984 resultados para Color Doppler tissue imaging
Resumo:
Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB
Resumo:
Although the diagnosis of Graves' orbitopathy is primarily made clinically based on laboratory tests indicative of thyroid dysfunction and autoimmunity, imaging studies, such as computed tomography, magnetic resonance imaging, ultrasound and color Doppler imaging, play an important role both in the diagnosis and follow-up after clinical or surgical treatment of the disease. Imaging studies can be used to evaluate morphological abnormalities of the orbital structures during the diagnostic workup when a differential diagnosis versus other orbital diseases is needed. Imaging may also be useful to distinguish the inflammatory early stage from the inactive stage of the disease. Finally, imaging studies can be of great help in identifying patients prone to develop dysthyroid optic neuropathy and therefore enabling the timely diagnosis and treatment of the condition, avoiding permanent visual loss. In this paper, we review the imaging modalities that aid in the diagnosis and management of Graves' orbitopathy, with special emphasis on the diagnosis of optic nerve dysfunction in this condition.
Resumo:
Background. Abdominal porto-systemic collaterals (APSC) on Color-Doppler ultrasound are a frequent finding in portal hypertensive cirrhotic patients. In patients with cirrhosis, an HVPG ≥ 16mmHg has been shown to be associated with increased mortality in two studies. Non-invasive indicators of HVPG ≥ 16 mmHg might define a subgroup of high-risk patients, but data on this aspect are lacking. Aims. We aimed to investigate whether HVPG predicts mortality in patients with clinically significant portal hypertension, and if APSC may predict a severe portal hypertensive state (i.e. HVPG≥16mmHg) in patients with cirrhosis and untreated portal hypertension. Methods. We analysed paired HVPG and ultrasonographic data of 86 untreated portal hypertensive cirrhotic patients. On abdominal echo-color-Doppler data on presence, type and number of APSC were prospectively collected. HVPG was measured following published guidelines. Clinical, laboratory and endoscopic data were available in all cases. First decompensation of cirrhosis and liver-disease related mortality on follow-up (mean 28±20 months) were recorded. Results. 73% of patients had compensated cirrhosis, while 27% were decompensated. All patients had an HVPG≥10 mmHg (mean 17.8±5.1 mmHg). 58% of compensated patients and 82% of decompensated patients had an HVPG over 16 mmHg. 25% had no varices, 28% had small varices, and 47% had medium/large varices. HVPG was higher in patients with esophageal varices vs. patients without varices (19.0±4.8 vs. 14.1±4.2mmHg, p<0.0001), and correlated with Child-Pugh score (R=0.494,p=0.019). 36 (42%) patients had APSC were more frequent in decompensated patients (60% vs. 35%, p=0.03) and in patients with esophageal varices (52% vs. 9%,p=0.001). HVPG was higher in patients with APSC compared with those without PSC (19.9± 4.6 vs. 16.2± 4.9mmHg, p=0.001). The prevalence of APSC was higher in patients with HVPG≥16mmHg vs. those with HVPG<16mmHg (57% vs. 13%,p<0.0001). Decompensation was significantly more frequent in patients with HVPG≥16mmHg vs. HVPG<16mmHg (35.1% vs. 11.5%, p=0.02). On multivariate analysis only HVPG and bilirubin were independent predictors of first decompensation. 10 patients died during follow-up. All had an HVPG≥16 mmHg (26% vs. 0% in patients with HVPG <16mmHg,p=0.04). On multivariate analysis only MELD score and HVPG ≥16mmHg were independent predictors of mortality. In compensated patients the detection of APSC predicted an HVPG≥16mmHg with 92% specificity, 54% sensitivity, positive and negative likelihood ratio 7.03 and 0.50, which implies that the demonstration of APSC on ultrasound increased the probability of HVPG≥16mmHg from 58% to 91%. Conclusions. HVPG maintains an independent prognostic value in the subset of patients with cirrhosis and clinically significant portal hypertension. The presence of APSC is a specific indicator of severe portal hypertension in patients with cirrhosis. Detection of APSC on ultrasound allows the non-invasive identification of a subgroup of compensated patients with bad prognosis, avoiding the invasive measurement of HVPG.
Resumo:
OBJECTIVE: The aim of this study was to evaluate soft tissue image quality of a mobile cone-beam computed tomography (CBCT) scanner with an integrated flat-panel detector. STUDY DESIGN: Eight fresh human cadavers were used in this study. For evaluation of soft tissue visualization, CBCT data sets and corresponding computed tomography (CT) and magnetic resonance imaging (MRI) data sets were acquired. Evaluation was performed with the help of 10 defined cervical anatomical structures. RESULTS: The statistical analysis of the scoring results of 3 examiners revealed the CBCT images to be of inferior quality regarding the visualization of most of the predefined structures. Visualization without a significant difference was found regarding the demarcation of the vertebral bodies and the pyramidal cartilages, the arteriosclerosis of the carotids (compared with CT), and the laryngeal skeleton (compared with MRI). Regarding arteriosclerosis of the carotids compared with MRI, CBCT proved to be superior. CONCLUSIONS: The integration of a flat-panel detector improves soft tissue visualization using a mobile CBCT scanner.
