as foliar sprays to reduce fruit drop in lychee. Trials tested the efficacy of the synthetic auxin 3-5-6 trichloro-2-phridyl-oxyacetic acid (TPA) applied as a foliar spray at 50 ppm on fruit drop and fruit size on the cultivars ‘Fay Zee Siu’, ‘Kaimana’, ‘Kwai Mai Pink’, ‘Souey Tung’ and ‘Tai So’. TPA reduced fruit drop when applied to fruit greater than 12 mm in length but increased fruit drop when fruit were smaller. Fruit size at the time of application had less effect on the response than the level of natural fruit drop. When natural fruit drop was high, TPA significantly reduced it; by up to 18.7 in ‘Fay Zee Siu’, 37.1 in ‘Kaimana’, 39.8 in ‘Kwai Mai Pink’, 15.1 in ‘Souey Tung’ and 7.7 in ‘Tai So’. TPA was less effective when natural fruit drop was low. TPA increased the number of large fruit and frequently increased the number of small fruit at harvest. The small fruit were associated with an increase in the retention of fruit with poorly developed (chicken tongue) seed. Average fruit size was generally larger (up to 12.7 in ‘Souey Tung’ and 22 in ‘Tai So’) with TPA applications.
Resumo:
Spreading and receding processes of water drops impacting on a stainless steel surface comprising rectangular shaped parallel grooves are studied experimentally. The study was confined to the impact of drops in inertia dominated flow regime with Weber number in the range 15 - 257. Measurements of spreading drop diameter and drop height were obtained during the impact process as function of time. Experimental measurements of spreading drop diameter and drop height obtained for the grooved surface were compared with those obtained for a smooth surface to elucidate the influence of surface grooves on the impact process. The grooves definitely influence both spreading and receding processes of impacting liquid drops. A more striking observation from this study is that the receding process of impacting liquid drops is dramatically changed by the groove structure for all droplet Weber number.
Resumo:
Benzene drops were formed in continuous media of water and glycerine of varying physical properties. The effect on drop volumes of variables like volumetric flow-rate, interfacial tension, continuous phase viscosity and capillary diameter was studied. An equation has been developed, based on a two stage drop formation mechanism, which predicts drop volumes within an average error of 7 per cent for the range of physical properties employed in this investigation.
Resumo:
An approach, starting with the bubble formation model of Khurana and Khumar, has been presented, which is found to be reasonably applicable to the formation of both bubbles and drops from single submerged nozzles. The model treats both the phenomena jointly as the formation of a dispersed phase entity resulting from injection, whose size depends upon operating parameters and physical properties.
Resumo:
Drop formation from single nozzles under pulsed flow conditions in non-Newtonian fluids following the power law model has been studied. An existing model has been modified to explain the experimental data. The flow conditions employed correspond to the mixer—settler type of operation in pulsed sieve-plate extraction columns. The modified model predicts the drop sizes satisfactorily. It has been found that consideration of non-Newtonian behaviour is important at low pulse intensities and its significance decreases with increasing intensity of pulsation. Further, the proposed model for single orifices has been tested to predict the sizes of drops formed from a sieve-plate distributor having four holes, and has been found to predict the sizes fairly well in the absence of coalescence.
Resumo:
The existingm odels of drop breakage in stirred dispersions grossly overpredict the maximum drop size when surface active agents are present inspite of using the lowered value of interfacial tension. It is shown that the difference in the values of dynamic and static interfacial tension, aids the turbulent stresses in drop breakage. When the difference is zero, e.g. for pure liquids and for high concentration of surfactants, the influence of the addition of surfactant is merely to reduce the interfacial tension and can be accounted for by existingm odels. A modified model has been developed, where the drop breakage is assumed to be represented by a Voigt element. The deforming stresses are due to turbulence and the difference between dynamic and static interfacial tensions. The resisting stresses arise due to interfacial tension and the viscous flow inside the drop. The model yields the existing expressions for dmax as special cases. The model has been found to be satisfactory when tested against experimental results using the styrene-water-teepol system.
Resumo:
Existing models for dmax predict that, in the limit of μd → ∞, dmax increases with 3/4 power of μd. Further, at low values of interfacial tension, dmax becomes independent of σ even at moderate values of μd. However, experiments contradict both the predictions show that dmax dependence on μd is much weaker, and that, even at very low values of σ,dmax does not become independent of it. A model is proposed to explain these results. The model assumes that a drop circulates in a stirred vessel along with the bulk fluid and repeatedly passes through a deformation zone followed by a relaxation zone. In the deformation zone, the turbulent inertial stress tends to deform the drop, while the viscous stress generated in the drop and the interfacial stress resist deformation. The relaxation zone is characterized by absence of turbulent stress and hence the drop tends to relax back to undeformed state. It is shown that a circulating drop, starting with some initial deformation, either reaches a steady state or breaks in one or several cycles. dmax is defined as the maximum size of a drop which, starting with an undeformed initial state for the first cycle, passes through deformation zone infinite number of times without breaking. The model predictions reduce to that of Lagisetty. (1986) for moderate values of μd and σ. The model successfully predicts the reduced dependence of dmax on μd at high values of μd as well as the dependence of dmax on σ at low values of σ. The data available in literature on dmax could be predicted to a greater accuracy by the model in comparison with existing models and correlations.
Resumo:
Existing models for dmax predict that, in the limit of μd → ∞, dmax increases with 3/4 power of μd. Further, at low values of interfacial tension, dmax becomes independent of σ even at moderate values of μd. However, experiments contradict both the predictions show that dmax dependence on μd is much weaker, and that, even at very low values of σ,dmax does not become independent of it. A model is proposed to explain these results. The model assumes that a drop circulates in a stirred vessel along with the bulk fluid and repeatedly passes through a deformation zone followed by a relaxation zone. In the deformation zone, the turbulent inertial stress tends to deform the drop, while the viscous stress generated in the drop and the interfacial stress resist deformation. The relaxation zone is characterized by absence of turbulent stress and hence the drop tends to relax back to undeformed state. It is shown that a circulating drop, starting with some initial deformation, either reaches a steady state or breaks in one or several cycles. dmax is defined as the maximum size of a drop which, starting with an undeformed initial state for the first cycle, passes through deformation zone infinite number of times without breaking. The model predictions reduce to that of Lagisetty. (1986) for moderate values of μd and σ. The model successfully predicts the reduced dependence of dmax on μd at high values of μd as well as the dependence of dmax on σ at low values of σ. The data available in literature on dmax could be predicted to a greater accuracy by the model in comparison with existing models and correlations.