Resumo:
The activity of Control Center operators is important to guarantee the effective performance of Power Systems. Operators’ actions are crucial to deal with incidents, especially severe faults like blackouts. In this paper, we present an Intelligent Tutoring approach for training Portuguese Control Center operators in tasks like incident analysis and diagnosis, and service restoration of Power Systems. Intelligent Tutoring System (ITS) approach is used in the training of the operators, having into account context awareness and the unobtrusive integration in the working environment. Several Artificial Intelligence techniques were criteriously used and combined together to obtain an effective Intelligent Tutoring environment, namely Multiagent Systems, Neural Networks, Constraint-based Modeling, Intelligent Planning, Knowledge Representation, Expert Systems, User Modeling, and Intelligent User Interfaces.
Resumo:
The activity of Control Center operators is important to guarantee the effective performance of Power Systems. Operators’ actions are crucial to deal with incidents, especially severe faults, like blackouts. In this paper we present an Intelligent Tutoring approach for training Portuguese Control Centre operators in tasks like incident analysis and diagnosis, and service restoration of Power Systems. Intelligent Tutoring System (ITS) approach is used in the training of the operators, taking into account context awareness and the unobtrusive integration in the working environment.
Resumo:
In this work the problem of defects location in power systems is formulated through a binary linear programming (BLP) model based on alarms historical database of control and protection devices from the system control center, sets theory of minimal coverage (AI) and protection philosophy adopted by the electric utility. In this model, circuit breaker operations are compared to their expected states in a strictly mathematical manner. For solving this BLP problem, which presents a great number of decision variables, a dedicated Genetic Algorithm (GA), is proposed. Control parameters of the GA, such as crossing over and mutation rates, population size, iterations number and population diversification, are calibrated in order to obtain efficiency and robustness. Results for a test system found in literature, are presented and discussed. © 2004 IEEE.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Objective To verify the effects of a systematized multimodal exercise intervention program on frontal cognitive function, postural control, and functional capacity components of individuals with Alzheimer's disease (AD).DesignNonrandomized controlled trial with pre- and posttraining tests in a training group and a control group.SettingKinesiotherapy program for seniors with AD, SAo Paulo State University.ParticipantsConvenience sample of older adults with AD (n=30) were assigned to a training (n=14; aged 78.67.1) and a control (n=16; aged 77.06.3) group.InterventionThe intervention program was structured with the aim of simultaneously promoting better balance and frontal cognitive capacity. The participants attended a 1-hour session three times a week for 16weeks, whereas the control group did not participate in any activity during the same period.MeasurementsFrontal cognitive function was evaluated using the Montreal Cognitive Assessment, the Clock Drawing Test, the Frontal Assessment Battery, and the Symbol Search Subtest. Postural control (center of pressure area) was analyzed under four dual-task conditions. Functional capacity components were analyzed using the Timed Up and Go Test, the 30-second sit-to-stand test, the sit-and-reach test, and the Berg Functional Balance Scale.ResultsIntervention group participants showed a significant increase in frontal cognitive function (P<.001, partial (2)=0.838), with less body sway (P=.04, partial (2)=0.04) during the dual tasks, and greater functional capacity (P=.001, partial (2)=0.676) after the 16-week period.ConclusionIntervention participants performed better on dual-task activities and had better postural balance and greater functional capacity than controls.