Resumo:
Background: False-negative interpretations of do-butamine stress echocardiography (DSE) may be associated with reduced wall stress. using measurements of contraction, we sought whether these segments were actually ischemic but unrecognized or showed normal contraction. Methods. We studied 48 patients (29 men; mean age 60 +/- 10 years) with normal regional function on the basis of standard qualitative interpretation of DSE. At coronary angiography within. 6 months of DSE, 32 were identified as having true-negative and 16 as having false-negative results of DSE. Three apical views were used to measure regional function with color Doppler tissue, integrated backscatter, and strain rate imaging. Cyclic variation of integrated backscatter was measured in 16 segments, and strain rate and peak systolic strain was calculated in 6 walls at rest and peak stress. Results. Segments with false-negative results of DSE were divided into 2 groups with and without low wall stress according to previously published cut-off values. Age, sex, left ventricular mass, left ventricular geometric pattern, and peak workload were not significantly different between patients with true and false-negative results of DSE. Importantly, no significant differences in cyclic variation and strain parameters at rest and peak stress were found among segments with true-and false-negative results of DSE with and without low wall stress. Stenosis severity had no influence on cyclic variation and strain parameters at peak stress. Conclusions: False-negative results of DSE reflect lack of ischemia rather than underinterpretation of regional left ventricular function. Quantitative markers are unlikely to increase the sensitivity of DSE.
Resumo:
This study aimed to evaluate the Color Doppler ultrasound as a substitute for laparoscopy for couting of corpora lutea (CL) in superovulated sheep. In conclusion, the Color Doppler ultrasonography is highly efficient to estimate the number of CLs in superovulated ewes. This represents an important advance because it replaces invasive laparoscopic procedure, avoids fasting, drugs use and unnecessary handling in animals that did not respond to the treatment. Therefore, the Color Doppler ultrasound can replace the laparoscopy for the assessment of superovulated sheep.
Resumo:
AIM To determine the relation between the extent and distribution of left ventricular hypertrophy and the degree of disturbance of regional relaxation and global left ventricular filling. METHODS Regional wall thickness (rWT) was measured in eight myocardial regions in 17 patients with hypertrophic cardiomyopathy, 12 patients with hypertensive heart disease, and 10 age matched normal subjects, and an asymmetry index calculated. Regional relaxation was assessed in these eight regions using regional isovolumetric relaxation time (rIVRT) and early to late peak filling velocity ratio (rE/A) derived from Doppler tissue imaging. Asynchrony of rIVRT was calculated. Doppler left ventricular filling indices were assessed using the isovolumetric relaxation time, the deceleration time of early diastolic filling (E-DT), and the E/A ratio. RESULTS There was a correlation between rWT and both rIVRT and rE/A in the two types of heart disease (hypertrophic cardiomyopathy: r = 0.47, p < 0.0001 for rIVRT; r = -0.20, p < 0.05 for rE/A; hypertensive heart disease: r = 0.21, p < 0.05 for rIVRT; r = -0.30, p = 0.003 for rE/A). The degree of left ventricular asymmetry was related to prolonged E-DT (r = 0. 50, p = 0.001) and increased asynchrony (r = 0.42, p = 0.002) in all patients combined, but not within individual groups. Asynchrony itself was associated with decreased E/A (r = -0.39, p = 0.01) and protracted E-DT (r = 0.69, p < 0.0001) and isovolumetric relaxation time (r = 0.51, p = 0.001) in all patients. These correlations were still significant for E-DT in hypertrophic cardiomyopathy (r = 0.56, p = 0.02) and hypertensive heart disease (r = 0.59, p < 0.05) and for isovolumetric relaxation time in non-obstructive hypertrophic cardiomyopathy (n = 8, r = 0.87, p = 0.005). CONCLUSIONS Non-invasive ultrasonographic examination of the left ventricle shows that in both hypertrophic cardiomyopathy and hypertensive heart disease, the local extent of left ventricular hypertrophy is associated with regional left ventricular relaxation abnormalities. Asymmetrical distribution of left ventricular hypertrophy is indirectly related to global left ventricular early filling abnormalities through regional asynchrony of left ventricular relaxation.
