974 resultados para Current reference
Resumo:
Pós-graduação em Educação - FFC
Resumo:
IMPORTANCE Some experts suggest that serum thyrotropin levels in the upper part of the current reference range should be considered abnormal, an approach that would reclassify many individuals as having mild hypothyroidism. Health hazards associated with such thyrotropin levels are poorly documented, but conflicting evidence suggests that thyrotropin levels in the upper part of the reference range may be associated with an increased risk of coronary heart disease (CHD). OBJECTIVE To assess the association between differences in thyroid function within the reference range and CHD risk. DESIGN, SETTING, AND PARTICIPANTS Individual participant data analysis of 14 cohorts with baseline examinations between July 1972 and April 2002 and with median follow-up ranging from 3.3 to 20.0 years. Participants included 55,412 individuals with serum thyrotropin levels of 0.45 to 4.49 mIU/L and no previously known thyroid or cardiovascular disease at baseline. EXPOSURES Thyroid function as expressed by serum thyrotropin levels at baseline. MAIN OUTCOMES AND MEASURES Hazard ratios (HRs) of CHD mortality and CHD events according to thyrotropin levels after adjustment for age, sex, and smoking status. RESULTS Among 55,412 individuals, 1813 people (3.3%) died of CHD during 643,183 person-years of follow-up. In 10 cohorts with information on both nonfatal and fatal CHD events, 4666 of 48,875 individuals (9.5%) experienced a first-time CHD event during 533,408 person-years of follow-up. For each 1-mIU/L higher thyrotropin level, the HR was 0.97 (95% CI, 0.90-1.04) for CHD mortality and 1.00 (95% CI, 0.97-1.03) for a first-time CHD event. Similarly, in analyses by categories of thyrotropin, the HRs of CHD mortality (0.94 [95% CI, 0.74-1.20]) and CHD events (0.97 [95% CI, 0.83-1.13]) were similar among participants with the highest (3.50-4.49 mIU/L) compared with the lowest (0.45-1.49 mIU/L) thyrotropin levels. Subgroup analyses by sex and age group yielded similar results. CONCLUSIONS AND RELEVANCE Thyrotropin levels within the reference range are not associated with risk of CHD events or CHD mortality. This finding suggests that differences in thyroid function within the population reference range do not influence the risk of CHD. Increased CHD risk does not appear to be a reason for lowering the upper thyrotropin reference limit.
Resumo:
Bidirectional DC-DC converters are widely used in different applications such as energy storage systems, Electric Vehicles (EVs), UPS, etc. In particular, future EVs require bidirectional power flow in order to integrate energy storage units into smart grids. These bidirectional power converters provide Grid to Vehicle (V2G)/ Vehicle to Grid (G2V) power flow capability for future EVs. Generally, there are two control loops used for bidirectional DC-DC converters: The inner current loop and The outer loop. The control of DAB converters used in EVs are proved to be challenging due to the wide range of operating conditions and non-linear behavior of the converter. In this thesis, the precise mathematical model of the converter is derived and non-linear control schemes are proposed for the control system of bidirectional DC-DC converters based on the derived model. The proposed inner current control technique is developed based on a novel Geometric-Sequence Control (GSC) approach. The proposed control technique offers significantly improved performance as compared to one for conventional control approaches. The proposed technique utilizes a simple control algorithm which saves on the computational resources. Therefore, it has higher reliability, which is essential in this application. Although, the proposed control technique is based on the mathematical model of the converter, its robustness against parameter uncertainties is proven. Three different control modes for charging the traction batteries in EVs are investigated in this thesis: the voltage mode control, the current mode control, and the power mode control. The outer loop control is determined by each of the three control modes. The structure of the outer control loop provides the current reference for the inner current loop. Comprehensive computer simulations have been conducted in order to evaluate the performance of the proposed control methods. In addition, the proposed control have been verified on a 3.3 kW experimental prototype. Simulation and experimental results show the superior performance of the proposed control techniques over the conventional ones.
Resumo:
Aims The objective of the 5th International Consultation on Incontinence (ICI) chapter on Adult Conservative Management was to review and summarize the new evidence on conservative management of urinary incontinence (UI) and pelvic organ prolapse (POP) in order to compile a current reference source for clinicians, health researchers, and service planners. In this paper, we present the review highlights and new evidence on female conservative management. Methods Revision and updates of the 4th ICI Report using systematic review covering years 2008–2012. Results Each section begins with a brief definition and description of the intervention followed by a summary, where possible, of both the state and level of evidence for prevention and treatment, and ends with a “grade of recommendation.” The paper concludes with areas identified as requiring further research. Conclusions For UI, there are no prevention trials on lifestyle interventions. There are, however, few new intervention trials of lifestyle interventions involving weight loss and fluid intake with improved levels of evidence and grade of recommendation. Outside of pre- and post-natal pelvic floor muscle training (PFMT) trials for the prevention of female UI, there is a dearth of PFMT prevention trials for women with UI. PFMT remains the first-line treatment for female UI with high levels of evidence and grades of recommendation. Bladder training levels of evidence and grades of recommendation are maintained. For POP, new evidence supports the effectiveness of physiotherapy in the treatment of POP and there are now improved levels of evidence and grades of recommendation.
