988 resultados para Compression Analysis
Resumo:
As an alternative fuel for compression ignition engines, plant oils are in principle renewable and carbon-neutral. However, their use raises technical, economic and environmental issues. A comprehensive and up-to-date technical review of using both edible and non-edible plant oils (either pure or as blends with fossil diesel) in CI engines, based on comparisons with standard diesel fuel, has been carried out. The properties of several plant oils, and the results of engine tests using them, are reviewed based on the literature. Findings regarding engine performance, exhaust emissions and engine durability are collated. The causes of technical problems arising from the use of various oils are discussed, as are the modifications to oil and engine employed to alleviate these problems. The review shows that a number of plant oils can be used satisfactorily in CI engines, without transesterification, by preheating the oil and/or modifying the engine parameters and the maintenance schedule. As regards life-cycle energy and greenhouse gas emission analyses, these reveal considerable advantages of raw plant oils over fossil diesel and biodiesel. Typical results show that the life-cycle output-to-input energy ratio of raw plant oil is around 6 times higher than fossil diesel. Depending on either primary energy or fossil energy requirements, the life-cycle energy ratio of raw plant oil is in the range of 2–6 times higher than corresponding biodiesel. Moreover, raw plant oil has the highest potential of reducing life-cycle GHG emissions as compared to biodiesel and fossil diesel.
Resumo:
In this paper a methodology for evaluation of information security of objects under attacks, processed by methods of compression, is represented. Two basic parameters for evaluation of information security of objects – TIME and SIZE – are chosen and the characteristics, which reflect on their evaluation, are analyzed and estimated. A co-efficient of information security of object is proposed as a mean of the coefficients of the parameter TIME and SIZE. From the simulation experiments which were carried out methods with the highest co-efficient of information security had been determined. Assessments and conclusions for future investigations are proposed.
Resumo:
A substantial amount of information on the Internet is present in the form of text. The value of this semi-structured and unstructured data has been widely acknowledged, with consequent scientific and commercial exploitation. The ever-increasing data production, however, pushes data analytic platforms to their limit. This thesis proposes techniques for more efficient textual big data analysis suitable for the Hadoop analytic platform. This research explores the direct processing of compressed textual data. The focus is on developing novel compression methods with a number of desirable properties to support text-based big data analysis in distributed environments. The novel contributions of this work include the following. Firstly, a Content-aware Partial Compression (CaPC) scheme is developed. CaPC makes a distinction between informational and functional content in which only the informational content is compressed. Thus, the compressed data is made transparent to existing software libraries which often rely on functional content to work. Secondly, a context-free bit-oriented compression scheme (Approximated Huffman Compression) based on the Huffman algorithm is developed. This uses a hybrid data structure that allows pattern searching in compressed data in linear time. Thirdly, several modern compression schemes have been extended so that the compressed data can be safely split with respect to logical data records in distributed file systems. Furthermore, an innovative two layer compression architecture is used, in which each compression layer is appropriate for the corresponding stage of data processing. Peripheral libraries are developed that seamlessly link the proposed compression schemes to existing analytic platforms and computational frameworks, and also make the use of the compressed data transparent to developers. The compression schemes have been evaluated for a number of standard MapReduce analysis tasks using a collection of real-world datasets. In comparison with existing solutions, they have shown substantial improvement in performance and significant reduction in system resource requirements.
Resumo:
International audience
Resumo:
The Subaxial Injury Classification (SLIC) system and severity score has been developed to help surgeons in the decision-making process of treatment of subaxial cervical spine injuries. A detailed description of all potential scored injures of the SLIC is lacking. We performed a systematic review in the PubMed database from 2007 to 2014 to describe the relationship between the scored injuries in the SLIC and their eventual treatment according to the system score. Patients with an SLIC of 1-3 points (conservative treatment) are neurologically intact with the spinous process, laminar or small facet fractures. Patients with compression and burst fractures who are neurologically intact are also treated nonsurgically. Patients with an SLIC of 4 points may have an incomplete spinal cord injury such as a central cord syndrome, compression injuries with incomplete neurologic deficits and burst fractures with complete neurologic deficits. SLIC of 5-10 points includes distraction and rotational injuries, traumatic disc herniation in the setting of a neurological deficit and burst fractures with an incomplete neurologic deficit. The SLIC injury severity score can help surgeons guide fracture treatment. Knowledge of the potential scored injures and their relationships with the SLIC are of paramount importance for spine surgeons who treated subaxial cervical spine injuries.