Resumo:
Across the industry, regardless of the activity which is intended, the electricity distribution must meet the current and ever growing needs of the market, aiming at reliability and process efficiency. The energy must not only be available to ensure continuity of operation, but also to avoid the costs incurred due to deficiencies and failures. The tendency to migrate to intelligent systems is undeniable and this thesis will be analyzed the advantages that made this kind technology essential, focused on the analysis of the motor control center and as sturdy equipment fit to the concept of intelligent panels. The case study compares in a real scenario the acquisition of a system of low-voltage electrical panels comparing the cost to purchase the same set of panels made with and without the concept of intelligence
Resumo:
Across the industry, regardless of the activity which is intended, the electricity distribution must meet the current and ever growing needs of the market, aiming at reliability and process efficiency. The energy must not only be available to ensure continuity of operation, but also to avoid the costs incurred due to deficiencies and failures. The tendency to migrate to intelligent systems is undeniable and this thesis will be analyzed the advantages that made this kind technology essential, focused on the analysis of the motor control center and as sturdy equipment fit to the concept of intelligent panels. The case study compares in a real scenario the acquisition of a system of low-voltage electrical panels comparing the cost to purchase the same set of panels made with and without the concept of intelligence
Resumo:
Shift workers from control centers of electrical systems are a group that has received little attention in Brazil. This study aimed to compare workers' job satisfaction at five control centers of a Brazilian company electrical system, and according to their job titles. Method: The Organization Satisfaction Index (OSI) questionnaire to assess job satisfaction was used. ANOVA was used to compare OSI means, according to job title and control center. The results showed that there is no difference in job satisfaction among job titles, but a significant difference was found according to the control center. A single organizational culture cannot be applied to several branches. It is required to implement actions that would result in job satisfaction improvements among workers of all studied control rooms centers. The high level of education of operators working in all centers might have contributed to the similar values of perceived satisfaction among distinct job titles.
Resumo:
Las normativas que regulan la seguridad de las presas en España han recogido la necesidad de conocer los desplazamientos y deformaciones de sus estructuras y cimientos. A día de hoy, son muchas las presas en explotación que no cuentan con un sistema de auscultación adecuado para controlar este tipo de variables, ya que la instalación de métodos clásicos de precisión en las mismas podría no ser viable técnicamente y, de serlo, supondría un coste económico importante y una dudosa garantía del proceso de ejecución de la obra civil correspondiente. Con el desarrollo de las nuevas tecnologías, la informática y las telecomunicaciones, han surgido nuevos sistemas de auscultación de desplazamientos. Los sistemas GPS actuales, diseñados para el control de estructuras, guiado de maquinaria, navegación y topografía, estabilidad de taludes, subsidencias, etc. permiten alcanzar precisiones centimétricas. El sistema de control de movimientos basado en la tecnología DGPS (GPS diferencial) combinada con un filtro estadístico con el que se alcanzan sensibilidades de hasta ±1 mm en el sistema, suficientes para una auscultación normal de presas según los requerimientos de la normativa actual. Esta exactitud se adapta a los desplazamientos radiales de las presas, donde son muy comunes valores de amplitudes en coronación de hasta 15 mm en las de gravedad y de hasta 45 mm en el caso de las presas bóveda o arco. La presente investigación tiene por objetivo analizar la viabilidad del sistema DGPS en el control de movimientos de presas de hormigón comparando los diferentes sistemas de auscultación y su correlación con las variables físicas y las vinculadas al propio sistema GPS diferencial. Ante la necesidad de dar respuesta a estas preguntas y de validar e incorporar a la mencionada tecnología en la ingeniería civil en España, se ha llevado a cabo un estudio de caso en La Aceña (Ávila). Esta es una de las pocas presas españolas que se está controlando con dicha tecnología y de forma simultánea con los sistemas clásicos de auscultación y algunos otros de reciente aplicación La presente investigación se ha organizado con idea de dar respuesta a varias preguntas que el explotador de presas se plantea y que no se analizan en el estado del arte de la técnica: cómo hacer la configuración espacial del sistema y cuáles son los puntos necesarios que se deben controlar, qué sistemas de comunicaciones son los más fiables, cuáles son los costes asociados, calibración del software, vida útil y mantenimientos requeridos, así como la posibilidad de telecontrolar los datos. Entre las ventajas del sistema DGPS, podemos señalar su bajo coste de implantación y posibilidad de controlarlo de forma remota, así como la exactitud y carácter absoluto de los datos. Además, está especialmente indicado para presas aisladas o mal comunicadas y para aquellas otras en las que el explotador no tiene referencia