37 resultados para DesignBuilder
Resumo:
This paper reports on a new façade system that uses passive solutions in the search for energy efficiency. The differentials are the versatility and flexibility of the modules, which are important advantages of the system. The thermal performance of Trombe walls and glazings and the daylighting performance of glazing were the key aspects analyzed in the results. Computational simulations were accomplished for the thermal performance of different arrangements of the modules with DesignBuilder software. The glazing daylighting performance was studied by means of Ecotect and Desktop Radiance programs and compared with the transmittance curves of glazings. Occupancy profile and internal gains were fixed according to the Portuguese reality for both studies. The main characteristics considered in this research were the use of two double glazings, four different climates in Portugal and one and two Trombe walls in the façade. The results show an important reduction in the energy consumption with the use of Trombe walls and double self-cleaning glazing in the façade, which also presented better daylighting performance.
Resumo:
Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces
Resumo:
This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity
Resumo:
The assessment of building thermal performance is often carried out using HVAC energy consumption data, when available, or thermal comfort variables measurements, for free-running buildings. Both types of data can be determined by monitoring or computer simulation. The assessment based on thermal comfort variables is the most complex because it depends on the determination of the thermal comfort zone. For these reasons, this master thesis explores methods of building thermal performance assessment using variables of thermal comfort simulated by DesignBuilder software. The main objective is to contribute to the development of methods to support architectural decisions during the design process, and energy and sustainable rating systems. The research method consists on selecting thermal comfort methods, modeling them in electronic sheets with output charts developed to optimize the analyses, which are used to assess the simulation results of low cost house configurations. The house models consist in a base case, which are already built, and changes in thermal transmittance, absorptance, and shading. The simulation results are assessed using each thermal comfort method, to identify the sensitivity of them. The final results show the limitations of the methods, the importance of a method that considers thermal radiance and wind speed, and the contribution of the chart proposed
Resumo:
The building envelope is the principal mean of interaction between indoors and environment, with direct influence on thermal and energy performance of the building. By intervening in the envelope, with the proposal of specific architectural elements, it is possible to promote the use of passive strategies of conditioning, such as natural ventilation. The cross ventilation is recommended by the NBR 15220-3 as the bioclimatic main strategy for the hot and humid climate of Natal/RN, offering among other benefits, the thermal comfort of occupants. The analysis tools of natural ventilation, on the other hand, cover a variety of techniques, from the simplified calculation methods to computer fluid dynamics, whose limitations are discussed in several papers, but without detailing the problems encountered. In this sense, the present study aims to evaluate the potential of wind catchers, envelope elements used to increase natural ventilation in the building, through CFD simplified simulation. Moreover, it seeks to quantify the limitations encountered during the analysis. For this, the procedure adopted to evaluate the elements implementation and efficiency was the CFD simulation, abbreviation for Computer Fluid Dynamics, with the software DesignBuilder CFD. It was defined a base case, where wind catchers were added with various settings, to compare them with each other and appreciate the differences in flows and air speeds encountered. Initially there has been done sensitivity tests for familiarization with the software and observe simulation patterns, mapping the settings used and simulation time for each case simulated. The results show the limitations encountered during the simulation process, as well as an overview of the efficiency and potential of wind catchers, with the increase of ventilation with the use of catchers, differences in air flow patterns and significant increase in air speeds indoors, besides changes found due to different element geometries. It is considered that the software used can help designers during preliminary analysis in the early stages of design
Resumo:
This paper evaluates the thermal and luminous performance of different louver configurations on an office room model located in Maceió-AL (Brazil), ranking the alternatives in a way that leads to choices for alternatives with potential balanced performance. Parametric analyses were done, based on computer simulations on software Troplux 5 and DesignBuilder 2. The variables examined were number of slats, slat slope and slat reflectance, considering the window facing North, South, East and West and a fixed shading mask for each orientation. Results refer to internal average illuminance and solar heat gains through windows. It was observed that configurations of shading devices with the same shading mask may have different luminous and thermal performance. The alternatives were ranked, so the information here produced has the potential to support decisions on designing shading devices in practice.