Resumo:
There are controversies about the use of local anesthetics during balloon compression for trigeminal neuralgia (TN) as a protective factor for cardiovascular events. The objective of this study was to investigate cardiovascular parameters (blood pressure and heart rate [HR]) of patients that underwent trigeminal balloon compression with local anesthetics compared to a control group (placebo). This is a randomized controlled study; 55 patients were randomized into two groups: study (deep sedation and trigeminal block with 0.8-mL lidocaine 2%) and control group (deep sedation and trigeminal injection of 0.8-mL saline). Blood pressure and HR were measured in five distinct moments: preoperative, during puncture for local anesthesia/placebo, during puncture with the catheter, during balloon compression, and final evaluation. Statistical analysis was performed with Pearson`s chi (2) and McNemar tests and the analysis of variance for repetitive measures. The means of systolic and diastolic blood pressures (SBP and DBP, respectively) were higher in the control group when compared to the study group at the evaluation during puncture with the catheter (p < 0.001) and balloon compression (p < 0.001 and p = 0.018 for DBP and SBP, respectively). There was an increase in the HR in the control group during the procedure (p = 0.017). The use of local anesthetics during the trigeminal balloon compression for TN can have a preventive role for the risk of cardiovascular events.
Resumo:
This paper presents a theoretical and experimental analysis of socket base connections of precast concrete structures with regard to the behavior of transverse walls. The experimental program included seven specimens, for which the type of interface in contact with cast-in-place concrete, the load eccentricities and the embedded lengths were all varied, A design model was proposed to calculate the reinforcements of the transverse walls. Based on the obtained results, some conclusions can be drawn: (a) The top of the transverse wall on the compression side of the smooth connections and the top of the two transverse walls of the rough connections are submitted to a bending-tension and this tension prevails on the bending; (b) The design model proposed for the calculation of the reinforcement of the transverse wall on the compression side provides the best prediction of the experimental results for all specimens when compared to the current design models; (c) For rough interfaces, the top of the transverse wall on the tension side is more requested than the top of transverse wall on the compression side; (d) The results of the proposed design model for the reinforcement of the transverse wall on the tension side of rough connections were in close agreement with the experimental results. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
The study of absorption refrigeration systems has had increasing importance in recent years due to the fact that the primary energy that is used in an absorption system can be heat available from a residual source or even a renewable one. Therefore, these systems not only use energy that would be rejected by the environment, but also they avoid the consumption of expensive fossil or electrical energies. The production cost of the mechanical work necessary to obtain a kW of refrigeration for mechanical compression cycle is normally higher than the cost for recovering the needed heat to obtain the same kW in an absorption cycle. Also, the use of these systems reduces impact on the environment by decreasing the emission of CO(2). We intend to show the performance of a hybrid absorption-ejecto compression chiller compared to conventional double- and single-effect water/lithium bromide systems, by means of an exergetic and exergoeconomic analysis of these configurations in order to calculate the exergy-based cost of a final product. The vapor compression refrigeration system is included in the results, as a comparisson to the performance of the absorption refrigeration systems analyzed.
Resumo:
The most-used refrigeration system is the vapor-compression system. In this cycle, the compressor is the most complex and expensive component, especially the reciprocating semihermetic type, which is often used in food product conservation. This component is very sensitive to variations in its operating conditions. If these conditions reach unacceptable levels, failures are practically inevitable. Therefore, maintenance actions should be taken in order to maintain good performance of such compressors and to avoid undesirable stops of the system. To achieve such a goal, one has to evaluate the reliability of the system and/or the components. In this case, reliability means the probability that some equipment cannot perform their requested functions for an established time period, under defined operating conditions. One of the tools used to improve component reliability is the failure mode and effect analysis (FMEA). This paper proposes that the methodology of FMEA be used as a tool to evaluate the main failures found in semihermetic reciprocating compressors used in refrigeration systems. Based on the results, some suggestions for maintenance are addressed.
