993 resultados para Cool roofs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-resolution data from the TRMM satellite shows that sea surface temperature (SST) cools by 3 degrees C under the tracks of pre-monsoon tropical cyclones in the north Indian Ocean. However, even the strongest post-monsoon cyclones do not cool the open north Bay of Bengal. In this region, a shallow layer of freshwater from river runoff and monsoon rain caps a deep warm layer. Therefore, storm-induced mixing is not deep, and it entrains warm subsurface water. It is possible that the hydrography of the post-monsoon north Bay favours intense cyclones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the cool roof technology effects on annual energy saving of a large one-storey commercial building in Queensland, Australia. A computer model of the case study was developed using commercial software by using the appropriate geometrical and thermal building specifications. Field study data were used to validate the model. The model was then used to extend the investigation to other cities in various Australian climate zones. The results of this research show that significant energy savings can be obtained using cool roof technology, particularly in warm, sunny climates, and the thesis can contribute to provide a guideline for application of cool roof technology to single-storey commercial building throughout Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Barramundi Lates calcarifer reared in cool water (20-22 degrees C) grow slowly and feed is used poorly compared with fish in warm water (28-32 degrees C). Two comparative slaughter growth assays were carried out with juvenile barramundi to see if increasing the digestible energy (DE) and/or the n-3 highly unsaturated fatty acid (n-3 HUFA) content of the feed would improve growth of fish raised in cool water. Increasing the DE content of the feed from 15 to 17 or 19 MJ kg(-1) while maintaining a constant protein to energy ratio in Experiment 1 brought about significant improvements in feed conversion ratio (FCR) (from 2.01 to 1.19) and daily growth coefficient (DGC; from 0.69 to 1.08%/day) for fish at 20 degrees C. For fish at 29 degrees C, improvements, while significant, were of a lesser magnitude: from 1.32 to 0.97 for FCR and from 3.24 to 3.65%/day for DGC. Increasing the absolute amount of dietary n-3 HUFA, expressed as the sum of eicosapentaenoic and docosahexaenoic fatty acids, from 0.5% to 2.0% in Experiment 2 improved DGC linearly and FCR curvilinearly for fish at 29 degrees C whereas at 20 degrees C, DGC was not affected while FCR improved slightly (from 1.83 to 1.68). Feed conversion ratio was optimized with a dietary n-3 HUFA of about 1.5%. Providing barramundi with a feed that is high in DE (viz 19 MJ kg(-1)) and a digestible protein to DE ratio of 22.5 g MJ(-1) is a practical strategy for improving the productivity of barramundi cultured in cool water whereas increasing dietary n-3 HUFA conferred very little additional benefit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biosecurity problem addressed was the need to understand and evaluate phosphine fumigation of cool grain (i.e. 20°C or less) as a means of controlling resistant biotypes of insect pests of stored grain which are major EPPs threatening the grain industry. The benefits of cooling and phosphine fumigation are that cooling preserves grain quality and reduces insect population growth, and phosphine kills insects and has a residue free status in all major markets. The research objectives were to: - conduct laboratory experiments on phosphine efficacy against resistant insects in cool grain, and determine times to population extinction. - conduct laboratory experiments on phosphine sorption in cool grain and quantify. - complete fumigation trials in three states (Queensland, WA and NSW) on cool grain stored insealed farm silos. - make recommendations for industry on effective phosphine fumigation of cool grain. Phosphine is used by growers and other stakeholders in the grain industry to meet domesticand international demands for insect-free grain. The project aim was to generate new information on the performance of phosphine fumigation of cool grain relevant to resistant biotypes. Effective control of resistant biotypes using phosphine to fumigate cool grain will benefit growers and other sectors of the grain industry, needing to fumigate grain in the cooler months of the year, or grain that has been cooled using aeration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Impervious surfaces in an urban catchment are the primary stormwater pollutant contributing areas. Appropriate treatment of stormwater runoff from these impervious surfaces is essential to safeguard the urban water environment. While urban roads have received significant research attention in this regard, roofs have not been well investigated. Key pollutant processes such as build-up on roads and roofs can be different due to the different surface characteristics. This entails different treatment strategies being needed for road and roofs. The research study characterized roof pollutants build-up by differentiating with road surfaces. It was noted that pollutants are more highly concentrated on particles and particularly finer particles in the case of roof surfaces, compared to road surfaces. Additionally, pollutants built-up on roof surfaces tend to be relatively more variable from one day to another in terms of pollutant loads. These results highlight the significance of roofs as a stormwater pollutant source and the important need for a specific stormwater treatment strategy rather than the application of a combined approach for treating stormwater runoff from both, roads and roofs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fast content addressable data access mechanisms have compelling applications in today's systems. Many of these exploit the powerful wildcard matching capabilities provided by ternary content addressable memories. For example, TCAM based implementations of important algorithms in data mining been developed in recent years; these achieve an an order of magnitude speedup over prevalent techniques. However, large hardware TCAMs are still prohibitively expensive in terms of power consumption and cost per bit. This has been a barrier to extending their exploitation beyond niche and special purpose systems. We propose an approach to overcome this barrier by extending the traditional virtual memory hierarchy to scale up the user visible capacity of TCAMs while mitigating the power consumption overhead. By