999 resultados para DIODE LASER
Resumo:
This study evaluated the effect of 980-nm diode laser at different parameters on root canal dentin permeability associated with different irrigants. Seventy-five canines were sectioned at 15 mm from the apex, prepared mechanically up to #40 .02 instrument, and irrigated with 2 mL distilled water. Final irrigation (10 mL) was used as follows: (1) distilled water; (2) 1% NaOCl; (3) 17% ethylenediaminetetraacetic acid + a cationic surfactant cetyltrimethylammonium bromide (EDTAC). Laser was applied at 1.5 or 3.0 W as either continuous wave or pulsed wave (100 Hz). The teeth were then processed histochemically, the percentage of copper ion penetration into the dentin of the canal walls was counted, and the data were analyzed statistically with the Tukey-Kramer test (alpha < .01). When laser was associated with water, an increase in permeability was found, whereas permeability decreased when associated with EDTAC. Dentin permeability after laser irradiation was directly dependent on the solution used for final irrigation.
Resumo:
BACKGROUND and OBJECTIVE: A non-touch laser-induced microdrilling procedure is studied on mouse zona pellucida (ZP). STUDY DESIGN/MATERIALS and METHODS: A 1.48-microns diode laser beam is focused in a 8-microns spot through a 45x objective of an inverted microscope. Mouse zygotes, suspended in a culture medium, are microdrilled by exposing their ZP to a short laser irradiation and allowed to develop in vitro. RESULTS: Various sharp-edged holes can be generated in the ZP with a single laser irradiation. Sizes can be varied by changing irradiation time (3-100 ms) or laser power (22-55 mW). Drilled zygotes present no signs of thermal damage under light and scanning electron microscopy and develop as expected in vitro, except for a distinct eight-shaped hatching behavior. CONCLUSION: The microdrilling procedure can generate standardized holes in mouse ZP, without any visible side effects. The hole formation can be explained by a local photothermolysis of the protein matrix.
Resumo:
The present work is mainly concentrated on setting up a NIR tunable diode laser absorption (TDLA) spectrometer for high-resolution molecular spectroscopic studies. For successfully recording the high-resolution tunable diode laser spectrum, various experimental considerations are to be taken into account like the setup should be free from mechanical vibrations, sample should be kept at a low pressure, laser should be in a single mode operation etc. The present experimental set up considers all these factors. It is to be mentioned here that the setting up of a high resolution NIR TDLA spectrometer is a novel experiment requiring much effort and patience. The analysis of near infrared (NIR) vibrational overtone spectra of some substituted benzene compounds using local mode model forms another part of the present work. An attempt is made to record the pulsed laser induced fluorescence/Raman spectra of some organic compounds. A Q-switched Nd:YAG laser is used as the excitation source. A TRIAX monochromator and CCD detector is used for the spectral recording. The observed fluorescence emission for carbon disulphide is centered at 680 nm; this is assigned as due to the n, p* transition. Aniline also shows a broad fluorescence emission centered at 725 nm, which is due to the p,p* transition. The pulsed laser Raman spectra of some organic compounds are also recorded using the same experimental setup. The calibration of the set up is done using the laser Raman spectra of carbon tetrachloride and carbon disulphide. The observed laser Raman spectra for aniline, o-chloroaniline and m-chlorotoluene show peaks characteristics of the aromatic ring in common and the characteristics peaks due to the substitutuent groups. Some new peaks corresponding to low-lying vibrations of these molecules are also assigned
Resumo:
Objective. The objective of this study was to evaluate the disinfection degree of dentine caused by the use of diode laser after biomechanical procedures. Study design. Thirty teeth were sectioned and roots were autoclaved and incubated for 4 weeks with a suspension of Enterococcus faecalis. The specimens were randomly divided into 3 groups (n = 10): G1, instrumented with rotary files, irrigated with 0.5% sodium hypochlorite and 17% EDTA-T, and then irradiated by 830-nm diode laser at 3 W; G2, the same procedures as G1 but without laser irradiation; and G3, irrigation with saline solution (control). Dentin samples of each third were collected with carbide burs and aliquots were sowed to count viable cells. Results. The disinfection degree achieved was 100% in G1 and 98.39% in G2, when compared to the control group (G3). Conclusion. Diode laser irradiation provided increased disinfection of the deep radicular dentin in the parameters and samples tested.