Resumo:
In the preceding paper (Part I) force-deformation data were measured with the compression experiment in conjunction with the initial radial stretch ratio and the initial wall-thickness to cell-radius ratio for baker's yeast (Saccharomyces cerevisiae). In this paper, these data have been analysed with the mechanical model of Smith et al. (Smith, Moxham & Middelberg (1998) Chemical Engineering Science, 53, 3913-3922) with the wall constitutive behaviour defined a priori as incompressible and linear-elastic. This analysis determined the mean Young's modulus ((E) over bar), mean maximum von Mises stress-at-failure (<(sigma)over bar>(VM,f)) and mean maximum von Mises strain-at failure (<(epsilon)over bar>(VM,f)) to be (E) over bar = 150 +/- 15 MPa, <(sigma)over bar>(VM,f) = 70 +/- 4 MPa and <(epsilon)over bar>(VM,f) = 0.75 +/- 0.08, respectively. The mean Young's modulus was not dependent (P greater than or equal to 0.05) on external osmotic pressure (0-0.8 MPa) nor compression rate (1.03-7.68 mu m/s) suggesting the incompressible linear-elastic relationship is representative of the actual cell-wall constitutive behaviour. Hydraulic conductivities were also determined and were comparable to other similar cell types (0-2.5 mu m/MPa s). The hydraulic conductivity distribution was not dependent on external osmotic pressure (0-0.8 MPa) nor compression rate (1.03-7.68 mu m/s) suggesting inclusion of cell-wall permeability in the mechanical model is justified. <(epsilon)over bar>(VM,f) was independent of cell diameter and to a first-approximation unaffected (P greater than or equal to 0.01) by external osmotic pressure and compression rate, thus providing a reasonable failure criterion. This criterion states that the cell-wall material will break when the strain exceeds <(epsilon)over bar>(VM,f) = 0.75 +/- 0.08. Variability in overall cell strength during compression was shown to be primarily due to biological variability in the maximum von Mises strain-at-failure. These data represent the first estimates of cell-wall material properties for yeast and the first fundamental analysis of cell-compression data. They are essential for describing cell-disruption at the fundamental level of fluid-cell interactions in general bioprocesses. They also provide valuable new measurements for yeast-cell physiologists. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
Purpose The aim of this study was to test the correlation between Fourier-domain (FD) optical coherence tomography (OCT) macular and retinal nerve fibre layer (RNFL) thickness and visual field (VF) loss on standard automated perimetry (SAP) in chiasmal compression. Methods A total of 35 eyes with permanent temporal VF defects and 35 controls underwent SAP and FD-OCT (3D OCT-1000; Topcon Corp.) examinations. Macular thickness measurements were averaged for the central area and for each quadrant and half of that area, whereas RNFL thickness was determined for six sectors around the optic disc. VF loss was estimated in six sectors of the VF and in the central 16 test points in the VF. The correlation between VF loss and OCT measurements was tested with Spearman`s correlation coefficients and with linear regression analysis. Results Macular and RNFL thickness parameters correlated strongly with SAP VF loss. Correlations were generally stronger between VF loss and quadrantic or hemianopic macular thickness than with sectoral RNFL thickness. For the macular parameters, we observed the strongest correlation between macular thickness in the inferonasal quadrant and VF loss in the superior temporal central quadrant (rho=0.78; P<0.001) whereas for the RNFL parameters the strongest correlation was observed between the superonasal optic disc sector and the central temporal VF defect (rho=0.60; P<0.001).