Resumo:
Background: Doppler ultrasonography is a non-invasive real time pulse-wave technique recently used for the transrectal study of the reproductive system hemodynamics in large animals. This technic is based in the Doppler Effect Principle that proposes the change in frequency of a wave for an observer (red blood cells) moving relative to the source of the respective wave (ultrasonic transducer). This method had showed to be effective and useful for the evaluation of the in vivo equine reproductive tract increasing the diagnostic, monitoring, and predictive capabilities of theriogenology in mares. However, an accurate and truthful ultrasonic exam requires the previous knowledge of the Doppler ultrasonography principles. Review: In recent years, the capabilities of ultrasound flow imaging have increased enormously. The current Doppler ultrasound machines offer three methods of evaluation that may be used simultaneously (triplex mode). In B-mode ultrasound, a linear array of transducers simultaneously scans a plane through the tissue that can be viewed as a two-dimensional gray-scale image on screen. This mode is primarily used to identify anatomically a structure for its posterior evaluation using colored ultrasound modes (Color or Spectral modes). Colored ultrasound images of flow, whether Color or Spectral modes, are essentially obtained from measurements of moving red cells. In Color mode, velocity information is presented as a color coded overlay on top of a B-mode image, while Pulsed Wave Doppler provides a measure of the changing velocity throughout the cardiac cycle and the distribution of velocities in the sample volume represented by a spectral graphic. Color images conception varies according to the Doppler Frequency that is the difference between the frequency of received echoes by moving blood red cells and wave frequency transmitted by the transducer. To produce an adequate spectral graphic it is important determine the position and size of the simple gate. Furthermore, blood flow velocity measurement is influence by the intersection angle between ultrasonic pulses and the direction of moving blood-red cells (Doppler angle). Objectively colored ultrasound exam may be done on large arteries of the reproductive tract, as uterine and ovary arteries, or directly on the target tissue (follicle, for example). Mesovarium and mesometrium attachment arteries also can be used for spectral evaluation of the equine reproductive system. Subjectively analysis of the ovarian and uterine vascular perfusion must be done directly on the corpus luteum, follicular wall and uterus (endometrium and myometrium associated), respectively. Power-flow imaging has greater sensitivity to weak blood flow and independent of the Doppler angle, improving the evaluation of vessels with small diameters and slow blood flow. Conclusion: Doppler ultrasonography principles, methods of evaluation and reproductive system anatomy have been described. This knowledge is essential for the competent equipment acquisition and precise collection and analysis of colored ultrasound images. Otherwise, the reporting of inconsistent and not reproducible findings may result in the discredit of Doppler technology ahead of the scientific veterinary community.
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Background Accurate diagnosis of portal vein (PV) stenosis by real-time and color Doppler US (CD-US) after segmental liver transplantation in children can decrease morbidity by avoiding unnecessary biopsy, PV hypertension, thrombosis and loss of the graft. Objective To evaluate CD-US parameters for the prediction of PV stenosis after segmental liver transplantation in children. Materials and methods We retrospectively reviewed 61 CD-US examinations measuring the diameter at the PV anastomosis, velocities at the anastomosis (PV1) and in the segment proximal to the anastomosis (PV2), and the PV1/PV2 velocity ratio. The study group comprised patients with stenosis confirmed by angiography and the control group comprised patients with a good clinical outcome. Results PV stenosis was seen in 12 CD-US examinations. The mean PV diameter was smaller in the study group (2.6 mm versus 5.7 mm) and a PV diameter of < 3.5 mm was highly predictive of stenosis (sensitivity 100%, specificity 91.8%). Conclusion A PV diameter of < 3.5 mm is a highly predictive CD-US parameter for the detection of hemodynamically significant stenosis on angiography.
Resumo:
A prospective clinical study was carried out to evaluate the influence of posture on perineal ultrasound imaging parameters. One hundred and thirty-two consecutive women presenting with symptoms of lower urinary tract dysfunction were examined by multichannel videourodynamics and perineal ultrasound, both supine and standing. Ultrasound included color Doppler imaging when available, i.e. in a subgroup of 99 patients. The position of the bladder neck at rest was higher in the supine position (P
Resumo:
Background Systolic myocardial Doppler velocity accurately identifies coronary artery disease. However, these velocities may be affected by age, hemodynamic responses to stress, and left ventricular cavity size. We sought to examine the influences of these variables on myocardial velocity during dobutamine stress in patients with normal wall motion. Methods One hundred seventy-nine consecutive patients with normal dobutamine echocardiograms were studied. Color myocardial tissue Doppler data were obtained at rest and peak stress, and peak systolic myocardial velocity (PSV) was measured in all basal and midventricular segments. Velocities at rest and peak stress were compared with left ventricular diastolic and systolic volumes, blood pressure, heart rate, and age by Pearson correlation and interdecile analysis by use of analysis of variance. Results The only clinical variable correlating with velocity was age; PSV showed only mild correlation with age at rest (r(2) = 0.01, P = .001) and peak stress (r(2) = 0.02, P = .001), but the normal peak velocity was significantly different between the extremes of age (<44 years and >74 years). There was very weak correlation of PSV with systolic and diastolic blood pressure (r(2) < 0.01), heart rate (r(2) < 0.01), systemic vascular resistance (r(2) = 0.08), and left ventricular volumes (r(2) < 0.01). Conclusions Peak systolic velocity during dobutamine stress is relatively independent of hemodynamic factors and left ventricular cavity size. The extremes of age may influence peak systolic Doppler velocities. These results suggest that peak systolic velocity may be a robust quantitative measure during dobutamine echocardiography across most patient subgroups.