990 resultados para Cochlea - blood supply


Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Elevated blood pressure (BP) is frequent in patients with acute ischemic stroke. Pathophysiological data support its usefulness to maintain adequate perfusion of the ischemic penumba. This review article aims to summarize the available evidence from clinical studies that examined the prognostic role of BP during the acute phase of ischemic stroke and intervention studies that assessed the efficacy of active BP alteration. RECENT FINDINGS: We found 34 observational studies (33,470 patients), with results being inconsistent among the studies; most studies reported a negative association between increased levels of BP and clinical outcome, whereas a few studies showed clinical improvement with higher BP levels, clinical deterioration with decreased BP, or no association at all. Similarly, the conclusions drawn by the 18 intervention studies included in this review (1637 patients) were also heterogeneous. Very recent clinical data suggest a possible beneficial effect of early treatment with some antihypertensives on late clinical outcome. SUMMARY: Observational and interventional studies of management of acute poststroke hypertension yield conflicting results. We discuss different explanations that may account for this and discuss the current guidelines and pathophysiological considerations for the management of acute poststroke hypertension.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Euglycemic hyperinsulinemia stimulates both sympathetic nerve activity and blood flow to skeletal muscle, but the mechanism is unknown. Possible mechanisms that may stimulate muscle blood flow include neural, humoral, or metabolic effects of insulin. To determine whether such insulin-induced vasodilation is modulated by stimulation of adrenergic or cholinergic mechanisms, we obtained, in eight healthy lean subjects, plethysmographic measurements of calf blood flow during 3 h of hyperinsulinemic (1 mU.kg-1.min-1) euglycemic clamp performed alone or during concomitant beta-adrenergic (propranolol infusion), cholinergic (atropine infusion), or alpha-adrenergic (prazosin administration) blockade. Euglycemic hyperinsulinemia alone increased calf blood flow by 38 +/- 10% (means +/- SE) and decreased vascular resistance by 27 +/- 4% (P < 0.01). The principal new observation is that these insulin-induced vasodilatory responses were not attenuated by concomitant propranolol or atropine infusion, nor were they potentiated by prazosin administration. In conclusion, these findings provide evidence that during euglycemic hyperinsulinemia in lean healthy humans stimulation of muscle blood flow is not mediated primarily by beta-adrenergic or cholinergic mechanisms. Furthermore, alpha-adrenergic mechanisms do not markedly limit insulin-induced stimulation of muscle blood flow.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Among numerous magnetic resonance imaging (MRI) techniques, perfusion MRI provides insight into the passage of blood through the brain's vascular network non-invasively. Studying disease models and transgenic mice would intrinsically help understanding the underlying brain functions, cerebrovascular disease and brain disorders. This study evaluates the feasibility of performing continuous arterial spin labeling (CASL) on all cranial arteries for mapping murine cerebral blood flow at 9.4 T. We showed that with an active-detuned two-coil system, a labeling efficiency of 0.82 ± 0.03 was achieved with minimal magnetization transfer residuals in brain. The resulting cerebral blood flow of healthy mouse was 99 ± 26 mL/100g/min, in excellent agreement with other techniques. In conclusion, high magnetic fields deliver high sensitivity and allowing not only CASL but also other MR techniques, i.e. (1)H MRS and diffusion MRI etc, in studying murine brains.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: Continuous positive airway pressure (CPAP) is the gold standard treatment for obstructive sleep apnea. However, the physiologic impact of CPAP on cerebral blood flow (CBF) is not well established. Ultrasound can be used to estimate CBF, but there is no widespread accepted protocol. We studied the physiologic influence of CPAP on CBF using a method integrating arterial diameter and flow velocity (FV) measurements obtained for each vessel supplying blood to the brain. METHODS: FV and lumen diameter of the left and right internal carotid, vertebral, and middle cerebral arteries were measured using duplex Doppler ultrasound with and without CPAP at 15 cm H(2)O, applied in a random order. Transcutaneous carbon dioxide (PtcCO(2)), heart rate (HR), blood pressure (BP), and oxygen saturation were monitored. Results were compared with a theoretical prediction of CBF change based on the effect of partial pressure of carbon dioxide on CBF. RESULTS: Data were obtained from 23 healthy volunteers (mean ± SD; 12 male, age 25.1 ± 2.6 years, body mass index 21.8 ± 2.0 kg/m(2)). The mean experimental and theoretical CBF decrease under CPAP was 12.5 % (p < 0.001) and 11.9 % (p < 0.001), respectively. The difference between experimental and theoretical CBF reduction was not statistically significant (3.84 ± 79 ml/min, p = 0.40). There was a significant reduction in PtcCO(2) with CPAP (p = <0.001) and a significant increase in mean BP (p = 0.0017). No significant change was observed in SaO(2) (p = 0.21) and HR (p = 0.62). CONCLUSION: Duplex Doppler ultrasound measurements of arterial diameter and FV allow for a noninvasive bedside estimation of CBF. CPAP at 15 cm H(2)O significantly decreased CBF in healthy awake volunteers. This effect appeared to be mediated predominately through the hypocapnic