860 resultados para Controller
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2011
Resumo:
Introduction: Isocyanates are sensitizing chemicals used in various industries such as polyurethane foam production or paint-related purposes. Acting as haptens recognized by T-lymphocytes, they can cause allergic asthma and rarely hypersensitivity pneumonitis (HP). We aim to present a case report of acute HP due to hexamethylene diisocyanate (HDI) in a paint quality controller, a profession not generally considered at a high risk for work-related Isocyanates exposure. Case report: A 30-yr-old otherwise healthy female, light smoker working as a paint quality controller developed shortness of breath, malaise, sweating and chills at workplace six hours after handling a HDI-based hardener. Upon admission to emergency department, symptoms had progressed to severe respiratory failure. HR computer tomography (HRCT) showed bilateral ground-glass attenuation without pleural effusion. Rapid clinical and radiological improvement occurred under facial oxygen supply and systemic steroid therapy. Occupational medicine investigations revealed regular handling of HDI using latex gloves without respiratory protection. Assessment at workplace showed insufficient air renewal (1.5 times per hour), inadequate local aspiration and HDI exposure at levels of 1-4.25 ppb/m3 (Swiss Occupation Exposure Limit 5 ppb/m3). Biological monitoring after identical work procedure executed by a co-worker showed HDI exposure (5.1 micrograms hexamethylene diamine/g creatinine). Resumption of work was disadvised because of the life-threatening event. Discussion: The diagnosis of occupational HP is highly supported by classical findings on imagery and typical symptoms occurring within approved latency interval, associated with rapid clinical improvement. Although neither broncho-alveolar lavage nor specific IgG diagnosis (en route) were performed during the acute episode, various blood tests managed to rule out evidence of an infection or autoimmune disease. Other causes of HP seem unlikely as the patient did not have any recurrence of symptoms since absence from work. Workplace evaluation provided significant information on HDI exposure and allowed substantial recommendations to diminish Isocyanate exposure for the 20 still healthy laboratory co-workers. Although the entryways (air or skin) and precise mechanism of toxicity remain unclear, the present case clearly shows that Isocyanates may trigger acute HP in susceptible workers in a profession not generally considered at a high risk.
Resumo:
Este proyecto tiene como objetivo crear y aplicar una metodología a una aplicación llamada MATE que fue creada en en el año 2003 por Anna Sikora para su tesis doctoral. Se trata de dotar el proyecto MATE de las herramientas necesarias para garantizar su evolución. La metodología creada consta de la especificación de un entorno de trabajo y una serie de documentos que detallan los procesos relativos al desarrollo de MATE. Además se han creado algunas nuevas características que hacen de MATE una herramienta más completa y cómoda.
Resumo:
OBJECTIVE: To study the causes for the lack of clinical progression in a superinfected HIV-1 LTNP elite controller patient.¦METHODOLOGY AND PRINCIPAL FINDINGS: We studied host genetic, virological and immunological factors associated with viral control in a SI long term non progressor elite controller (LTNP-EC). The individual contained both viruses and maintained undetectable viral loads for >20 years and he did not express any of the described host genetic polymorphisms associated with viral control. None of four full-length gp160 recombinants derived from the LTNP-EC replicated in heterologous peripheral blood mononuclear cells. CTL responses after SI were maintained in two samples separated by 9 years and they were higher in breadth and magnitude than responses seen in most of 250 treatment naïve patients and also 25 controller subjects. The LTNP-EC showed a neutralization response, against 4 of the 6 viruses analyzed, superior to other ECs.¦CONCLUSIONS: The study demonstrated that a strong and sustained cellular and humoral immune response and low replicating viruses are associated with viral control in the superinfected LTNP-EC.
Resumo:
HIV-1 diagnosis is usually based on the detection of specific antibodies, appearing in a time-determined pattern following the infection. We describe a prolonged HIV-1 seroconversion in an elite controller (defined as having HIV-1 RNA persistently <50copies/ml while untreated). HIV-1 diagnosis was delayed and complicated by this atypical evolution.
