514 resultados para Coliformes Termotolerantes


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Avaliaram-se a compostabilidade de diversos resíduos adequadamente misturados e a eficiência de diferentes processos (leiras estáticas aeradas e composteira) na eliminação de microrganismos e tempo de compostagem. Tratamentos: composteira: palha de café, cama de frango e carcaça de frango, LEA 01: bagaço de cana-de-açúcar, cama de frango e carcaça de frango inteira, LEA 02: bagaço de cana-de-açúcar, cama de frango e carcaça de frango triturada, LEA 03: palha de café, cama de frango e carcaça de frango triturada. Variáveis monitoradas: temperatura, relação C/N, sólidos voláteis (SV), pH e umidade, além de avaliar a eliminação de Salmonella e a redução de coliformes termotolerantes. Os resultados obtidos para redução de SV foram 20,87% (composteira), 25,31%; (LEA 01), 28,86% (LEA 02) e 54,48% (LEA 03).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A utilização de equipamentos alternativos de comprovada eficiência pode colaborar na viabilização do uso da pasteurização lenta por pequenos produtores, melhorando a rentabilidade da atividade e diminuindo o comércio de leite informal. O presente trabalho teve por objetivo avaliar a eficiência de equipamento alternativo para pasteurização lenta de leite previamente envasado. Quatorze partidas de 30 L de leite foram processadas e analisadas. As provas realizadas foram contagens de mesófilos aeróbicos, coliformes totais e coliformes termotolerantes, cálculo da redução de mesófilos aeróbicos e pesquisa da atividade das enzimas fosfatase e peroxidase. A eficiência do processo de pasteurização em reduzir o número de mesófilos aeróbicos do leite variou de 99,97 a 99,99%. Todas as amostras de leite pasteurizado apresentaram contagens de coliformes totais e termotolerantes <0,3 NMP/mL e resultados negativos e positivos para fosfatase e peroxidase, respectivamente. O equipamento testado foi eficiente na pasteurização lenta do leite previamente envasado, pois, em todas as partidas analisadas, foi obtido leite pasteurizado dentro dos padrões estabelecidos pela legislação brasileira para os parâmetros estudados.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Foram analisadas 98 amostras de polpas de frutas congeladas de 8 sabores diferentes, comercializadas em uma feira livre da cidade de Palmas-TO. Foram determinados o pH das polpas, Número Mais Provável de coliformes totais e termotolerantes (NMP.g-1) e Unidades Formadoras de Colônia de bolores e leveduras (UFC.g-1). O pH médio das polpas variou entre 2,5 e 4,8. Apenas 5 amostras (4,3%) apresentaram resultados positivos para coliformes totais e duas confirmaram a presença de coliformes termotolerantes e E. coli, com valores entre 0,3 e 0,9 NMP.g-1. Noventa por cento das amostras apresentaram contaminação por bolores e leveduras, sendo que as contagens variaram de < 10 até 6,2 x 10(4) UFC.g-1. Dentre as amostras que apresentaram bolores e leveduras, 29,6 % não se enquadraram nos padrões estabelecidos pela legislação em vigor.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Textile production has been considered as an activity of high environmental impact due to the generation of large volumes of waste water with high load of organic compounds and strongly colored effluents, toxic and difficult biodegradability. This thesis deals with obtaining porous alumina ceramic membranes for filtration of textile effluent in the removal of contaminants, mainly color and turbidity. Two types of alumina with different particle sizes as a basis for the preparation of formulation for mass production of ceramic samples and membranes. The technological properties of the samples were evaluated after using sintering conditions: 1,350ºC-2H, 1,450ºC-30M, 1,450ºC-2H, 1,475ºC-30M and 1,475ºC-2H. The sintered samples were characterized by XRD, XRF, AG, TG, DSC, DL, AA, MEA, RL, MRF-3P, SEM and Intrusion Porosimetry by Mercury. After the characterization, a standard membrane was selected with their respective sintering condition for the filterability tests. The effluent was provided by a local Textile Industry and characterized at the entry and exit of the treatment plant. A statistical analysis was used to study the effluent using the following parameters: pH, temperature, EC, SS, SD, oil and grease, turbidity, COD, DO, total phosphorus, chlorides, phenols, metals and fecal coliform. The filtered effluent was evaluated by using the same parameters. These results demonstrate that the feasibility of the use of porous alumina ceramic membranes for removing contaminants from textile effluent with improved average pore size of 0.4 micrometre (distribution range varying from 0,025 to 2.0 micrometre), with total porosity of 29.66%, and average percentages of color removal efficiency of 89.02%, 92.49% of SS, turbidity of 94.55%, metals 2.70% (manganese) to 71.52% (iron) according to each metal and COD removal of 72.80%