vasoconstriction coinciding with PCO(2) level reduction. The results suggest that CPAP should be used cautiously in patients with unstable cerebral hemodynamics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. PARTICIPANTS AND METHODS: The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. RESULTS: In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. CONCLUSIONS: The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: This study evaluated demographic profiles and prevalence of serologic markers among donors who used confidential unit exclusion (CUE) to assess the effectiveness of CUE and guide public policies regarding the use of CUE for enhancing safety versus jeopardizing the blood supply by dropping CUE. STUDY DESIGN AND METHODS: We conducted a cross-sectional analysis of whole blood donations at a large public blood center in Sao Paulo from July 2007 through June 2009, compared demographic data, and confirmed serologic results among donors who used and who have never used CUE (CUE never). RESULTS: There were 265,550 whole blood units collected from 181,418 donors from July 2007 through June 2009. A total of 9658 (3.6%) units were discarded, 2973 (1.1%) because CUE was used at the current donation (CUE now) and 6685 (2.5%) because CUE was used in the past (CUE past). The CUE rate was highest among donors with less than 8 years of education (odds ratio [OR], 2.78; 95% confidence interval [CI], 2.51-3.08). CUE now donations were associated with higher positive infectious disease marker rates than CUE never donations (OR, 1.41; CI, 1.13-1.77), whereas CUE past donations were not (OR, 1.04; CI, 0.75-1.45). CONCLUSION: The CUE process results in a high rate of unit discard. CUE use on an individual donation appears predictive of a high-risk marker-positive donation and, thus, appears to contribute modestly to blood safety. The policy of discarding units from donors who have previously CUE-positive donations does not improve safety and should be discontinued.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The acetabular labrum plays an important role in hip joint stability and protection of the articular cartilage of the hip. Despite this, few investigators have evaluated its microscopic vasculature and, to our knowledge, none has assessed its macroscopic blood supply. The purposes of this study were to identify the origin and course of the vascular supply to the acetabular labrum to determine if this blood supply is affected by a labral tear.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

High resolution, vascular magnetic resonance imaging of the spine region in small animals poses several challenges. The small anatomical features, extravascular diffusion, and the low signal-to-noise ratio limit the use of conventional contrast agents. We hypothesize that a long circulating, intravascular liposomal-encapsulated MR contrast agent (liposomal-Gd) would facilitate visualization of small anatomical features of the perispinal vasculature not visible with conventional contrast agent (Gd-DTPA).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Accurate screening for anemia at Red Cross blood donor clinics is essential to maintain a safe national blood supply. Despite the importance of identifying anemia correctly by measurement of hemoglobin or hematocrit (hemoglobin/hematocrit) there is no consensus regarding the efficacy of the current two stage screening method which uses the Readacrit$\sp{\rm tm}$ microhematocrit in conjunction with copper sulfate.^ A cross-sectional study was implemented in which hemoglobin/hematocrit was measured, with the present method and four new devices, on 504 prospective blood donors at a Canadian Red Cross permanent blood donor clinic in London, Canada. Concurrently gathered, venous and capillary blood samples were tested by each device and compared to Coulter S IV$\sp{\rm tm}$ determined venous standard readings. Instrument hemoglobin/hematocrit means were statistically calibrated to the standard ones in order to appraise systematic deviations from the standard. Classification analysis was employed to assess concordance between each instrument and the standard when classifying prospective donors as anemic or non-anemic. This was done both when each instrument was used alone (single stage) and when copper sulfate was used as a preliminary screen (two stage) and simulated over a range of anemia prevalences. The Hemoximeter$\sp{\rm tm}$ and Compur M1000$\sp{\rm tm}$ devices had the highest correlations of hemoglobin measurements with the standard ones for both capillary (n.s.) and venous blood (p $<$.05). Analysis of variance (anova) also showed them to be the most accurate (p $<$.05), as did both single and two stage classification analysis, therefore, they are both recommended. There was a smaller difference between instruments for two stage than for single stage screening; therefore instrument choice is less crucial for the former. The present method was adequate for two stage screening as tested but simulations showed that it would discriminate poorly in populations with a higher prevalence of anemia. The Stat-crit and Readacrit, which measure hematocrit, became less accurate at crucial low hematocrit levels. In light of this finding and the introduction of new, effective and easy to use hemoglobin measuring instruments, the continued use of hematocrit as a surrogate for hemoglobin, is not recommended. ^