Resumo:
BACKGROUND: Occupational diisocyanate-induced extrinsic allergic alveolitis (EAA) is a rare and probably underestimated diagnosis. Two acute occupational EAA cases have been described in this context, but neither of them concerned hexamethylene diisocyanate (HDI) exposure. AIMS: To investigate the cause of a life-threatening EAA arising at work in a healthy 30-year-old female paint quality controller. METHODS: Occupational medical assessment, workplace evaluation, airborne and biological monitoring and immunodermatological tests. RESULTS: Diagnosis of EAA relied on congruent clinical and radiological information, confirmed occupational HDI exposure and positive IgG antibodies and patch tests. The patient worked in a small laboratory for 7 years, only occasionally using HDI-containing hardeners. While working with HDI for 6 h, she developed breathlessness, rapidly progressing to severe respiratory failure. Workplace HDI airborne exposure values ranged from undetectable levels to 4.25 p.p.b. Biological monitoring of urinary hexamethylene diamine in co-workers ranged from <1.0 to 15.4 μg/g creatinine. Patch tests 8 months later showed delayed skin reaction to HDI at 48 h. Subsequent skin biopsy showed spongiotic dermatitis with infiltration of CD4(+) and CD8(+) T cells. CONCLUSIONS: We believe this is the first reported case of acute life-threatening EAA following exposure to HDI. Low concentrations of airborne HDI and relatively high urinary hexamethylene diamine suggest significant skin absorption of HDI could have significantly contributed to the development of this acute occupational EAA.
Resumo:
Type 1 diabetic patients depend on external insulin delivery to keep their blood glucose within near-normal ranges. In this work, two robust closed-loop controllers for blood glucose regulation are developed to prevent the life-threatening hypoglycemia, as well as to avoid extended hyperglycemia. The proposed controllers are designed by using the sliding mode control technique in a Smith predictor structure. To improve meal disturbance rejection, a simple feedforward controller is added to inject meal-time insulin bolus. Simulations scenarios were used to test the controllers, and showed the controllers ability to maintain the glucose levels within the safe limits in the presence of errors in measurements, modeling and meal estimation
Resumo:
This paper presents a control strategy for blood glucose(BG) level regulation in type 1 diabetic patients. To design the controller, model-based predictive control scheme has been applied to a newly developed diabetic patient model. The controller is provided with a feedforward loop to improve meal compensation, a gain-scheduling scheme to account for different BG levels, and an asymmetric cost function to reduce hypoglycemic risk. A simulation environment that has been approved for testing of artificial pancreas control algorithms has been used to test thecontroller. The simulation results show a good controller performance in fasting conditions and meal disturbance rejection, and robustness against model–patient mismatch and errors in mealestimation
Resumo:
IP-verkkojen hyvin tunnettu haitta on, että nämä eivät pysty takaamaan tiettyä palvelunlaatua (Quality of Service) lähetetyille paketeille. Seuraavat kaksi tekniikkaa pidetään lupaavimpina palvelunlaadun tarjoamiselle: Differentiated Services (DiffServ) ja palvelunlaatureititys (QoS Routing). DiffServ on varsin uusi IETF:n määrittelemä Internetille tarkoitettu palvelunlaatumekanismi. DiffServ tarjoaa skaalattavaa palvelujen erilaistamista ilman viestintää joka hypyssä ja per-flow –tilan ohjausta. DiffServ on hyvä esimerkki hajautetusta verkkosuunnittelusta. Tämän palvelutasomekanismin tavoite on viestintäjärjestelmien suunnittelun yksinkertaistaminen. Verkkosolmu voidaan rakentaa pienestä hyvin määritellystä rakennuspalikoiden joukosta. Palvelunlaatureititys on reititysmekanismi, jolla liikennereittejä määritellään verkon käytettävissä olevien resurssien pohjalta. Tässä työssä selvitetään uusi palvelunlaatureititystapa, jota kutsutaan yksinkertaiseksi monitiereititykseksi (Simple Multipath Routing). Tämän työn tarkoitus on suunnitella palvelunlaatuohjain DiffServille. Tässä työssä ehdotettu palvelunlaatuohjain on pyrkimys yhdistää DiffServ ja palvelunlaatureititysmekanismeja. Työn kokeellinen osuus keskittyy erityisesti palvelunlaatureititysalgoritmeihin.