Resumo:
The high intensity diode laser has been studied in periodontics for the reduction of subgingival bacteria in non-surgical treatment. Our study evaluated the bacterial effect as well as changes in periodontal clinical parameters promoted by root scaling and planing associated with this wavelength. Twenty-seven patients randomly assigned in two groups underwent root scaling and planing on the tested sites, and only the experimental group received the diode laser irradiation. Among the clinical parameters studied, the clinical probing depth (CPD) and the clinical attachment level (CAL) resulted in significant enhancement in the control group when compared with the experimental group (P = 0.014 and P = 0.039, respectively). The results were similar for both groups regarding the plaque index (PI) and bleeding on probing (BP). No significant difference in the microbiological parameters was observed between the control and experimental groups. It was possible to conclude that the high power diode laser adjunct to the non-surgical periodontal treatment did not promote additional effects to the conventional periodontal treatment.
Resumo:
The aim of this in vivo study was to evaluate the thermal effects caused by 810 nm 1.2 W diode laser irradiation of periodontal tissues. Despite all data available concerning the laser application for periodontal treatment, one of the most relevant challenges is to prevent the harmful tissue heating induced by different clinical protocols. Periodontal pockets were induced at molars in 96 rats. Several irradiation powers under CW mode were investigated: 0, 400, 600, 800, 1000, 1200 mW. The pockets were irradiated using a 300 A mu m frontal illumination fiber. The animals were killed at 4 or 10 days after irradiation. The mandible was surgically removed and histologically processed. The histological sections stained with H/E demonstrated that irradiation parameters up to 1000 mW were thermally safe for the periodontal tissues. The sections stained with Brown & Brenn technique evidenced bacteria in the periodontal tissues. Consequently, the diode laser irradiation as a unique treatment was not capable to eliminate bacteria of the biofilm present in the pockets. According to the methodology used here, it was concluded that the thermal variation promoted by a diode laser can cause damage to periodontal tissues depending on the energy density used. The 1.2 W diode laser irradiation itself does not control the bacteria present in the biofilm of the periodontal pockets without mechanical action. The knowledge of proper high intensity laser parameters and methods of irradiation for periodontal protocols may prevent any undesirable thermal damage to the tissues.
Resumo:
Photodynamic therapy (PDT) is based on the association of a light source and tight sensitive agents in order to cause the selective death of tumor cells. To evaluate topical 5-aminolaevulinic acid (5-ALA) and diode laser photodynamic single session therapy single session for non-melanoma skin cancer (NMSC), a long-term follow-up was performed. Nineteen Bowen`s disease (BD) and 15 basal cell. carcinoma (BCC) lesions were submitted to 6-h topical and occlusive 20% 5-ALA plus DMSO and EDTA, and later were exposed to 630 nm diode laser, 100 or 300 J cm(-2) dose. At 3 months tumor-free rate was 91.2% (31/34) whereas at 60 months, 57.7% (15/26), slightly higher in BCC (63.6%; 7/11). The relation between the reduction of the clinical response and the increase of tumor dimension observed at 18 months was lost at 60 months. The sBCC recurrence was earlier compared to the nBCC one. ALA-PDT offered important advantages: it is minimally invasive, an option for patients under risk of surgical complications; clinical feasibility; treatment of multiple lesions in only one session or lesions in poor heating sites and superior esthetical results. However, the recurrence rate increase after ALA-PDT diode laser single session can be observed at tong-term follow-up, and the repetitive sessions, an additional. advantage of the method, is strongly recommended. The clinical response and recurrence time seem to be related to the laser light dose and NMSC types/sub-types, thickness and dimension, which must be considered for the choice of the ALA-PDT. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A free-running, temperature stabilized diode laser has been injection-locked to an external cavity diode laser for use in cold Rydberg atom experiments. Cold rubidium atoms in a magneto-optical trap (MOT) are excited to Rydberg states using a 10 ns laser pulse. The Rydberg atoms spontaneously ionize due to dipole forces, and the collisional ionization dynamics are observed as a function of atom density and principal quantum number of the Rydberg state, n. The injection-locked diode laser will be used as a repumper in conjunction with a dark spontaneous-force optical trap (SPOT) to increase the Rydberg state density. We report on the design of the injection-locked laser system.
