996 resultados para Computerized assessment
Resumo:
This research describes a computerized model of human classification which has been constructed to represent the process by which assessments are made for psychodynamic psychotherapy. The model assigns membership grades (MGs) to clients so that the most suitable ones have high values in the therapy category. Categories consist of a hierarchy of components, one of which, ego strength, is analysed in detail to demonstrate the way it has captured the psychotherapist's knowledge. The bottom of the hierarchy represents the measurable factors being assessed during an interview. A questionnaire was created to gather the identified information and was completed by the psychotherapist after each assessment. The results were fed into the computerized model, demonstrating a high correlation between the model MGs and the suitability ratings of the psychotherapist (r = .825 for 24 clients). The model has successfully identified the relevant data involved in assessment and simulated the decision-making process of the expert. Its cognitive validity enables decisions to be explained, which means that it has potential for therapist training and also for enhancing the referral process, with benefits in cost effectiveness as well as in the reduction of trauma to clients. An adapted version measuring client improvement would give quantitative evidence for the benefit of therapy, thereby supporting auditing and accountability. © 1997 The British Psychological Society.
Resumo:
Attention deficit, impulsivity and hyperactivity are the cardinal features of attention deficit hyperactivity disorder (ADHD) but executive function (EF) disorders, as problems with inhibitory control, working memory and reaction time, besides others EFs, may underlie many of the disturbs associated with the disorder. OBJECTIVE: To examine the reaction time in a computerized test in children with ADHD and normal controls. METHOD: Twenty-three boys (aged 9 to 12) with ADHD diagnosis according to Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, 2000 (DSM-IV) criteria clinical, without comorbidities, Intelligence Quotient (IQ) >89, never treated with stimulant and fifteen normal controls, age matched were investigated during performance on a voluntary attention psychophysical test. RESULTS: Children with ADHD showed reaction time higher than normal controls. CONCLUSION: A slower reaction time occurred in our patients with ADHD. This findings may be related to problems with the attentional system, that could not maintain an adequate capacity of perceptual input processes and/or in motor output processes, to respond consistently during continuous or repetitive activity.
Resumo:
OBJECTIVE: To use magnetic resonance imaging (MRI) to validate estimates of muscle and adipose tissue (AT) in lower limb sections obtained by dual-energy X-ray absorptiometry (DXA) modelling. DESIGN: MRI measurements were used as reference for validating limb muscle and AT estimates obtained by DXA models that assume fat-free soft tissue (FFST) comprised mainly muscle: model A accounted for bone hydration only; model B also applied constants for FFST in bone and skin and fat in muscle and AT; model C was as model B but allowing for variable fat in muscle and AT. SUBJECTS: Healthy men (n = 8) and women (n = 8), ages 41 - 62 y; mean (s.d.) body mass indices (BMIs) of 28.6 (5.4) kg/m(2) and 25.1 (5.4) kg/m2, respectively. MEASUREMENTS: MRI scans of the legs and whole body DXA scans were analysed for muscle and AT content of thigh (20 cm) and lower leg (10 cm) sections; 24 h creatinine excretion was measured. RESULTS: Model A overestimated thigh muscle volume (MRI mean, 2.3 l) substantially (bias 0.36 l), whereas model B underestimated it by only 2% (bias 0.045 l). Lower leg muscle (MRI mean, 0.6 l) was better predicted using model A (bias 0.04 l, 7% overestimate) than model B (bias 0.1 l, 17% underestimate). The 95% limits of agreement were high for these models (thigh,+/- 20%; lower leg,+/- 47%). Model C predictions were more discrepant than those of model B. There was generally less agreement between MRI and all DXA models for AT. Measurement variability was generally less for DXA measurements of FFST (coefficient of variation 0.7 - 1.8%) and fat (0.8 - 3.3%) than model B estimates of muscle (0.5-2.6%) and AT (3.3 - 6.8%), respectively. Despite strong relationships between them, muscle mass was overestimated by creatinine excretion with highly variable predictability. CONCLUSION: This study has shown the value of DXA models for assessment of muscle and AT in leg sections, but suggests the need to re-evaluate some of the assumptions upon which they are based.
