964 resultados para Dental Equipment


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Water from dental equipment presents risks for surgeon-dentists as well as for patients because it might work as a means of dissemination/ transmission of microoganisms. The objective of this study was to verify the quality of the water used in dental equipment by means of microbiological analysis, accomplishing the count of Staphylococcus spp.There have been collected, 160 samples of water from reserviors, taps used for hand washing, air-water syringes, and high-speed handpieces, in 40 dental offices in the city of Barretos, São Paulo. The rules concerning bacteriotogicaI analysis in cfu/mL from Standard Methods for the Examination of Water and Wastewater have been followed. The analysis of the results has made it possible to verify that out of the total of samples, 28% did not meet the standards of potability established by the American Dental Association: Regarding the origin of analyzed S. aureus., the most contaminated sites were high-speed handpicces in private offices (761%) and in, ental care plan offices (71%), followed by air-water syringe in dental care plan offices (64%). For S. epidermitis samples, the most contaminated sites were high-speed handpieces in SUS (Brazilian Government Health System) dental offices (22%) and in dental care plan offices (14%) The most contaminated sites were dental offices that saw Patients under dental care plans, Concerning tested antibiotics, the ones that presented better results as to sensibility to strain S. epidermidis were vancomycin and ciprofloxacin (100%) and, as to sensibility to strain S. aureus, it was ciprofloxacin (97%).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: Treatment of periodontal diseases is based on efficient scaling and root planing (SRP) and adequate maintenance of the patient. The effectiveness of SRP is influenced by operator skill, access to the subgingival area, root anatomy, and the quality and type of instrument used for SRP. The aim of this study was to evaluate the cutting edges of Gracey curettes after manufacturing and after resharpening using several techniques. Methods and Material: The cutting edges of a total of 41 new #5-6 stainless steel Gracey curettes were evaluated blindly using scanning electron microscopy (SEM). The quality of the cutting edges was evaluated blindly by a calibrated examiner using micrographs. Data were analyzed using a Kruskal Wallis test and nonparametric two-way multiple comparisons. Results and Conclusions: Different sharpening techniques had significantly different effects on the sharpeness of cutting edges (p<0.05). Sharpening by passing the lateral face of curettes over a sharpening stone and then a #299 Arkansas stone produced a high frequency of smooth, sharp edges or slightly irregular edges between the lateral and coronal faces of the curettes. Sharpening by passing a blunt stone over the curette's lateral face produced the poorest quality cutting edge (a bevel). Sharpening of the coronal curette face produced extremely irregular cutting edges and non-functional wire edges. Sharpening with rotary devices produced extremely irregular cutting edges.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study quantified by, electrovibratography, the amount of mandible protrusion required to decrease significantly temporomandibular joint (TMJ) vibratory energy as an aid in the diagnosis of the recapture of anteriorly displaced disk. Eighteen patients diagnosed as having anterior disk displacement with reduction and TMJ clicking were submitted to electrovibratographic examination at the first appointment and treated with a stabilizing appliance and anterior positioning appliance with 1 to 5 mm protrusion. Vibratory energy was checked in each of these positions. Baseline data were used as control. At the first appointment, the patients had vibrations with more elevated intensities at the middle and late phases of the mouth opening cycle. At only one clinical step, mandible protrusion was obtained with the anterior repositioning appliance, ranging from 1 to 5 mm protusion. At each new position, a new electrovibratographic exam was made. After the 5-mm mandibular projection, only 2 patients presented vibration, with means between 0.6 and 2.8 Hz. Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). The outcomes of this study indicate that 3 mm is the minimum amount of mandible protrusion to significantly decrease the TMJ vibratory energy and to recapture the displaced articular disk.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The technique presented in this article presents a protocol for treatment that reduces the time required for the fabrication and placement of an implant supported prosthesis. It also offers improved patient comfort at a lower cost when compared to conventional technology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study evaluated by cone-beam computed tomography (CBCT) the apical canal transportation and centralizing ability of different automated systems after root canal preparation. The mesiobuccal canals of maxillary first molars (n=10 per group) were prepared with: GI - reciprocating system with K-Flexofile; GII - reciprocating system with NiTiFlex files; GIII - rotary system with K3 instruments; GIV - rotary system with RaCe instruments. CBCT scans were taken before and after biomechanical preparation up to a #40.02 diameter. Canal transportation was determined by measuring the smallest distance between the inner canal walls and the mesial and distal sides of the root. The centralization ability corresponded to the difference between the measurements from transportation evaluation, using the linear voxel to voxel method of analysis. The mean transportation was 0.06 ± 0.14 mm, with a tendency to deviate to the mesial side of the root (n=22), with no statistically significant difference among the groups (p=0.4153). The mean centralization index was 0.15 ± 0.65 also without statistically significant difference among the groups (p=0.0881). It may be concluded that apical canal transportation and centralization ability were not influenced by the type of mechanical movement and instruments used.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the Knoop hardness of a dual-cured resin cement (Rely-X ARC) activated solely by chemical reaction (control group) or by chemical / physical mode, light-cured through a 1.5 mm thick ceramic (HeraCeram) or composite (Artglass) disc. Light curing was carried out using conventional halogen light (XL2500) for 40 s (QTH); light emitting diodes (Ultrablue Is) for 40 s (LED); and Xenon plasma arc (Apollo 95E) for 3 s (PAC). Bovine incisors had their buccal face flattened and hybridized. On this surface a rubber mold (5 mm in diameter and 1 mm in height) was bulk filled with the resin cement. A polyester strip was seated for direct light curing or through the discs of veneering materials. After dry storage in the dark (24 h 37°C), the samples (n = 5) were sectioned for hardness (KHN) measurements, taken in a microhardness tester (50 gF load 15 s). The data were statistically analyzed by ANOVA and Tukey's test (α = 0.05). The cement presented higher Knoop hardness values with Artglass for QTH and LED, compared to HeraCeram. The control group and the PAC/Artglass group showed lower hardness values compared to the groups light-cured with QTH and LED. PAC/HeraCeram resulted in the worst combination for cement hardness values. © 2009 Sociedade Brasileira de Pesquisa Odontológica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this in vitro study was to compare the photoactivation effects of QTH (Quartz-Tungsten-Halogen) and LED (Light-Emitting Diode) on the SBS (Shear Bond Strength) of orthodontic brackets at different debond times. Seventy-two bovine lower incisors were randomly divided into two groups according to the photoactivation system used (QTH or LED). The enamel surfaces were conditioned with Transbond self-etching primer, and APC (Adhesive Pre-Coated) brackets were used in all specimens. Group I was cured with QTH for 20 s and Group II with LED for 10 s. Both groups were subdivided according to the different experimental times after bonding (immediately, 24 h and 7 days). The specimens were tested for SBS and the enamel surfaces were analyzed according to the Adhesive Remnant Index (ARI). The statistical analysis included the Tukey's test to evaluate the main effects of photoactivation and debond time on SBS. The Chi-square test was used to compare the ARI values found for each group, and no statistically significant difference was observed. The debond time of 7 days for QTH photoactivation showed statistically greater values of SBS when compared to the immediate and 24 h periods. There was no statistically significant difference between the QTH and LED groups immediately and after the 24 h period. In conclusion, bonding orthodontic brackets with LED photoactivation for 10 s is suggested because it requires a reduced clinical chair time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the effect of different light energy densities on conversion degree (CD) and Knoop hardness number (KHN) of RelyX ARC (RLX) resin cement. After manipulation according to the manufacturer's instructions, RLX was inserted into a rubber mold (0.8 mm X 5 mm) and covered with a Mylar strip. The tip of the lightcuring unit (LCU) was positioned in contact with the Mylar surface. Quartz-tungsten-halogen (QTH) and light-emitting diode (LED) LCUs with light densities of 10, 20 and 30 J/cm2 were used to light-cure the specimens. After light curing, the specimens were stored dry in lightproof containers at 37°C. After 24 hours, the CD was analyzed by FT-Raman and, after an additional 24-hours, samples were submitted to Knoop hardness testing. The data of the CD (%) and KHN were submitted to two-way ANOVA and the Tukey's test (α=0.05). QTH and LED were effective light curing units. For QTH, there were no differences among the light energy densities for CD or KHN. For LED, there was a significant reduction in CD with the light energy density set at 10 J/cm2. KHN was not influenced by the lightcuring unit and by its light energy density. © Operative Dentistry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Authors - Magno AFF, Martins RP, Vaz LG, Martins LP Objectives - Evaluate the shear bond strength (SBS) and the adhesive remnant index (ARI) of indirect bonded lingual brackets using xenon plasma arc light, light-emitting diode (LED) and conventional quartz-tungsten-halogen light. Material and Methods - Lingual brackets were bonded indirectly to 60 premolars divided to three groups according to the curing light used: Group 1, plasma arc for 6 s; Group 2, LED for 10 s; and Group 3, halogen light for 40 s. After bonding, the specimens were subjected to a shear force until debonding. The debonding pattern was assessed and classified according to the ARI scores. The mean shear bond strengths were accessed by anova followed by the Student-Newman-Keuls test for multiple comparisons. ARI scores were assessed using the chi-square test. Results - The three groups showed significant differences (p < 0.001), with the averages of group 1 < group 2 < group 3. Groups showed no differences regarding ARI scores. Conclusion - Bonding lingual brackets indirectly with plasma arc, during 60% of the time used for the LED, produced lower SBS than obtained with the latter. Using LED during 25% of the time of the halogen light produced lower SBS than obtained with the latter. These differences did not influence the debonding pattern and are clinically acceptable according to the literature. © 2010 John Wiley & Sons A/S.