992 resultados para Disk laser


Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: (1) To assess spinal cord blood flow (SCBF) during surgical treatment of disk extrusion in dogs and (2) to investigate associations between SCBF, clinical signs, presurgical MRI images, and 24-hour surgical outcome. STUDY DESIGN: Cohort study. ANIMALS: Chondrodystrophic dogs with thoracolumbar disk extrusion (n=12). METHODS: Diagnosis was based on clinical signs and MRI findings, and confirmed at surgery. Regional SCBF was measured intraoperatively by laser-Doppler flowmetry before, immediately after surgical spinal cord decompression, and after 15 minutes of lavaging the lesion. Care was taken to ensure a standardized surgical procedure to minimize factors that could influence measurement readings. RESULTS: A significant increase in intraoperative SCBF was found in all dogs (Wilcoxon's signed-rank test; P=.05) immediately after spinal cord decompression and after 15 minutes. Changes in SCBF were not associated with duration of clinical signs; initial or 24-hour neurologic status; or degree of spinal cord compression assessed by MRI. CONCLUSION: SCBF increases immediately after spinal cord decompression in dogs with disk herniation; however, increased SCBF was not associated with a diminished 24-hour neurologic status. CLINICAL RELEVANCE: An increase in SCBF does not appear to be either associated with the degree of spinal cord compression or of a magnitude sufficient to outweigh the benefit of surgical decompression by resulting in clinically relevant changes in 24-hour outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to improve the wear resistance of the gamma-TiAl intermetallic alloy, microstructure, room- and high-temperature (600 degrees C) wear behaviors of laser clad gamma/Cr7C3/TiC composite coatings with different constitution of NiCr-Cr3C2 precursor-mixed powders have been investigated by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive spectrometer (EDS), block-on-ring (room-temperature) and pin-on-disk (high-temperature) wear tests. The responding wear mechanisms are discussed in detail. Results show that microstructures of the laser clad composite coatings have non-equilibrium solidified microstructures consisting of primary hard Cr7C3 and TiC carbides and the inter-primary gamma/Cr7C3 eutectic matrix, about three to five times higher average microhardness compared with the TiAl alloy substrate. Higher wear resistance than the original TiAl alloy is achieved in the clad composite coatings under dry sliding wear conditions, which is closely related to the formation of non-equilibrium solidified reinforced Cr7C3 and TiC carbides and the positive contribution of the relatively ductile and tough gamma/Cr7C3 eutectics matrix and their stability under high-temperature exposure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

WE have designed a dual-beam magneto-optical (MO) storage system to test the dynamic storage properties of MO disks. The characteristics of this dual-beam system are demonstrated. Magnetic field modulated direct overwrite, which is a promising technique for highspeed MO storage, is realized on TbFeCo MO disks with this dual-beam MO system. The effect of light intensity, magnetic field intensity, and linear velocity of the disk and the modulating frequency variation on carrier-to-noise ratio is investigated. (C) 1997 Society of Photo-Optical Instrumentation Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two novel read-only memory (ROM) disks, one with an AgOx mask layer and the other with an AgInSbTe mask layer, are proposed and studied. The AgOx and the AgInSbTe films sputtered on the premastered substrates with pit depths of 50 nm and pit lengths (space) of 380 nm are studied by atomic force microscopy. Disk readout measurement is carried out using a dynamic setup with a laser wavelength of 632.8 nm and an object lens numerical aperture (NA) of 0.40. Results show that the superresolution effect happens only at a suitable oxygen flow ratio for the AgOx ROM disk. The best superresolution readout effect is achieved at an oxygen flow ratio of 0.5 with the smoothest film surface. Compared with the AgOx ROM disk, the AgInSbTe ROM disk has a much smoother film surface and better superresolution effect. A carrier-to-noise ratio (CNR) of above 40 dB can be obtained at an appropriate readout power and readout velocity. The readout CNR of both the AgOx and AgInSbTe ROM disks have a nonlinear dependence on the readout power. The superresolution readout mechanisms for these ROM disks are analyzed and compared as well. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel read-only memory (ROM) disk with an AgOx mask layer was proposed and studied in this letter. The AgOx films sputtered on the premastered substrates, with pits depth of 50 nm and pits length of 380 nm, were studied by an atomic force microscopy. The transmittances of these AgOx films were also measured by a spectrophotometer. Disk measurement was carried out by a dynamic setup with a laser wavelength of 632.8 nm and a lens numerical aperture (NA) of 0.40. The readout resolution limit of this setup was λ/(4NA) (400 nm). Results showed that the super-resolution readout happened only when the oxygen flow ratios were at suitable values for these disks. The best super-resolution performance was achieved at the oxygen flow ratio of 0.5 with the smoothest film surface. The super-resolution readout mechanism of these ROM disks was analyzed as well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two novel read-only memory (ROM) disks, one with an AgOx mask layer and the other with an AgInSbTe mask layer, are proposed and studied. The AgOx and the AgInSbTe films sputtered on the premastered substrates with pit depths of 50 nm and pit lengths (space) of 380 nm are studied by atomic force microscopy. Disk readout measurement is carried out using a dynamic setup with a laser wavelength of 632.8 nm and an object lens numerical aperture (NA) of 0.40. Results show that the superresolution effect happens only at a suitable oxygen flow ratio for the AgOx ROM disk. The best superresolution readout effect is achieved at an oxygen flow ratio of 0.5 with the smoothest film surface. Compared with the AgOx ROM disk, the AgInSbTe ROM disk has a much smoother film surface and better superresolution effect. A carrier-to-noise ratio (CNR) of above 40 dB can be obtained at an appropriate readout power and readout velocity. The readout CNR of both the AgOx and AgInSbTe ROM disks have a nonlinear dependence on the readout power. The superresolution readout mechanisms for these ROM disks are analyzed and compared as well. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fe:BiOx films are fabricated on K9 glass substrates by rf-magnetron sputtering of a BiFeO target under argon atmosphere with increasing sputtering power from 80 to 200 W at room temperature. It is found that the thin films grown at the sputtering power of 160W can be formed at an appropriate deposition rate and have an improved surface morphology. The XPS result reveals that the films investigated are comprised of Bi, Fe and O elements. A typical XRD pattern shows that no phase transition occurs in the films up to 400 degrees C. The results of the blue laser recording test demonstrate that the Fe:BiOx films have good writing sensitivity for blue laser beam (406.7 nm) and good stability after reading 10000 times. The recording marks of 200nm or less are obtained. These results indicate that the introduction of Fe into BiOx films can reduce the mark size and improve the stability of the films.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We experimentally demonstrate locking of a laser frequency to a resonance line of a micro disk resonator. Achieving 1±0.1 pm shifting detection, the approach can be applied for sensing enhancement and perturbation immune NSOM measurements. © 2012 OSA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We experimentally demonstrate locking of a laser frequency to a resonance line of a micro disk resonator. Achieving 1±0.1 pm shifting detection, the approach can be applied for sensing enhancement and perturbation immune NSOM measurements. © OSA 2012.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To compare the reproducibility of optic disk measurements provided by an image analyzer and a scanning laser tomograph. Methods: Ten images of the same eye of 10 normal volunteers were taken with the Heidelberg Retina Tomograph and with the Topcon ImageNet. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were used to evaluate the reproducibility of the measurements. Results: Eleven parameters were analyzed with the Topcon ImageNet. Six parameters (55%) had ICC greater than 90%. Four parameters (36%) had CV less than 10%. Twelve parameters were evaluated with the Heidelberg Retina Tomograph. Nine parameters (75%) had ICC over 90%. Nine parameters (75%) had CV less than 10%. Conclusion: Both systems provided reproducible data. The optic disk parameters provided by the Heidelberg Retina Tomograph had a better reproducibility than those obtained from the Topcon ImageNet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present our recent achievements in the growing and optical characterization of KYb(WO4)2 (hereafter KYbW) crystals and demonstrate laser operation in this stoichiometric material. Single crystals of KYbW with optimal crystalline quality have been grown by the top-seeded-solution growth slow-cooling method. The optical anisotropy of this monoclinic crystal has been characterized, locating the tensor of the optical indicatrix and measuring the dispersion of the principal values of the refractive indices as well as the thermo-optic coefficients. Sellmeier equations have been constructed valid in the visible and near-IR spectral range. Raman scattering has been used to determine the phonon energies of KYbW and a simple physical model is applied for classification of the lattice vibration modes. Spectroscopic studies (absorption and emission measurements at room and low temperature) have been carried out in the spectral region near 1 µm characteristic for the ytterbium transition. Energy positions of the Stark sublevels of the ground and the excited state manifolds have been determined and the vibronic substructure has been identified. The intrinsic lifetime of the upper laser level has been measured taking care to suppress the effect of reabsorption and the intrinsic quantum efficiency has been estimated. Lasing has been demonstrated near 1074 nm with 41% slope efficiency at room temperature using a 0.5 mm thin plate of KYbW. This laser material holds great promise for diode pumped high-power lasers, thin disk and waveguide designs as well as for ultrashort (ps/fs) pulse laser systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To explore the role of pro-apoptotic signals following tissue injury and how these may promote a progression of further cell death. METHODS: Laser treated porcine articular cartilage disks were maintained in culture media. The collected media at various time periods (3, 6, 9, 12, 24 and 48 h), was called treated conditioned media (TCM). Non-laser treated cartilage disks were used to create control conditioned media (CCM). Each disk was subsequently maintained for 28 days and used in confocal microscopic assessment to document the progression of the damaged area. Isolated porcine chondrocytes were cultured in monolayer, and were exposed to TCM, CCM or normal culture medium (NM). As a positive inducer of apoptosis, the monolayer cells were exposed to UV radiation for 10 min and cultured in NM. Following 24 h exposure, the cells were harvested and stained with the appropriate combination of fluorescent dyes and processed via flow cytometry. RESULTS: All cultured cells exposed to TCM displayed a caspase-3 positive subpopulation, a loss of CMXRos, and with a reduced or lost NO signal. CCM exposure signals were comparable to the NM treatments with all having retained CMXRos, NO and without evidence of caspase-3 activity. UV treatment also induced a reduction in NO, but both CMXRos and caspase-3 positive, representing an earlier stage of apoptosis and suggesting that the mode of cell death via UV and TCM exposure are via different processes. The investigation of a dose (100%, 50%, 25% and 12.5%) and time (0.5, 1, 3, 9, 12 h) response to TCM exhibited that all treatments observed an increase in caspase-3 positive cells and a reduction in NO and CMXRos. CONCLUSION: The usefulness of FCM can be used in the study of cell viability and apoptosis. Such a system may be useful in the study of mechanisms of disease such as osteoarthritis, thus may be of practical use for the pharmaceutical industry for screening associated drugs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Geometric scaling of a Kerr-lens mode-locked Yb:YAG thin-disk oscillator yields femtosecond pulses with an average output power of 270 W. The scaled system delivers femtosecond (210-330 fs) pulses with a peak power of 38 MW. These values of average and peak power surpass the performance of any previously reported femtosecond laser oscillator operated in atmospheric air.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last decade, vertical-external-cavity surface-emitting lasers (VECSELs) have become promising sources of ultrashort laser pulses. While the mode-locked operation has been strongly relying on costly semiconductor saturable-Absorber mirrors for many years, new techniques have been found for pulse formation. Mode-locking VECSELs are nowadays not only achievable by using a variety of saturable absorbers, but also by using a saturable-Absorber-free technique referred to as self-mode-locking (SML), which is to be highlighted here.