893 resultados para Critically-ill cardiac patient


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Whereas most studies focus on laboratory and clinical research, little is known about the causes of death and risk factors for death in critically ill patients. METHODS: Three thousand seven hundred patients admitted to an adult intensive care unit (ICU) were prospectively evaluated. Study endpoints were to evaluate causes of death and risk factors for death in the ICU, in the hospital after discharge from ICU, and within one year after ICU admission. Causes of death in the ICU were defined according to standard ICU practice, whereas deaths in the hospital and at one year were defined and grouped according to the ICD-10 (International Statistical Classification of Diseases and Related Health Problems) score. Stepwise logistic regression analyses were separately calculated to identify independent risk factors for death during the given time periods. RESULTS: Acute, refractory multiple organ dysfunction syndrome was the most frequent cause of death in the ICU (47%), and central nervous system failure (relative risk [RR] 16.07, 95% confidence interval [CI] 8.3 to 31.4, p < 0.001) and cardiovascular failure (RR 11.83, 95% CI 5.2 to 27.1, p < 0.001) were the two most important risk factors for death in the ICU. Malignant tumour disease and exacerbation of chronic cardiovascular disease were the most frequent causes of death in the hospital (31.3% and 19.4%, respectively) and at one year (33.2% and 16.1%, respectively). CONCLUSION: In this primarily surgical critically ill patient population, acute or chronic multiple organ dysfunction syndrome prevailed over single-organ failure or unexpected cardiac arrest as a cause of death in the ICU. Malignant tumour disease and chronic cardiovascular disease were the most important causes of death after ICU discharge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Neurally adjusted ventilatory assist (NAVA) delivers assist in proportion to the patient's respiratory drive as reflected by the diaphragm electrical activity (EAdi). We examined to what extent NAVA can unload inspiratory muscles, and whether unloading is sustainable when implementing a NAVA level identified as adequate (NAVAal) during a titration procedure. METHODS: Fifteen adult, critically ill patients with a Pao(2)/fraction of inspired oxygen (Fio(2)) ratio < 300 mm Hg were studied. NAVAal was identified based on the change from a steep increase to a less steep increase in airway pressure (Paw) and tidal volume (Vt) in response to systematically increasing the NAVA level from low (NAVAlow) to high (NAVAhigh). NAVAal was implemented for 3 h. RESULTS: At NAVAal, the median esophageal pressure time product (PTPes) and EAdi values were reduced by 47% of NAVAlow (quartiles, 16 to 69% of NAVAlow) and 18% of NAVAlow (quartiles, 15 to 26% of NAVAlow), respectively. At NAVAhigh, PTPes and EAdi values were reduced by 74% of NAVAlow (quartiles, 56 to 86% of NAVAlow) and 36% of NAVAlow (quartiles, 21 to 51% of NAVAlow; p < or = 0.005 for all). Parameters during 3 h on NAVAal were not different from parameters during titration at NAVAal, and were as follows: Vt, 5.9 mL/kg predicted body weight (PBW) [quartiles, 5.4 to 7.2 mL/kg PBW]; respiratory rate (RR), 29 breaths/min (quartiles, 22 to 33 breaths/min); mean inspiratory Paw, 16 cm H(2)O (quartiles, 13 to 20 cm H(2)O); PTPes, 45% of NAVAlow (quartiles, 28 to 57% of NAVAlow); and EAdi, 76% of NAVAlow (quartiles, 63 to 89% of NAVAlow). Pao(2)/Fio(2) ratio, Paco(2), and cardiac performance during NAVAal were unchanged, while Paw and Vt were lower, and RR was higher when compared to conventional ventilation before implementing NAVAal. CONCLUSIONS: Systematically increasing the NAVA level reduces respiratory drive, unloads respiratory muscles, and offers a method to determine an assist level that results in sustained unloading, low Vt, and stable cardiopulmonary function when implemented for 3 h.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Hemodynamic management in intensive care patients guided by blood pressure and flow measurements often do not sufficiently reveal common hemodynamic problems. Trans-esophageal echocardiography (TEE) allows for direct measurement of cardiac volumes and function. A new miniaturized probe for TEE (mTEE) potentially provides a rapid and simplified approach to monitor cardiac function. The aim of the study was to assess the feasibility of hemodynamic monitoring using mTEE in critically ill patients after a brief operator training period. METHODS In the context of the introduction of mTEE in a large ICU, 14 ICU staff specialists with no previous TEE experience received six hours of training as mTEE operators. The feasibility of mTEE and the quality of the obtained hemodynamic information were assessed. Three standard views were acquired in hemodynamically unstable patients: 1) for assessment of left ventricular function (LV) fractional area change (FAC) was obtained from a trans-gastric mid-esophageal short axis view, 2) right ventricular (RV) size was obtained from mid-esophageal four chamber view, and 3) superior vena cava collapsibility for detection of hypovolemia was assessed from mid-esophageal ascending aortic short axis view. Off-line blinded assessment by an expert cardiologist was considered as a reference. Inter-rater agreement was assessed using Chi-square tests or correlation analysis as appropriate. RESULTS In 55 patients, 148 mTEE examinations were performed. Acquisition of loops in sufficient quality was possible in 110 examinations for trans-gastric mid-esophageal short axis, 118 examinations for mid-esophageal four chamber and 125 examinations for mid-esophageal ascending aortic short axis view. Inter-rater agreement (Kappa) between ICU mTEE operators and the reference was 0.62 for estimates of LV function, 0.65 for RV dilatation, 0.76 for hypovolemia and 0.77 for occurrence of pericardial effusion (all P < 0.0001). There was a significant correlation between the FAC measured by ICU operators and the reference (r = 0.794, P (one-tailed) < 0.0001). CONCLUSIONS Echocardiographic examinations using mTEE after brief bed-side training were feasible and of sufficient quality in a majority of examined ICU patients with good inter-rater reliability between mTEE operators and an expert cardiologist. Further studies are required to assess the impact of hemodynamic monitoring by mTEE on relevant patient outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Excessive sedation is associated with adverse patient outcomes during critical illness, and a validated monitoring technology could improve care. We developed a novel method, the responsiveness index (RI) of the frontal EMG. We compared RI data with Ramsay clinical sedation assessments in general and cardiac intensive care unit (ICU) patients. Methods. We developed the algorithm by iterative analysis of detailed observational data in 30 medical–surgical ICU patients and described its performance in this cohort and 15 patients recovering from scheduled cardiac surgery. Continuous EMG data were collected via frontal electrodes and RI data compared with modified Ramsay sedation state assessments recorded regularly by a blinded trained observer. RI performance was compared with EntropyTM across Ramsay categories to assess validity. Results. RI correlated well with the Ramsay category, especially for the cardiac surgery cohort (general ICU patients r¼0.55; cardiac surgery patients r¼0.85, both P,0.0001). Discrimination across all Ramsay categories was reasonable in the general ICU patient cohort [PK¼0.74 (SEM 0.02)] and excellent in the cardiac surgery cohort [PK¼0.92 (0.02)]. Discrimination between ‘lighter’ vs ‘deeper’ (Ramsay 1–3 vs 4–6) was good for general ICU patients [PK¼0.80 (0.02)] and excellent for cardiac surgery patients [PK¼0.96 (0.02)]. Performance was significantly better than EntropyTM. Examination of individual cases suggested good face validity. Conclusions. RI of the frontal EMG has promise as a continuous sedation state monitor in critically ill patients. Further investigation to determine its utility in ICU decision-making is warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Given the inaccessibility of indirect calorimetry, intensive care units generally use predictive equations or recommendations that are established by international societies to determine energy expenditure. The aim of the present study was to compare the energy expenditure of critically ill patients, as determined using indirect calorimetry, to the values obtained using the Harris-Benedict equation. Methods: A retrospective observational study was conducted at the Intensive Care Unit 1 of the Centro Hospitalar do Porto. The energy requirements of hospitalized critically ill patients as determined using indirect calorimetry were assessed between January 2003 and April 2012. The accuracy (± 10% difference between the measured and estimated values), the mean differences and the limits of agreement were determined for the studied equations. Results: Eighty-five patients were assessed using 288 indirect calorimetry measurements. The following energy requirement values were obtained for the different methods: 1,753.98±391.13 kcal/ day (24.48 ± 5.95 kcal/kg/day) for indirect calorimetry and 1,504.11 ± 266.99 kcal/day (20.72±2.43 kcal/kg/day) for the HarrisBenedict equation. The equation had a precision of 31.76% with a mean difference of -259.86 kcal/day and limits of agreement between -858.84 and 339.12 kcal/day. Sex (p=0.023), temperature (p=0.009) and body mass index (p< 0.001) were found to significantly affect energy expenditure Conclusion: The Harris-Benedict equation is inaccurate and tends to underestimate energy expenditure. In addition, the Harris-Benedict equation is associated with significant differences between the predicted and true energy expenditure at an individual level

