988 resultados para Dentin tubules
Resumo:
The aim of this study was to evaluate the penetration of endodontic sealer into the dentin tubules, the integrity of the sealer layer perimeter, and the sealer area at the apical third after different filling techniques by confocal laser scanning microscopy (CLSM). Forty-five mandibular premolars were mechanically prepared with ProTaper files, until F5 file. Thereafter, they were filled with an epoxy-resin sealer (AH Plus) mixed with Rhodamine B dye (0.1% proportion) and allocated in three groups: Group 1, single master cone; Group 2, cold lateral compaction; and Group 3, Thermafil. For confocal laser scanning microscopy analysis, the specimens were transversely sectioned at 4 mm from the apex. The images at x10 and x40 were analyzed by Imagetool 3.0 software. Significant differences were not found among the three experimental groups according the dentin-impregnate area by the sealer (P = 0.68) and between the sealer and root canal perimeter (P = 0.18). However, root canal filling techniques were significantly different when apical sealer areas were compared (P = 0.001). Thermafil group showed smaller sealer areas (8.09%) while cold lateral compaction and gutta-percha master cone showed similar areas (17.37 and 21.18%, respectively). The dentin-impregnated area was not dependent on the root canal filling technique. Single master cone, cold lateral condensation and Thermafil techniques presented integrity of the sealer perimeter close to 100% and Thermafil resulted in a significantly thinner sealer layer. Microsc. Res. Tech. 75:12771280, 2012. (C) 2012 Wiley Periodicals, Inc.
Resumo:
Fourier-transform (FT)-Raman and -infrared (IR) spectroscopy were employed to investigate the function of the aqueous 2-hydroxyethylmethacrylate/glutaraldehyde solution (Gluma) as a desensitizer. 2-Hydroxyethylmethacrylate (HEMA), glutaraldehyde (GA), and the mixture of HEMA/GA (i.e. Gluma) were used to interact with dentin, collagen, hydroxyapatite (HAP), and bovine serum albumin (BSA) individually. All the interactions were monitored by an FT-Raman spectrometer. FT-IR spectroscopy was also used in this study. The results show that HEMA could be absorbed by dentin and collagen; GA could cross-link collagen and BSA; and when BSA was added to Gluma, polymerization of HEMA occurred. The results suggest that Gluma acts as a desensitizer whereby, first, GA reacts with part of the serum albumin in dentinal fluid, which induces a precipitation of serum albumin, then, second, a reaction of GA with serum albumin induces polymerization of HEMA. The function of Gluma as a desensitizer to block dentinal tubules occurs via these two reactions.
Resumo:
Dentin hypersensitivity is a common condition associated with high dental pain. A new LED-based (light emitting diode) light source has been used as an experimental tool in some studies. Purpose: The main objective was to compare these two light sources emitting in the same spectral band (red from 625 to 660 nm) to promote pain relief. Material and methods: A total of 6 sessions were accomplished, being three irradiation sessions and three follow-up sessions. This single-blind study compared a control group (Placebo) and two other groups with different equipments: low laser intensity treatment (LILT) and a light emitting diode system treatment (LEDT). Results: The results showed that there is no statistical difference between LILT and LEDT groups, however, both were better than control group (p=0.01) in terms of treatment efficiency; there is no difference between the second and the third sessions for both treatment, it means that the third session was not necessary; finally, the improvement at the end of the entire research (follow up care of 30 days) was very expressive in comparison to pre-treatment situation for all teeth (p=0.01). Conclusion: LILT and LEDT were equally effective to treat dentine hypersensitivity, a 3rd treatment session was not necessary/two sessions are enough.
Resumo:
This study demonstrated that a significant number of bacteria is present. in the radicular dentinal tubules of periodontally diseased human teeth. Ten periodontally diseased teeth were prepared and stained by Brown and Brenn technique for histological examination. Bacteria were detected in all teeth. It is suggested that bacteria may invade dentinal tubules exposed to periodontal pocket and are very hard to be eliminated by conventional mechanical and chemical periodontal therapy. Contaminated dentinal tubules of periodontally diseased teeth can thus act as active bacterial reservoirs to promote recolonization of mechanically treated root surfaces, which could interfere with the periodontal healing and progression of the disease.