Resumo:
The study assessed growth and physiological parameters of 'Sunrise Golden' and 'Tainung 01' papaya seedlings grown in 280mL plastic tubes and watered using a low-cost automatic irrigation system adjusted to operate at substrate water tension for starting irrigation (STI) of 3.0, 6.0 or 9.0 kPa. The water depths applied by the dripping system and drainage were monitored during germination and seedling growth. Germination, emergence velocity index (EVI), leaf area, plant height, shoot and root dry weight, stomatal conductance, relative water content (RWC) and relative chlorophyll content (RCC) were evaluated. Soil nutrient levels were determined by electrical conductivity (EC). Water use efficiency (WUE) corresponded to the ratio of plant dry mass to depth of water applied. STI settings did not affect papaya germination or EVI. System configuration to 3.0 and 6.0 kPa STI exhibited the highest drainage and lowest EC and RCC, indicating soil nutrient loss and plant nutrient deficiency. Drainage was greater in tubes planted with the 'Tainung 01' variety, which developed smaller root systems and lower stomatal conductance than 'Sunrise Golden' seedlings. The highest values for shoot dry weight and WEU were obtained at 6.0 kPa STI for 'Sunrise Golden' (0.62 g and 0.69 g L-1) and at 9.0 kPa in 'Tainung 01' (0.35 g and 0.82 g L-1). RWC at 9.0 kPa STI was lower than at 3.0 kPa in both varieties. The results indicate that the low-cost technology developed for irrigation automation is promising. Even so, new studies are needed to evaluate low-flow irrigation systems as well as the nutrient and water needs of different papaya varieties.
Resumo:
The time required to image large samples is an important limiting factor in SPM-based systems. In multiprobe setups, especially when working with biological samples, this drawback can make impossible to conduct certain experiments. In this work, we present a feedfordward controller based on bang-bang and adaptive controls. The controls are based in the difference between the maximum speeds that can be used for imaging depending on the flatness of the sample zone. Topographic images of Escherichia coli bacteria samples were acquired using the implemented controllers. Results show that to go faster in the flat zones, rather than using a constant scanning speed for the whole image, speeds up the imaging process of large samples by up to a 4x factor.
Resumo:
This master’s thesis is focused on the active magnetic bearings control, specifically the robust control. As carrying out of such kind of control used mixed H2/Hinf controller. So the goal of this work is to design it using Robust Control Toolbox™ in MATLAB and compare it performance and robustness with Hinf robust controller characteristics. But only one degree-of-freedom controller considered.
Resumo:
The thesis studies possibility of using embedded controller in a crane application and furthermore defines requirements when designing such a controller. Basic crane control architectures are considered and compared. Then embedded controller product life cycle is described: considering such issues like microcontroller selection, software/hardware design and application development tools. Finally, available embedded controller is described and used for implementing crane control.
Resumo:
ABSTRACT Microsprinkler non-pressure compensating nozzles usually show water flow variation along the lateral line. This study aimed at adapting microtubes into non-compensating system of microsprinklers previous installed in the field, as a self-compensated nozzle, to improve the flow uniformity along the lateral line. Microtubes were adapted to three types of commercial microsprinklers. Tests were conducted, both in the laboratory and in field, to evaluate the microsprinkler performance at four different flows (40, 50, 60 and 70 L h-1) under pressure head range from 75 to 245 kPa. Nozzles presented coefficient of flow-rate variation (CVq) lower than 5.5% and distribution uniformity (DU) greater than 95%, which are classified as excellent. The original spatial water distribution of the microsprinkler did not change by using microtube as a nozzle. This device adapted to non-pressure compensating microsprinklers are functional and operate effectively with flows ranging up to 70 L h-1. Small variations at microsprinkler flows along the lateral line can occur, however, at random manner, which is common for pressure-compensating nozzles. Therefore, the microtube technique is able to control pressure variation in microsprinklers.
Model-View-Controller architectural pattern and its evolution in graphical user interface frameworks
Resumo:
Model-View-Controller (MVC) is an architectural pattern used in software development for graphical user interfaces. It was one of the first proposed solutions in the late 1970s to the Smart UI anti-pattern, which refers to the act of writing all domain logic into a user interface. The original MVC pattern has since evolved in multiple directions, with various names and may confuse many. The goal of this thesis is to present the origin of the MVC pattern and how it has changed over time. Software architecture in general and the MVC’s evolution within web applications are not the primary focus. Fundamen- tal designs are abstracted, and then used to examine the more recent versions. Prob- lems with the subject and its terminology are also presented.