Resumo:
Purpose: the objective of this study was to determine if the zona thinning (ZT) technique improved the rates of implantation and clinical pregnancy for patients aged, greater than or equal to38 years submitted to an ICSI program.Methods: A total of 100 patients submitted to ICSI and aged, greater than or equal to38 years were divided in a prospective and randomized manner into two groups: Group I - patients submitted to ZT (n = 50); a laser diode with 1.48 mum wavelength (Fertilaser) was used for the ZT procedure with 1-2 irradiations of 10 ms applied to four different positions on the zona pellucida (ZP) of each embryo to thin 60-90% of the ZP (each point with a 15-20 mum length of ZT). Group II - patients with no ZT (n = 50). In both groups, embryo transfer was performed on the second or third day.Results: the age of Group I patients (39.8 +/- 1.3) did not differ (p = 0.67) from that of Group II patients (40 +/- 1.9). The number of oocytes retrieved at metaphase II from Group I (6.4 +/- 4.2) and Group II (6.8 +/- 5) was similar (p = 0.94). Normal fertilization rates and cleavage rates were similar (p = 0.78 and p = 0.63, respectively) for Group I (71.5 +/- 22% and 96.7 +/- 11%) and Group II (73.5 +/- 19.7% and 96 +/- 11%, respectively). The number of embryos transferred was similar (p = 0.53) for the two groups (Group I = 3.1 +/- 1.3; Group II = 2.9 +/- 1.1). The thickness of the ZP of Group I embryos (16.9 +/- 2.4 mum) did not differ (p = 0.97) from that of Group II embryos (16.9 +/- 2.3 mum). The rates of embryo implantation and clinical pregnancy per embryo transfer were similar (p = 0.67, p = 0.61) for Group I (7 and 16%, respectively) and for Group II (8.2 and 22%, respectively).Conclusions: These results suggest that ZT in the population aged, 38 years may have no impact on ICSI success rates. However, this conclusion is limited to a situation in which length of the laser ZT was less than or equal to 20 mum and the laser was applied to four different positions.
Resumo:
Background: the aim of the present study was to compare the effects of Er:YAG and diode laser treatments of the root surface on intrapulpal temperature after scaling and root planing with hand instruments.Methods: Fifteen extracted single-rooted teeth were scaled and root planed with hand instruments. The teeth were divided into 3 groups of 5 each and irradiated on their buccal and lingual surfaces: group A: Er:YAG laser, 2.94 mum/100 mJ/10 Hz/ 30 seconds; group B: diode laser, 810 nm/1.0 W/0.05 ms/30 seconds; group C: diode laser, 810 nm/1.4 W/0.05 ms/30 seconds. The temperature was monitored by means of a type T thermocouple (copper-constantan) positioned in the pulp chamber to assess pulpal temperature during and before irradiation. Afterwards, the specimens were longitudinally sectioned, and the buccal and lingual surfaces of each root were analyzed by scanning electron microscopy.Results: In the Er:YAG laser group, the thermal analysis revealed an average temperature of -2.2 +/- 1.5degreesC, while in the diode laser groups, temperatures were 1.6 +/- 0.8degreesC at 1.0 W and 3.3 +/- 1.0degreesC at 1.4 W. Electronic micrographs revealed that there were no significant morphological changes, such as charring, melting, or fusion, in any group, although the specimens were found to be more irregular in the Er:YAG laser group.Conclusions: the application of Er:YAG and diode lasers at the utilized parameters did not induce high pulpal temperatures. Root surface irregularities were more pronounced after irradiation with an Er:YAG laser than with a diode laser.