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In critically ill patients, it is important to predict which patients will have their systemic blood flow increased in response to volume expansion to avoid undesired hypovolemia and fluid overloading. Static parameters such as the central venous pressure, the pulmonary arterial occlusion pressure, and the left ventricular end-diastolic dimension cannot accurately discriminate between responders and nonresponders to a fluid challenge. In this regard, respiratory-induced changes in arterial pulse pressure have been demonstrated to accurately predict preload responsiveness in mechanically ventilated patients. Some experimental and clinical studies confirm the usefulness of arterial pulse pressure as a useful tool to guide fluid therapy in critically ill patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of improved microbiological procedures associated with molecular techniques has increased the identification of Candida bloodstream infections, even if the isolation of more than one species by culture methods remains uncommon. We report the cases of two children presenting with severe gastrointestinal disorders and other risk factors that contribute to Candida infections. In the first patient, C. albicans DNA was initially detected by a nested-amplification and C. tropicalis was found later during hospitalization, while blood cultures were persistently negative. In the second child, there was amplification of C. albicans and C. glabrata DNA in the same samples, but blood cultures yielded only C. albicans. Both patients received antifungal therapy but had unfavorable outcomes. These two cases illustrate that PCR was more successful than culture methods in detecting Candida in the bloodstream of high risk children, and was also able to detect the presence of more than one species in the same patient that might impact therapy when the fungi are resistant to azole compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Adequate energy provision and nitrogen losses prevention of critically ill patients are essentials for treatment and recovery. The aims of this study were to evaluate energy expenditure (EE) and nitrogen balance (NB) of critically ill patients, to classify adequacy of energy intake (El), and to verify adequacy of El capacity to reverse the negative NB. Methods: Seventeen patients from an intensive care unit were evaluated within a 24-hour period. Indirect calorimetry was performed to calculate patient`s EE and Kjeldhal for urinary nitrogen analysis. The total El and protein intake were calculated from the standard parenteral and enteral nutrition infused. Underfeeding was characterized as El 90% or less and overfeeding as 110% or greater of EE. The adequacy of the El (El EE(-1) x 100) and the NB were estimated and associated with each other by Spearman coefficient. Results: The mean EE was 1515 +/- 268 kcal d(-1) and most of the patients (11/14) presented a negative NB (-8.2 +/- 4.7 g.d(-1)). A high rate (53%) of inadequate energy intake was found, and a positive correlation between El EE(-1) and NB was observed (r = 0.670; P = .007). Conclusion: The results show a high rate of inadequate El and negative NB, and equilibrium between El and EE may improve NB. Indirect calorimetry can be used to adjust the energy requirements in the critically ill patients. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare the measured energy expenditure (EE) and the estimated basal EE (BEE) in critically ill patients. Materials and Methods: Seventeen patients from an intensive care unit were randomly evaluated. Indirect calorimetry was performed to calculate patient`s EE, and BEE was estimated by the Harris-Benedict formula. The metabolic state (EE/BEE x 100) was determined according to the following criteria: hypermetabolism, more than 130%; normal metabolism, between 90% and 130%; and hypometabolism, less than 90%. To determine the limits of agreement between EE and BEE, we performed a Bland-Altman analysis. Results: The average EE of patients was 6339 +/- 1119 kJ/d. Two patients were hypermetabolic (11.8%), 4 were hypometabolic (23.5%), and 11 normometabolic (64.7%). Bland-Altman analysis showed a mean of -126 +/- 2135 kJ/d for EE and BEE. Only one patient was outside the limits of agreement between the 2 methods (indirect calorimetry and Harris-Benedict). Conclusions: The calculation of energy needs can be done with the equation of Harris-Benedict associated with lower values of correction factors (approximately 10%) to avoid overfeeding, with constant monitoring of anthropometric and biochemical parameters to assess the nutritional changing and adjust the infusion of energy. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seriously ill infants often display protein-calorie malnutrition due to the metabolic demands of sepsis and respiratory failure. Glutamine has been classified as a conditionally essential amino acid, with special usefulness in critical patients. Immunomodulation, gut protection, and prevention of protein depletion are mentioned among its positive effects in such circumstances. With the intent of evaluating the tolerance and clinical impact of a glutamine supplement in seriously ill infants, a prospective randomized study was done with nine patients. Anthropometric and biochemical determinations were made, and length of stay in the intensive care unit (ICU), in the hospital, and under artificial ventilation, and septic morbidity and mortality were tabulated. Infants in the treatment group (n=5) were enterally administered 0.3 g/kg of glutamine, whereas controls received 0.3 g/kg of casein during a standard period of five days. Septic complications occurred in 75% of the controls (3/4) versus 20% of the glutamine-treated group (1/5, p<=0.10), and two patients in the control group died of bacterial infections (50% vs. 0%, p<=0.10). Days in the ICU, in the hospital, and with ventilation numerically favored glutamine therapy, although without statistical significance. The supplements were usually well tolerated, and no patient required discontinuation of the program. The conclusion was that glutamine supplementation was safe and tended to be associated with less infectious morbidity and mortality in this high-risk population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Few studies have tried to characterize the efficacy of parenteral support of critically ill infants during short period of intensive care. We studied seventeen infants during five days of total parenteral hyperalimentation. Subsequently, according to the clinical conditions, the patients received nutritional support by parenteral, enteral route or both up to the 10th day. Evaluations were performed on the 1st, 5th, and 10th days. These included: clinical data (food intake and anthropometric measurements), haematological data (lymphocyte count), biochemical tests (albumin, transferrin, fibronectin, prealbumin, retinol-binding protein) and hormone assays (cortisol, insulin, glucagon). Anthropometric measurements revealed no significant difference between the first and second evaluations. Serum albumin and transferrin did not change significantly, but mean values of fibronectin (8.9 to 16 mg/dL), prealbumin (7.7 to 18 mg/dL), and retinol-binding protein (2.4 to 3.7 mg/dL) increased significantly (p < 0.05) from the 1st to the 10th day. The hormonal study showed no difference for insulin, glucagon, and cortisol when the three evaluations were compared. The mean value of the glucose/insulin ratio was of 25.7 in the 1st day and 15.5 in the 5th day, revealing a transitory supression of this hormone. Cortisol showed values above normal in the beginning of the study. We conclude that the anthropometric parameters were not useful due to the short time of the study; serum proteins, fibronectin, prealbumin, and retinol-binding protein were very sensitive indicators of nutritional status, and an elevated glucose/insulin ratio, associated with a slight tendency for increased cortisol levels suggest hypercatabolic state. The critically ill patient can benefit from an early metabolic support.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND & AIMS: The study was designed to investigate and quantify nutritional support, and particularly enteral nutrition (EN), in critically ill patients with severe hemodynamic failure. METHODS: Prospective, descriptive study in a surgical intensive care unit (ICU) in a university teaching hospital: patients aged 67+/-13 yrs (mean+/-SD) admitted after cardiac surgery with extracorporeal circulation, staying 5 days in the ICU with acute cardiovascular failure. Severity of disease was assessed with SAPS II, and SOFA scores. Variables were energy delivery and balance, nutrition route, vasopressor doses, and infectious complications. Artificial feeding delivered according to ICU protocol. EN was considered from day 2-3. Energy target was set 25 kcal/kg/day to be reached stepwise over 5 days. RESULTS: Seventy out of 1114 consecutive patients were studied, aged 67+/-17 years, and staying 10+/-7 days in the ICU. Median SAPS II was 43. Nine patients died (13%). All patients had circulatory failure: 18 patients required intra-aortic balloon-pump support (IABP). Norepinephrine was required in 58 patients (83%). Forty patients required artificial nutrition. Energy delivery was very variable. There was no abdominal complication related to EN. As a mean, 1360+/-620 kcal/kg/day could be delivered enterally during the first 2 weeks, corresponding to 70+/-35% of energy target. Enteral nutrient delivery was negatively influenced by increasing dopamine and norepinephrine doses, but not by the use of IABP. CONCLUSION: EN is possible in the majority of patients with severe hemodynamic failure, but usually results in hypocaloric feeding. EN should be considered in patients with careful abdominal and energy monitoring.