Resumo:
Objectives. To evaluate the response of the pulpo-dentin complex following application of a resin-modified glass-ionomer cement or an adhesive system in deep cavities performed in human teeth.Methods. Deep class V cavities were prepared on the buccal surface of 26 premolars. In Group I the cavity walls (dentin) and enamel were conditioned with 32% phosphoric acid and the dentin adhesive system One Step (Bisco, Inc., Itasca, IL, USA) was applied. In Groups 2 and 3, before total etching and application of bonding agent, the cavity floor was lined with the resin-modified glass-ionomer cement-Vitrebond (3M ESPE Dental Products Division, St. Paul, MN, USA) or the calcium hydroxide cement-Dycal (control group, Dentsply, Mildford, DE, USA), respectively. The cavities were restored using light-cured Z-100 composite resin (3M ESPE). The teeth were extracted between 5 and 30 days and prepared for microscopic assessment. Serial sections were stained with H/E, Masson's trichrome, and Brown and Brenn techniques.Results. In Group 1, the inflammatory response was more evident than in Groups 2 and 3. Diffusion of dental material components across dentinal tubules was observed only in Group 1, in which the intensity of the pulp response increased as the remaining dentin thickness decreased. Bacteria were evidenced in the lateral walls of two samples (Group 2) which exhibited no inflammatory response or tissue disorganization.Conclusions. Based on the experimental conditions, it was concluded total acid etching followed by application of One Step bonding agent cannot be recommended as adequate procedures. In this clinical condition the cavity walls should be lined with a biocompatible dental material, such as Vitrebond or Dycal. 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To analyze the smear layer and the hybrid layer in noncarious and carious dentin prepared by different cutting instruments and restored with composite resin. Study design: Cavities were randomly prepared in 160 specimens (noncarious and artificial carious dentin) by high-speed diamond tips (KG Sorensen 1013), air abrasion system (Prepstart, Danville Engineering), ultrasonic tip (CVDentus 8.3231-1), and ultrasonic tip associated with ultrasonic cavitation by water for 10 s. Half of the cavities in each group were conditioned with 37% phosphoric acid for 15 s. The amount of smear layer and dentinal tubules present were analyzed using scanning electron microscopy and graded from 0 to 3. Cavities were prepared in another 20 noncarious specimens and 20 carious specimens and restored with adhesive composite resin system. The restorations were hemisected longitudinally and analyzed using scanning electron microscopy to evaluate the hybrid layer and resinous prolongation characteristics, using scores ranging from 1 to 6. Results: The data were statistically analyzed using Kruskal-Wallis and Dunn tests at 5% of significance level. There was evidence that the most efficient smear layer removal was the acid etching in the noncarious dentin and the water ultrasonic cavitation in the carious dentin. The hybrid layer formed on the noncarious and carious dentin prepared by the ultrasonic tip was more regular than in the specimens prepared by high-speed diamond tip, with many resinous prolongations. Conclusion: The ultrasonic tip seems to be a promising tool for carious dentin cavity preparation. Microsc. Res. Tech. 73:597-605, 2010. (C) 2009 Wiley-Liss, Inc.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study evaluated comparatively by scanning electron microscopy (SEM) the effect of different dental conditioners on dentin micromorphology, when used according to the same protocol. Forty dentin sticks were obtained from 20 caries-free third human molars and were assigned to 4 groups corresponding to 3 conditioners (phosphoric acid 37%, Clearfil SE Bond and iBond) and an untreated control group. After application of the conditioners, the specimens were immersed in 50% ethanol solution during 10 s, chemically fixed and dehydrated to prepare them to SEM analysis. In the control group, dentin surface was completely covered by smear layer and all dentinal tubules were occluded. In the phosphoric acid-etched group, dentin surface was completely clean and presented exposed dentinal tubule openings; this was the only group in which the tubules exhibited the funnel-shaped aspect. In the groups conditioned with Clearfil SE Bond primer and iBond, which are less acidic than phosphoric acid, tubule openings were occluded or partially occluded, though smear layer removal was observed. SE Bond was more efficient in removing the smear layer than iBond. In the Clearfil SE Bond group, the cuff-like aspect of peritubular dentin was more evident. It may be concluded all tested conditioners were able to change dentin morphology. However, it cannot be stated that the agent aggressiveness was the only cause of the micromorphological alterations because a single morphological pattern was not established for each group, but rather an association of different aspects, according to the aggressiveness of the tested conditioner.