alguna de la magnitud de los desplazamientos o deformaciones propias de la presa en toda su historia. Entre los inconvenientes de cualquier sistema apoyado en las nuevas tecnologías, destaca la importancia de las telecomunicaciones ya sea en el nivel local en la propia presao desde su ubicación hasta el centro de control de la explotación. Con la experiencia alcanzada en la gestión de la seguridad de presas y sobre la base de la reciente implantación de los nuevos métodos de auscultación descritos, se ha podido analizar cada una de sus ventajas e inconvenientes. En el capítulo 5, se presenta una tabla de decisión para el explotador que servirá como punto de partida para futuras inversiones. El impacto de esta investigación se ha visto reflejado en la publicación de varios artículos en revistas indexadas y en el debate suscitado entre gestores y profesionales del sector en los congresos nacionales e internacionales en los que se han presentado resultados preliminares. All regulations on the safety of dams in Spain have collected the need to know the displacements and deformations of the structure and its foundation. Today there are many dams holding not have an adequate system of auscultation to control variables such as the installation of classical methods of precision in the same might not be technically feasible, and if so, would cost important economic and guarantee the implementation process of the dubious civil works. With the development of new technologies, computing and telecommunications, new displacements auscultation systems have emerged. Current GPS systems designed to control structures, machine guidance, navigation and topography, slope stability, subsidence, etc, allow to reach centimeter-level accuracies. The motion control system based on DGPS technology applies a statistical filter that sensitivities are achieved in the system to ± 1 mm, sufficient for normal auscultation of dams as required by current regulations. This accuracy is adapted to the radial displacement of dams, which are common values in coronation amplitudes up to 15 mm in gravity dams and up to 45 mm in arch or arc dams. This research aims to analyze the feasibility of DGPS system in controlling movements of concrete dams, comparing the different systems auscultation and its correlation with physical variables and linked to differential GPS system itself. Given the need to answer this question and to validate and incorporate this technology to civil engineering in Spain, has conducted a case study in real time at the dam La Aceña (Ávila). This dam is one of the few Spanish companies, which are controlling with this technology and simultaneously with the classic auscultation systems and some other recent application. This research has been organized with a view to responding to questions that the dam operator arises and in the state of the art technique not discussed: how to make spatial configuration of the system and what are the necessary control points what communication systems are the most reliable, what are the associated costs, calibration software, service life and maintenance requirements, possibility of monitoring, etc. Among the advantages we can point to its low cost of implementation, the possibility of remote, high accuracy and absolute nature of the data. It could also be suitable for those isolated or poorly communicated dams and those in which the operator has no reference to the magnitude of displacements or deformations own prey in its history. The disadvantages of any system based on the new technologies we highlight the importance of telecommunications, either locally or from this dam control center of the farm. With the experience gained in the management of dam safety and based on the recent introduction of new methods of auscultation described, it has been possible to analyze each of their advantages and disadvantages. A decision table for the operator, which will serve as a starting point for future investments is presented. The impact of research, has been reflected in the publication of several articles in refereed journals and discussion among managers and professionals in national and international conferences in which they participated.
Resumo:
Una red inalámbrica de sensores (Wireless Sensor Network, WSN) constituye un sistema de comunicación de datos flexible utilizado como alternativa a las redes cableadas o como extensión de éstas. Una de las aplicaciones de estas redes es para su uso en sistemas de predicción y prevención de incendios en áreas naturales. Su implementación se basa en el despliegue de sensores inalámbricos, realizado en una zona de riesgo de incendio que puedan recolectar información tal como temperatura, humedad y presión. Desde una estación base (o nodo "sumidero"), se suministra la información de los sensores a un centro de monitorización y control de forma estructurada. En estos centros la información recibida puede ser analizada, procesada y visualizada en tiempo real. Desde este centro de control se puede controlar también la red WSN modificando el comportamiento de los sensores según el nivel de riesgo de incendio detectado. Este proyecto se basa en el diseño, desarrollo e implementación de un Sistema de Control y Visualización de Información sobre Riesgo de Incendio (SCVIRI), que implementa las funciones de los centros de monitorización y control. La implementación de este sistema, junto con el desarrollado, en paralelo, de otro proyecto denominado Sistema de Estimación de Riesgo de Incendio Utilizando una WSN (SERIUW) que