Resumo:
Objectives: The purpose of this study was to measure the intraobserver and interobserver reliability of magnetic resonance detection of cervical spondylotic myelopathy with and without operational guidelines. Methods: Seven radiologists examined images from 10 patients with cord signal abnormalities and clinical signs of myelopathy. Radiologist examined films twice, with and without operational guidelines designed to define stenotic changes, while blinded to the clinical findings of the patients. Analyses included a Fleiss kappa assessment of intraobserver and interobserver reliability. Results: Results demonstrated high percentage of agreement and strong intraobserver reliability and variable Fleiss kappa, values for interobserver assessment. Operational guidelines did not improve the intraobserver or interobserver agreement. Conclusion: Although the percentage of agreement was high in some cases, the kappa agreement was low-most likely a result of the base rate problem of a kappa analysis. Sample bias toward severe degenerative changes resulted in highly prevalent selections and kappa adjusted values. Nonetheless, the results do suggest that substantial intraobserver kappa agreement and a wide range of interobserver kappa agreement exists among trained radiologists during detection of stenotic changes associated with cervical spondylotic myelopathy.
Resumo:
PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093
Resumo:
Objective. Endothelial impairment evaluation by sonographic measurement of flow-mediated dilatation (FMD) has become broadly used. However, this method has 2 main caveats: the dilatation depends on the baseline arterial diameter, and a high precision level is required. Vasodilatation leads to an amplified fall in impedance. We hypothesized that assessment of the pulsatility index change (PI-C) 1 minute after 5-minute forearm compression might evaluate that fall in impedance. The aim of this study was to compare the PI-C with FMD. Methods. Flow-mediated dilatation and the PI-C were assessed in 51 healthy women aged between 35.1 and 67.1 years. We correlated both FMD and the PI-C with age, body mass index, waist circumference, cholesterol level, high-density lipoprotein level, glucose level, systolic and diastolic blood pressure, pulse pressure, brachial artery diameter, simplified Framingham score, intima-media thickness, and carotid stiffness index. Intraclass correlation coefficients between 2 FMD and PI-C measurements were also examined. Results. Only FMD correlated with baseline brachial diameter (r=-0.53). The PI-C had a high correlation with age, body mass index, waist circumference, cholesterol level, systolic blood pressure, pulse pressure, simplified Framingham score, and intima-media thickness. The correlation between FMD and the PI-C was high (r=-0.66). The PI-C had a higher intraclass correlation coefficient (0.991) than FMD (0.836) but not brachial artery diameter (0.989). Conclusions. The PI-C had a large correlation with various markers of cardiovascular risk. Additionally, PI-C measurement does not require offline analysis, extra software, or electrocardiography We think that the PI-C could be considered a marker of endothelial function. However, more studies are required before further conclusions.
Resumo:
The objective of this study was to evaluate the bone repair along a mandibular body osteotomy after using a 2.0 miniplate system. Nine adult mongrel dogs were subjected to unilateral continuous defect through an osteotomy between the mandibular 3rd and 4th premolars. Two four-hole miniplates were placed in accordance with the Arbeitgeimeinschaft fur Osteosynthesefragen Manual. Miniplates adapted to the alveolar processes were fixed monocortically with 6.0-mm-length titanium alloy self-tapping screws, whereas miniplates placed near the mandible bases were fixed bicortically. At 2, 6 and 12 weeks, three dogs were sacrificed per period, and the osteotomy sites were removed, divided into three thirds (Tension Third, TT; Intermediary Third, IT; Compression Third, CT) and prepared for conventional and polarized light microscopy. At 6 weeks, while the CT repaired faster and showed bone union by woven bone formation, the TT and IT exhibited a ligament-like fibrous connective tissue inserted in, and connecting, newly formed woven bone overlying the parent lamellar bone edges. At 12 weeks, bone repair took place at all thirds. Histometrically, proportions of newly formed bone did not alter at TT, IT and CT, whereas significantly enhanced bone formation was observed for the 12-week group, irrespective of the third. The results demonstrated that although the method used to stabilize the mandibular osteotomy allowed bone repair to occur, differences in the dynamics of bone healing may take place along the osteotomy site, depending on the action of tension and compression forces generated by masticatory muscles.