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: This study evaluated the temperature rise of the adhesive system Single Bond (SB) and the composite resins Filtek Z350 flow (Z) and Filtek Supreme (S), when polymerized by light-emitting diode (LED XL 3000) and quartz-tungsten halogen (QTH Biolux). METHODS: Class V cavities (3 yen2 mm) were prepared in 80 bovine incisors under standardized conditions. The patients were divided as follows: G1: Control; G2: SB; G3: SB + Z; G4: SB + S. The groups were subdivided into two groups for polymerization (A: QTH, B: LED). Light curing was performed for 40 s and measurement of temperature changes during polymerization was performed with a thermocouple positioned inside the pulp chamber. Data were statistically analyzed using ANOVA and Tukey tests. RESULTS: The factors material (P<0.00001) and curing unit (P<0.00001) had significant influence on temperature rise. The lowest temperature increase (0.15 degrees C) was recorded in G2 B and the highest was induced in G1 A (0.75 degrees C, P<0.05). In all groups, lower pulp chamber temperature measurements were obtained when using LED compared to QTH (P<0.05). CONCLUSION: QTH caused greater increases in tooth temperature than LED. However, both sources did not increase pulpal temperature above the critical value that may cause pulpal damage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effects of occlusal splint on the electric activity of masseter were studied in 15 women who presented sleep bruxism using surface electromyography. Sleep bruxism was defined by its clinical characteristics. The signal acquisition was done during mandible occlusion without clenching and maximum voluntary contraction in two situations. The first was after a workday without using the occlusal splint; and the second, after a sleeping night using occlusal splints. Evaluating masseter muscles during mandible occlusion without clenching, it could be observed that lower values were noticed after splint wearing in both sides. The same results were verified in maximum voluntary contraction (MVC). These results confirmed that the use of occlusal splints reduced the electromyographic activity of the right and left masseters, showing its myorelaxing effect. © 2009 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this paper was to evaluate the antimicrobial activity of 2% chlorhexidine gel (CLX) associated with various intracanal medicaments against Candida albicans and Enterococcus faecalis inoculated in root canals. Thirty six human single-rooted teeth were contaminated with C.albicans and E.faecalis. The canals were instrumented using 2% CLX gel and were divided into three groups according to the intracanal medicaments (ICM) used. Group 1: calcium hydroxide paste [Ca(OH)], Group 2: 2% chlorhexidine gel (CLX) and Group 3: 2% CLX gel + Ca(OH). The root canal collections were performed after 21 days of contamination (control collection), after instrumentation (1st collection), after 14 days of intracanal medicament (2nd collection) and 7 days after medicament removal (3rd collection). The microbiological samples were plated in culture media and incubated for 48 hours. The results were submitted to Kruskal-Wallis test (P ≤ 0.05). It was verified that the instrumentation with CLX reduced the number of CFU/ml significantly when compared with the confirmation collection (control). However, the use of the ICM was only capable to eliminate completely the microorganisms in the root canals without difference statistics between them. Although the use of 2% chlorherixidine gel reduces the number of microorganisms significantly, only the ICM calcium hydroxide and calcium hydroxide associated with chlorhexidine are able to eliminate these microorganisms completely.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the Knoop hardness and polymerization depth of a dual-cured resin cement, light-activated at different distances through different thicknesses of composite resin. One bovine incisor was embedded in resin and its buccal surface was flattened. Dentin was covered with PVC film where a mold (0.8-mm-thick and 5 mm diameter) was filled with cement and covered with another PVC film. Light curing (40 s) was carried out through resin discs (2, 3, 4 or 5 mm) with a halogen light positioned 0, 1, 2 or 3 mm from the resin surface. After storage, specimens were sectioned for hardness measurements (top, center, and bottom). Data were subjected to split-plot ANOVA and Tukey's test (α=0.05). The increase in resin disc thickness decreased cement hardness. The increase in the distance of the light curing tip decreased hardness at the top region. Specimens showed the lowest hardness values at the bottom, and the highest at the center. Resin cement hardness was influenced by the thickness of the indirect restoration and by the distance between the light-curing unit tip and the resin cement surface.