Resumo:
The aim of this in vivo study was to evaluate the thermal effects caused by 810 nm 1.2 W diode laser irradiation of periodontal tissues. Despite all data available concerning the laser application for periodontal treatment, one of the most relevant challenges is to prevent the harmful tissue heating induced by different clinical protocols. Periodontal pockets were induced at molars in 96 rats. Several irradiation powers under CW mode were investigated: 0, 400, 600, 800, 1000, 1200 mW. The pockets were irradiated using a 300 A mu m frontal illumination fiber. The animals were killed at 4 or 10 days after irradiation. The mandible was surgically removed and histologically processed. The histological sections stained with H/E demonstrated that irradiation parameters up to 1000 mW were thermally safe for the periodontal tissues. The sections stained with Brown & Brenn technique evidenced bacteria in the periodontal tissues. Consequently, the diode laser irradiation as a unique treatment was not capable to eliminate bacteria of the biofilm present in the pockets. According to the methodology used here, it was concluded that the thermal variation promoted by a diode laser can cause damage to periodontal tissues depending on the energy density used. The 1.2 W diode laser irradiation itself does not control the bacteria present in the biofilm of the periodontal pockets without mechanical action. The knowledge of proper high intensity laser parameters and methods of irradiation for periodontal protocols may prevent any undesirable thermal damage to the tissues.
Resumo:
Dentin hipersensitivity (DH) is a relatively common clinical condition, especially in periodontal patients after treatment. In this study it was evaluated 28 teeth who presented dentin hypersensitivity. The teeth were subjected to clinical and radiographic exams and were divided into groups following the treatment and the time of examination after application proposed: GI: PO 3% (Potassium Oxalate-group control)/Baseline; GII: PO 3%/3 days after first session; GIII: PO 3%/6 days; GIV: PO 3%/30 days; GV: PO 3%/60 days; GVI: PO 3%/90 days; GVII: Laser (Low-level diode laser with 110 mW/cm(2))/Baseline; GVIII: Laser/7 days after first session; GIX: Laser/14 days; GX: Laser/30 days; GXI: Laser/60 days; and GXII: Laser/90 days. The groups I-VI, the teeth were subjected to 3 applications (GI-GIII) of desensitizing agent at regular intervals of seven days. The Groups VII-XI, each tooth was subjected to three applications (GVII GIX) in three different points (mesial, meddle and distal surfaces) with an interval of 72 h. The time of application in each point was of 33 s and the patients from both groups were followed up to 90 days. The nonparametric test Friedman (alpha = 0.05) was applied and the test of Mann Whitney (alpha = 0.05) was used to compare the time of examination between groups. The application of Laser was effective 6 days after first session and to PO was 30 days. It was observed that both treatments were effective for the reduction of dentin hypersensitivity, however the laser presented better effectiveness.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. To evaluate the effectiveness of the color change of hybrid light-emitting diode (LED) and low-intensity infrared diode laser devices for activating dental bleaching and to verify the occurrence of a color regression with time. Material and methods. A total of 180 specimens obtained from human premolars were immersed in a coffee solution for 15 days for darkening and then divided into eight experimental groups (n = 20 in each) as follows: G1, bleaching without light; G2, bleaching with halogen light; G3, bleaching with a blue LED (1000 mW/470 nm) and a laser device (120 mW/795 nm) simultaneously; G4, bleaching with an LED emitting blue light (1000 mW/470 nm); G5, bleaching with a blue LED (800 mW/470 nm) and a laser device (500 mW/830 nm) simultaneously; G6, bleaching with a blue LED device (800 mW); G7, bleaching with a green LED (600 mW/530 nm) and a laser device (120 mW/795 nm) simultaneously; and G8, bleaching with a green LED (600 mW). Three measurements were performed (at baseline and 14 days and 12 months after bleaching) using a Vita Easyshade spectrophotometer. The data were submitted to two-way ANOVA and a Tukey test. Results. All groups showed significantly higher Delta E values than Group G1, with the exception of Group G8. Variations in the Delta E values at 14 days were significant when compared with those obtained at baseline and after 12 months. Conclusions. Light activation of the bleaching gel provided faster and more intense bleaching than use of the bleaching gel without light activation. Combinations of low-intensity diode lasers are ineffective as a bleaching gel activator. Color regression was observed after 12 months of storage.