915 resultados para Doppler parameters


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The high and increasing prevalence of Dilated Cardiomyopathy (DCM) represents a serious public health issue. Novel technologies have been used aiming to improve diagnosis and the therapeutic approach. In this context, speckle tracking echocardiography (STE) uses natural myocardial markers to analyze the systolic deformation of the left ventricle (LV). Objective: Measure the longitudinal transmural global strain (GS) of the LV through STE in patients with severe DCM, comparing the results with normal individuals and with echocardiographic parameters established for the analysis of LV systolic function, in order to validate the method in this population. Methods: Seventy-one patients with severe DCM (53 +/- 12 years, 72% men) and 20 controls (30 +/- 8 years, 45% men) were studied. The following variables were studied: LV volumes and ejection fraction calculated by two and three-dimensional echocardiography, Doppler parameters, Tissue Doppler Imaging systolic and diastolic LV velocities and GS obtained by STE. Results: Compared with controls, LV volumes were higher in the DCM group; however, LVEF and peak E-wave velocity were lower in the latter. The myocardial performance index was higher in the patient group. Tissue Doppler myocardial velocities (S', e', a') were significantly lower and E/e' ratio was higher in the DCM group. GS was decreased in the DCM group (-5.5% +/- 2.3%) when compared with controls (-14.0% +/- 1.8%). Conclusion: In this study, GS was significantly lower in patients with severe DCM, bringing new perspectives for therapeutic approaches in this specific population. (Arq Bras Cardiol 2012;99(3):834-842)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E), peak A wave (peak A), E/A ratio (E/A), E wave deceleration time (EDT) and isovolumic relaxation time (IRVT) were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT), by age (peak A and E/A) and by body weight (TRIV). Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this study was to describe multiple Doppler ultrasound parameters of ductus venosus and inferior vena cava in fetuses at gestational ages ranging from 22 to 38 weeks. In this prospective observational study, Doppler ultrasound exams were performed in 45 healthy fetuses at 22, 26, 34, and 38 weeks. Maximum venous velocity, minimum venous velocity, venous pulsatility index, and venous acceleration time (VAT) (defined as the time between minimum and maximum venous velocity) were evaluated at those gestational periods. Increase in the velocities and decrease in the pulsatility index were observed in these vessels throughout gestational age. The VAT increased with gestational age. The VAT, a Doppler parameter still not described elsewhere, increased during pregnancy could be related to a longer period of time needed to fill the atrium in bigger hearts. In this study, we provide reference values for VAT in healthy fetuses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E), peak A wave (peak A), E/A ratio (E/A), E wave deceleration time (EDT) and isovolumic relaxation time (IRVT) were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT), by age (peak A and E/A) and by body weight (TRIV). Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Foram comparados dois métodos não-invasivos de medida da pressão arterial, o Doppler vascular e o oscilométrico, com o objetivo de estabelecer parâmetros que possam auxiliar no diagnóstico seguro da hipertensão arterial. Para tal, foram utilizados 45 cães, machos e fêmeas, distribuídos em três grupos de acordo com o peso, pequeno, médio e grande porte. Em cada animal, procedeu-se a mensuração por meio do Doppler vascular e, em seguida, do oscilométrico. Na obtenção da pressão arterial sistólica, não houve diferença entre os métodos nos três grupos de animais, porém, na obtenção da pressão arterial diastólica, houve diferença estatística entre o Doppler vascular e o oscilométrico nos grupos de animais de pequeno e médio porte. Pôde-se concluir que valores confiáveis de pressão sistólica podem ser obtidos tanto por meio do Doppler vascular quanto do oscilométrico. Os valores da pressão arterial diastólica obtidos pelos dois métodos não se correlacionam, principalmente nos animais de pequeno e médio porte.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Avaliaram-se com Doppler pulsátil os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), de 30 cães considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica. Obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,22± 19,38m/s; V. Me. AO= 0,72± 0,08m/s; VTI AO= 0,14± 0,02m; TA AO= 38,80± 11,29ms; TE AO= 197,90± 24,77ms; V. Max. Pul= 0,95± 0,18m/s; V. Me. Pul= 0,63± 0,10m/s; VTI Pul= 0,13± 0,02m; TA Pul= 70,97± 18,87ms; TE Pul= 203,70± 28,98ms. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros apresentaram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul); outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VTI Pul, TE Pul,) e não se observou influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n = 50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17 +/- 13.46 cm/s and 0.38 +/- 0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15 +/- 0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17 +/- 9.40 cm/s and 0.54 +/- 0.07. The RA had a mean ESA of 1.12 +/- 1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828 +/- 0.296. The IA showed PSV and RI values of 32.16 +/- 9.33 cm/s and 0.52 +/- 0.06, respectively. The mean ESA of all IAs was 0.73 +/- 0.61 m/s(2). The calculated upper limit of the reference value was 2.0 m/s(2). The mean renal-interlobar artery ratio was 1.45 +/- 0.57. The RI values obtained in this study were similar to values reported in the literature. Some conditions that lead to a decrease in compliance and to an increase in vascular resistance can affect the Doppler spectral waveforms without changes in RI. To our knowledge, there are no studies that were directed toward to the normal ESA values of the renal vasculature in Persian cats. This study introduced a new ratio between the PSV of the RA and the IA. This index was developed based on the well-known effects of Doppler on the detection of stenosis, regardless of the cause. Further studies are necessary to verify the hemodynamic behavior of this index under pathological conditions in cats as well as the effect of aging, nephropathies and systemic pressure on Doppler velocimetric parameters. (C) 2010 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the impact of systematic use of intraoperative Doppler ultrasound during microsurgical subinguinal varicocele repair. Design: Prospective clinical study. Setting: Andrology laboratory and male infertility section of the urology department of a tertiary care hospital. Patient(s): Two hundred and thirteen men with clinical varicocele. Intervention(s): Subinguinal microsurgical varicocele ligation using an intraoperative vascular Doppler flow detector. Main Outcome Measure(s): Number of veins ligated, lymphatic spared, arteries identified or accidentally ligated. Result(s): A statistically significant greater number of arteries were identified and preserved when intraoperative vascular Doppler was used. In addition, the average number of internal spermatic veins ligated was statistically significantly greater in the same group. Accidental artery ligation occurred in two cases (1.1%) in which the Doppler was not applied. There was no statistically significant difference in number of lymphatics spared between groups. Conclusion(s): Our findings showed that concomitant use of intraoperative vascular Doppler during microsurgical varicocelectomy allows more arterial branches to be preserved, and more internal spermatic veins are likely to be ligated. This device should be considered an attractive tool to improve surgical outcomes and safety. (Fertil Steril (R) 2010; 93: 2396-9. (C)2010 by American Society for Reproductive Medicine.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To determine reference values for tissue Doppler imaging (TDI) and pulsed Doppler echocardiography for left ventricular diastolic function analysis in a healthy Brazilian adult population. Observations were based on a randomly selected healthy population from the city of Vitoria, Espirito Santo, Brazil. Healthy volunteers (n = 275, 61.7% women) without prior histories of cardiovascular disease underwent transthoracic echocardiography. We analyzed 175 individuals by TDI and evaluated mitral annulus E`- and A`-waves from the septum (S) and lateral wall (L) to calculate E`/A` ratios. Using pulsed Doppler echocardiography, we further analyzed the mitral E- and A-waves, E/A ratios, isovolumetric relaxation times (IRTs), and deceleration times (DTs) of 275 individuals. Pulsed Doppler mitral inflow mean values for men were as follows: E-wave: 71 +/- 16 cm/sec, A-wave: 68 +/- 15 cm/sec, IRT: 74.8 +/- 9.2 ms, DT: 206 +/- 32.3 ms, E/A ratio: 1.1 +/- 0.3. Pulsed Doppler mitral inflow mean values for women were as follows: E-wave: 76 +/- 17, A-wave: 69 +/- 14 cm/sec, IRT: 71.2 +/- 10.5 ms, DT: 197 +/- 33.3 ms, E/A ratio: 1.1 +/- 0.3. IRT and DT values were higher in men than in women (P = 0.04 and P = 0.007, respectively). TDI values in men were as follows: E`S: 11 +/- 3 cm/sec, A`S: 13 +/- 2 cm/sec, E`S/A`S: 0.89 +/- 0.2, E`L: 14 +/- 3 cm/sec, A`L: 14 +/- 2 cm/sec, E`L/A`L: 1.1 +/- 0.4. E-wave/ E`S ratio: 6.9 +/- 2.2; E-wave / E`L ratio: 4.9 +/- 1.7. In this study, we determined pulsed Doppler and TDI derived parameters for left ventricular diastolic function in a large sample of healthy Brazilian adults. (Echocardiography 2010;27:777-782).