exploiting the notion of content locality (as opposed to spatial locality), we devise a novel combination of software and hardware techniques to provide an abstraction of a large virtual ternary content addressable space. In the long run, such abstractions enable applications to disassociate considerations of spatial locality and contiguity from the way data is referenced. If successful, ideas for making content addressability a first class abstraction in computing systems can open up a radical shift in the way applications are optimized for memory locality, just as storage class memories are soon expected to shift away from the way in which applications are typically optimized for disk access locality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using high-resolution 3D and 2D (axisymmetric) hydrodynamic simulations in spherical geometry, we study the evolution of cool cluster cores heated by feedback-driven bipolar active galactic nuclei (AGNs) jets. Condensation of cold gas, and the consequent enhanced accretion, is required for AGN feedback to balance radiative cooling with reasonable efficiencies, and to match the observed cool core properties. A feedback efficiency (mechanical luminosity approximate to epsilon(M) over dot(acc)c(2); where (M) over dot(acc). is the mass accretion rate at 1 kpc) as small as 6 x 10(-5) is sufficient to reduce the cooling/accretion rate by similar to 10 compared to a pure cooling flow in clusters (with M-200 less than or similar to 7 x 10(14) M-circle dot). This value is much smaller compared to the ones considered earlier, and is consistent with the jet efficiency and the fact that only a small fraction of gas at 1 kpc is accreted onto the supermassive black hole (SMBH). The feedback efficiency in earlier works was so high that the cluster core reached equilibrium in a hot state without much precipitation, unlike what is observed in cool-core clusters. We find hysteresis cycles in all our simulations with cold mode feedback: condensation of cold gas when the ratio of the cooling-time to the free-fall time (t(cool)/t(ff)) is less than or similar to 10 leads to a sudden enhancement in the accretion rate; a large accretion rate causes strong jets and overheating of the hot intracluster medium such that t(cool)/t(ff) > 10; further condensation of cold gas is suppressed and the accretion rate falls, leading to slow cooling of the core and condensation of cold gas, restarting the cycle. Therefore, there is a spread in core properties, such as the jet power, accretion rate, for the same value of core entropy t(cool)/t(ff). A smaller number of cycles is observed for higher efficiencies and for lower mass halos because the core is overheated to a longer cooling time. The 3D simulations show the formation of a few-kpc scale, rotationally supported, massive (similar to 10(11) M-circle dot) cold gas torus. Since the torus gas is not accreted onto the SMBH, it is largely decoupled from the feedback cycle. The radially dominant cold gas (T < 5 x 10(4) K; vertical bar v(r)vertical bar >vertical bar v(phi vertical bar)) consists of fast cold gas uplifted by AGN jets and freely infalling cold gas condensing out of the core. The radially dominant cold gas extends out to 25 kpc for the fiducial run (halo mass 7 x 10(14) M-circle dot and feedback efficiency 6 x 10(-5)), with the average mass inflow rate dominating the outflow rate by a factor of approximate to 2. We compare our simulation results with recent observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precipitation is a difficult variable to understand and predict. In this study, monthly precipitation in California is divided into two classes according to the monthly temperature to better diagnose the atmospheric circulation that causes precipitation, and to illustrate how temperature compounds the precipitation to runoff process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wintertime precipitation in the mountains of the western United States during a warm or cool period has a pronounced influence on streamflow. During a warm year, streamflow at intermediate elevations responds more immediately to precipitation events; during a cold year, much of the discharge is delayed until the snow melts in spring and summer. Previous efforts at studying these extremes have been hampered by a limited number and length of observational analyses. In this study, we augment this limited observational record by analyzing a simplified general circulation model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Building integrated photovoltaics (BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influence on the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. Four different roofs are used to assess the impacts of BIPV on the building's heating-and-cooling loads; namely ventilated air-gap BIPV, non-ventilated (closed) air-gap BIPV, closeroof mounted BIPV, and the conventional roof with no PV and no air gap. One-dimensional transient models of four cases are derived to evaluate the PV performances and building cooling-and-heating loads across the different roofs in order to select the appropriate PV building integration method in Tianjin, China. The simulation results show that the PV roof with ventilated air-gap is suitable for the application in summer because this integration leads to the low cooling load and high PV conversion efficiency. The PV roof with ventilation air-gap has a high time lag and small decrement factor in comparison with other three roofs and has the same heat gain as the cool roof of absorptance 0.4. In winter, BIPV of non-ventilated air gap is more appropriate due to the combination of the low heating-load through the PV roof and high PV electrical output. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Green roofs are one solution to stormwater runoff which is a major environmental problem. However, the majority of green roofs are primarily implemented on flat roofed commercial buildings and not residential homes with sloped roofs. Team SO GREEN designed a light-weight green roof system retrofit for residential homes. Between June and November 2014, green roof performance data was collected and compared between the designed sloped roofs and a non-sloped control. The sloped design performed well and one test slope was improved with a recirculating irrigation system. An economic analysis was made and a focus group determined preliminary consumer interest, aesthetic preferences, and barriers. This study enriches the body of knowledge regarding bringing green roof systems to the residential home market.