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The National School Nutrition Program is the oldest program in the country directed at food and nutrition safety. Its aims are to offer nutritional food as a supplement to students of public and philanthropic schools. Studying school nutrition transcends the investigation as a purely social program, given that it reaches the fields of public health, nutrition and food, using a wide variety of approaches. Thus, it is characterized by a multidisciplinary study, where the disciplines work side by side in distinct aspects of a single problem. Aim: This study aims to assess hygiene practices during the preparation of meat-based meals in public schools in the city of Natal, Brazil. Methods: A list was applied at 27 schools to identify the procedures of good food preparation practices. In addition, cooking and meal distribution temperature were measured and a microbiological analysis of the final preparation and of the water used in preparing it was performed. For microbiological analyses of the food, we analyzed coliforms at 45°C, coliforms at 35°C and Enterococcus, and for the water, we analyzed thermotolerant coliforms and total coliforms, using the methods recommended by APHA, 1995. Results: Most of the schools did not meet the required standards in all the variables related to good food preparation practices, except for the time spent preparing the meat, in which 89% were within the norm. Cooking temperature of the meals was within the standard; however, the temperature at distribution and the time spent dispensing the meals were inadequate. Of the 27 schools, 22 (81.5%) showed the presence of coliforms at 35° C in at least one meal sample and 18 (66.7%) had values above the recommended limit for coliforms at 45°C. The presence of E. coli was identified in 6.1% of the samples analyzed. The presence of Enterococcus was not found at any of the schools. With respect to the water, the North district of the city was the only one that did not meet the standards for the two indicators evaluated. The contamination found was not associated with the hygiene or food storage problems observed. Conclusions: The results show that the hygiene-sanitary conditions of meat-based public school meals were unsatisfactory, demonstrating the need for improvements in the production process to preserve the health of the student population. Multidisciplinarity: Researchers from the areas of food microbiology, nutrition, public health and statistics took part in this study, a decisive factor for characterizing the research as multidisciplinary

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The great diversity of the textile industries activities causes the formation of wastewaters with high complex characteristics during the productive process, according to the industrial process used. The principal aim of the present work is the characterization of the wastewater from the textile industry that process the indigo, located in the Industrial District of Natal-RN, to know the contaminante load of each stage of the process and the framing of the wastewater with the standards of act of receiving of the System of Treatment of Wastewater of the Industrial District of Natal-RN SITEL-DIN, operated for the Company of Waters and Sewers of the RN CAERN. It was analyzed the following properties and pollutants agents: temperature; pH; alcalinity; color; COD (Chemical Oxygen Demand); total and suspended solids; heavy metals, thermotolerants coliformes, turbidity, dissolved oxygen and electrical conductivity. As conclusion it is distinguished that the wastewater did not get resulted satisfactory, according to comparisons with other sources, in only three parameters: turbidity, dissolved oxygen and electrical conductivity, however none of these parameters is criteria of acts of receiving of the SITEL-DIN,therefore the wastewater if finds inside of normality. After the analysis of the obtained results it was verified that SITEL-DIN is indispensable for completing the wastewater treatment

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In Natal still dominates the use of individual disposal systems for domestic sewage, once only 29% of the city has a sewarage system. Wastes that are accumulated in these individual treatment systems should be exhausted periodically, service provided by collector entrepreneurs. Some of these companies causing major damage to the environment. In Natal, only two companies have their own septage (RESTI) treatment system, which were designed with parameters from domestic sewage generating strain and inefficient systems. Therefore, the characterization becomes essential as a source of parameters for their design. Thus, this work presents the physical-chemical and microbiological characterization of waste pumped from individual sewage treatment systems. Samples collections were made weekly from 5 different trucks at the reception point on the treatment plant on the point of the preliminary treatment. From each truck it was taken 5 samples during the discharge in order to make a composite sample. Afterwards, samples were carried out to laboratory and analyses for determination of temperature, pH, conductivity, BOD, COD, nitrogen (ammonia e organic), alkalinity, oils, phosphorus, solids, faecal coliforms and helminth egg. The results were treated as a single database, and ranked according to its generating source (multi and single house, lodging, health, services and / or food), area of origin (metropolitan, south and north) and type of system (cesspits, septic tank and / or sink). Through these data it was possible to verify that the type of system adopted by most in Natal and the metropolitan region is cesspit, besides to confirm the difference between the septage of areas with a population have different social and economical characteristics. It was found that the septage have higher concentrations than domestic sewage, except for thermotolerant coliforms that showed concentrations of 1,38E+07. Among the parameters studied, is the median values identified for COD (3,549 mg / L), BOD (973mg / L) and total solids (3.557mg / L). The volatile fraction constitutes about 70% of the total solids of the septage. For helminths has been a median of 7 eggs/L. In general, the characteristics of the waste followed the variability found in the literature reviewed for all variables, showing high amplitudes

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Pirangi beach is located in the eastern coastline of Rio Grande do Norte state, in the municipality of Parnamirim and Nísia Floresta. In it flow into Pirangi Watershed (PW), whose water receives large amounts of pollutants, mainly domestic and industrial sewage from districts where pass the rivers that consist it, compromising, thus, the bathing water quality of the Pirangi beach. Bearing in mind the importance of water sanitary quality to ensure an environment that no present risk to the bathers s health, this work had as main objective to assess the influence of the PW s waters in the bathing water quality of the Pirangi beaches. To that end, were made collections of water in the beaches and in the rivers with the intention of quantify the fecal contamination indicators thermotolerant coliforms and enterococci, to then classify the conditions of bathing water quality according with the CONAMA Resolution number 274 of 2000. For the purposes greater knowledge about the health conditions of the Beaches Pirangi and about the influence the PW s waters exert on it, was done parallely to the study of the water quality, an investigation of the sand sanitary quality. Furthermore, it was made an evaluation of the PW s Water Quality through Water Quality Index (WQI). Starting from the results obtained in the research present was possible to verify, among other aspects, that the entry of the PW s waters in the Pirangi beaches exerts direct influence in the bathing water quality of the same ones, being the North Pirangi beach (point tracking PA-02) the most influenced. There was noticed also a significant reduction in the conditions of bathing water quality of the beaches in the rainy season. However, the precariousness do sewerage system of the Natal metropolitan region and the absence of a right system of treatment an final disposal of domestic sewage and industrial are the main factors responsi le for deterioration of the PW s Water Quality, and as a consequence, compromising the bathing water quality of the Pirangi beaches

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.