implementa la emulación de la red WSN, conforman un sistema general de anticipación y seguimiento de Fuegos. Se han realizado pruebas de funcionalidad y eficacia, incluidas en la presente memoria del sistema general (ambos proyectos), en un entorno controlado simulado. Este sistema es una solución para la lucha contra los incendios forestales ya que predice y previene, de forma temprana, posibles incendios en las áreas naturales bajo supervisión. Ante un evento de incendio declarado este sistema es un poderoso instrumento de apoyo permitiendo, por un lado, generar alertas automáticas (con localización y gravedad de fuegos detectados) y por el otro, hacer un seguimiento del incendio con mapas en tiempo real (con su consecuente apoyo para la protección e información con las brigadas de bomberos en las zonas activas). ABSTRACT. A wireless sensor network (WSN) is a flexible data communication system used as an alternative to wired networks or as an extension of them. One possible application of these networks is related to fire prediction and prevention in natural areas. Its implementation is based on a deployment of wireless sensors, in an area with high or moderate fire risk, to collect information such as temperature, humidity, luminance and pressure. A base station (or "sink") sends the collected information to a monitoring and control center according to an agreed structured format. At this center, the information received can be analyzed, processed and displayed in real time by using monitoring systems. From this control center the WSN can also be controlled by changing the sensors behavior in consistence with the detected level of fire risk. The work carried out in this project consists on the design, development and implementation of a system named SCVIRI, which implements the functions of the aforementioned monitoring and control center. This system works in connection with other one, called SERIUW, which has been developed in a different project and implements the WSN in an emulated environment. These two systems working together make up a general system of anticipation and monitoring of fires. This document also includes the functionality and performance tests performed on the overall system in a controlled and simulated environment. The global system is a solution that makes it easier to predict and prevent possible fires in natural areas under supervision. This system can be a powerful tool since, before a fire event is declared, it generates automatic alerts (including location and severity information) and allows the real-time motorization of fire evolution and its graphical visualization on maps. This could be also very useful for providing fire brigades with support, protection and information in zones in which a fire is already active.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
This paper presents a new approach to the transmission loss allocation problem in a deregulated system. This approach belongs to the set of incremental methods. It treats all the constraints of the network, i.e. control, state and functional constraints. The approach is based on the perturbation of optimum theorem. From a given optimal operating point obtained by the optimal power flow the loads are perturbed and a new optimal operating point that satisfies the constraints is determined by the sensibility analysis. This solution is used to obtain the allocation coefficients of the losses for the generators and loads of the network. Numerical results show the proposed approach in comparison to other methods obtained with well-known transmission networks, IEEE 14-bus. Other test emphasizes the importance of considering the operational constraints of the network. And finally the approach is applied to an actual Brazilian equivalent network composed of 787 buses, and it is compared with the technique used nowadays by the Brazilian Control Center. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Cyber-Physical Intelligence is a new concept integrating Cyber-Physical Systems and Intelligent Systems. The paradigm is centered in incorporating intelligent behavior in cyber-physical systems, until now too oriented to the operational technological aspects. In this paper we will describe the use of Cyber-Physical Intelligence in the context of Power Systems, namely in the use of Intelligent SCADA (Supervisory Control and Data Acquisition) systems at different levels of the Power System, from the Power Generation, Transmission, and Distribution Control Centers till the customers houses.
Resumo:
The purpose of this report is to record the first case of a hematophagous bat (Desmodus rotundus) infected with rabies virus in an urban area in Brazil. To the authors' knowledge, this is the first such case in Latin America. After discovering a bat in his garden at 10 o'clock in the morning, a resident of Ubatuba municipality asked the Zoonosis Control Center team to visit his home. The animal was caught alive on the same day and sent to the Pasteur Institute laboratory, where it was identified as a Desmodus rotundus specimen. Standard tests for rabies diagnosis were carried out (direct immunofluorescence and viral isolation), and the results were positive. The presence of different species of (primarily insectivorous) bats in urban areas represents a serious public health problem. This case, however, is indicative of a much greater risk because the species in question has hematophagous habits, what means this animals has a low energy reserves and, therefore, its need to feed daily.