Resumo:
A mathematical model for the group combustion of pulverized coal particles was developed in a previous work. It includes the Lagrangian description of the dehumidification, devolatilization and char gasification reactions of the coal particles in the homogenized gaseous environment resulting from the three fuels, CO, H2 and volatiles, supplied by the gasification of the particles and their simultaneous group combustion by the gas phase oxidation reactions, which are considered to be very fast. This model is complemented here with an analysis of the particle dynamics, determined principally by the effects of aerodynamic drag and gravity, and its dispersion based on a stochastic model. It is also extended to include two other simpler models for the gasification of the particles: the first one for particles small enough to extinguish the surrounding diffusion flames, and a second one for particles with small ash content when the porous shell of ashes remaining after gasification of the char, non structurally stable, is disrupted. As an example of the applicability of the models, they are used in the numerical simulation of an experiment of a non-swirling pulverized coal jet with a nearly stagnant air at ambient temperature, with an initial region of interaction with a small annular methane flame. Computational algorithms for solving the different stages undergone by a coal particle during its combustion are proposed. For the partial differential equations modeling the gas phase, a second order finite element method combined with a semi-Lagrangian characteristics method are used. The results obtained with the three versions of the model are compared among them and show how the first of the simpler models fits better the experimental results.
Resumo:
Thermally driven liquid-desiccant air-conditioners (LDAC) are a proven but still developing technology. LDACs can use a solar thermal system to reduce the operational cost and environmental impact of the system by reducing the amount of fuel (e.g. natural gas, propane, etc.) used to drive the system. LDACs also have a key benefit of being able to store energy in the form of concentrated desiccant storage. TRNSYS simulations were used to evaluate several different methods of improving the thermal and electrical coefficients of performance (COPt and COPe) and the solar fraction (SF) of a LDAC. The study analyzed a typical June to August cooling season in Toronto, Ontario. Utilizing properly sized, high-efficiency pumps increased the COPe to 3.67, an improvement of 55%. A new design, featuring a heat recovery ventilator on the scavenging-airstream and an energy recovery ventilator on the process-airstream, increased the COPt to 0.58, an improvement of 32%. This also improved the SF slightly to 54%, an increase of 8%. A new TRNSYS TYPE was created to model a stratified desiccant storage tank. Different volumes of desiccant were tested with a range of solar array system sizes. The largest storage tank coupled with the largest solar thermal array showed improvements of 64% in SF, increasing the value to 82%. The COPe was also improved by 17% and the COPt by 9%. When combining the heat recovery systems and the desiccant storage systems, the simulation results showed a 78% increase in COPe and 30% increase in COPt. A 77% improvement in SF and a 17% increase in total cooling rate were also predicted by the simulation. The total thermal energy consumed was 10% lower and the electrical consumption was 34% lower. The amount of non-renewable energy needed from the natural gas boiler was 77% lower. Comparisons were also made between LDACs and vapour-compression (VC) systems. Dependent on set-up, LDACs provided higher latent cooling rates and reduced electrical power consumption. Negatively, a thermal input was required for the LDAC systems but not for the VC systems.
Resumo:
Thermally driven liquid-desiccant air-conditioners (LDAC) are a proven but still developing technology. LDACs can use a solar thermal system to reduce the operational cost and environmental impact of the system by reducing the amount of fuel (e.g. natural gas, propane, etc.) used to drive the system. LDACs also have a key benefit of being able to store energy in the form of concentrated desiccant storage. TRNSYS simulations were used to evaluate several different methods of improving the thermal and electrical coefficients of performance (COPt and COPe) and the solar fraction (SF) of a LDAC. The study analyzed a typical June to August cooling season in Toronto, Ontario. Utilizing properly sized, high-efficiency pumps increased the COPe to 3.67, an improvement of 55%. A new design, featuring a heat recovery ventilator on the scavenging-airstream and an energy recovery ventilator on the process-airstream, increased the COPt to 0.58, an improvement of 32%. This also improved the SF slightly to 54%, an increase of 8%. A new TRNSYS TYPE was created to model a stratified desiccant storage tank. Different volumes of desiccant were tested with a range of solar array system sizes. The largest storage tank coupled with the largest solar thermal array showed improvements of 64% in SF, increasing the value to 82%. The COPe was also improved by 17% and the COPt by 9%. When combining the heat recovery systems and the desiccant storage systems, the simulation results showed a 78% increase in COPe and 30% increase in COPt. A 77% improvement in SF and a 17% increase in total cooling rate were also predicted by the simulation. The total thermal energy consumed was 10% lower and the electrical consumption was 34% lower. The amount of non-renewable energy needed from the natural gas boiler was 77% lower. Comparisons were also made between LDACs and vapour-compression (VC) systems. Dependent on set-up, LDACs provided higher latent cooling rates and reduced electrical power consumption. Negatively, a thermal input was required for the LDAC systems but not for the VC systems.
Resumo:
Greenhouses have become an invaluable source of year-round food production. Further development of viable and efficient high performance greenhouses is important for future food security. Closing the greenhouse envelope from the environment can provide benefits in space heating energy savings, pest control, and CO2 enrichment. This requires the application of a novel air conditioning system to handle the high cooling loads experienced by a greenhouse. Liquid desiccant air-conditioning (LDAC) have been found to provide high latent cooling capacities, which is perfect for the application of a humid greenhouse microclimate. TRNSYS simulations were undertaken to study the feasibility of two liquid desiccant dehumidification systems based on their capacity to control the greenhouse microclimate, and their cooling performance. The base model (B-LDAC) included a natural gas boiler, and two cooling systems for seasonal operation. The second model (HP-LDAC) was a hybrid liquid desiccant-heat pump dehumidification system. The average tCOPdehum and tCOPtotal of the B-LDAC system increased from 0.40 and 0.56 in January to 0.94 and 1.09 in June. Increased load and performance during a sample summer day improved these values to 3.5 and 3.0, respectively. The average eCOPdehum and eCOPtotal values were 1.0 and 1.8 in winter, and 1.7 and 2.1 in summer. The HP-LDAC system produced similar daily performance trends where the annual average eCOPdehum and eCOPtotal values were 1.3 and 1.2, but the sample day saw peaks of 2.4 and 3.2, respectively. The B-LDAC and HP-LDAC results predicted greenhouse temperatures exceeding 30°C for 34% and 17% of the month of July, respectively. Similarly, humidity levels increased in summer months, with a maximum of 14% of the time spent over 80% in May for both models. The percentage of annual savings in space heating energy associated with closing the greenhouse to ventilation was 34%. The additional annual regeneration energy input was reduced by 26% to 526 kWhm-2, with the implementation of a heat recovery ventilator on the regeneration exhaust air. The models also predicted an electrical energy input of 245 kWhm-2 and 305 kWhm-2 for the B-LDAC and HP-LDAC simulations, respectively.
Resumo:
Kenia liegt in den Äquatorialtropen von Ostafrika und ist als ein weltweiter Hot-Spot für Aflatoxinbelastung insbesondere bei Mais bekannt. Diese toxischen und karzinogenen Verbindungen sind Stoffwechselprodukte von Pilzen und so insbesondere von der Wasseraktivität abhängig. Diese beeinflusst sowohl die Trocknung als auch die Lagerfähigkeit von Nahrungsmitteln und ist somit ein wichtiger Faktor bei der Entwicklung von energieeffizienten und qualitätsorientierten Verarbeitungsprozessen. Die vorliegende Arbeit hat sich zum Ziel gesetzt, die Veränderung der Wasseraktivität während der konvektiven Trocknung von Mais zu untersuchen. Mittels einer Optimierungssoftware (MS Excel Solver) wurde basierend auf sensorerfassten thermo-hygrometrischen Daten der gravimetrische Feuchteverlust von Maiskolben bei 37°C, 43°C und 53°C vorausberechnet. Dieser Bereich stellt den Übergang zwischen Niedrig- und Hochtemperaturtrocknung dar. Die Ergebnisse zeigen deutliche Unterschiede im Verhalten der Körner und der Spindel. Die Trocknung im Bereich von 35°C bis 45°C kombiniert mit hohen Strömungsgeschwindigkeiten (> 1,5 m / s) begünstigte die Trocknung der Körner gegenüber der Spindel und kann daher für eine energieeffiziente Trocknung von Kolben mit hohem Anfangsfeuchtegehalt empfohlen werden. Weitere Untersuchungen wurden zum Verhalten unterschiedlicher Schüttungen bei der bei Mais üblichen Satztrocknung durchgeführt. Entlieschter und gedroschener Mais führte zu einem vergrößerten Luftwiderstand in der Schüttung und sowohl zu einem höheren Energiebedarf als auch zu ungleichmäßigerer Trocknung, was nur durch einen erhöhten technischen Aufwand etwa durch Mischeinrichtungen oder Luftumkehr behoben werden könnte. Aufgrund des geringeren Aufwandes für die Belüftung und die Kontrolle kann für kleine landwirtschaftliche Praxisbetriebe in Kenia daher insbesondere die Trocknung ganzer Kolben in ungestörten Schüttungen empfohlen werden. Weiterhin wurde in der Arbeit die Entfeuchtung mittels eines Trockenmittels (Silikagel) kombiniert mit einer Heizquelle und abgegrenztem Luftvolumen untersucht und der konventionellen Trocknung gegenüber gestellt. Die Ergebnisse zeigten vergleichbare Entfeuchtungsraten während der ersten 5 Stunden der Trocknung. Der jeweilige Luftzustand bei Verwendung von Silikagel wurde insbesondere durch das eingeschlossene Luftvolumen und die Temperatur beeinflusst. Granulierte Trockenmittel sind bei der Maistrocknung unter hygienischen Gesichtspunkten vorteilhaft und können beispielsweise mit einfachen Öfen regeneriert werden, so dass Qualitätsbeeinträchtigungen wie bei Hochtemperatur- oder auch Freilufttrocknung vermieden werden können. Eine hochwertige Maistrocknungstechnik ist sehr kapitalintensiv. Aus der vorliegenden Arbeit kann aber abgeleitet werden, dass einfache Verbesserungen wie eine sensorgestützte Belüftung von Satztrocknern, der Einsatz von Trockenmitteln und eine angepasste Schüttungshöhe praktikable Lösungen für Kleinbauern in Kenia sein können. Hierzu besteht, ggf. auch zum Aspekt der Verwendung regenerativer Energien, weiterer Forschungsbedarf.