Resumo:
Background and Objectives. The adhesion of dental materials is important for the success of treatment. The aim of this study is to evaluate the bond strength of a composite resin applied with a self-etching adhesive system in different dentins after irradiation with Er:YAG and Nd:YAG lasers, observing their morphologic pattern using Scanning Electronic Microscopy (SEM). Materials and Methods. The buccal surface of 72 bovine incisors was worn until exposure of medium depth dentin. The specimens were divided into three groups; GI: normal, GII: demineralized and GIII: hypermineralized dentin. These were also divided into two subgroups; A-irradiated for 30 s with Er:YAG laser in noncontact mode at 40 mJ and 6 Hz and B- irradiated for 30 s with Nd:YAG laser in contact mode at 60 mJ and 10 Hz. The adhesive system Clearfil SE. Bond (Kuraray) and composite resin Tetric Ceram (Vivadent) were applied on the irradiated area by the incremental technique. After storage for 24 h in distilled water at 37 degrees C, the specimens were submitted to the shear strength test in a universal testing machine (EMIC) at a crosshead speed of 1.0 mm/min. Other specimens were made to be analyzed by SEM. Results. The results were statistically analyzed by Analysis of Variance and the Tukey test. Regardless of the type of dentin, the bond strength of specimens irradiated with the Nd:YAG laser (8,94 +/- 2,07) was higher compared to specimens irradiated with the Er:YAG laser (7,03 +/- 2,47); the highest bond strength was obtained for the group of hypermineralized dentin irradiated with the Nd:YAG laser. The SEM analysis showed that the Er:YAG laser caused opening of tubules and the Nd:YAG laser produced areas of fusion as well as regions of opening of dentinal tubules. Conclusions. The dentin showed different morphological patterns and the laser promote alterations on their surfaces, influencing the bond strength of the composite resin. (C) 2010 Laser Institute of America.
Resumo:
Objective: the purpose of this study is to make use of scanning electron microscopy in order to comparatively analyze the morphological alterations to human and bovine enamel and dentin. Earlier data: Many a morphological study involving Er:YAG laser can be found in the literature. Still, not a single study comparing the effects of this infrared laser in human and bovine teeth has been reported. Materials and Methods: Thirty-two slices of human and bovine enamel and dentin were evenly divided into four groups. With the exception of the control group, the samples were irradiated with Er:YAG laser, focused at a distance of 12 mm and a 10-Hz frequency, with 150, 250, and 350 mJ of output energy per pulse for 10 seconds. After irradiation all specimens were observed under a scanning electron microscope. Results: There was practically no morphological difference for those samples that underwent 150 mJ/pulse irradiation. The dentin exposed to 250 mJ had a few open dentinal tubules. These were seen in enamel after a 350 mJ irradiation, in which the energy was able to reach the dentin. Conclusions: the breadth of this study allows us to state that the pattern between the species grew more heterogenous as the energy density was increased and that irradiation with 150 mJ/pulse resulted in greater likeness in human and bovine enamel and dentin.
Resumo:
This study was conducted to observe the rat subcutaneous connective tissue reaction to the implanted dentin tubes filled with calcium hydroxide or mineral trioxide aggregate. The animals were sacrificed after 7 and 30 days, and the specimens were prepared for morphological study. Some undecalcified specimens were prepared for histological analysis with polarized light and Von Kossa technique for calcium. The results were similar for both studied materials. At the tube openings, there were Von Kossa-positive granules that were birefringent to polarized light. Next to these granulations, there was an irregular tissue like a bridge that was Von Kossa-positive. The dentin walls of the tubes exhibited in the tubules a structure highly birefringent to polarized light, usually like a layer and at different depths. It is possible that the mechanism of action of both materials has some similarity. Copyright © 1999 by The American Association of Endodontists.