Resumo:
Aims The objective of the 5th International Consultation on Incontinence (ICI) chapter on Adult Conservative Management was to review and summarize the new evidence on conservative management of urinary incontinence (UI) and pelvic organ prolapse (POP) in order to compile a current reference source for clinicians, health researchers, and service planners. In this paper, we present the review highlights and new evidence on female conservative management. Methods Revision and updates of the 4th ICI Report using systematic review covering years 2008–2012. Results Each section begins with a brief definition and description of the intervention followed by a summary, where possible, of both the state and level of evidence for prevention and treatment, and ends with a “grade of recommendation.” The paper concludes with areas identified as requiring further research. Conclusions For UI, there are no prevention trials on lifestyle interventions. There are, however, few new intervention trials of lifestyle interventions involving weight loss and fluid intake with improved levels of evidence and grade of recommendation. Outside of pre- and post-natal pelvic floor muscle training (PFMT) trials for the prevention of female UI, there is a dearth of PFMT prevention trials for women with UI. PFMT remains the first-line treatment for female UI with high levels of evidence and grades of recommendation. Bladder training levels of evidence and grades of recommendation are maintained. For POP, new evidence supports the effectiveness of physiotherapy in the treatment of POP and there are now improved levels of evidence and grades of recommendation.
Resumo:
Speed control of ac motors requires variable frequency, variable current, or variable voltage supply. Variable frequency supply can be obtained directly from a fixed frequency supply by using a frequency converter or from a dc source using inverters. In this paper a control technique for reference wave adaptive-current generation by modulating the inverter voltage is explained. Extension of this technique for three-phase induction-motor speed control is briefly explained. The oscillograms of the current waveforms obtained from the experimental setup are also shown.
Resumo:
The charge-pump (CP) mismatch current is a dominant source of static phase error and reference spur in the nano-meter CMOS PLL implementations due to its worsened channel length modulation effect. This paper presents a charge-pump (CP) mismatch current reduction technique utilizing an adaptive body bias tuning of CP transistors and a zero CP mismatch current tracking PLL architecture for reference spur suppression. A chip prototype of the proposed circuit was implemented in 0.13 mu m CMOS technology. The frequency synthesizer consumes 8.2 mA current from a 13 V supply voltage and achieves a phase noise of -96.01 dBc/Hz @ 1 MHz offset from a 2.4 GHz RF carrier. The charge-pump measurements using the proposed calibration technique exhibited a mismatch current of less than 0.3 mu A (0.55%) over the VCO control voltage range of 0.3-1.0 V. The closed loop measurements show a minimized static phase error of within +/- 70 ps and a similar or equal to 9 dB reduction in reference spur level across the PLL output frequency range 2.4-2.5 GHz. The presented CP calibration technique compensates for the DC current mismatch and the mismatch due to channel length modulation effect and therefore improves the performance of CP-PLLs in nano-meter CMOS implementations. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
A voltage reference with low sensibility to temperature and power-supply that can generate flexible reference values (from milivolts to several volts) is proposed. Designed for AMS 0.35μm CMOS process, the circuit provides a stable output voltage working in the temperature range of -40-150°C. The proposed reference provides a nominal output voltage of 1.358V with a power-supply of 3.3V. © 2011 IEEE.
Resumo:
In questionable cystic fibrosis (CF), mild or monosymptomatic phenotypes frequently cause diagnostic difficulties despite detailed algorithms. CF transmembrane conductance regulator (CFTR)-mediated ion transport can be studied ex vivo in rectal biopsies by intestinal current measurement (ICM).
Resumo:
"August 6, 1963"
Resumo:
"Government publications" ([87] p. at end) comprise: 1) List of public documents on sale at the Government printing office, Sydney. January, 1911 ... Sydney, 1910. (72 p.)-- 2) List of publications on sale at the Government printing office, Adelaide, S.A. [Adelaide, 1910?] (4 p.)-- 3) Victoria. Government printing office. List of books, pamphlets, etc., on sale. Melbourne, 1911. (9 p.)
Resumo:
"A compilation of many of the most valuable instruction books of the American school of correspondence."--Forword.