Resumo:
Within the building energy saving strategies, BIPV (building integrated photovoltaic systems) present a promising potential based on the close relationship existing between these multifunctional systems and the overall building energy balance. Building integration of STPV (semi-transparent photovoltaic) elements affects deeply the building energy demand since it influences the heating, cooling and lighting loads as well as the local electricity generation. This work analyses over different window-to-wall ratios the overall energy performance of five STPV elements, each element having a specific degree of transparency, in order to assess the energy saving potential compared to a conventional solar control glass compliant with the local technical standard. The prior optical characterization, focused to measure the spectral properties of the elements, was experimentally undertaken. The obtained data were used to perform simulations based on a reference office building using a package of specific software tools (DesignBuilder, EnergyPlus, PVsyst, and COMFEN) to take proper account of the STPV peculiarities. To evaluate the global energy performance of the STPV elements a new Energy Balance Index was formulated. The results show that for intermediate and large façade openings the energy saving potential provided by the STPV solutions ranges between 18% and 59% compared to the reference glass.
Resumo:
Os edifícios de balanço energético nulo (NZEB - Net-Zero Energy Building) e/ou quase nulo (nZEB), têm vindo a ganhar crescente atenção desde a publicação da diretiva europeia 2010/31/EU [15]. Em Portugal, com a introdução do Decreto-Lei n.º118/2013, dá o primeiro passo para os edifícios com necessidades quase nulas de energia. Os novos edifícios licenciados após 31 dezembro de 2020, ou após 31 de dezembro de 2018 no caso de edifícios públicos, serão edifícios com necessidades quase nulas de energia. O objetivo do trabalho descrito neste artigo consiste na aplicação do conceito ”Net Zero Energy Building”, ao edifício existente do Instituto Superior Politécnico Gaya (ISPGaya), em Vila Nova de Gaia, com o intuito de analisar a viabilidade de otimização de energia e a metodologia deste conceito ao edifício, com recurso a ferramentas de simulação. Neste trabalho efetuámos uma simulação energética do edifício, através do DesignBuilder®, que servirá como termo de comparação para outras simulações. Serão delineadas as especificações a implementar no edifício por forma a ser considerado Net Zero Energy Building, com alterações na simulação do mesmo de acordo com as novas especificações. Por último, será feita a comparação técnica, financeira e ambiental da solução NZEB encontrada. Através das várias simulações energéticas ao edifício, conclui-se que é possível baixar as necessidades energéticas do edifício através de medidas de eficiência energética, em especial na iluminação e que os resultados obtidos, apesar de ser viável a implementação do conceito Net Zero Energy Building, traduzem um esforço financeiro e algumas condicionantes para a sua concretização.
Resumo:
This paper addresses the theme of retrotif applied to buildings that belong to the modernist architectural production of historical interest located in the urban area of Natal . The overall objective is to identify and harmonize procedures for retrofit and architectural heritage preservation using elements of constructive analysis of expression and Benefit Cost Ratio ( BCR ) parameters established by the National Electric Energy Agency - ANEEL . The hypothesis put forward is that by stimulating the projetual year analysis , retrofit interventions , it is possible to obtain better results with projects RCB addressing the issues of preservation of architectural heritage . For both flow analysis of process solutions and proposals for action of elements and systems that seek to improve the energy performance of the building , restoring or preserving the architectural elements were developed . The proposed interventions undergo performance through computer simulations of systems such as DesignBuilder, Solar and Sun Tool. The energy results were converted to the analysis of RCB parameter and compared to the constructive expression of the project because the prenatal and intervention. From the results , a plot was constructed which results in a comparison between the RCB and the constructive expression of the simulated interventions
Resumo:
This work consists of the integrated design process analyses with thermal energetic simulation during the early design stages, based on six practical cases. It aims to schematize the integration process, identifying the thermal energetic analyses contributions at each design phase and identifying the highest impact parameters on building performance. The simulations were run in the DesignBuilder energy tool, which has the same EnergyPlus engine, validated. This tool was chosen due to the flexible and user friendly graphic interface for modeling and output assessment, including the parametric simulation to compare design alternatives. The six case studies energy tools are three architectural and three retrofit projects, and the author the simulations as a consultant or as a designer. The case studies were selected based on the commitment of the designers in order to achieve performance goals, and their availability to share the process since the early pre-design analyses, allowing schematizing the whole process, and supporting the design decisions with quantifications, including energy targets. The thermoenergetic performance analyses integration is feasible since the early stages, except when only a short time is available to run the simulations. The simulation contributions are more important during the sketch and detail phases. The predesign phase can be assisted by means of reliable bioclimatic guidelines. It was verified that every case study had two dominant design variables on the general performance. These variables differ according the building characteristics and always coincide with the local bioclimatic strategies. The adaptation of alternatives to the design increases as earlier it occurs. The use of simulation is very useful: to prove and convince the architects; to quantify the cost benefits and payback period to the retrofit designer; and to the simulator confirm the desirable result and report the performance to the client
Resumo:
Este trabalho visa analisar o potencial do sombreamento vegetal no edifício para promover conforto térmico, luminoso e eficiência energética, a partir de simulações computacionais nos softwares DesignBuilder e Daysim. Foram simuladas diferentes combinações de fator de céu visível (FCV), transparência da copa vegetal e percentual de abertura da fachada (PAF) para edificação residencial térrea em Nata/RN, a fim de quantificar os impactos e propor recomendações projetuais. Os modelos foram analisados por meio do método de conforto adaptativo indicado pela ASHRAE Standard 55 (ASHRAE, 2010), classificação do nível de eficiência energética do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Residenciais (RTQ-R), resultados de Daylight autonomy (DA) e uniformidade da luz natural para as exigências lumínicas de 100-300-500 lux. Os resultados demonstram grande potencial para integração da vegetação na edificação, principalmente para os fatores de céu médio e grande, e falta de coerência do RTQ-R para classificar as edificações da Zona bioclimática 08 pelo método de simulação.