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It is generally accepted that the cartilaginous frame of the reptilian cochlea has only a passive supportive function. In this study, a ribbon of contractile tissue was revealed within the cartilaginous frame of the cochlea of the gecko Teratoscincus scincus. It consisted of tightly packed cells and received an extensive blood supply. The cytoplasm of the cells was filled with cytoskeletal filaments 5-7 nm thick as revealed by electron microscopy. Isolated tissue permeabilized with Triton X-100 or glycerol reversibly contracted in the presence of ATP. Noradrenaline caused slow relaxation of the freshly isolated tissue placed in artificial perilymph. We suggest that slow motility of the contractile tissue may adjust passive cochlear mechanics to sounds of high intensities. J. Comp. Neurol. 461:539-547, 2003. © 2003 Wiley-Liss, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To investigate whether regional long-term changes in peripapillary retinal flow, measured by scanning laser Doppler flowmetry (SLDF), occur in patients with primary open angle glaucoma (POAG). Methods: 31 healthy volunteers (mean age: 65 8.3 years) and 33 POAG patients (mean age: 71.2 7.6 years) were followed up every 4 months for 16 months. Using SLDF, three images of the superior and inferior optic nerve head were obtained for each subject. A 1010-pixel frame was used to measure blood flow, volume and velocity in the four quadrants of the peripapillary retina. Central 24-2 visual field testing was carried out at each visit. Repeated measures analysis of covariance was used to assess change over time between the normal and POAG groups for the SLDF parameters. Univariate linear regression analysis for mean deviation and glaucoma change probability (GCP) analysis were used to identify visual field progression. Results: Blood volume, flow and velocity measured in the inferior nasal quadrant of the peripapillary retina decreased significantly over time for the POAG group compared to the normal group (p=0.0073, 0.0097, 0.0095 respectively). Overall, 2 glaucoma patients showed a significantly deteriorating MD slope, while 7 patients showed visual field progression with GPA. All of the patients progressing with GPA, showed change in the superior hemifield and, of those, 14% showed change in the inferior hemifield. Conclusion: Glaucoma patients showed a decrease in blood flow, volume and velocity in the inferior nasal peripapillary retina. A regional variation in microvascular retinal capillary blood flow may provide insight into the pathogenesis of glaucomatous optic neuropathy. Keywords: 331 blood supply • 554 retina • 624 visual fields

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Chronic telogen effluvium (CTE), a poorly understood condition, can be confused with or may be a prodrome to female pattern hair loss (FPHL). The pathogenesis of both is related to follicle cycle shortening and possibly to blood supply changes. To analyze a number of histomorphometric and immunohistochemical findings through vascular endothelial growth factor (VEGF), Ki-67, and CD31 immunostaining in scalp biopsies of 20 patients with CTE, 17 patients with mild FPHL and 9 controls. Ki-67 index and VEGF optical density were analyzed at the follicular outer sheath using ImageJ software. CD31 microvessel density was assessed by a Chalkley grid. Significant follicle miniaturization and higher density of nonanagen follicles were found in FPHL, compared with patients with CTE and controls. Ki-67+ index correlated positively with FPHL histological features. The FPHL group showed the highest VEGF optical density, followed by the CTE and control groups. No differences were found in CD31 microvessel density between the three groups. Histomorphometric results establish CTE as a distinct disorder, separate from FPHL from its outset. Its pathogenic mechanisms are also distinct. These findings support the proposed mechanism of 'immediate telogen release' for CTE, leading to cycle synchronization. For FPHL, accelerated anagen follicular mitotic rates and, thus, higher Ki-67 and VEGF values, would leave less time for differentiation, resulting in hair miniaturization.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Corpus luteum is a temporary endocrine gland that regulates either the estrous cycle and pregnancy. It presents extreme dependency on the adequate blood supply. This work aims to evaluate goat corpus luteum (CL) vascular density (VD) over the estrous cycle. For that purpose, 20 females were submitted to estrus synchronization/ovulation treatment using a medroxyprogesterone intra-vaginal sponge as well as intramuscular (IM) application of cloprostenol and equine chorionic gonadotrophine (eCG). After sponge removal, estrus was identified at about 72hs. Once treatment was over, female goats were then subdivided into 4 groups (n=5 each) and slaughtered on days 2, 12, 16 and 22 after ovulation (p.o). Ovaries were collected, withdrawn and weighted. CL and ovaries had size and area recorded. Blood samples were collected and the plasma progesterone (P4) was measured through RIA commercial kits. The VD was 24.42±6.66, 36.26±5.61, 8.59±2.2 and 3.97±1.12 vessels/mm² for days 2, 12, 16 and 22 p.o, respectively. Progesterone plasma concentrations were 0.49±0.08, 2.63±0.66, 0.61±0.14 and 0.22±0.04ng/ml for days 2, 12, 16 e 22 p.o, respectively. Studied parameters were affected by the estrous cycle phase. Values greater than 12 p.o were observed. In the present work we observed that ovulation occurred predominantly in the right ovary (70% of the animals), which in turn presented bigger measures than the contra lateral one. There is a meaningful relationship between the weight and size of the ovary and these of CL (r=0.87, r=0.70, respectively, p<0.05). It is possible to conclude that morphology of goat's ovaries and plasma progesterone concentration changed according to estrous cycle stages. We propose these parameters can be used as indicators of CL functional activity.