Resumo:
The subject of this study was to observe the rat subcutaneous connective tissue reaction to implanted dentin tubes filled with mineral trioxide aggregate, Portland cement or calcium hydroxide. The animals were sacrificed after 7 or 30 days and the undecalcified specimens were prepared for histological analysis with polarized light and Von Kossa technique for mineralized tissues. The results were similar for the studied materials. At the tube openings, there were Von Kossa-positive granules that were birefringent to polarized light. Next to these granulations, there was an irregular tissue like a bridge that was Von Kossa-positive. The dentin walls of the tubes exhibited in the tubules a structure highly birefringent to polarized light, usually like a layer and at different depths. The mechanism of action of the studied materials has some similarity.
Resumo:
The purpose of this paper was to study the reaction of rat subcutaneous connective tissue to the implantation of dentin tubes filled with white mineral trioxide aggregate (MTA), a material that will be marketed. The tubes were implanted into rat subcutaneous tissue and the animals were sacrificed after 7 and 30 days. The undecalcified pieces were prepared for histological analysis with polarized light and von Kossa technique for mineralized tissues. Granulations birefringent to polarized light and an irregular structure like a bridge were observed next to the material; both were von Kossa positive. Also, in the dentin wall tubules a layer of birefringent granulations was observed. The results were similar to those reported for gray MTA, indicating that the mechanisms of action of the white and gray MTA are similar.
Resumo:
Dentin hypersensitivity is a common painful condition observed in clinics. Dietary habits have been much associated with its development and persistence during and following periodontal treatment. The aim of this in vitro study was to evaluate the influence of vinegars on the removal of smear layer and exposure of dentinal tubules. Extracted human teeth were submitted to manual scaling with Gracey curettes in order to remove the cementum as well as to form a smear layer. Dentin samples with 3 mm(2) were obtained and distributed into six experimental groups: one control and five types of vinegars (alcohol, apple, rice, white wine and balsamic). Each group included two methods of vinegar application: topical and friction. After routine preparation for SEM analysis, photomicrographs were assessed by a calibrated and blind examiner using an appropriate index system. Kruskal-Wallis test indicated a significant influence of vinegars on smear layer removal. There was a statistically significant difference between groups treated with apple, white and rice vinegars and the control group (p < 0.05). Nevertheless, Mann-Whitney test indicated that removal of smear layer did not vary with the method of application (topical versus friction) for any of the tested substances. We can conclude that the contact of vinegar may remove smear layer and expose dentinal tubules, regardless of the type of application. However, balsamic vinegar was associated with less removal of smear layer after both methods of application.
Resumo:
The aim of this study was to evaluate the ability of endotoxin to diffuse through dentinal tubules towards the cement and to observe the period of time needed for it to reach the external root surface. Thirty single-rooted human teeth had their crowns and apices removed in order to standardize the root length to 15 mm. Teeth were instrumented until #30 K-file and made externally impermeable with epoxy adhesive, leaving 10 mm of the exposed root (middle third). The specimens were placed in plastic vials and irradiated (60Co gamma-rays). Then, they were divided into 2 groups (n = 15): G1) Escherichia coli endotoxin was inoculated into the root canal of the specimens and 1 ml of pyrogen-free water was put in the tubes; G2) (control): pyrogen-free water was inoculated into the root canals and 1 ml of pyrogen-free water was put in each tube. After 30 min, 2 h, 6 h, 12 h, 24 h, 48 h, 72 h and 7 days, the water of the tubes was removed and replaced. The removed aliquot was tested for the presence of endotoxin. Considering that the endotoxin is a B-lymphocyte polyclonal activator, at each experimental period, B-lymphocyte culture was stimulated with a sample of water removed from each tube and antibody (IgM) production was detected by ELISA technique. The results of IgM production were higher in groups of 24 h, 48 h, 72 h and 7 days in relation to the other studied groups, with statistically significant differences (ANOVA and Tukey's test p < 0.05). Endotoxin was able to diffuse through the dentinal tubules towards the cement, reaching the external root surface after the period of 24 h.