Resumo:
Este trabalho visa analisar o potencial do sombreamento vegetal no edifício para promover conforto térmico, luminoso e eficiência energética, a partir de simulações computacionais nos softwares DesignBuilder e Daysim. Foram simuladas diferentes combinações de fator de céu visível (FCV), transparência da copa vegetal e percentual de abertura da fachada (PAF) para edificação residencial térrea em Nata/RN, a fim de quantificar os impactos e propor recomendações projetuais. Os modelos foram analisados por meio do método de conforto adaptativo indicado pela ASHRAE Standard 55 (ASHRAE, 2010), classificação do nível de eficiência energética do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Residenciais (RTQ-R), resultados de Daylight autonomy (DA) e uniformidade da luz natural para as exigências lumínicas de 100-300-500 lux. Os resultados demonstram grande potencial para integração da vegetação na edificação, principalmente para os fatores de céu médio e grande, e falta de coerência do RTQ-R para classificar as edificações da Zona bioclimática 08 pelo método de simulação.
Resumo:
Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces
Resumo:
No panorama energético atual, medidas de desenvolvimento sustentável têm uma preponderância cada vez mais significativa e, sendo os edifícios responsáveis por 40% da energia consumida na EU, enquadra-se o desafio de integrar medidas de eficiência energética nos novos edifícios desde a fase de conceção. Sendo que este setor se encontra em contínua expansão, a redução dos consumos passará largamente pela otimização do comportamento térmico dos edifícios e dos sistemas energéticos que os equipam. No presente trabalho estudou-se o papel da inércia térmica na redução das necessidades de energia para climatização de edifícios com o objetivo de identificar estratégias destinadas ao melhoramento do comportamento térmico e desempenho energético de edifícios construídos com recurso à técnica construtiva LSF, caracterizados por uma fraca inércia térmica quando comparados com edifícios em tudo semelhantes mas construídos recorrendo a tecnologias convencionais sem esquecer as questões relacionadas com a respetiva viabilidade económica. Com resultado geral destaca-se desde logo a importância do local onde é mais benéfico adicionar massa térmica (paredes exteriores, cobertura, paredes interiores), assim como a necessidade de utilização de um material com elevada densidade energética e baixo custo. A análise comparativa dos diferentes modelos de edifício simulados com recurso ao software DesignBuilder/EnergyPlus, foi realizada recorrendo a uma metodologia em que cada modelo construtivo é avaliado considerando quatro níveis de isolamento térmico e duas condições de cargas térmicas internas. A análise energética e económica foi realizada tendo como referência um período de 20 anos. O custo das soluções construtivas foi maioritariamente obtido através da ferramenta computacional Gerador de Preços, da Cype, SA©, tendo-se considerado um consumo energético anual constante e igual às necessidades de climatização anuais, assim como taxas de atualização de capital e de inflação do custo da energia constantes. De uma forma geral conclui-se que edifícios do tipo LSF melhorados através da adição criteriosa de massa térmica em determinados elementos construtivos, apresentam necessidades de climatização anuais na maioria dos casos estudados, inferiores àquelas verificadas em edifícios convencionais com inércia térmica média/forte. Conclui-se, também, que o método construtivo LSF se apresenta mais eficaz em termos energéticos e económicos quando comparado com soluções semelhantes construídas com recurso a um método convencional. Na secção seguinte são identificadas as principais conclusões deste trabalho.
Resumo:
This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity