618 resultados para DURATIONS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Several studies have proven the efficacy of pulsed dye laser (PDL) in the treatment of plaque type psoriasis. However, only two published studies indicate the effectiveness of PDL on nail psoriasis.
Resumo:
OBJECTIVE: In young, first-episode, never-treated schizophrenics compared with controls, (a) generally shorter durations of EEG microstates were reported (Koukkou et al., Brain Topogr 6 (1994) 251; Kinoshita et al., Psychiatry Res Neuroimaging 83 (1998) 58), and (b) specifically, shorter duration of a particular class of microstates (Koenig et al., Eur Arch Psychiatry Clin Neurosci 249 (1999) 205). We now examined whether older, chronic schizophrenic patients with positive symptomatology also show these characteristics. METHODS: Multichannel resting EEG (62.2 s/subject) from two subject groups, 14 patients (36.1+/-10.2 years old) and 13 controls (35.1+/-8.2 years old), all males, was analyzed into microstates using a global approach for microstate analysis that clustered the microstates into 4 classes (Koenig et al., 1999). RESULTS: (a) Hypothesis testing of general microstate shortening supported a trend (P=0.064). (b) Two-way repeated measure ANOVA (two subject groupsx4 microstate classes) showed a significant group effect for microstate duration. Posthoc tests revealed that a microstate class with brain electric field orientation from left central to right central-posterior had significantly shorter microstates in patients than controls (68.5 vs. 76.1 ms, P=0.034). CONCLUSIONS: The results were in line with the results from young, never-treated, productive patients, thus suggesting that in schizophrenic information processing, one class of mental operations might intermittently cause deviant mental constructs because of premature termination of processing.
Resumo:
Using a weighted up-down procedure, in each of eight conditions 28 participants compared durations of auditory (noise bursts) or visual (LED flashes) intervals; filled or unfilled with 3-ms markers; with or without feedback. Standards (Sts) were 100 and 1000 ms, and the ISI 900 ms. Intermixedly, presentation orders were St-Comparison (Co) and Co-St. TOEs were positive for St=100-ms and negative for St=1000 ms. Weber fractions (WFs, JND/St) were lowered by feedback. For visual-filled and visual-empty, WFs were highest for St=100 ms. For auditory-filled and visual-empty, St interacted with Order: lowest WFs occurred for St-Co with St=1000 ms, but for Co-St with St=100 ms. Lowest average WFs occurred with St-Co for visual-filled, but with Co-St for visual-empty. The results refute the generalization of better discrimination with St-Co than with Co-St (”type-B effect”), and support the notion of sensation weighting: flexibly differential impact weights of the compared durations in generating the response.
Resumo:
The purpose of this study was to assess the accuracy and precision of airborne volatile organic compound (VOC) concentrations measured using passive air samplers (3M 3500 organic vapor monitors) over extended sampling durations (9 and 15 days). A total of forty-five organic vapor monitor samples were collected at a State of Texas air monitoring site during two different sampling periods (July/August and November 2008). The results of this study indicate that for most of the tested compounds, there was no significant difference between long-term (9 or 15 days) sample concentrations and the means of parallel consecutive short-term (3 days) sample concentrations. Biases of 9 or 15-day measurements vs. consecutive 3-day measurements showed considerable variability. Those compounds that had percent bias values of <10% are suggested as acceptable for long-term sampling (9 and 15 days). Of the twenty-one compounds examined, 10 compounds are classified as acceptable for long-term sampling; these include m,p-xylene, 1,2,4-trimethylbenzene, n-hexane, ethylbenzene, benzene, toluene, o-xylene, d-limonene, dimethylpentane and methyl tertbutyl ether. The ratio of sampling procedure variability relative to variability within days was approximately 1.89 for both sampling periods for the 3-day vs. 9-day comparisons and approximately 2.19 for both sampling periods for the 3-day vs. 15-day comparisons. Considerably higher concentrations of most VOCs were measured during the November sampling period compared to the July/August period. These differences may be a result of varying meteorological conditions during these two time periods, e.g., the differences in wind direction, and wind speed. Further studies are suggested to further evaluate the accuracy and precision of 3M 3500 organic vapor monitors over extended sampling durations. ^
Resumo:
ABSTRACT: The comparison of the different bids in the tender for a project, with the traditional contract system based on unit rates open to and re-measurement, requires analysis tools that are able to discriminate proposals having a similar overall economic impact, but that might show a very different behaviour during the execution of the works. RESUMEN: La estimación rápida de costes en fases iniciales del proyecto por métodos paramétricos y referencias estadísticas es un tema bien estudiado, divulgado y aplicado en el sector de la construcción. Sin embargo, existe poca literatura técnica sobre sistemas de predimensionado de tiempos, que permitan realizar rápidamente una planificación con un grado de aproximación razonable. Este texto reúne dos aspectos ya conocidos, pero hasta ahora independientes, y una aportación propia: -La estimación del plazo final por referencias estadísticas (BCIS, 2000) - La estimación del reparto del coste total a lo largo de la ejecución mediante curvas "S" (diversos autores) La estimación de la duración de la ejecución de las actividades en función de su coste. El conjunto de estas tres técnicas, aplicadas a un proyecto, permite obtener una planificación con el suficiente grado de detalle y fiabilidad para tomar decisiones en fases iniciales del proyecto.