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Accurate diagnosis of portal vein (PV) stenosis by real-time and color Doppler US (CD-US) after segmental liver transplantation in children can decrease morbidity by avoiding unnecessary biopsy, PV hypertension, thrombosis and loss of the graft. Objective To evaluate CD-US parameters for the prediction of PV stenosis after segmental liver transplantation in children. Materials and methods We retrospectively reviewed 61 CD-US examinations measuring the diameter at the PV anastomosis, velocities at the anastomosis (PV1) and in the segment proximal to the anastomosis (PV2), and the PV1/PV2 velocity ratio. The study group comprised patients with stenosis confirmed by angiography and the control group comprised patients with a good clinical outcome. Results PV stenosis was seen in 12 CD-US examinations. The mean PV diameter was smaller in the study group (2.6 mm versus 5.7 mm) and a PV diameter of < 3.5 mm was highly predictive of stenosis (sensitivity 100%, specificity 91.8%). Conclusion A PV diameter of < 3.5 mm is a highly predictive CD-US parameter for the detection of hemodynamically significant stenosis on angiography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To compare color Doppler imaging (CDI) parameters of the superior ophthalmic vein (SOV) in patients with Graves` orbitopathy (GO) and in normal controls. Forty-three GO patients and 14 normal controls underwent CDI of the SOV. Patients had either fibrotic (lipogenic or myogenic) or congestive orbitopathy. The findings for each group were compared. Fifty-eight orbits with fibrotic orbitopathy, 28 with congestive orbitopathy, and 28 from controls, were studied. In the congestive group, SOV flow was detected in 13, undetectable in 11, and reversed in four orbits; in the fibrotic group, it was present in 41 and undetectable in 17 orbits. In normal controls, SOV flow was detected in 25 and undetectable in three orbits. The differences among the three groups were significant. There was also a significant difference between controls and the congestive GO orbits but not between the fibrotic group and the other two groups. Fibrotic myogenic orbitopathy patients displayed a significantly smaller SOV flow than patients with lipogenic orbitopathy. SOV was significantly reduced in orbits with congestive GO or with myogenic fibrotic GO, but not in orbits with fibrotic lipogenic orbitopathy. SOV congestion may be a contributing pathogenic factor in both congestive and fibrotic myogenic Graves` orbitopathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Heart transplantation (OHT) has traditionally been contraindicated in the presence of severe pulmonary hypertension (PH), as detected by right heart catheterization. Noninvasive methods are still not reliably accurate to make this evaluation. Objectives. Determine the efficacy of echo Doppler analysis for the diagnosis of severe PH. Methods. One hundred thirty patients (mean age = 42 +/- 15 years, 82 men) showed severe left ventricular dysfunction (mean ejection fraction = 29 +/- 12%; functional class III-IV). We excluded patients with atrial fibrillation, heart failure secondary to congenital disease, and valvulopathy. The pulmonary parameters defined as severe PH were: systolic pulmonary artery pressure (sPAP) >= 60 mm Hg; a mean transpulmonary gradient >= 15; or pulmonary vascular resistance >= 5 Wood units. Patients underwent a right heart catheterization using a Swan-Ganz catheter to measure hemodynamic parameters and to noninvasively estimate right-sided pressures from spectral Doppler recordings of tricuspid regurgitation velocity (right ventricular systolic pressure [RVsP]). A Pearson correlation of sPAP was obtained with RVsP by; the sensitivity of RVsP for the diagnosis of PH was determined by a receiver operating characteristic (ROC) curve. Results. A good correlation between sPAP and RVsP was obtained by Pearson correlation analysis (r = 0.64; 95% confidence interval [CI] 0.50-0.75; P < .001). The ROC curve analysis showed a sensitivity of 100%, a specificity of 37.2%, (95% CI 0.69-0.83, P < .0001) of a RVsP < 45 mm Hg (cutoff) on the exclusion of severe PH. Conclusions. The cutoff of RVsP < 45 mm Hg, on noninvasive echo Doppler evaluation of PH is an efficient method to replace invasive heart catheterization in OHT candidates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Objectives: To analyze the role of arterial baroreflex on hemodynamic changes during synchronized and desynchronized sleep phases of natural sleep in rats. Design: Experimental study. Setting: Laboratory. Participants: Seventeen male Wistar rats. Interventions: No intervention (control, n = 8) or sinoaortic denervation (SAD, n = 9). Measurements and Results: Sleep phases were monitored by electrocorticogram, and blood pressure was measured directly by a catheter in the carotid artery. Cardiac output, as well as total and regional vascular resistances, were determined by measuring the subdiaphragmatic aorta and iliac artery flows with Doppler flow probes, respectively. In contrast to the control group, the SAD group had a strong reduction in blood pressure (-19.9% +/- 2.6% vs -0.7% +/- 2.1%) during desynchronized sleep, and cardiac output showed an exacerbated reduction (-10.4% +/- 3.5% vs 1.1% +/- 1.7%). In SAD rats, total vascular resistance decreased during desynchronized sleep (-10.1% +/- 3.5% vs -1.0% +/- 1.7%), and the increase in regional vascular resistance observed in the control group was abolished (27.5% +/- 8.3% vs -0.8% +/- 9.4%). Conclusions: SAD caused profound changes in blood pressure, cardiac output, and total vascular resistance, with a significant increase in muscle vascular resistance during synchronized sleep. Our results suggest that baroreflex plays an important role in maintaining the normal balance of cardiac output and total vascular resistance during sleep.