Resumo:
Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
Resumo:
There seems to be controversy on the anorectal sphincter presentation and anatomical division, as well as on its functional representation. Evaluation of the anorectal sphincter musculature has been achieved through several methods, including anorectal manometry and computerized tomography, but to date there is no experimental model allowing a detailed manometric study of this muscle complex. In this work, we have developed such a model, which should enable the manometric and radiographic study of the anatomical features and functional mechanisms of sphincteric injuries, as well as the assessment of drug effects on the anorectal musculature upon incontinence and constipation. Twenty-two piglets (aged 25-30 days, weighing 5-7 kg) were studied by anorectal manometry (rectoanal inhibitory reflex and vector volume) and computerized tomography (anorectal angle and anal canal length). The data obtained for the rectoanal inhibitory reflex, represented here as the average and standard deviation, were the following: relaxation duration = 14.75 +/- 3.62 s, sphincter basal pressure = 41.58 +/- 8.20 mmHg, relaxation index = 87.26 +/- 11.52%, speed of relaxation = 5.90 +/- 2.10 mm/s, and speed of relaxation recovery = 4.03 +/- 1.78 mm/s. As for the vector volume, results were as follows: vector volume = 2692.32 +/- 1298.12 mmHg(2) cm, sphincter length = 11.82 +/- 2.74 mm, high pressure zone length = 5.09 +/- 1.34 mm, maximum pressure = 61.50 +/- 20.58 mmHg, and asymmetry index = 43.50 +/- 10.03%. Radiographic evaluation led to the following results: anal canal length = 9.61 +/- 2.14 mm and anorectal angle = 137.91 +/- 7.75 degrees. The experimental model designed here allows both anorectal manometry and computerized tomography to be carried out in the same way it is performed in human beings, as long as animal sedation is strictly controlled.
Resumo:
Background: The Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index is a previously described self-administered questionnaire covering three domains: pain, stiffness and function. It has been validated in patients with osteoarthritis (OA) of the hip or knee in a paper-based format. Aim: To validate the WOMAC 3.0 using a numerical rating scale in a computerized touch screen format allowing immediate evaluation of the questionnaire. In the computed version cartoons, written and audio instruments were included in order facilitate application. Methods: Fifty patients, demographically balanced, with radiographically proven primary hip or knee OA completed the classical paper and the new computerized WOMAC version. Subjects were randomized either to paper format or computerized format first to balance possible order effects, Results: The intra-class correlation coefficients for pain, stiffness and function values were 0.915, 0.745 and 0.940, respectively. The Spearman correlation coefficients for pain, stiffness and function were 0.88, 0.77 and 0.87, respectively. Conclusion: These data indicate that the computerized WOMAC OA index 3.0 is comparable to the paper WOMAC in all three dimensions. The computerized version would allow physicians to get an immediate result and if present a direct comparison with a previous exam. (C) 2002 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.
Resumo:
A computerized handheld procedure is presented in this paper. It is intended as a database complementary tool, to enhance prospective risk analysis in the field of occupational health. The Pendragon forms software (version 3.2) has been used to implement acquisition procedures on Personal Digital Assistants (PDAs) and to transfer data to a computer in an MS-Access format. The data acquisition strategy proposed relies on the risk assessment method practiced at the Institute of Occupational Health Sciences (IST). It involves the use of a systematic hazard list and semi-quantitative risk assessment scales. A set of 7 modular forms has been developed to cover the basic need of field audits. Despite the minor drawbacks observed, the results obtained so far show that handhelds are adequate to support field risk assessment and follow-up activities. Further improvements must still be made in order to increase the tool effectiveness and field adequacy.
Resumo:
OBJECT: In this study the accuracy of multislice computerized tomography (MSCT) angiography in the postoperative examination of clip-occluded intracranial aneurysms was compared with that of intraarterial digital subtraction (DS) angiography METHODS: Forty-nine consecutive patients with 60 clipped aneurysms (41 of which had ruptured) were studied with the aid of postoperative MSCT and DS angiography. Both types of radiological studies were reviewed independently by two observers to assess the quality of the images, the artifacts left by the clips, the completeness of aneurysm occlusion, the patency of the parent vessel, and the duration and cost of the examination. The quality of MSCT angiography was good in 42 patients (86%). Poor-quality MSCT angiograms (14%) were a result of the late acquisition of images in three patients and the presence of clip or motion artifacts in four. Occlusion of the aneurysm on good-quality MSCT angiograms was confirmed in all but two patients in whom a small (2-mm) remnant was confirmed on DS angiograms. In one patient, occlusion of a parent vessel was seen on DS angiograms but missed on MSCT angiograms. The sensitivity and specificity for detecting neck remnants on MSCT angiography were both 100%, and the sensitivity and specificity for evaluating vessel patency were 80 and 100%, respectively (95% confidence interval 29.2-100%). Interobserver agreements were 0.765 and 0.86, respectively. The mean duration of the examination was 13 minutes for MSCT angiography and 75 minutes for DS angiography (p < 0.05). Multislice CT angiography was highly cost effective (p < 0.01). CONCLUSIONS: Current-generation MSCT angiography is an accurate noninvasive tool used for assessment of clipped aneurysms in the anterior circulation. Its high sensitivity and low cost warrant its use for postoperative routine control examinations following clip placement on an aneurysm. Digital subtraction angiography must be performed if the interpretation of MSCT angiograms is doubtful or if the aneurysm is located in the posterior circulation.