Resumo:
By most accounts the psychological stressor restraint produces a distinct pattern of neuronal activation in the brain. However, some evidence is incongruous with this pattern, leading us to propose that the restraint- induced pattern in the central nervous system might depend on the duration of restraint used. We therefore determined the pattern of neuronal activation ( as indicated by the presence of Fos protein) seen in the paraventricular nucleus (PVN), bed nucleus of the stria terminalis, amygdala, locus coeruleus, nucleus tractus solitarius (NTS), ventrolateral medulla (VLM) and thoracic spinal cord of the rat in response to 0, 15, 30 or 60 min periods of restraint. We found that although a number of cell groups displayed a linear increase in activity with increasing durations of restraint ( e. g. hypothalamic corticotrophin-releasing factor (CRF) cells, medial amygdala neurons and sympathetic preganglionic neurons of the thoracic spinal cord), a number of cell groups did not. For example, in the central amygdala restraint produced both a decrease in CRF cell activity and an increase in non-CRF cell activity. In the locus coeruleus, noradrenergic neurons did not display Fos in response to 15 min of restraint, but were significantly activated by 30 or 60 min restraint. After 30 or 60 min restraint a greater degree of activation of more rostral A1 noradrenergic neurons was observed compared with the pattern of A1 noradrenergic neurons in response to 15 min restraint. The results of this study demonstrate that restraint stress duration determines the amount and the pattern of neuronal activation seen in response to this psychological stressor.
Resumo:
Previous investigations employing electropalatography (EPG) have identified articulatory timing deficits in individuals with acquired dysarthria. However, this technology is yet to be applied to the articulatory timing disturbance present in Parkinson's disease (PD). As a result, the current investigation aimed to use EPG to comprehensively examine the temporal aspects of articulation in a group of nine individuals with PD at sentence, word and segment level. This investigation followed on from a prior study (McAuliffe, Ward and Murdoch) and similarly, aimed to compare the results of the participants with PD to a group of aged (n=7) and young controls (n=8) to determine if ageing contributed to any articulatory timing deficits observed. Participants were required to read aloud the phrase I saw a ___ today'' with the EPG palate in-situ. Target words included the consonants /1/, /s/ and /t/ in initial position in both the /i/ and /a/ vowel environments. Perceptual investigation of speech rate was conducted in addition to objective measurement of sentence, word and segment duration. Segment durations included the total segment length and duration of the approach, closure/constriction and release phases of EPG consonant production. Results of the present study revealed impaired speech rate, perceptually, in the group with PD. However, this was not confirmed objectively. Electropalatographic investigation of segment durations indicated that, in general, the group with PD demonstrated segment durations consistent with the control groups. Only one significant difference was noted, with the group with PD exhibiting significantly increased duration of the release phase for /1a/ when compared to both the control groups. It is, therefore, possible that EPG failed to detect lingual movement impairment as it does not measure the complete tongue movement towards and away from the hard palate. Furthermore, the contribution of individual variation to the present findings should not be overlooked.
Resumo:
Purpose: To determine the response of retinal vessels to differing durations of flicker light (FL) sitmulation. Methods: We recorded retinal arterial and venous vessel dilation to 12.5 Hz flicker light provocation (Retinal Vessel Analyzer, Imedos Systems) of varying duration (5, 7, 10 and 20 seconds) in twelve healthy young individuals (age range 26-45 yrs). All participants underwent a full ocular examination including intraocular pressure and blood pressure measurements. Results: Maximum dilation (MD) did not show a significant dependence on flicker duration in arteries whereas maximum constriction (MC) did. However, in veins MD significantly increased with flicker duration. Approximately 80-90% of MD in arteries is reached within 10 seconds of flicker light stimulation. Conclusions: The vast majority of arterial dilatory capacity is reached within 10 seconds of flicker light stimulation even though venous dilation continues strongly. Since the MC of arteries shows a significant dependence on flicker duration measurements at two different durations can provide more information about the retinal vascular system than at a single flicker duration alone.