Resumo:
OBJECTIVE To analyze the usability of Computerized Nursing Process (CNP) from the ICNP® 1.0 in Intensive Care Units in accordance with the criteria established by the standards of the International Organization for Standardization and the Brazilian Association of Technical Standards of systems. METHOD This is a before-and-after semi-experimental quantitative study, with a sample of 34 participants (nurses, professors and systems programmers), carried out in three Intensive Care Units. RESULTS The evaluated criteria (use, content and interface) showed that CNP has usability criteria, as it integrates a logical data structure, clinical assessment, diagnostics and nursing interventions. CONCLUSION The CNP is a source of information and knowledge that provide nurses with new ways of learning in intensive care, for it is a place that provides complete, comprehensive, and detailed content, supported by current and relevant data and scientific research information for Nursing practices.
Resumo:
BACKGROUND: Human speech is greatly influenced by the speakers' affective state, such as sadness, happiness, grief, guilt, fear, anger, aggression, faintheartedness, shame, sexual arousal, love, amongst others. Attentive listeners discover a lot about the affective state of their dialog partners with no great effort, and without having to talk about it explicitly during a conversation or on the phone. On the other hand, speech dysfunctions, such as slow, delayed or monotonous speech, are prominent features of affective disorders. METHODS: This project was comprised of four studies with healthy volunteers from Bristol (English: n = 117), Lausanne (French: n = 128), Zurich (German: n = 208), and Valencia (Spanish: n = 124). All samples were stratified according to gender, age, and education. The specific study design with different types of spoken text along with repeated assessments at 14-day intervals allowed us to estimate the 'natural' variation of speech parameters over time, and to analyze the sensitivity of speech parameters with respect to form and content of spoken text. Additionally, our project included a longitudinal self-assessment study with university students from Zurich (n = 18) and unemployed adults from Valencia (n = 18) in order to test the feasibility of the speech analysis method in home environments. RESULTS: The normative data showed that speaking behavior and voice sound characteristics can be quantified in a reproducible and language-independent way. The high resolution of the method was verified by a computerized assignment of speech parameter patterns to languages at a success rate of 90%, while the correct assignment to texts was 70%. In the longitudinal self-assessment study we calculated individual 'baselines' for each test person along with deviations thereof. The significance of such deviations was assessed through the normative reference data. CONCLUSIONS: Our data provided gender-, age-, and language-specific thresholds that allow one to reliably distinguish between 'natural fluctuations' and 'significant changes'. The longitudinal self-assessment study with repeated assessments at 1-day intervals over 14 days demonstrated the feasibility and efficiency of the speech analysis method in home environments, thus clearing the way to a broader range of applications in psychiatry. © 2014 S. Karger AG, Basel.
Resumo:
L’objectif principal de cette thèse est d’examiner et d’intervenir auprès des déficits de la mémoire de travail (MdeT) à l’intérieur de deux populations cliniques : la maladie d’Alzheimer (MA) et le trouble cognitif léger (TCL). La thèse se compose de trois articles empiriques. Le but de la première expérimentation était d’examiner les déficits de MdeT dans le vieillissement normal, le TCL et la MA à l’aide de deux versions de l’empan complexe : l’empan de phrases et l’empan arithmétique. De plus, l’effet de «l’oubli» (forgetting) a été mesuré en manipulant la longueur de l’intervalle de rétention. Les résultats aux tâches d’empan complexe indiquent que la MdeT est déficitaire chez les individus atteints de TCL et encore plus chez les gens ayant la MA. Les données recueillies supportent également le rôle de l’oubli à l’intérieur de la MdeT. L’augmentation de l’intervalle de rétention exacerbait le déficit dans la MA et permettait de prédire un pronostic négatif dans le TCL. L’objectif de la deuxième étude était d’examiner la faisabilité d’un programme d’entraînement cognitif à l’ordinateur pour la composante de contrôle attentionnel à l’intérieur de la MdeT. Cette étude a été réalisée auprès de personnes âgées saines et de personnes âgées avec TCL. Les données de cette expérimentation ont révélé des effets positifs de l’entraînement pour les deux groupes de personnes. Toutefois, l’absence d’un groupe contrôle a limité l’interprétation des résultats. Sur la base de ces données, la troisième expérimentation visait à implémenter une étude randomisée à double-insu avec groupe contrôle d’un entraînement du contrôle attentionnel chez des personnes TCL avec atteinte exécutive. Ce protocole impliquait un paradigme de double-tâche composé d’une tâche de détection visuelle et d’une tâche de jugement alpha-arithmétique. Alors que le groupe contrôle pratiquait simplement la double-tâche sur six périodes d’une heure chacune, le groupe expérimental recevait un entraînement de type priorité variable dans lequel les participants devaient gérer leur contrôle attentionnel en variant la proportion de ressources attentionnelles allouée à chaque tâche. Les résultats montrent un effet significatif de l’intervention sur une des deux tâches impliquées (précision à la tâche de détection visuelle) ainsi qu’une tendance au transfert à une autre tâche d’attention divisée, mais peu d’effets de généralisation à d’autres tâches d’attention. En résumé, les données originales rapportées dans la présente thèse démontrent un déficit de la MdeT dans les maladies neurodégénératives liées à l’âge, avec un gradient entre le TCL et la MA. Elles suggèrent également une préservation de la plasticité des capacités attentionnelles chez les personnes à risque de développer une démence.
Resumo:
Background: Studies evaluating acceptability of simplified follow-up after medical abortion have focused on high-resource or urban settings where telephones, road connections, and modes of transport are available and where women have formal education. Objective: To investigate women's acceptability of home-assessment of abortion and whether acceptability of medical abortion differs by in-clinic or home-assessment of abortion outcome in a low-resource setting in India. Design: Secondary outcome of a randomised, controlled, non-inferiority trial. Setting Outpatient primary health care clinics in rural and urban Rajasthan, India. Population: Women were eligible if they sought abortion with a gestation up to 9 weeks, lived within defined study area and agreed to follow-up. Women were ineligible if they had known contraindications to medical abortion, haemoglobin < 85mg/l and were below 18 years. Methods: Abortion outcome assessment through routine clinic follow-up by a doctor was compared with home-assessment using a low-sensitivity pregnancy test and a pictorial instruction sheet. A computerized random number generator generated the randomisation sequence (1: 1) in blocks of six. Research assistants randomly allocated eligible women who opted for medical abortion (mifepristone and misoprostol), using opaque sealed envelopes. Blinding during outcome assessment was not possible. Main outcome measures: Women's acceptability of home-assessment was measured as future preference of follow-up. Overall satisfaction, expectations, and comparison with previous abortion experiences were compared between study groups. Results: 731 women were randomized to the clinic follow-up group (n = 353) or home-assessment group (n = 378). 623 (85%) women were successfully followed up, of those 597 (96%) were satisfied and 592 (95%) found the abortion better or as expected, with no difference between study groups. The majority, 355 (57%) women, preferred home-assessment in the event of a future abortion. Significantly more women, 284 (82%), in the home-assessment group preferred home-assessment in the future, as compared with 188 (70%) of women in the clinic follow-up group, who preferred clinic follow-up in the future (p < 0.001). Conclusion: Home-assessment is highly acceptable among women in low-resource, and rural, settings. The choice to follow-up an early medical abortion according to women's preference should be offered to foster women's reproductive autonomy.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study is to survey radiographic measurement estimation in the assessment of dental implant length according to dentists' confidence. A 19-point questionnaire with closed-ended questions was used by two graduate students to interview 69 dentists during a dental implant meeting. Included were 12 questions related to over- and underestimation in three radiographic modalities: panoramic (P), conventional tomography (T), and computerized tomography (CT). The database was analyzed by Epi-Info 6.04 software and the values from two radiographic modalities, P and T, were compared using a chi2 test. The results showed that 38.24% of the dentists' confidence was in the overestimation of measurements in P, 30.56% in T, and 0% in CT. On the other hand, considering the underestimated measurements, the percentages were 47.06% in P, 33.33% in T, and 1.92% in CT. The frequency of under- and overestimation were statistically significant (chi2 = 6.32; P = .0425) between P and T. CT was the radiographic modality with higher measurement precision according to dentists' confidence. In conclusion, the interviewed dentists felt that CT was the best radiographic modality when considering the measurement estimation precision in preoperative dental implant assessment.
Resumo:
This study examined the relationships between gross chemical composition and ultrasonographic characteristics of the ram testes. Ten testes from sexually mature Karakul rams were scanned ex situ with an 8-MHz linear-array transducer, in a transverse and longitudinal plane. All ultrasonograms were saved as digital images and subjected to computerized analyses. Crude protein content was determined by the Kjeldahl method, moisture was determined with an oven-drying method, and fat was measured by the Soxhlet extraction of dried samples. Mean pixel values (r = -0.64, P = 0.04), pixel heterogeneity (standard deviation of pixel values; r = -0.64, P = 0.04) and maximum pixel intensity (r = -0.76, P = 0.01) were all negatively correlated with parenchymal protein content. Pixel heterogeneity correlated directly with extractable lipids (r = 0.66, P = 0.02). The quantitative correlations between echotextural and biochemical parameters found in the present experiment confirm the utility of ultrasonographic imaging combined with computer-assisted image analysis for determining changes in testicular histophysiology. © 2013 Elsevier Ltd. All rights reserved.